Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 49(1): 234-245, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33978829

RESUMO

PURPOSE: Calcineurin inhibitors (CNI) can cause long-term impairment of brain function. Possible pathomechanisms include alterations of the cerebral immune system. This study used positron emission tomography (PET) imaging with the translocator protein (TSPO) ligand 18F-GE-180 to evaluate microglial activation in liver-transplanted patients under different regimens of immunosuppression. METHODS: PET was performed in 22 liver-transplanted patients (3 CNI free, 9 with low-dose CNI, 10 with standard-dose CNI immunosuppression) and 9 healthy controls. The total distribution volume (VT) estimated in 12 volumes-of-interest was analyzed regarding TSPO genotype, CNI therapy, and cognitive performance. RESULTS: In controls, VT was about 80% higher in high affinity binders (n = 5) compared to mixed affinity binders (n = 3). Mean VT corrected for TSPO genotype was significantly lower in patients compared to controls, especially in patients in whom CNI dose had been reduced because of nephrotoxic side effect. CONCLUSION: Our results provide evidence of chronic suppression of microglial activity in liver-transplanted patients under CNI therapy especially in patients with high sensitivity to CNI toxicity.


Assuntos
Transplante de Fígado , Microglia , Encéfalo/metabolismo , Humanos , Terapia de Imunossupressão/efeitos adversos , Microglia/metabolismo , Tomografia por Emissão de Pósitrons , Receptores de GABA/metabolismo
2.
Eur J Nucl Med Mol Imaging ; 47(12): 2887-2900, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32322915

RESUMO

PURPOSE: Tracer kinetic modeling of tissue time activity curves and the individual input function based on arterial blood sampling and metabolite correction is the gold standard for quantitative characterization of microglia activation by PET with the translocator protein (TSPO) ligand 18F-GE-180. This study tested simplified methods for quantification of 18F-GE-180 PET. METHODS: Dynamic 18F-GE-180 PET with arterial blood sampling and metabolite correction was performed in five healthy volunteers and 20 liver-transplanted patients. Population-based input function templates were generated by averaging individual input functions normalized to the total area under the input function using a leave-one-out approach. Individual population-based input functions were obtained by scaling the input function template with the individual parent activity concentration of 18F-GE-180 in arterial plasma in a blood sample drawn at 27.5 min or by the individual administered tracer activity, respectively. The total 18F-GE-180 distribution volume (VT) was estimated in 12 regions-of-interest (ROIs) by the invasive Logan plot using the measured or the population-based input functions. Late ROI-to-whole-blood and ROI-to-cerebellum ratio were also computed. RESULTS: Correlation with the reference VT (with individually measured input function) was very high for VT with the population-based input function scaled with the blood sample and for the ROI-to-whole-blood ratio (Pearson correlation coefficient = 0.989 ± 0.006 and 0.970 ± 0.005). The correlation was only moderate for VT with the population-based input function scaled with tracer activity dose and for the ROI-to-cerebellum ratio (0.653 ± 0.074 and 0.384 ± 0.177). Reference VT, population-based VT with scaling by the blood sample, and ROI-to-whole-blood ratio were sensitive to the TSPO gene polymorphism. Population-based VT with scaling to the administered tracer activity and the ROI-to-cerebellum ratio failed to detect a polymorphism effect. CONCLUSION: These results support the use of a population-based input function scaled with a single blood sample or the ROI-to-whole-blood ratio at a late time point for simplified quantitative analysis of 18F-GE-180 PET.


Assuntos
Encéfalo , Tomografia por Emissão de Pósitrons , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Carbazóis , Humanos , Receptores de GABA/metabolismo , Reprodutibilidade dos Testes
3.
Eur J Nucl Med Mol Imaging ; 45(11): 1934-1944, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29967943

RESUMO

PURPOSE: The chemokine receptor CXCR4 is a promising target for molecular imaging of CXCR4+ cell types, e.g. inflammatory cells, in cardiovascular diseases. We speculated that a specific CXCR4 ligand, [68Ga]pentixafor, along with novel techniques for motion correction, would facilitate the in vivo characterization of CXCR4 expression in small culprit and nonculprit coronary atherosclerotic lesions after acute myocardial infarction by motion-corrected targeted PET/CT. METHODS: CXCR4 expression was analysed ex vivo in separately obtained arterial wall specimens. [68Ga]Pentixafor PET/CT was performed in 37 patients after stent-based reperfusion for a first acute ST-segment elevation myocardial infarction. List-mode PET data were reconstructed to five different datasets using cardiac and/or respiratory gating. Guided by CT for localization, the PET signals of culprit and various groups of nonculprit coronary lesions were analysed and compared. RESULTS: Ex vivo, CXCR4 was upregulated in atherosclerotic lesions, and mainly colocalized with CD68+ inflammatory cells. In vivo, elevated CXCR4 expression was detected in culprit and nonculprit lesions, and the strongest CXCR4 PET signal (median SUVmax 1.96; interquartile range, IQR, 1.55-2.31) was observed in culprit coronary artery lesions. Stented nonculprit lesions (median SUVmax 1.45, IQR 1.23-1.88; P = 0.048) and hot spots in naive remote coronary segments (median SUVmax 1.34, IQR 1.23-1.74; P = 0.0005) showed significantly lower levels of CXCR4 expression. Dual cardiac/respiratory gating provided the strongest CXCR4 PET signal and the highest lesion detectability. CONCLUSION: We demonstrated the basic feasibility of motion-corrected targeted PET/CT imaging of CXCR4 expression in coronary artery lesions, which was triggered by vessel wall inflammation but also by stent-induced injury. This novel methodology may serve as a platform for future diagnostic and therapeutic clinical studies targeting the biology of coronary atherosclerotic plaque.


Assuntos
Complexos de Coordenação , Regulação Neoplásica da Expressão Gênica , Movimento , Peptídeos Cíclicos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/metabolismo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Receptores CXCR4/metabolismo , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Placa Aterosclerótica/complicações , Placa Aterosclerótica/fisiopatologia , Respiração , Estudos Retrospectivos
4.
Eur Heart J ; 38(6): 436-443, 2017 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-27469371

RESUMO

Aims: High-energy resolution and sensitivity of novel cadmium-zinc-telluride (CZT) detector equipped SPECT systems facilitate simultaneous imaging of multiple isotopes and may enhance the detection of molecular/cellular signals. This may refine the detection of endocarditis. This study was designed to determine the feasibility and diagnostic accuracy of simultaneous imaging of inflammation with 111In-labeled white blood cells (WBCs) and myocardial perfusion with 99mTc-sestamibi, for localization of WBCs relative to the valve plane in suspected endocarditis. Methods and results: A dedicated cardiac CZT camera (Discovery 530c, GE Healthcare) was employed. Anthropomorphic thorax phantom studies were followed by clinical studies in 34 patients with suspected infection of native valves (n = 12) or implants (n = 22). Simultaneous 111In-WBC/99mTc perfusion imaging was performed, and compared with standard 111In-WBC planar scintigraphy and SPECT-CT. Phantom studies ruled out significant radioisotope crosstalk. Downscatter on 99mTc images was not observed for 111In activity as high as 2.5*99mTc activity. In patients, image quality was superior for CZT imaging vs. conventional SPECT-CT and planar scintigraphy (P < 0.01). Cadmium-zinc-telluride dual isotope imaging improved reader confidence for detection of inflammatory foci. Diagnostic accuracy based on surgery or Duke Criteria during follow-up was highest for CZT imaging (P < 0.001). Conclusion: Novel CZT SPECT technology improves the accuracy of molecular/cellular cardiac imaging. Simultaneous multi-isotope imaging with 111In and 99mTc is feasible and aids in the workup of suspected endocarditis.


Assuntos
Endocardite/diagnóstico por imagem , Radioisótopos de Índio , Leucócitos , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Imagens de Fantasmas , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada de Emissão de Fóton Único/normas
5.
Front Robot AI ; 10: 1245501, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38130401

RESUMO

In this article, we present RISE-a Robotics Integration and Scenario-Management Extensible-Architecture-for designing human-robot dialogs and conducting Human-Robot Interaction (HRI) studies. In current HRI research, interdisciplinarity in the creation and implementation of interaction studies is becoming increasingly important. In addition, there is a lack of reproducibility of the research results. With the presented open-source architecture, we aim to address these two topics. Therefore, we discuss the advantages and disadvantages of various existing tools from different sub-fields within robotics. Requirements for an architecture can be derived from this overview of the literature, which 1) supports interdisciplinary research, 2) allows reproducibility of the research, and 3) is accessible to other researchers in the field of HRI. With our architecture, we tackle these requirements by providing a Graphical User Interface which explains the robot behavior and allows introspection into the current state of the dialog. Additionally, it offers controlling possibilities to easily conduct Wizard of Oz studies. To achieve transparency, the dialog is modeled explicitly, and the robot behavior can be configured. Furthermore, the modular architecture offers an interface for external features and sensors and is expandable to new robots and modalities.

6.
Front Psychol ; 13: 857234, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35865690

RESUMO

Introduction: In spring 2020, the first nationwide lockdown in response to the spreading COVID-19 pandemic came into effect in Germany. From March to May, gambling venues, casinos, and betting offices were forced to close. This study explores how land-based gamblers respond to short-term closures of higher-risk forms of gambling. Which gamblers are particularly susceptible to switching to online gambling? Which are more likely to use the lockdown as an opportunity to quit or pause gambling? Potential parameters for these switching or cessation processes are identified using multivariate multinomial logistic regression analysis. Methods: The research questions are analyzed on the basis of quantitative data. For this purpose, a survey was conducted among members of a comparatively large German online access panel ("PAYBACK panel"). The sample of analysis consisted of 612 gamblers who had participated in at least one higher-risk form of gambling and had done so exclusively offline before the first lockdown (January and February 2020). Results: A total of 37.1% of sports bettors ceased participation in higher-risk forms of gambling, compared to 64.1% of casino gamblers. Switching to online gambling, on the other hand, was a rather rare event, regardless of the form of gambling: the proportions differ between 7.7% (slot machines) and 10.9% (sports betting). In the multivariate model female gender, younger age, and a lower frequency of gambling before the first lockdown were found to be significant factors for quitting (instead of continuing) higher-risk offline gambling forms. Secondly, the analysis revealed that individuals with more pronounced cognitive distortions had an increased risk of switching to online gambling rather than staying offline. Discussion: A key finding of this study is that the temporary closure of offline venues does not result in a significant shift towards the online market. Instead, the results of this study show that these short, temporary closures of gambling venues were an appropriate opportunity to give individual groups of gamblers the opportunity to reflect, reduce or quit gambling. It is worth considering implementing such temporary closures as a preventive measure in the future - this should be investigated in advance in further evaluation studies.

7.
J Clin Med ; 10(17)2021 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-34501284

RESUMO

(1) Background: To comparatively analyze the uptake of hepatocellular carcinoma (HCC) on pre-therapeutic imaging modalities, the arterial phase multi-detector computed tomography (MDCT), the parenchymal phase C-arm computed tomography (CACT), the Technetium99m-macroaggregates of human serum albumin single-photon emission computed tomography/computed tomography (SPECT/CT), and the correlation to the post-therapeutic Yttrium90 positron emission tomography/computed tomography (PET/CT) in patients with selective internal radiation therapy (SIRT). (2) Methods: Between September 2013 and December 2016, 104 SIRT procedures were performed at our institution in 74 patients with HCC not suitable for curative surgery or ablation. Twenty-two patients underwent an identical sequence of pre-therapeutic MDCT, CACT, SPECT/CT, and post-therapeutic PET/CT with a standardized diagnostic and therapeutic protocol. In these 22 patients, 25 SIRT procedures were evaluated. The uptake of the HCC was assessed using tumor-background ratio (TBR). Therefore, regions of interest were placed on the tumor and the adjacent liver tissue on MDCT (TBRMDCT), CACT (TBRCACT), SPECT/CT (TBRSPECT/CT), and PET/CT (TBRPET/CT). Comparisons were made with the Friedman test and the Nemenyi post-hoc test. Correlations were analyzed using Spearman's Rho and the Benjamini-Hochberg method. The level of significance was p < 0.05. (3) Results: TBR on MDCT (1.4 ± 0.3) was significantly smaller than on CACT (1.9 ± 0.6) and both were significantly smaller compared to SPECT/CT (4.6 ± 2.0) (pFriedman-Test < 0.001; pTBRMDCT/TBRCACT = 0.012, pTBRMDCT/TBRSPECT/CT < 0.001, pTBRCACT/TBRSPECT/CT < 0.001). There was no significant correlation of TBR on MDCT with PET/CT (rTBRMDCT/TBRPET/CT = 0.116; p = 0.534). In contrast, TBR on CACT correlated to TBR on SPECT/CT (rTBRCACT/TBRSPECT/CT = 0.489; p = 0.004) and tended to correlate to TBR on PET/CT (rTBRCACT/TBRPET/CT =0.365; p = 0.043). TBR on SPECT/CT correlated to TBR on PET/CT (rTBRSPECT/CT/TBRPET/CT = 0.706; p < 0.001) (4) Conclusion: The uptake assessment on CACT was in agreement with SPECT/CT and might be consistent with PET/CT. In contrast, MDCT was not comparable to CACT and SPECT/CT, and had no correlation with PET/CT due to the different application techniques. This emphasizes the value of the CACT, which has the potential to improve the dosimetric assessment of the tumor and liver uptake for SIRT.

8.
Nuklearmedizin ; 55(4): 172-5, 2016 Aug 05.
Artigo em Alemão | MEDLINE | ID: mdl-27080701

RESUMO

UNLABELLED: Dose calibrators are one of the most important and most frequently used instruments for the determination of activities in nuclear medicine. For guaranteeing a constant quality of the dose calibrators' measurements, constancy checks including the examination of the system linearity have to be performed regularly, usually measured using 99mTc. The 99mTc eluate extracted from a 99Mo/99mTc generator is contaminated with molybdenum. Not accounting for the molybdenum impurity might lead to an exceed of the tolerance limit of 5% deviation to the reference value for this constancy check. The reason for this effect is the contamination of the 99mTc eluate with 99Mo, whose impact depends on both the amount of the impurity and on the total measurement time (high start activities). RESULT: In this work, the influence of the molybdenum impurity on the results of the constancy check of the system linearity was investigated and maximum start activities for certain impurities were determined providing that the deviation to the reference values is below 5%. CONCLUSION: Provided that certain boundary conditions are observed, a correction of the results with respect to the molybdenum contamination is not necessary.


Assuntos
Contaminação de Medicamentos , Molibdênio/análise , Radiometria/instrumentação , Radiometria/normas , Tecnécio/análise , Tecnécio/química , Calibragem/normas , Desenho de Equipamento , Análise de Falha de Equipamento , Alemanha , Molibdênio/química , Medicina Nuclear/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA