Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Ultrasonics ; 138: 107221, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38134514

RESUMO

It is shown herein that Perrot et al., who reviewed delay-and-sum beamforming for ultrafast ultrasound imaging in [Ultrasonics 111 (2021) 106309], misinterpreted the purpose of dynamic receive apertures. Such apertures widen with the focal length as a function of a given f-number and improve the image quality by suppressing grating lobes. Perrot et al., however, attributed erroneously the image quality improvement to suppression of measurement noise and, in doing so, proposed a suboptimal method to determine an f-number.

2.
Artigo em Inglês | MEDLINE | ID: mdl-37399162

RESUMO

Ultrafast imaging modes, such as coherent plane-wave compounding (CPWC), increase image uniformity and reduce grating lobe artifacts by dynamic receive apertures. The focal length and the desired aperture width maintain a given ratio, which is called the F -number. Fixed F -numbers, however, exclude useful low-frequency components from the focusing and reduce the lateral resolution. Herein, this reduction is avoided by a frequency-dependent F -number. This F -number derives from the far-field directivity pattern of a focused aperture and can be expressed in closed form. The F -number, at low frequencies, widens the aperture to improve the lateral resolution. The F -number, at high frequencies, narrows the aperture to avoid lobe overlaps and suppress grating lobes. Phantom and in vivo experiments with a Fourier-domain beamforming algorithm validated the proposed F -number in CPWC. The lateral resolution, which was measured by the median lateral full-widths at half-maximum of wires, improved by up to 46.8% and 14.9% in a wire and a tissue phantom, respectively, in comparison to fixed F -numbers. Grating lobe artifacts, which were measured by the median peak signal-to-noise ratios of wires, reduced by up to 9.9 dB in comparison to the full aperture. The proposed F -number thus outperformed F -numbers that were recently derived from the directivity of the array elements.

3.
Opt Express ; 18(9): 9076-87, 2010 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-20588755

RESUMO

We present a method to speed up the acquisition of multispectral photoacoustic data sets by using unipolar orthogonal Golay codes as excitation sequences for the irradiation system. Multispectral photoacoustic coded excitation (MS-PACE) allows acquiring photoacoustic data sets for two irradiation wavelengths simultaneously and separating them afterwards, thus improving the SNR or speeding up the measurement. We derive an analytical estimation of the SNR improvement using MS-PACE compared to time equivalent averaging. We demonstrate the feasibility of the method by successfully imaging a phantom composed of two dyes using unipolar orthogonal Golay codes as excitation sequence for two high power laser diodes operating at two different wavelengths. The experimental results show very good agreement with the theoretical predictions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA