Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur J Neurol ; 27(10): 1988-1995, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32431009

RESUMO

BACKGROUND AND PURPOSE: Malignant middle cerebral artery infarction (MMI) is a severe complication of acute ischaemic stroke (AIS). The aim of our study was to assess whether successful reperfusion after endovascular therapy (EVT) in AIS with clinical and imaging predictors of MMI decreased its occurrence. METHODS: Data were collected between January 2014 and July 2018 in a monocentric prospective AIS registry of patients treated with EVT. Patients selected were <65 years old with severe anterior circulation AIS with a National Institutes of Health Stroke Scale score >15, baseline Diffusion-Weighted Imaging-Alberta Stroke Program Early Computed Tomography Score ≤ 6 and baseline diffusion-weighted imaging lesion volume >82 mL within 6 h of symptom onset. Successful reperfusion was defined as a Thrombolysis in Cerebral Ischemia score ≥ 2b. Occurrence of MMI was the primary endpoint. RESULTS: A total of 66 EVT-treated patients were included in our study. MMI occurred in 27 patients (41%). In unadjusted analysis, successful reperfusion was associated with fewer MMIs (31.8% vs. 65.0%; P = 0.015) and with more favorable outcome at 3 months (50% vs. 20%; P = 0.023). In multivariate analysis, successful reperfusion was associated with an adjusted odds ratio (95% confidence intervals) of 0.35 (0.10-1.12) for MMI and 2.77 (0.84-10.43) for 3-month favorable outcome occurrence. CONCLUSIONS: Early successful reperfusion performed in patients with AIS with clinical and imaging predictors of MMI was associated with decreased MMI occurrence. Reperfusion status might be considered in evaluating the need for craniectomy in patients with early predictors of MMI.


Assuntos
Isquemia Encefálica , Procedimentos Endovasculares , Acidente Vascular Cerebral , Idoso , Isquemia Encefálica/complicações , Isquemia Encefálica/diagnóstico por imagem , Humanos , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Estudos Prospectivos , Reperfusão , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Trombectomia , Resultado do Tratamento
2.
Eur J Neurol ; 27(2): 384-391, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31532865

RESUMO

BACKGROUND AND PURPOSE: There are few clinico-radiological data on optic neuritis (ON) with myelin oligodendrocyte glycoprotein antibody (MOG-IgG). The objective was to characterize the clinico-radiological phenotype and outcome of patients with MOG-IgG-related ON. METHODS: The records of all adult patients admitted in three medical centres with MOG-IgG-associated ON who underwent orbital and brain magnetic resonance imaging (MRI) at the acute phase were reviewed. Spinal cord MRI within 1 month from the ON and all of the follow-up MRI were reviewed. RESULTS: Of 62 patients, 41.9% had bilateral ON and 66.2% optic disc swelling. On initial MRI, lesions were anterior (92%), extensive (63%) and associated with optic perineuritis (46.6%). Silent brain lesions were found in 51.8% of patients but were mainly non-specific (81%). Of 39 individuals with spinal MRI at onset, nine had abnormal findings (four were asymptomatic). Two symptomatic patients had longitudinally extensive myelitis with concurrent H-sign. At last follow-up, 5% of patients had visual acuity ≤0.1. Brain MRI remained unchanged in 41 patients (87%). CONCLUSIONS: Our study supports a mostly benign ophthalmological course of MOG-IgG-associated ON, despite initially longitudinally extensive lesions and development of optic nerve atrophy on orbital MRI. Spinal MRI could be of interest in detecting silent suggestive lesions.


Assuntos
Mielite , Neurite Óptica , Adulto , Autoanticorpos , Seguimentos , Humanos , Glicoproteína Mielina-Oligodendrócito , Neurite Óptica/diagnóstico por imagem
3.
Eur J Neurol ; 27(8): 1561-1569, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32301260

RESUMO

BACKGROUND AND PURPOSE: Multinodular and vacuolating neuronal tumor (MVNT) of the cerebrum is a rare brain lesion with suggestive imaging features. The aim of our study was to report the largest series of MVNTs so far and to evaluate the utility of advanced multiparametric magnetic resonance (MR) techniques. METHODS: This multicenter retrospective study was approved by our institutional research ethics board. From July 2014 to May 2019, two radiologists read in consensus the MR examinations of patients presenting with a lesion suggestive of an MVNT. They analyzed the lesions' MR characteristics on structural images and advanced multiparametric MR imaging. RESULTS: A total of 64 patients (29 women and 35 men, mean age 44.2 ± 15.1 years) from 25 centers were included. Lesions were all hyperintense on fluid-attenuated inversion recovery and T2-weighted imaging without post-contrast enhancement. The median relative apparent diffusion coefficient on diffusion-weighted imaging was 1.13 [interquartile range (IQR), 0.2]. Perfusion-weighted imaging showed no increase in perfusion, with a relative cerebral blood volume of 1.02 (IQR, 0.05) and a relative cerebral blood flow of 1.01 (IQR, 0.08). MR spectroscopy showed no abnormal peaks. Median follow-up was 2 (IQR, 1.2) years, without any changes in size. CONCLUSIONS: A comprehensive characterization protocol including advanced multiparametric magnetic resonance imaging sequences showed no imaging patterns suggestive of malignancy in MVNTs. It might be useful to better characterize MVNTs.


Assuntos
Neoplasias Encefálicas , Imageamento por Ressonância Magnética Multiparamétrica , Adulto , Neoplasias Encefálicas/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
4.
Metab Brain Dis ; 33(1): 353-355, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29090380

RESUMO

The radiological spectrum of neuromyelitis optica has become broader since the detection of aquaporin4 antibodies. We report a case of neuromyelitis optica patient with pseudotumoral encephalic lesion. A 66 year-old woman presented with sudden left lateral homonymous hemianopsia. A brain MRI showed an isolated and extensive right temporo-parieto-occipital lesion, involving periventricular white matter and the corpus callosum, with strong enhancement on post-gadolinium T1 weighted images, highly suggestive of lymphoma. Spinal cord MRI and body CT scan were unremarkable. Lumbar puncture showed pleocytosis, raised total protein level without abnormal cells or oligoclonal bands. A brain biopsy demonstrated non-specific demyelination. Serum aquaporin4 antibodies were positive, which was consistent with the diagnosis of neuromyelitis optica. Cases of central nervous system aquaporin4 autoimmunity presenting with an isolated brain lesion without optic neuritis or myelitis are extremely rare: this is the second case so far and the first one with advanced magnetic resonance characterization. Pseudotumoral encephalic lesions should include a large differential diagnosis, and testing aquaporin4 antibodies must be considered in order to avoid brain biopsy.


Assuntos
Aquaporina 4/metabolismo , Autoimunidade/imunologia , Encéfalo/patologia , Neuromielite Óptica/imunologia , Idoso , Aquaporina 4/imunologia , Corpo Caloso/imunologia , Corpo Caloso/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Neuromielite Óptica/diagnóstico , Neuromielite Óptica/patologia , Medula Espinal/imunologia , Medula Espinal/patologia
5.
Eur Radiol ; 27(4): 1335-1343, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27436015

RESUMO

OBJECTIVES: To measure the frequency of infraorbital nerve enlargement (IONE) on magnetic resonance imaging (MRI) in European patients suffering from an IgG4-related ophthalmic disease (IgG4-ROD) as compared to patients suffering from non-IgG4-related ophthalmic disease (non-IgG4-ROD). METHODS: From January 2006 through April 2015, 132 patients were admitted for non-lymphoma, non-thyroid-related orbital inflammation. Thirty-eight had both pre-therapeutic orbital MRI and histopathological IgG4 immunostaining. Fifteen patients were classified as cases of IgG4-ROD and 23 patients as cases of non-IgG4-ROD. Two readers performed blinded analyses of MRI images. The main criterion was the presence of an IONE, defined as the infraorbital nerve diameter being greater than the optic nerve diameter in the coronal section. RESULTS: IONE was present in 53% (8/15) of IgG4-ROD cases whereas it was never present (0/23) in cases of non-IgG4-ROD (P < 0.0001). IONE was only present in cases where, on MRI, the inflammation of the inferior quadrant was present and in direct contact with the ION canal. CONCLUSIONS: In European patients suffering from orbital inflammation, the presence of IONE on an MRI is a specific sign of IgG4-ROD. Recognition of this pattern may facilitate the accurate diagnosis for clinicians and allow for the adequate management and appropriate care of their patients. KEY POINTS: • IONE on an MRI is a specific sign of IgG4-ROD. • IONE recognition allows for a quicker diagnosis and appropriate management. • IONE appears when inflammation is in direct contact with the ION canal.


Assuntos
Imunoglobulina G/sangue , Imageamento por Ressonância Magnética/métodos , Nervo Óptico/patologia , Doenças Orbitárias/diagnóstico por imagem , Paraproteinemias/diagnóstico por imagem , Europa (Continente) , Feminino , Humanos , Hipertrofia , Masculino , Pessoa de Meia-Idade , Nervo Óptico/diagnóstico por imagem , Doenças Orbitárias/sangue , Doenças Orbitárias/patologia , Paraproteinemias/sangue , Paraproteinemias/patologia , Estudos Retrospectivos
8.
Rev Neurol (Paris) ; 168(1): 53-6, 2012 Jan.
Artigo em Francês | MEDLINE | ID: mdl-21683970

RESUMO

Floating carotid thrombi are a rare cause of stroke mostly associated with atheromatous plaques, cardiogenic emboli, arterial dissections and systemic diseases related to coagulopathic states or iron deficiency anaemia. We report the cases of two patients with stroke and carotid megabulb or suspended bulb associated with floating thrombus. These findings are rarely described probably related to a form of arterial dysplasia and seem to be responsible of local haemodynamic modifications.


Assuntos
Trombose das Artérias Carótidas/patologia , Acidente Vascular Cerebral/patologia , Trombose/patologia , Adulto , Anticoagulantes/uso terapêutico , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/patologia , Trombose das Artérias Carótidas/diagnóstico por imagem , Angiografia Cerebral , Circulação Cerebrovascular/fisiologia , Feminino , Heparina/uso terapêutico , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Parestesia/etiologia , Acidente Vascular Cerebral/diagnóstico por imagem , Trombose/diagnóstico por imagem , Trombose/etiologia , Tomografia Computadorizada por Raios X , Ultrassonografia Doppler
10.
Cancer Radiother ; 26(5): 736-741, 2022 Sep.
Artigo em Francês | MEDLINE | ID: mdl-35249816

RESUMO

Hypofractionated stereotactic radiotherapy and stereotactic radiosurgery are major therapeutic weapons in the brain, whether for tumor, vascular or functional treatments. They tend increasingly to democratize and to become standard treatments. However, human brain anatomy is very complex and not limited to the currently described organs at risk. Diffusion tensor imaging (DTI) tractography is a simple tool that enables to identify reproducibly big white matter fiber tracts. Not only does tractography allow a redefinition of organs at risk in the brain, but it would also allow the identification of new targets, such as the ventral intermediate nucleus (Vim) within the thalamus for treatment of movement disorders. We present here a review of the role of tractography and the anatomy, function and currently described dose-effect relationships of white matter fiber tracts with a major functional impact: the pyramidal tract for motor ability, the optic radiation for vision and the arcuate fasciculus for language.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Substância Branca , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/radioterapia , Imagem de Tensor de Difusão/métodos , Humanos , Radiocirurgia/métodos , Substância Branca/diagnóstico por imagem , Substância Branca/patologia
11.
Rev Laryngol Otol Rhinol (Bord) ; 131(4-5): 281-4, 2010.
Artigo em Francês | MEDLINE | ID: mdl-21866740

RESUMO

Arachnoid granulations play a role in CSF drainage. They are primarily located adjacent to cerebral venous sinuses. They may arise on a bony surface causing progressive bony erosion. We report two cases of arachnoid granulations eroding the posterior wall of the temporal bone. The aim of this paper was to illustrate the clinical presentation, and the imaging findings of arachnoid granulation of the posterior wall of the temporal bone. They remain asymptomatic in most cases, but they might cause a communication between the subarachnoid space and mastoid air cells, increasing the risk of bacterial meningitis, subdural empyema, and other intracranial infections. Differential diagnoses are also described, including endolymphatic sac tumours.


Assuntos
Aracnoide-Máter/anormalidades , Osso Temporal/patologia , Aracnoide-Máter/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade
12.
J Neurol ; 267(2): 406-414, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31655891

RESUMO

BACKGROUND: Spinal imaging in multiple sclerosis remains challenging because of its small size and numerous artifacts. OBJECTIVE: To compare 3D Phase-Sensitive Inversion Recovery (PSIR) to a conventional dataset of 3D Short Tau Inversion Recovery (STIR) and T2-weighted imaging at 3 Tesla to detect multiple sclerosis spinal cord lesions. METHODS: This prospective single-center study was approved by a national research ethics board and included 54 patients (median age 44) enrolled from December 2016 to August 2018. Two neuroradiologists individually analyzed the two datasets separately and in random order. Discrepancies were resolved by consensus with a third neuroradiologist. The primary judgment criterion was the number of spinal cord lesions. Secondary judgment criteria included location of the lesions, reader-reported confidence and conspicuity assessed with the lesion-to-cord contrast ratio (LCCR). RESULTS: 3D PSIR detected significantly more lesions than the conventional dataset (371 versus 173, respectively, p < 0.05). Seven patients had no detected lesion with the conventional dataset, whereas 3D PSIR detected at least one lesion. LCCR mean reader-reported confidence (p < 0.001) and inter-observer agreement were higher using 3D PSIR. CONCLUSIONS: 3D PSIR significantly improved overall spinal cord lesion detection in MS patients, with higher reader-reported confidence, higher lesion contrast, and higher inter-reader agreement.


Assuntos
Esclerose Múltipla/diagnóstico por imagem , Neuroimagem/métodos , Doenças da Medula Espinal/diagnóstico por imagem , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/patologia , Estudos Prospectivos , Doenças da Medula Espinal/patologia
13.
AJNR Am J Neuroradiol ; 41(9): 1663-1669, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32819903

RESUMO

BACKGROUND AND PURPOSE: Endovascular navigation through tortuous vessels can be complex. Tools that can optimise this access phase need to be developed. Our aim was to evaluate the feasibility of supra-aortic vessel catheterization guidance by means of live fluoroscopy fusion with MR angiography or CT angiography. MATERIALS AND METHODS: Twenty-five patients underwent preinterventional diagnostic MRA, and 8 patients underwent CTA. Fusion guidance was evaluated in 35 sessions of catheterization, targeting a total of 151 supra-aortic vessels. The time for MRA/CTA segmentation and fluoroscopy with MRA/CTA coregistration was recorded. The feasibility of fusion guidance was evaluated by recording the catheterizations executed by interventional neuroradiologists according to a standard technique under fluoroscopy and conventional road-mapping independent of the fusion guidance. Precision of the fusion roadmap was evaluated by measuring (on a semiquantitative 3-point scale) the maximum offset between the position of the guidewires/catheters and the vasculature on the virtual CTA/MRA images. The targeted vessels were divided in 2 groups according to their position from the level of the aortic arch. RESULTS: The average time needed for segmentation and image coregistration was 7 ± 2 minutes. The MRA/CTA virtual roadmap overlaid on live fluoroscopy was considered accurate in 84.8% (128/151) of the assessed landmarks, with a higher accuracy for the group of vessels closer to the aortic arch (92.4%; OR, 4.88; 95% CI, 1.83-11.66; P = .003). CONCLUSIONS: Fluoroscopy with MRA/CTA fusion guidance for supra-aortic vessel interventions is feasible. Further improvements of the technique to increase accuracy at the cervical level and further studies are needed for assessing the procedural time savings and decreasing the x-ray radiation exposure.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Procedimentos Endovasculares/métodos , Angiografia por Ressonância Magnética/métodos , Radiografia Intervencionista/métodos , Cirurgia Assistida por Computador/métodos , Aorta/cirurgia , Cateterismo , Estudos de Viabilidade , Feminino , Fluoroscopia/métodos , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade
14.
AJNR Am J Neuroradiol ; 40(7): 1170-1176, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31248862

RESUMO

BACKGROUND AND PURPOSE: There is no consensus regarding the best MR imaging sequence for detecting MS lesions. The aim of our study was to assess the diagnostic value of optimized 3D-FLAIR in the detection of infratentorial MS lesions compared with an axial T2-weighted imaging, a 3D-FLAIR with factory settings, and a 3D double inversion recovery sequence. MATERIALS AND METHODS: In this prospective study, 27 patients with confirmed MS were included. Two radiologists blinded to clinical data independently read the following sequences: axial T2WI, 3D double inversion recovery, standard 3D-FLAIR with factory settings, and optimized 3D-FLAIR. The main judgment criterion was the overall number of high-signal-intensity lesions in the posterior fossa; secondary objectives were the assessment of the reading confidence and the measurement of the contrast. A nonparametric Wilcoxon test was used to compare the MR images. RESULTS: Twenty-two patients had at least 1 lesion in the posterior fossa. The optimized FLAIR sequence detected significantly more posterior fossa lesions than any other sequence: 7.5 versus 5.8, 4.8, and 4.1 (P values of .04, .03, and .03) with the T2WI, the double inversion recovery, and the standard FLAIR, respectively. The reading confidence index was significantly higher with the optimized FLAIR, and the contrast was significantly higher with the optimized FLAIR than with the standard FLAIR and the double inversion recovery. CONCLUSIONS: An optimized 3D-FLAIR sequence improved posterior fossa lesion detection in patients with MS.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico por imagem , Neuroimagem/métodos , Adulto , Encéfalo/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/patologia , Estudos Prospectivos
15.
J Neurol ; 266(11): 2786-2795, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31372735

RESUMO

BACKGROUND: To assess the diagnostic value of three 3D FLAIR sequences with differing repetition-times (TR) at 3-Tesla when detecting multiple sclerosis (MS) lesions. METHODS: In this prospective study, approved by the institutional review board, 27 patients with confirmed MS were prospectively included. One radiologist performed manual segmentations of all high-signal intensity lesions using three 3D FLAIR data sets with different TR of 4800 ms ("FLAIR4800"), 8000 ms ("FLAIR8000") and 10,000 ms ("FLAIR10,000") and two radiologists double-checked it. The main judgment criterion was the overall number of lesions; secondary objectives were the assessment of lesion location, as well as measuring contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). A non-parametric Wilcoxon's test was used to compare the differing FLAIR. RESULTS: The FLAIR8000 and FLAIR10,000 detected significantly more overall lesions per patient as compared with the FLAIR4800 [116.1 (± 61.7) (p = 0.02) and 115.8 (± 56.3) (p = 0.03) versus 99.2 (± 66.9), respectively]. The FLAIR8000 and FLAIR10,000 detected four and eight times more cortical or juxta-cortical lesions per patient as compared with FLAIR4800 [1.6 (± 2.2) (p = 0.001) and 4.1 (± 5.9) (p = 6 × 10-5) versus 0.4 (± 1.1), respectively]. CNR was significantly correlated to the TR value. It was significantly higher with FLAIR10,000 than it was with FLAIR8000 and FLAIR4800 [16.3 (± 3.5) versus 15 (± 2.4) (p = 0.01) and 12 (± 2.2) (p = 2 × 10-6), respectively] CONCLUSION: An optimized 3D FLAIR with a long TR significantly improved both overall lesion detection and CNR in MS patients as compared to a 3D FLAIR with factory settings.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico por imagem , Neuroimagem/métodos , Adulto , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
16.
AJNR Am J Neuroradiol ; 40(2): 370-375, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30679225

RESUMO

BACKGROUND AND PURPOSE: Magnetic Resonance Imaging is the modality of choice to detect spinal cord lesions in patients with Multiple Sclerosis (MS). However, this imaging is challenging. New sequences such as phase-sensitive inversion recovery have been developed to improve detection. Our aim was to compare a 3D phase-sensitive inversion recovery and a conventional imaging dataset including postcontrast T2WI and T1WI to detect MS spinal cord lesions. MATERIALS AND METHODS: This retrospective single-center study included 100 consecutive patients with MS (mean age, 41 years) from January 2015 to June 2016. One senior neuroradiologist and 1 junior radiologist blinded to clinical data checked for new spinal cord lesions, individually analyzing conventional and 3D phase-sensitive inversion recovery datasets separately, placing a 3-week delay between the 2 readings. A consensus reading was done with a third senior neuroradiologist. A Wilcoxon test was used to compare the 2 imaging datasets. Intra- and interobserver agreement was assessed by the κ coefficient. RESULTS: 3D phase-sensitive inversion recovery detected significantly more lesions than conventional imaging (480 versus 168, P < .001). Eleven patients had no detected lesions on T2WI, whereas 3D phase-sensitive inversion recovery detected at least 1 lesion. All postcontrast T1WI enhancing lesions were also visible on 3D phase-sensitive inversion recovery. The signal-to-noise ratio was significantly higher using 3D phase-sensitive inversion recovery (0.63 versus 0.46, P = .03). Mean reading confidence was significantly higher using 3D phase-sensitive inversion recovery. Inter- and intraobserver agreement was good for both datasets. CONCLUSIONS: Our study showed that 3D phase-sensitive inversion recovery significantly improved detection of cervical spinal cord lesions, including both enhancing and nonenhancing lesions in patients with MS.


Assuntos
Medula Cervical/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico por imagem , Neuroimagem/métodos , Adulto , Medula Cervical/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/patologia , Estudos Retrospectivos
17.
Sci Rep ; 9(1): 2068, 2019 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-30765732

RESUMO

To evaluate the relative contribution of different Magnetic Resonance Imaging (MRI) sequences for the extraction of radiomics features in a cohort of patients with lacrimal gland tumors. This prospective study was approved by the Institutional Review Board and signed informed consent was obtained from all participants. From December 2015 to April 2017, 37 patients with lacrimal gland lesions underwent MRI before surgery, including axial T1-WI, axial Diffusion-WI, coronal DIXON-T2-WI and coronal post-contrast DIXON-T1-WI. Two readers manually delineated both lacrimal glands to assess inter-observer reproducibility, and one reader performed two successive delineations to assess intra-observer reproducibility. Radiomics features were extracted using an in-house software to calculate 85 features per region-of-interest (510 features/patient). Reproducible features were defined as features presenting both an intra-class correlation coefficient ≥0.8 and a concordance correlation coefficient ≥0.9 across combinations of the three delineations. Among these features, the ones yielding redundant information were identified as clusters using hierarchical clustering based on the Spearman correlation coefficient. All the MR sequences provided reproducible radiomics features (range 14(16%)-37(44%)) and non-redundant clusters (range 5-14). The highest numbers of features and clusters were provided by the water and in-phase DIXON T2-WI and water and in-phase post-contrast DIXON T1-WI (37, 26, 26 and 26 features and 14,12, 9 and 11 clusters, respectively). A total of 145 reproducible features grouped into 51 independent clusters was provided by pooling all the MR sequences. All MRI sequences provided reproducible radiomics features yielding independent information which could potentially serve as biomarkers.


Assuntos
Neoplasias Oculares/patologia , Adulto , Análise por Conglomerados , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Aparelho Lacrimal/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Software
18.
AJNR Am J Neuroradiol ; 40(7): 1184-1190, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31248864

RESUMO

BACKGROUND AND PURPOSE: Leptomeningeal enhancement can be found in a variety of neurologic diseases such as Susac Syndrome. Our aim was to assess its prevalence and significance of leptomeningeal enhancement in Susac syndrome using 3T postcontrast fluid-attenuated inversion recovery MR imaging. MATERIALS AND METHODS: From January 2011 to December 2017, nine consecutive patients with Susac syndrome and a control group of 73 patients with multiple sclerosis or clinically isolated syndrome were included. Two neuroradiologists blinded to the clinical and ophthalmologic data independently reviewed MRIs and assessed leptomeningeal enhancement and parenchymal abnormalities. Follow-up MRIs (5.9 MRIs is the mean number per patient over a median period of 46 months) of patients with Susac syndrome were reviewed and compared with clinical and retinal fluorescein angiographic data evaluated by an independent ophthalmologist. Fisher tests were used to compare the 2 groups, and mixed-effects logistic models were used for analysis of clinical and imaging follow-up of patients with Susac syndrome. RESULTS: Patients with Susac syndrome were significantly more likely to present with leptomeningeal enhancement: 5/9 (56%) versus 6/73 (8%) in the control group (P = .002). They had a significantly higher leptomeningeal enhancement burden with ≥3 lesions in 5/9 patients versus 0/73 (P < .001). Regions of leptomeningeal enhancement were significantly more likely to be located in the posterior fossa: 5/9 versus 0/73 (P < .001). Interobserver agreement for leptomeningeal enhancement was good (κ = 0.79). There was a significant association between clinical relapses and increase of both leptomeningeal enhancement and parenchymal lesion load: OR = 6.15 (P = .01) and OR = 5 (P = .02), respectively. CONCLUSIONS: Leptomeningeal enhancement occurs frequently in Susac syndrome and could be helpful for diagnosis and in predicting clinical relapse.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Síndrome de Susac/diagnóstico por imagem , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Meninges/diagnóstico por imagem , Meninges/patologia , Recidiva , Estudos Retrospectivos , Síndrome de Susac/patologia , Adulto Jovem
19.
AJNR Am J Neuroradiol ; 40(10): 1689-1694, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31558497

RESUMO

Multinodular and vacuolating neuronal tumor of the cerebrum is a rare supratentorial brain tumor described for the first time in 2013. Here, we report 11 cases of infratentorial lesions showing similar striking imaging features consisting of a cluster of low T1-weighted imaging and high T2-FLAIR signal intensity nodules, which we referred to as multinodular and vacuolating posterior fossa lesions of unknown significance. No relationship was found between the location of the lesion and clinical symptoms. A T2-FLAIR hypointense central dot sign was present in images of 9/11 (82%) patients. Cortical involvement was present in 2/11 (18%) of patients. Only 1 nodule of 1 multinodular and vacuolating posterior fossa lesion of unknown significance showed enhancement on postcontrast T1WI. DWI, SWI, MRS, and PWI showed no malignant pattern. Lesions did not change in size or signal during a median follow-up of 3 years, suggesting that multinodular and vacuolating posterior fossa lesions of unknown significance are benign malformative lesions that do not require surgical intervention or removal.


Assuntos
Neoplasias Infratentoriais/diagnóstico por imagem , Neoplasias Infratentoriais/patologia , Adulto , Idoso , Encéfalo/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
20.
AJNR Am J Neuroradiol ; 39(7): 1226-1232, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29880479

RESUMO

BACKGROUND AND PURPOSE: MR imaging is the key examination in the follow-up of patients with MS, by identification of new high-signal T2 brain lesions. However, identifying new lesions when scrolling through 2 follow-up MR images can be difficult and time-consuming. Our aim was to compare an automated coregistration-fusion reading approach with the standard approach by identifying new high-signal T2 brain lesions in patients with multiple sclerosis during follow-up MR imaging. MATERIALS AND METHODS: This prospective monocenter study included 94 patients (mean age, 38.9 years) treated for MS with dimethyl fumarate from January 2014 to August 2016. One senior neuroradiologist and 1 junior radiologist checked for new high-signal T2 brain lesions, independently analyzing blinded image datasets with automated coregistration-fusion or the standard scroll-through approach with a 3-week delay between the 2 readings. A consensus reading with a second senior neuroradiologist served as a criterion standard for analyses. A Poisson regression and logistic and γ regressions were used to compare the 2 methods. Intra- and interobserver agreement was assessed by the κ coefficient. RESULTS: There were significantly more new high-signal T2 lesions per patient detected with the coregistration-fusion method (7 versus 4, P < .001). The coregistration-fusion method detected significantly more patients with at least 1 new high-signal T2 lesion (59% versus 46%, P = .02) and was associated with significantly faster overall reading time (86 seconds faster, P < .001) and higher reader confidence (91% versus 40%, P < 1 × 10-4). Inter- and intraobserver agreement was excellent for counting new high-signal T2 lesions. CONCLUSIONS: Our study showed that an automated coregistration-fusion method was more sensitive for detecting new high-signal T2 lesions in patients with MS and reducing reading time. This method could help to improve follow-up care.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico por imagem , Neuroimagem/métodos , Adulto , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/patologia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA