1.
J Cardiovasc Electrophysiol ; 30(12): 2877-2884, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31646695

RESUMO

BACKGROUND: Contemporary implantable cardioverter-defibrillator (ICD) programming involving delayed high-rate detection and use of supraventricular tachycardia (SVT) discriminators has significantly reduced the rate of inappropriate shocks. The extent to which SVT algorithms alone reduce inappropriate therapies is poorly understood. METHODS AND RESULTS: PainFree SST enrolled 2770 patients with a single- or dual-chamber ICD or cardiac resynchronization defibrillator. Patients were followed for 22 ± 9 months with SVT discriminators on in 96% of patients. Sustained ventricular tachyarrhythmias and SVT episodes were adjudicated by an independent physician committee. For this analysis, all episodes were subjected to postprocessing computer simulation with SVT discriminators off with and without delayed high-rate detection criteria (ventricular fibrillation zone only, 30/40 at 320 ms). There were 3282 adjudicated SVT episodes of which 115 resulted in an ICD shock and 113 received only ATP (2-year inappropriate shock and therapy rates of 3.1% and 4.1%). Therapy was appropriately withheld for the remaining 3054 SVT episodes. With both SVT discriminators and delayed high-rate detection simulated off, the 2-year inappropriate therapy rate would have been 22.9% (hazard ratio [HR] = 6.24; 95% confidence interval [CI]: 5.20-7.49). With SVT discriminators simulated off and delayed high-rate detection simulated on in all patients, the 2-year rate would have been 6.4% (HR = 1.63; CI: 1.44-1.85). CONCLUSIONS: The use of SVT discriminators has a significant role in reducing the rate of inappropriate ICD therapy even in the setting of delayed high-rate detection settings. Deactivating SVT discriminators would have resulted in an overall increase in the inappropriate ICD therapy rate by 63% and 524% with and without delayed high-rate detection programming, respectively.


Assuntos
Algoritmos , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Falha de Prótese , Processamento de Sinais Assistido por Computador , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Taquicardia Supraventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/fisiopatologia
2.
Pacing Clin Electrophysiol ; 42(2): 132-138, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30478983

RESUMO

BACKGROUND: Atrial arrhythmias are associated with major adverse cardiovascular events. Recent reports among implantable cardioverter defibrillator (ICD) patients have demonstrated a high prevalence of atrial fibrillation (AF), predominantly in dual-chamber recipients. AF incidence among patients with single-chamber systems (approximately 50% of all ICDs) is currently unknown. The objective was to estimate the prevalence of new-onset AF among single-chamber ICD patients by observing the rates of new atrial tachycardia (AT)/AF among a propensity scoring matched cohort of dual-chamber ICD patients from the PainFree SmartShock technology study, to better inform screening initiatives. METHODS: Among 2770 patients enrolled, 1862 single-chamber, dual-chamber, and cardiac resynchronization therapy subjects with no prior history of atrial tachyarrhythmias were included. Daily AT/AF burden was estimated using a propensity score weighted model against data from dual-chamber ICDs. RESULTS: Over 22 ± 9 months of follow-up, the estimated incidence of AT/AF-lasting at least 6 min, 6 h, and 24 h per day -in the single-chamber cohort was 22.0, 9.8, and 6.3%, whereas among dual-chamber patients, the prevalence was 26.6, 13.1, and 7.1%, respectively. Initiation of oral anticoagulation was estimated to occur in 9.8% of the propensity matched single-chamber cohort, which was higher than the actual observed rate of 6.0%. Stroke and transient ischemic attack occurred at low rates in all device subgroups. CONCLUSIONS: Atrial arrhythmias occur frequently, and significant underutilization of anticoagulation is suggested in single-chamber ICD recipients. Routine screening for AF should be considered among single-chamber ICD recipients.


Assuntos
Fibrilação Atrial/epidemiologia , Desfibriladores Implantáveis , Complicações Pós-Operatórias/epidemiologia , Idoso , Estudos de Coortes , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Desenho de Prótese
3.
Pacing Clin Electrophysiol ; 41(9): 1185-1191, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29928759

RESUMO

BACKGROUND: The PainFree Smart Shock Technology (SST) study showed a low implantable cardioverter-defibrillator (ICD) inappropriate shock rate. However, the majority of patients were from Western countries with patient characteristics different from those in Japan. ICD shock rates using the novel SST algorithms in Japanese patients are still unknown. METHODS: All 2,770 patients in the PainFree SST study (Japan [JPN]: N = 181, other geographies [OJPN]: N = 2,589) were included in this analysis. RESULTS: Japanese patients had higher average left ventricular ejection fraction (P < 0.0001), higher prevalence of secondary prevention indications (P < 0.0001), nonischemic cardiomyopathy (P < 0.0001), and permanent atrial fibrillation (P < 0.0001). The appropriate shock rate at 12 months was not different between JPN and OJPN: 6.4% and 6.3%, respectively (P = 0.95). The inappropriate shock rate at 12 months was significantly higher in Japanese patients (2.9% vs 1.7%, P = 0.017). However, after propensity score matching to adjust for the difference in baseline characteristics, the difference in inappropriate shock rate was not statistically significant (P = 0.51). CONCLUSIONS: There was no difference in the appropriate shock rate between Japan and other geographies. The inappropriate shock rate in Japan was low, although it was slightly higher compared to other geographies due to baseline characteristics, including a higher prevalence of permanent AF. There was not a statistically significant difference after adjusting for baseline characteristics.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica , Idoso , Algoritmos , Desfibriladores Implantáveis , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Medição da Dor , Pontuação de Propensão , Estudos Prospectivos
4.
Europace ; 19(12): 1973-1980, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28340005

RESUMO

AIMS: Single-chamber (VR-ICD) and subcutaneous (S-ICD) implantable cardioverter-defibrillators are effective to protect patients against sudden death but expose them to higher risk of inappropriate shock (IS). We sought to quantify the annual rate and influencing factors of ISs in VR- and S-ICDs from the literature. METHODS AND RESULTS: PubMed, Embase, and Cochrane Library were searched for full text articles with IS rates. Poisson distribution estimated proportion of patients with ISs; rates were annualized based on follow-up duration. Random effects meta-analysis accounted for study-to-study variation. Out of 3264 articles, 16 qualified for the meta-analysis. Across studies, 6.4% [95% confidence interval (CI) 5.1-7.9%] of patients received an IS per year. Meta-regression analyses demonstrated that IS rates were lower in more recent studies [rate ratio (RR) per year: 0.93, 95% CI: 0.87-0.98; P = 0.01] and trended lower in studies with longer follow-up (RR per year: 0.78, 95% CI: 0.60-1.01; P = 0.06). Use of S-ICDs (RR: 1.81, 95% CI: 0.86-3.81; P = 0.12) and ventricular tachycardia zone programmed on (RR: 1.13, 95% CI: 0.65-1.97; P = 0.66) were not associated with a significantly increased change in risk. The IS rate observed in one of the more recent studies was significantly lower than predicted after accounting for covariates (RR: 0.29, 95% CI: 0.14-0.60; P < 0.001). CONCLUSIONS: A comprehensive review of the literature shows that 6.4% of patients with ICDs experienced their first IS annually. One of the 16 studies was better than predicted with the lowest reported rate (1.9%) and could not be explained by timing of the study or other covariates.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Falha de Prótese , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/mortalidade , Estimulação Elétrica , Humanos , Razão de Chances , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
Pacing Clin Electrophysiol ; 38(12): 1464-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26412309

RESUMO

BACKGROUND: Insertable cardiac monitors (ICMs) are used to continuously monitor the patient's electrocardiogram. In response to patient activation or based on automated device algorithms, arrhythmia episodes are stored and automatically transmitted daily to the clinician. Thus, ICMs can be used to diagnose arrhythmias in at-risk patients and in those with symptoms potentially attributable to arrhythmias. The ICM described in this report has undergone a dramatic change in size and method of insertion. METHODS: To evaluate the safety profile of the ICM procedure, we analyzed procedure-related adverse events (AEs) from two separate trials: A controlled, nonrandomized multicenter study (Reveal LINQ(TM) Usability study) and a multicenter registry (Reveal LINQ(TM) Registry) evaluating real-world experience. For the Registry we reported all procedure-related AEs upon occurrence, whereas for the Usability study, we reported events occurring during the first month of follow-up. RESULTS: The Usability study enrolled 151 patients (age 56.6 ± 12.1 years; male 67%) at 16 centers; during follow-up, an infection was observed in 1.3% patients and a procedure-related serious AE (SAE) in 0.7% patients. The Registry enrolled 122 patients (age 61.0 ± 17.8 years; male 47%) at seven centers; during follow-up, an infection was observed in 1.6% patients and a procedure-related SAE in 1.6% patients. CONCLUSIONS: The cumulative experience from a controlled clinical trial and a "real-world" registry demonstrate that the new ICM can be inserted with very low incidence of AEs.


Assuntos
Eletrocardiografia Ambulatorial/estatística & dados numéricos , Dor Pós-Operatória/epidemiologia , Próteses e Implantes/estatística & dados numéricos , Implantação de Prótese/estatística & dados numéricos , Infecções Relacionadas à Prótese/epidemiologia , Infecção da Ferida Cirúrgica/epidemiologia , Desenho de Equipamento , Análise de Falha de Equipamento , Segurança de Equipamentos/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miniaturização , Estudos Prospectivos
6.
Heart Rhythm ; 20(2): 190-197, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36272710

RESUMO

BACKGROUND: Antitachycardia pacing (ATP) is an established implantable cardioverter-defibrillator (ICD) therapy that terminates ventricular tachycardias (VTs) without painful ICD shocks. However, factors influencing ATP success are not well understood. OBJECTIVE: The purpose of this study was to examine ATP success rates by patient, device, and programming characteristics. METHODS: This retrospective analysis of the PainFree SmartShock Technology study included spontaneous ATP-treated monomorphic VT episodes. ATP success rates were calculated for various factors. Also, the relationship of ATP programming on shock burden and syncope were investigated. RESULTS: Of the 2770 enrolled patients (2200 [79%] male; mean age 65 years), 1699 (61%) received an ICD and 1071 (39%) a cardiac resynchronization therapy - defibrillator. ATP had >80% rate of success for terminating VTs overall, with similar rates observed between ICD and cardiac resynchronization therapy - defibrillator devices (82.2% vs 80.3%, respectively; P = .81) as well as between primary and secondary prevention patients with ICDs (77.2% vs 83.9% respectively; P = .25). Arrhythmias with a median cycle length of ≥320 ms had a significantly higher ATP success rate (88.0%; 95% confidence interval 84.8%-90.6%). The cumulative percentage of ATP success increased from 71% at 1 ATP sequence delivered to 87% at ≥8 sequences delivered. Programming more ATP sequences was associated with lower shock burden (P = .0005). There was no evidence that more sequences were associated with higher rates of syncope (P = .16). CONCLUSION: Delivering more ATP sequences resulted in a higher overall success of terminating VTs, while programming more ATP was associated with decreased shock burden and no evidence of increased syncope or acceleration. This suggests that more ATP sequences should be programmed when possible, but confirmation in prospective studies will be necessary.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Masculino , Idoso , Feminino , Estudos Prospectivos , Estudos Retrospectivos , Síncope/terapia , Trifosfato de Adenosina , Resultado do Tratamento
7.
Int J Cardiol ; 350: 36-40, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34998948

RESUMO

BACKGROUND: Patients with inherited arrhythmogenic diseases (IADs) are often prescribed preventative implantable cardioverter-defibrillators (ICDs) to manage their increased sudden cardiac arrest risk. However, it has been suggested that ICDs in IAD patients may come with additional risk. We aimed to leverage the PainFree SmartShock Technology dataset to compare inappropriate therapies, appropriate therapies, mortality, and complications in patients with and without IAD. METHODS: This retrospective analysis included extracted, physician-adjudicated, arrhythmic episodes from ICD devices. The incidence of arrhythmic events was estimated with the Kaplan-Meier method using the log-rank test. Cox proportional hazards regression was used to estimate hazard ratios (HRs) with their 95% confidence intervals (CIs). RESULTS: Of the 1699 ICD patients, 77 patients (4.5%) had IAD. Incidence of inappropriate shock was similar in both patients with (3.2% at 24 months) and without (3.8% at 24 months) IAD (HR: 0.80, CI: 0.19-3.30, p = 0.76). In a multivariable analysis IAD was not significantly associated with reduced mortality (HR: 0.64, CI: 0.08-4.80, p = 0.66). The rates of complications were numerically lower in patients with IAD vs without (8.8% vs 9.6% at 24 months respectively), but not statistically significant (HR: 0.83, CI: 0.20-3.38, p = 0.79). CONCLUSIONS: IAD patients showed a very low annual rate of inappropriate therapy. This suggests that newer algorithms, such as the SST algorithm, are equally good at identifying and treating life-threatening arrhythmias in patients regardless of whether they have IAD.


Assuntos
Desfibriladores Implantáveis , Arritmias Cardíacas/etiologia , Morte Súbita Cardíaca/epidemiologia , Desfibriladores Implantáveis/efeitos adversos , Humanos , Estudos Retrospectivos , Fatores de Risco , Tecnologia , Resultado do Tratamento
8.
Circ Arrhythm Electrophysiol ; 15(8): e011029, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35925831

RESUMO

BACKGROUND: Lead dislodgement (LD) has been one of the most common early complications after cardiovascular implantable electronic device implant. However, limited data are available on the clinical characteristics and long-term outcomes of LD events. The aim of this study was to examine the risk factors, clinical significance, and management strategies of LD events after cardiovascular implantable electronic device implant. METHODS: This study was a retrospective cohort analysis of 20 683 patients who underwent cardiovascular implantable electronic device implant between January 1, 2010 and January 31, 2020 in Medtronic's Product Surveillance Registry, with a mean follow-up time of 3.3±2.5 SD years. The study population was divided into 2 groups: group A with LD events (N=350) and group B without LD events (N=20 333). RESULTS: During this period, 350 patients (1.69%) had LD events involving 371 leads (0.95%), among a total of 39 060 leads implanted. Passive fixation type (right atrium pacing lead, P=0.041), lower sensing amplitude (right ventricle defibrillating lead, P=0.020), and lower lead impedance at implant (right atrium pacing lead, P=0.009) were associated with increased LD risk. Multivariate analysis showed female sex (hazard ratio, 1.520, P=0.008) and higher body mass index (hazard ratio, 1.012, P=0.001) were independently associated with increased risk of LD events. LD events were not associated with significant changes in the long-term risks of cardiac and overall mortality. In group A, repositioning the dislodged leads increased the risk of a second LD event compared with implanting new leads (P=0.012). CONCLUSIONS: Female sex and higher body mass index were associated with higher risk of LD events in the Product Surveillance Registry. Among patients with dislodged leads, implanting new leads was associated with lower risk of future LD events. Further studies on how to reduce LD risk and to improve management of these events are needed. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01524276.


Assuntos
Desfibriladores Implantáveis , Desfibriladores Implantáveis/efeitos adversos , Feminino , Ventrículos do Coração , Humanos , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco
9.
Int J Cardiol ; 335: 73-79, 2021 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-33812951

RESUMO

BACKGROUND: Lower BiVentricular (BiV) pacing percentages have been associated with significantly worse survival in patients with chronic heart failure (HF). However, the pathophysiology behind this observation has not been further delineated. This analysis evaluated whether small incremental decreases in BiV pacing percentages were associated with worse measures, related to HF physiology using individual sensor trends and the HeartLogic composite index. METHODS: Sensor data was obtained from 900 ambulatory HF patients with implanted CRT devices. The percent of cardiac cycles with BiV pacing was assessed for periods (median = 7.3 days) between data downloads (median = 55 periods/patient). RESULTS: The third heart sound (S3), respiration rate, RSBI, and night-time heart rate were significantly elevated with sub-optimal pacing (<98%), while the first heart sound (S1), thoracic impedance, and activity were significantly lower. All sensor changes were in the direction associated with worsening HF. While IN the HeartLogic alert state (threshold above an Index of 16) the odds of optimal BiV pacing (≥98%) were less than when OUT of the HeartLogic alert state for a given subject (OR: 0.655; 95% CI: 0.626-0.686; p < 0.0001). The percent BiV pacing was reduced and the HeartLogic Index was increased in the periods surrounding HFhospitalizations. CONCLUSION: Lower BiV pacing percent is associated with multiple sensor changes indicative of worsening HF, and patients in HeartLogic alert are more likely to have suboptimal BiV pacing. Collectively, these data provide strong evidence that even small decreases in BiV percent pacing can lead to worsening HF.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Benchmarking , Estimulação Cardíaca Artificial , Desfibriladores , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Frequência Cardíaca , Humanos , Resultado do Tratamento
10.
Circ Arrhythm Electrophysiol ; 13(10): e008503, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32915063

RESUMO

BACKGROUND: In the WRAP-IT trial (Worldwide Randomized Antibiotic Envelope Infection Prevention), adjunctive use of an absorbable antibacterial envelope resulted in a 40% reduction of major cardiac implantable electronic device infection without increased risk of complication in 6983 patients undergoing cardiac implantable electronic device revision, replacement, upgrade, or initial cardiac resynchronization therapy defibrillator implant. There is limited information on the cost-effectiveness of this strategy. As a prespecified objective, we evaluated antibacterial envelope cost-effectiveness compared with standard-of-care infection prevention strategies in the US healthcare system. METHODS: A decision tree model was used to compare costs and outcomes of antibacterial envelope (TYRX) use adjunctive to standard-of-care infection prevention versus standard-of-care alone over a lifelong time horizon. The analysis was performed from an integrated payer-provider network perspective. Infection rates, antibacterial envelope effectiveness, infection treatment costs and patterns, infection-related mortality, and utility estimates were obtained from the WRAP-IT trial. Life expectancy and long-term costs associated with device replacement, follow-up, and healthcare utilization were sourced from the literature. Costs and quality-adjusted life years were discounted at 3%. An upper willingness-to-pay threshold of $150 000 per quality-adjusted life year was used to determine cost-effectiveness, in alignment with the American College of Cardiology/American Heart Association practice guidelines and as supported by the World Health Organization and contemporary literature. RESULTS: The base case incremental cost-effectiveness ratio of the antibacterial envelope compared with standard-of-care was $112 603/quality-adjusted life year. The incremental cost-effectiveness ratio remained lower than the willingness-to-pay threshold in 74% of iterations in the probabilistic sensitivity analysis and was most sensitive to the following model inputs: infection-related mortality, life expectancy, and infection cost. CONCLUSIONS: The absorbable antibacterial envelope was associated with a cost-effectiveness ratio below contemporary benchmarks in the WRAP-IT patient population, suggesting that the envelope provides value for the US healthcare system by reducing the incidence of cardiac implantable electronic device infection. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02277990.


Assuntos
Antibacterianos/economia , Antibioticoprofilaxia/economia , Dispositivos de Terapia de Ressincronização Cardíaca/economia , Desfibriladores Implantáveis/economia , Custos de Medicamentos , Implantação de Prótese/economia , Infecções Relacionadas à Prótese/economia , Implantes Absorvíveis/economia , Antibacterianos/uso terapêutico , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Tomada de Decisão Clínica , Redução de Custos , Análise Custo-Benefício , Árvores de Decisões , Desfibriladores Implantáveis/efeitos adversos , Humanos , Modelos Econômicos , Estudos Multicêntricos como Assunto , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/prevenção & controle , Qualidade de Vida , Anos de Vida Ajustados por Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
11.
Heart Rhythm ; 16(8): 1215-1222, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30772531

RESUMO

BACKGROUND: Internal insulation breaches (IBR) may result in implantable cardioverter-defibrillator lead failure and adverse clinical events. Concerns exist that the Durata lead may be prone to IBR. OBJECTIVE: The goals of this study were to assess Durata failures in the Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) database and compare them to failures in MAUDE for Endotak Reliance and Sprint Quattro Secure (QS) leads. METHODS: We searched the MAUDE database from 2008 to 2018 for IBR and other failure modes. Included were explanted leads whose manufacturers found an insulation or conductor defect not caused by extrinsic factors. RESULTS: The MAUDE search found 1011 qualifying leads. The cause of failure differed among leads (P < .001). The primary cause of Durata failure was IBR (293 of 316 leads [93%]), with IBR accounting for 47% (137 of 293); few QS (9 of 523 [1.7%]) and no Endotak Reliance leads failed because of IBR (P < .001). Durata IBR were responsible for 11 failures to treat ventricular tachycardia/ventricular fibrillation, and all were caused by high-voltage (HV) shorts between the proximal superior vena cava coil and a distal right ventricular coil cable (n = 10) or sensing conductor (n = 1); low values of HV impedance were found in these leads during defibrillation threshold testing (n = 3), after a shock or aborted shock (n = 7), and by an alert (n = 1). Inappropriate therapy was caused by 51 Durata IBR, but no QS IBR. CONCLUSION: Durata implantable cardioverter-defibrillator leads are susceptible to IBR that may result in failure to treat ventricular tachycardia/ventricular fibrillation or inappropriate therapy; such failures may occur without forewarning. HV testing of Durata leads may be indicated during pulse generator replacement or when an insulation defect is suspected.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Sistema de Condução Cardíaco/fisiopatologia , Arritmias Cardíacas/fisiopatologia , Desenho de Equipamento , Falha de Equipamento , Feminino , Humanos , Masculino , Estudos Retrospectivos
13.
Heart Rhythm ; 15(5): 734-740, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29277687

RESUMO

BACKGROUND: The effect of implantable cardioverter-defibrillator (ICD) shock on device-measured activity and patient-reported outcomes is unknown. OBJECTIVE: The purpose of this study was to analyze the acute and long-term effects of ICD shock on objective behavioral data (ie, device-based physical activity) and subjective patient-reported outcomes (eg, quality of life and shock anxiety). METHODS: The PainFree Smart Shock Technology (SST) clinical trial included 2770 patients with a single- or dual-chamber ICD or cardiac resynchronization therapy - defibrillator device who were followed for 22 ± 9 months. Participants completed measures of quality of life (EuroQol-5D [EQ-5D] questionnaire) and shock anxiety (Florida Shock Anxiety Scale) at baseline, biannual visits, and monthly for 6 months after an ICD shock. Daily physical activity data were obtained from a built-in device accelerometer. RESULTS: The average daily activity was 185.3 ± 119.4 min/d. Activity was significantly reduced after an ICD shock (P < .0001) and recovered to a normal level after ∼90 days. An ICD shock was also associated with decreased quality of life (EQ5-D health score) and increased EQ-5D anxiety scores, but it did not affect mobility, self-care, activity, or pain. Similarly, shock anxiety (Florida Shock Anxiety Scale) increased in shocked patients and remained significantly elevated at 24 months, regardless of appropriate or inappropriate shock delivery. CONCLUSION: ICD shocks have a long-lasting adverse effect on both objective, device-measured physical activity and subjective patient-reported outcomes of quality of life and shock anxiety. Successful management of patients with an ICD requires attention to clinically relevant behavioral and psychological outcomes to expedite recovery and return to activities of daily living.


Assuntos
Ansiedade/etiologia , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Exercício Físico/fisiologia , Dor/etiologia , Qualidade de Vida , Acelerometria , Idoso , Ansiedade/psicologia , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/psicologia , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Dor/psicologia , Estudos Prospectivos , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
15.
Arch Intern Med ; 166(20): 2228-33, 2006 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-17101941

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) have been shown in primary prevention efficacy trials to reduce mortality in patients with ischemic heart disease and left ventricular dysfunction. To investigate the generalizabilty of this mortality reduction, we examined the effectiveness of ICDs in clinical practice. METHODS: We developed a prospective multicenter cohort of 770 patients with ischemic left ventricular dysfunction (ejection fraction < or =35%) and without a history of ventricular arrhythmia, of whom 395 (52%) received ICDs. Mean +/- SD follow-up was 27 +/- 12 months. We assessed the degree to which ICDs decreased mortality risk using Cox proportional hazards analyses that controlled for clinical predictors of death, receipt of ICD (a propensity score analysis), and predictors of arrhythmic death (including electrophysiologic variables). RESULTS: Multivariate Cox analyses showed that those with ICDs had significantly lower all-cause mortality (hazard ratio [HR], 0.53; 95% confidence interval [CI], 0.33-0.86). This mortality reduction was mediated through dramatically lower arrhythmia-related mortality (HR, 0.35; 95% CI, 0.17-0.73), with no significant effect on cardiovascular nonarrhythmic (HR, 0.81; 95% CI, 0.34-1.96) and noncardiovascular (HR, 0.76; 95% CI, 0.29-2.05) mortality. No differences were found between the ICD and non-ICD groups for a composite outcome of all-cause mortality, appropriate ICD shocks, or documented symptomatic ventricular arrhythmia, which suggests that the 2 groups had similar baseline risk for life-threatening arrhythmic events (HR, 0.96; 95% CI, 0.63-1.45). CONCLUSION: In clinical practice, ICDs appear to reduce all-cause and arrhythmic rates of mortality at levels similar to those found in primary prevention trials.


Assuntos
Desfibriladores Implantáveis , Isquemia Miocárdica/terapia , Disfunção Ventricular Esquerda/terapia , Idoso , Distribuição de Qui-Quadrado , Feminino , Humanos , Masculino , Isquemia Miocárdica/mortalidade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Taxa de Sobrevida , Resultado do Tratamento , Disfunção Ventricular Esquerda/mortalidade
16.
J Interv Card Electrophysiol ; 47(1): 37-43, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26956986

RESUMO

PURPOSE: Recent changes to medical specialty certification in the USA have prompted the process to come under intense scrutiny. METHODS: We review the history of board certification and the changes made to the process. As part of this review, we examine both literature and public record to examine the motives behind the changes made. We then review the legal challenges and changes under way to modify the current ABMS board re-certification process. RESULTS: In 1917, the first board certification was a lifetime designation, voluntary, and managed by unpaid board members with a focus to enhance quality for patients. Corresponding to the implementation of time-limited certification, $55 million of physician testing fees were transferred from the American Board of Internal Medicine to its Foundation between 1989 and 1999. From 2000 through 2007, and additional $20.66 million were transferred from the ABIM to its Foundation culminating in the purchase of a $2.3 million luxury condominium in December 2007. CONCLUSIONS: Significant financial conflicts of interest for the implementation of time-limited specialty certification exited and continue to plague the medical profession. The specialty boards and the organizations that created them should remove all requirements for time-limited board certification and resort to conventional self-selected ACGME-approved CME programs for ongoing education.


Assuntos
Certificação/normas , Competência Clínica/normas , Avaliação Educacional/normas , Guias como Assunto , Medicina/normas , Conselhos de Especialidade Profissional/normas , Membro de Comitê , Estados Unidos
17.
Heart Rhythm ; 13(7): 1489-96, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26988379

RESUMO

BACKGROUND: Prolonged ventricular fibrillation (VF) detection has been shown to reduce implantable cardioverter-defibrillator (ICD) therapies and improve prognosis in primary prevention ICD patients. Data in secondary prevention patients are limited. OBJECTIVE: The PainFree SST secondary prevention study is the largest trial of secondary prevention patients randomized between standard and prolonged detection to assess the safety of this strategy in these patients. METHODS: A total of 705 secondary prevention patients implanted with an ICD in the PainFree SST trial were enrolled in this substudy; 353 patients were randomized to VF detection of 18/24 intervals and 352 patients to 30/40. All other VF parameters were standardized by protocol. RESULTS: The 1-year arrhythmic syncope-free rates in the standard and prolonged groups were 97.7% vs 96.9%, respectively, (P = .0034 for noninferiority). Freedom from all-cause syncope was 96% in both arms (P = .0013 for noninferiority). There was no difference in the time to first appropriate or inappropriate VF therapy. However, the rates of treated VF episodes were lower in the prolonged arm (1.48 per patient per year vs 0.44 per patient per year, P = .0001). A trend toward lower mortality in the prolonged group was not statistically different (5.6% 1 year, 12% 2 years vs 3.8% 1 year, 7.7% 2 years, adjusted hazard ratio = 0.60, P = .061). CONCLUSION: This large prospective randomized study shows that prolonged detection can safely be programmed in secondary prevention ICD patients with new or existing devices. This programming strategy decreases the rate of treated events and is not associated with an increased risk of syncope or mortality.


Assuntos
Cardioversão Elétrica , Dor , Prevenção Secundária , Síncope , Fibrilação Ventricular , Idoso , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Desfibriladores Implantáveis/estatística & dados numéricos , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Dor/etiologia , Dor/prevenção & controle , Prognóstico , Prevenção Secundária/métodos , Prevenção Secundária/estatística & dados numéricos , Análise de Sobrevida , Síncope/etiologia , Síncope/prevenção & controle , Fatores de Tempo , Fibrilação Ventricular/complicações , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/mortalidade , Fibrilação Ventricular/terapia
18.
Heart Rhythm ; 12(5): 926-36, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25637563

RESUMO

BACKGROUND: The benefits of implantable cardioverter-defibrillators (ICDs) have been well demonstrated in many clinical trials, and ICD shocks for ventricular tachyarrhythmias save lives. However, inappropriate and unnecessary shock delivery remains a significant clinical issue with considerable consequences for patients and the healthcare system. OBJECTIVE: The purpose of the PainFree SmartShock Technology (SST) study was to investigate new-generation ICDs to reduce inappropriate and unnecessary shocks through novel discrimination algorithms with modern programming strategies. METHODS: This prospective, multicenter clinical trial enrolled 2790 patients with approved indication for ICD implantation (79% male, mean age 65 years; 69% primary prevention indication, 27% single-chamber ICD, 33% replacement or upgrade). Patients were followed for a minimum of 12 months, and mean follow-up was 22 months. The primary end-point of the study was the percentage of patients remaining free of inappropriate shocks at 1 year postimplant, analyzed separately for dual/triple-chamber ICDs (N = 2019) and single-chamber ICDs (N = 751). RESULTS: The inappropriate shock rate at 1 year was 1.5% for patients with dual/triple-chamber ICDs and 2.5% for patients with single-chamber devices. Two years postimplant, the inappropriate shock rate was 2.8% for patients with dual-/triple chamber ICDs and 3.7% for those with single-chamber ICDs. The most common cause of an inappropriate shock in both groups was atrial fibrillation or flutter. CONCLUSION: In a large patient cohort receiving ICDs for primary or secondary prevention, the adoption of novel enhanced detection algorithms in conjunction with routine implementation of modern programming strategies led to a very low inappropriate shock rate.


Assuntos
Algoritmos , Morte Súbita Cardíaca , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica , Dor , Taquicardia Ventricular , Idoso , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/métodos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dor/etiologia , Dor/prevenção & controle , Prevenção Primária , Taquicardia Ventricular/complicações , Taquicardia Ventricular/terapia , Resultado do Tratamento
19.
Cardiol Clin ; 32(2): 293-8, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24793804

RESUMO

Initial studies established patient selection criteria for cardiac resynchronization therapy (CRT) as left ventricular ejection fraction less than or equal to 35%, QRS greater than or equal to 120 ms, and New York Heart Association 3-4. Based on newer data, post hoc analyses, and meta-analyses, these criteria have been refined and guidelines updated, highlighting left bundle branch morphology and QRS greater than 150 ms in selecting patients with a likelihood of favorable outcomes. Guidelines will change as more data become available; the decision to apply CRT should be based on patient clinical profile and the balance of risk tolerance and likelihood of benefit.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Bloqueio Atrioventricular/terapia , Ensaios Clínicos como Assunto , Insuficiência Cardíaca/fisiopatologia , Humanos , Infarto do Miocárdio/terapia , Seleção de Pacientes , Volume Sistólico/fisiologia
20.
Heart Rhythm ; 10(5): 685-91, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23333721

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) of pacemakers is a relative contraindication because of the risks to the patient from potentially hazardous interactions between the MRI and the pacemaker system. Chest scans (ie, cardiac magnetic resonance scans) are of particular importance and higher risk. The previously Food and Drug Administration-approved magnetic resonance conditional system includes positioning restrictions, limiting the powerful utility of MRI. OBJECTIVE: To confirm the safety and effectiveness of a pacemaker system designed for safe whole body MRI without MRI scan positioning restrictions. METHODS: Primary eligibility criteria included standard dual-chamber pacing indications. Patients (n = 263) were randomized in a 2:1 ratio to undergo 16 chest and head scans at 1.5 T between 9 and 12 weeks postimplant (n = 177) or to not undergo MRI (n = 86) post-implant. Evaluation of the pacemaker system occurred immediately before, during (monitoring), and after MRI, 1-week post-MRI, and 1-month post-MRI, and similarly for controls. Primary end points measured the MRI-related complication-free rate for safety and compared pacing capture threshold between MRI and control subjects for effectiveness. RESULTS: There were no MRI-related complications during or after MRI in subjects undergoing MRI (n = 148). Differences in pacing capture threshold values from pre-MRI to 1-month post-MRI were minimal and similar between the MRI and control groups. CONCLUSIONS: This randomized trial demonstrates that the Advisa MRI pulse generator and CapSureFix MRI 5086MRI lead system is safe and effective in the 1.5 T MRI environment without positioning restrictions for MRI scans or limitations of body parts scanned.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Marca-Passo Artificial/efeitos adversos , Idoso , Segurança de Equipamentos , Feminino , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Estudos Prospectivos , Resultado do Tratamento