Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Med Phys ; 51(2): 991-1006, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38150577

RESUMO

BACKGROUND: Simultaneous positron emission tomography (PET)/magnetic resonance imaging (MRI) scanners and inserts are valuable tools for accurate diagnosis, treatment planning, and monitoring due to their complementary information. However, the integration of a PET system into an MRI scanner presents technical challenges for a distortion-free operation. PURPOSE: We aim to develop a PET insert dedicated to breast imaging in combination with the 3T PET/MRI scanner Biograph mMR (Siemens Healthineers) as well as a brain PET insert for the 7T MRI scanner MAGNETOM Terra (Siemens Healthineers). For this development, we selected as a basis the C13500 series PET modules (Hamamatsu Photonics K.K.) as they offer an all-in-one solution with a scalable, modular design for compact integration with state-of-the-art performance. The original PET modules were not designed to be operated with an MRI scanner, therefore we implemented several modifications such as signal transmission via plastic optical fiber, radio frequency (RF) shielding of the front-end electronics, and filter for the power supply lines. In this work, we evaluated the mutual MRI compatibility between the modified PET modules and the 3T and 7T MRI scanner. METHODS: We used a proof-of-concept setup with two detectors to comprehensively evaluate a potential distortion of the performance of the modified PET modules whilst exposing them to a variety of MR sequences up to the peak operation conditions of the Biograph mMR. A method using the periodicity of the sequences to identify distortions of the PET events in the phase of RF pulse transmission was introduced. Vice versa, the potential distortion of the Biograph mMR was evaluated by vendor proprietary MRI compatibility test sequences. Afterwards, these studies were extended to the MAGNETOM Terra. RESULTS: No distortions were introduced by gradient field switching (field strength up to 20 mT/m at a slew rate of 66.0 T/ms-1 ). However, RF pulse transmission induced a reduction of the single event rate from 33.0 kcounts/s to 32.0 kcounts/s and a degradation of the coincidence resolution time from 251 to 299 ps. Further, the proposed method revealed artifacts in the energy and timing histograms. Finally, by using the front-end filters it was possible to prevent any RF pulse induced distortion of event rate, energy, or time stamps even for a 700° flip angle (45.5 µT) sequence. The evaluations to assess potential distortions of the MRI scanner showed that carefully designed RF shielding boxes for the PET modules were required to prevent distortion of the RF spectra. The increase in B0 field inhomogeneity of 0.254 ppm and local changes of the B1 field of 12.5% introduced by the PET modules did not qualitatively affect the MR imaging with a spin echo and MPRAGE sequence for the Biograph mMR and the MAGNETOM Terra, respectively. CONCLUSION: Our study demonstrates the feasibility of using a modified version of the PET modules in combination with 3T and 7T MRI scanners. Building upon the encouraging MRI compatibility results from our proof-of-concept detectors, we will proceed to develop PET inserts for breast and brain imaging using these modules.


Assuntos
Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Encéfalo , Ondas de Rádio
2.
Eur Radiol ; 22(8): 1776-88, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22752524

RESUMO

OBJECTIVES: Technical performance evaluation of a human brain PET/MRI system. METHODS: The magnetic field compatible positron emission tomography (PET) insert is based on avalanche photodiode (APD) arrays coupled with lutetium oxyorthosilicate (LSO) crystals and slip-fits into a slightly modified clinical 3-T MRI system. The mutual interference between the two imaging techniques was minimised by the careful design of the hardware to maintain the quality of the B (0) and B (1) field homogeneity. RESULTS: The signal-to-noise ratio (SNR) and the homogeneity of the MR images were minimally influenced by the presence of the PET. Measurements according to the Function Biomedical Informatics Research Network (FBIRN) protocol proved the combined system's ability to perform functional MRI (fMRI). The performance of the PET insert was evaluated according to the National Electrical Manufacturers Association (NEMA) standard. The noise equivalent count rate (NEC) peaked at 30.7 × 10(3) counts/s at 7.3 kBq/mL. The point source sensitivity was greater than 7 %. The spatial resolution in the centre field of view was less than 3 mm. Patient data sets clearly revealed a noticeably good PET and MR image quality. CONCLUSION: PET and MRI phantom tests and first patient data exhibit the device's potential for simultaneous multiparametric imaging. KEY POINTS: • Combination of PET and MRI is a new emerging imaging technology. • Evaluated brain PET/MRI enables uncompromised imaging performance. • PET/MRI aims to provide multiparametric imaging allowing acquisition of morphology and metabolism.


Assuntos
Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Mapeamento Encefálico/métodos , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador/métodos , Lutécio/farmacologia , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Silicatos/farmacologia
3.
IEEE Trans Med Imaging ; 39(11): 3268-3277, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-31899415

RESUMO

A novel technique, called augmented whole-body scanning via magnifying PET (AWSM-PET), that improves the sensitivity and lesion detectability of a PET scanner for whole-body imaging is proposed and evaluated. A Siemens Biograph Vision PET/CT scanner equipped with one or two high-resolution panel-detectors was simulated to study the effectiveness of AWSM-PET technology. The detector panels are located immediately outside the scanner's axial field-of-view (FOV). A detector panel contains 2 ×8 detector modules each consisting of 32 ×64 LSO crystals ( 1.0 ×1.0 ×10.0 mm3 each). A 22Na point source was stepped across the scanner's FOV axially to measure sensitivity profiles at different locations. An elliptical torso phantom containing 7×9 spherical lesions was imaged at different axial locations to mimic a multi-bed-position whole-body imaging protocol. Receiver operating characteristic (ROC) curves were analyzed to evaluate the improvement in lesion detectability by the AWSM-PET technology. Experimental validation was conducted using an existing flat-panel detector integrated with a Siemens Biograph 40 PET/CT scanner to image a torso phantom containing spherical lesions with diameters ranging from 3.3 to 11.4 mm. The contrast-recovery-coefficient (CRC) of the lesions was evaluated for the scanner with or without the AWSM-PET technology. Monte Carlo simulation shows 36%-42% improvement in system sensitivity by a dual-panel AWSM-PET device. The area under the ROC curve is 0.962 by a native scanner for the detection of 4 mm diameter lesions with 5:1 tumor-to-background activity concentration. It was improved to 0.977 and 0.991 with a single- and dual-panel AWSM-PET system, respectively. Experimental studies showed that the average CRC of 3.3 mm and 4.3 mm diameter tumors were improved from 2.8% and 4.2% to 7.9% and 11.0%, respectively, by a single-panel AWSM-PET device. With a high-sensitivity dual-panel device, the corresponding CRC can be further improved to 11.0% and 15.9%, respectively. The principle of the AWSM-PET technology has been developed and validated. Enhanced system sensitivity, CRC and tumor detectability were demonstrated by Monte Carlo simulations and imaging experiments. This technology may offer a cost-effective path to realize high-resolution whole-body PET imaging clinically.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Imagem Corporal Total , Método de Monte Carlo , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons
4.
Radiology ; 248(3): 1028-35, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18710991

RESUMO

The purpose of this study was to apply a magnetic resonance (MR) imaging-compatible positron emission tomographic (PET) detector technology for simultaneous MR/PET imaging of the human brain and skull base. The PET detector ring consists of lutetium oxyorthosilicate (LSO) scintillation crystals in combination with avalanche photodiodes (APDs) mounted in a clinical 3-T MR imager with use of the birdcage transmit/receive head coil. Following phantom studies, two patients were simultaneously examined by using fluorine 18 fluorodeoxyglucose (FDG) PET and MR imaging and spectroscopy. MR/PET data enabled accurate coregistration of morphologic and multifunctional information. Simultaneous MR/PET imaging is feasible in humans, opening up new possibilities for the emerging field of molecular imaging.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética/métodos , Técnica de Subtração , Estudos de Viabilidade , Humanos , Radiografia , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
J Nucl Med ; 59(6): 993-998, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29419483

RESUMO

We describe a long axial field-of-view (FOV) PET scanner for high-sensitivity and total-body imaging of nonhuman primates and present the physical performance and first phantom and animal imaging results. Methods: The mini-EXPLORER PET scanner was built using the components of a clinical scanner reconfigured with a detector ring diameter of 43.5 cm and an axial length of 45.7 cm. National Electrical Manufacturers Association (NEMA) NU-2 and NU-4 phantoms were used to measure sensitivity and count rate performance. Reconstructed spatial resolution was investigated by imaging a radially stepped point source and a Derenzo phantom. The effect of the wide acceptance angle was investigated by comparing performance with maximum acceptance angles of 14°-46°. Lastly, an initial assessment of the in vivo performance of the mini-EXPLORER was undertaken with a dynamic 18F-FDG nonhuman primate (rhesus monkey) imaging study. Results: The NU-2 total sensitivity was 5.0%, and the peak noise-equivalent count rate measured with the NU-4 monkey scatter phantom was 1,741 kcps, both obtained using the maximum acceptance angle (46°). The NU-4 scatter fraction was 16.5%, less than 1% higher than with a 14° acceptance angle. The reconstructed spatial resolution was approximately 3.0 mm at the center of the FOV, with a minor loss in axial spatial resolution (0.5 mm) when the acceptance angle increased from 14° to 46°. The rhesus monkey 18F-FDG study demonstrated the benefit of the high sensitivity of the mini-EXPLORER, including fast imaging (1-s early frames), excellent image quality (30-s and 5-min frames), and late-time-point imaging (18 h after injection), all obtained at a single bed position that captured the major organs of the rhesus monkey. Conclusion: This study demonstrated the physical performance and imaging capabilities of a long axial FOV PET scanner designed for high-sensitivity imaging of nonhuman primates. Further, the results of this study suggest that a wide acceptance angle can be used with a long axial FOV scanner to maximize sensitivity while introducing only minor trade-offs such as a small increase in scatter fraction and slightly degraded axial spatial resolution.


Assuntos
Tomografia por Emissão de Pósitrons/instrumentação , Animais , Desenho de Equipamento , Processamento de Imagem Assistida por Computador , Macaca mulatta
6.
Phys Med Biol ; 56(23): 7569-83, 2011 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-22086164

RESUMO

The main focus of our study is to investigate how the performance of digital timing methods is affected by sampling rate, anti-aliasing and signal interpolation filters. We used the Nyquist sampling theorem to address some basic questions such as what will be the minimum sampling frequencies? How accurate will the signal interpolation be? How do we validate the timing measurements? The preferred sampling rate would be as low as possible, considering the high cost and power consumption of high-speed analog-to-digital converters. However, when the sampling rate is too low, due to the aliasing effect, some artifacts are produced in the timing resolution estimations; the shape of the timing profile is distorted and the FWHM values of the profile fluctuate as the source location changes. Anti-aliasing filters are required in this case to avoid the artifacts, but the timing is degraded as a result. When the sampling rate is marginally over the Nyquist rate, a proper signal interpolation is important. A sharp roll-off (higher order) filter is required to separate the baseband signal from its replicates to avoid the aliasing, but in return the computation will be higher. We demonstrated the analysis through a digital timing study using fast LSO scintillation crystals as used in time-of-flight PET scanners. From the study, we observed that there is no significant timing resolution degradation down to 1.3 Ghz sampling frequency, and the computation requirement for the signal interpolation is reasonably low. A so-called sliding test is proposed as a validation tool checking constant timing resolution behavior of a given timing pick-off method regardless of the source location change. Lastly, the performance comparison for several digital timing methods is also shown.


Assuntos
Processamento de Sinais Assistido por Computador , Algoritmos , Artefatos , Reprodutibilidade dos Testes , Fatores de Tempo
7.
J Nucl Med ; 52(1): 154-61, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21189415

RESUMO

UNLABELLED: Head motion is difficult to avoid in long PET studies, degrading the image quality and offsetting the benefit of using a high-resolution scanner. As a potential solution in an integrated MR-PET scanner, the simultaneously acquired MRI data can be used for motion tracking. In this work, a novel algorithm for data processing and rigid-body motion correction (MC) for the MRI-compatible BrainPET prototype scanner is described, and proof-of-principle phantom and human studies are presented. METHODS: To account for motion, the PET prompt and random coincidences and sensitivity data for postnormalization were processed in the line-of-response (LOR) space according to the MRI-derived motion estimates. The processing time on the standard BrainPET workstation is approximately 16 s for each motion estimate. After rebinning in the sinogram space, the motion corrected data were summed, and the PET volume was reconstructed using the attenuation and scatter sinograms in the reference position. The accuracy of the MC algorithm was first tested using a Hoffman phantom. Next, human volunteer studies were performed, and motion estimates were obtained using 2 high-temporal-resolution MRI-based motion-tracking techniques. RESULTS: After accounting for the misalignment between the 2 scanners, perfectly coregistered MRI and PET volumes were reproducibly obtained. The MRI output gates inserted into the PET list-mode allow the temporal correlation of the 2 datasets within 0.2 ms. The Hoffman phantom volume reconstructed by processing the PET data in the LOR space was similar to the one obtained by processing the data using the standard methods and applying the MC in the image space, demonstrating the quantitative accuracy of the procedure. In human volunteer studies, motion estimates were obtained from echo planar imaging and cloverleaf navigator sequences every 3 s and 20 ms, respectively. Motion-deblurred PET images, with excellent delineation of specific brain structures, were obtained using these 2 MRI-based estimates. CONCLUSION: An MRI-based MC algorithm was implemented for an integrated MR-PET scanner. High-temporal-resolution MRI-derived motion estimates (obtained while simultaneously acquiring anatomic or functional MRI data) can be used for PET MC. An MRI-based MC method has the potential to improve PET image quality, increasing its reliability, reproducibility, and quantitative accuracy, and to benefit many neurologic applications.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Algoritmos , Humanos , Interpretação de Imagem Assistida por Computador , Movimento (Física) , Imagens de Fantasmas
8.
J Nucl Med ; 51(9): 1431-8, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20810759

RESUMO

UNLABELLED: Several factors have to be considered for implementing an accurate attenuation-correction (AC) method in a combined MR-PET scanner. In this work, some of these challenges were investigated, and an AC method based entirely on the MRI data obtained with a single dedicated sequence was developed and used for neurologic studies performed with the MR-PET human brain scanner prototype. METHODS: The focus was on the problem of bone-air segmentation, selection of the linear attenuation coefficient for bone, and positioning of the radiofrequency coil. The impact of these factors on PET data quantification was studied in simulations and experimental measurements performed on the combined MR-PET scanner. A novel dual-echo ultrashort echo time (DUTE) MRI sequence was proposed for head imaging. Simultaneous MR-PET data were acquired, and the PET images reconstructed using the proposed DUTE MRI-based AC method were compared with the PET images that had been reconstructed using a CT-based AC method. RESULTS: Our data suggest that incorrectly accounting for the bone tissue attenuation can lead to large underestimations (>20%) of the radiotracer concentration in the cortex. Assigning a linear attenuation coefficient of 0.143 or 0.151 cm(-1) to bone tissue appears to give the best trade-off between bias and variability in the resulting images. Not identifying the internal air cavities introduces large overestimations (>20%) in adjacent structures. On the basis of these results, the segmented CT AC method was established as the silver standard for the segmented MRI-based AC method. For an integrated MR-PET scanner, in particular, ignoring the radiofrequency coil attenuation can cause large underestimations (i.e.,

Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Osso e Ossos/diagnóstico por imagem , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA