Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Ann Surg Oncol ; 30(13): 7976-7985, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37670120

RESUMO

BACKGROUND: Portal vein embolization (PVE) is used to induce remnant liver hypertrophy prior to major hepatectomy. The purpose of this study was to evaluate the predictive value of baseline computed tomography (CT) data for future remnant liver (FRL) hypertrophy after PVE. METHODS: In this retrospective study, all consecutive patients undergoing right-sided PVE with or without hepatic vein embolization between 2018 and 2021 were included. CT volumetry was performed before and after PVE to assess standardized FRL volume (sFRLV). Radiomic features were extracted from baseline CT after segmenting liver (without tumor), spleen and bone marrow. For selecting features that allow classification of response (hypertrophy ≥ 1.33), a stepwise dimension reduction was performed. Logistic regression models were fitted and selected features were tested for their predictive value. Decision curve analysis was performed on the test dataset. RESULTS: A total of 53 patients with liver tumor were included in this study. sFRLV increased significantly after PVE, with a mean hypertrophy of FRL of 1.5 ± 0.3-fold. sFRLV hypertrophy ≥ 1.33 was reached in 35 (66%) patients. Three independent radiomic features, i.e. liver-, spleen- and bone marrow-associated, differentiated well between responders and non-responders. A logistic regression model revealed the highest accuracy (area under the curve 0.875) for the prediction of response, with sensitivity of 1.0 and specificity of 0.5. Decision curve analysis revealed a positive net benefit when applying the model. CONCLUSIONS: This proof-of-concept study provides first evidence of a potential predictive value of baseline multi-organ radiomics CT data for FRL hypertrophy after PVE.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Veia Porta/patologia , Estudos Retrospectivos , Fígado/cirurgia , Hepatectomia/métodos , Neoplasias Hepáticas/cirurgia , Hipertrofia/patologia , Hipertrofia/cirurgia , Resultado do Tratamento
2.
Skeletal Radiol ; 52(10): 1987-1995, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37129611

RESUMO

OBJECTIVE: To evaluate the impact of a postoperative baseline (PB) MRI on diagnostic confidence and performance in detecting local recurrence (LR) of soft-tissue sarcoma (STS) of the limb. MATERIALS AND METHODS: A total of 72 patients (8 with LR, 64 without LR) with primary STS of the limb were included. Routine follow-up MRI (1.5 T) at 6 and approximately 36 months (meanLR: 39.7 months; meanno LR: 34.9 months) after multimodal therapy or at time of LR were assessed by three independent readers using a 5-point Likert scale. Furthermore, the following imaging parameters were evaluated: presence of a mass, signal characteristics at T2- and T1-weighted imaging, contrast enhancement (CE), and in some of the cases signal intensity on the apparent diffusion coefficient (ADC). U-test, McNemar test, and ROC-analysis were applied. Interobserver reliability was calculated using Fleiss kappa statistics. A p value of 0.05 was considered statistically significant. RESULTS: The presence of a PB MRI significantly improved diagnostic confidence in detecting LR of STS (p < 0.001) and slightly increased specificity (mean specificity without PE 74.1% and with presence of PB MRI 81.2%); however, not to a significant level. The presence of a mass showed highest diagnostic performance and highest interreader agreement (AUC [%]; κ: 73.1-83.6; 0.34) followed by T2-hyperintensity (50.8-66.7; 0.08), CE (52.4-62.5; 0.13), and T1-hypointensity (54.7-77.3; 0.23). ADC showed an AUC of 65.6-96.6% and a κ of 0.55. CONCLUSION: The presence of a PB MRI increases diagnostic confidence in detecting LR of STS of the limb.


Assuntos
Sarcoma , Neoplasias de Tecidos Moles , Humanos , Reprodutibilidade dos Testes , Meios de Contraste , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Sarcoma/diagnóstico por imagem , Sarcoma/cirurgia , Neoplasias de Tecidos Moles/diagnóstico por imagem , Neoplasias de Tecidos Moles/cirurgia , Sensibilidade e Especificidade , Recidiva Local de Neoplasia/diagnóstico por imagem
3.
Am J Med Genet A ; 185(10): 3122-3128, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34114335

RESUMO

Oncogenic RAS variants lead to constitutive overactivation and increased signal transduction into downstream pathways. They are found as somatic driver events in various types of human cancer. In a somatic mosaic status, the same RAS variants have been associated with a wide spectrum of focal or segmental tissue dysplasia and overgrowth including various types of congenital nevi, vascular malformations, and other changes (mosaic RASopathies). We present a 3-year-old male patient with segmental overgrowth of the subcutaneous fatty tissue of the right lower extremity with colocalized arteriovenous and capillary malformations and dysplastic draining veins in combination with talipes equinovarus of the right foot. In tissue biopsies of the affected extremity, we identified a mosaic KRAS variant, c.35G>A (p.Gly12Asp), while this variant was absent in the DNA extracted from a biopsy of the normal extremity. This report provides further evidence for the wide clinical and phenotypic variability associated with mosaic KRAS variants. The described pattern confirms that the combination of segmental overgrowth and vascular anomalies in the form of arteriovenous and capillary malformations is a possible manifestation of a mosaic RASopathy. The accurate genetic diagnosis is crucial for molecular-targeted therapy, which might be a future therapeutic target for mosaic RASopathies.


Assuntos
Predisposição Genética para Doença , Doenças Vasculares Periféricas/genética , Proteínas Proto-Oncogênicas p21(ras)/genética , Malformações Vasculares/genética , Pré-Escolar , Humanos , Masculino , Mutação/genética , Doenças Vasculares Periféricas/diagnóstico , Doenças Vasculares Periféricas/patologia , Fenótipo , Malformações Vasculares/diagnóstico , Malformações Vasculares/patologia
4.
Arch Orthop Trauma Surg ; 141(1): 165-171, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33130937

RESUMO

INTRODUCTION: Soft tissue reconstruction of the hand and distal upper extremity is challenging to preserve the function of the hand as good as possible. Therefore, a thin flap has been shown to be useful. In this retrospective study, we aimed to show the use of the free temporoparietal fascial flap in soft tissue reconstruction of the hand and distal upper extremity. METHODS: We analysed the outcome of free temporoparietal fascial flaps that were used between the years 2007and 2016 at our institution. Major and minor complications, defect location and donor site morbidity were the main fields of interest. RESULTS: 14 patients received a free temporoparietal fascial flap for soft tissue reconstruction of the distal upper extremity. Minor complications were noted in three patients and major complications in two patients. Total flap necrosis occurred in one patient. CONCLUSION: The free temporoparietal fascial flap is a useful tool in reconstructive surgery of the hand and the distal upper extremity with a low donor site morbidity and moderate rates of major and minor complications.


Assuntos
Mãos/cirurgia , Procedimentos de Cirurgia Plástica , Retalhos Cirúrgicos , Extremidade Superior/cirurgia , Humanos , Complicações Pós-Operatórias , Procedimentos de Cirurgia Plástica/efeitos adversos , Procedimentos de Cirurgia Plástica/métodos , Estudos Retrospectivos , Retalhos Cirúrgicos/efeitos adversos , Retalhos Cirúrgicos/cirurgia
5.
Diagn Interv Radiol ; 29(5): 719-732, 2023 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-37592882

RESUMO

PURPOSE: To characterize the artifacts of an 18-gauge coaxial nickel-titanium needle using a balanced steady-state free precession sequence in magnetic resonance imaging-guided interventions at 3.0 tesla. METHODS: The influence of flip angle (FA), bandwidth, matrix, slice thickness (ST), and read-out direction on needle artifact behavior was investigated for different intervention angles (IA). Artifact diameters were rated at predefined positions. Subgroup differences were assessed using Bonferroni-corrected non-parametric tests and correlations between continuous variables were expressed using the Bravais-Pearson coefficient. Interrater reliability was quantified using intraclass correlation coefficients (ICCs), and a contrast-enhanced target lesion to non-enhanced muscle tissue contrast ratio was quantified. RESULTS: The artifact diameters decreased with an increase in FA for all IAs (P < 0.001) and with an increase in ST for IAs of 45°-90° (all P < 0.05). Tip artifacts occurred at low IAs (0°-45°) and gradually increased in size with a decrease in IA (P = 0.022). The interrater reliability was high (ICC: 0.994-0.999). The contrast-enhanced target lesion to non-enhanced muscle tissue contrast ratio presented positive correlations with increasing FAs and matrices (P < 0.001; P = 0.003) and a negative correlation with increasing STs (P = 0.007). CONCLUSION: To minimize needle artifacts, it is recommended to use FAs of 40°-60°, a ST of >7 mm, and, if possible, an IA of 45°-60°. The visibility of the target lesion and the needle's artifact behavior must be weighed up against each other when choosing the ST, while higher FAs (40°-60°) and matrices (224 × 224/256 × 256) are associated with low artifacts and sufficient lesion visibility.


Assuntos
Artefatos , Agulhas , Humanos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética
6.
Diagn Interv Radiol ; 29(1): 128-137, 2023 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-36960560

RESUMO

PURPOSE: This study aimed to determine the optimal sequence parameters of a real-time T1-weighted (T1w) gradient echo (GRE) sequence for magnetic resonance (MR)-guided liver interventions. METHODS: We included 94 patients who underwent diagnostic liver MR imaging (MRI) and acquired additional real-time T1w GRE sequences with a closed 1.5-T MRI scanner 20 min after a liver-specific contrast agent was injected. In four measurement series, one of the following four sequence parameters was changed, and repeated scans with different values for this parameter were acquired: flip angle (FA) (10-90°), repetition time (TR) (5.47-8.58 ms), bandwidth (BW) (300-700 Hz/pixel), and matrix (96 × 96-256 × 256). Two readers rated the visualizations of the target and risk structures (7-point Likert scale) and the extent of artifacts (6-point Likert scale); they also quantified the lesion-liver contrast ratio, the lesion-liver contrast-to-noise ratio (CNR), and the liver signal-to-noise ratio (SNR). Substratification analyses were performed for differences in overall visual and quantitative assessments depending on the lesion size, type, and the presence of cirrhosis. RESULTS: For the utilized FAs and matrix sizes, significant differences were found in the visual assessments of the conspicuity of target lesions, risk structures, and the extent of artifacts as well as in the quantitative assessments of lesion-liver contrast ratios and liver SNRs (all P < 0.001). No differences were observed for modified TR and BW. Significantly increased conspicuity of the target and vascular structures was observed for both higher FAs and matrix sizes, while the ghosting artifacts increased and decreased, respectively. For primary liver tumors compared with metastatic lesions, and for cirrhotic livers compared with normal liver parenchyma, significantly decreased conspicuity of the target lesions (P = 0.005, P = 0.005), lesion-liver CNRs (P = 0.005, P = 0.032), and lesion-liver contrast ratios (P = 0.015, P = 0.032) were found. All results showed no significant correlation with lesion size. CONCLUSION: We recommend an FA of 30°-45° and a matrix size of 128 × 128-192 × 192 for MR-guided liver interventions with real-time T1w sequences to provide a balance between good visualizations of target and risk structures, high signal intensities, and low ghosting artifacts. The visualization of the target lesion may vary due to clinical conditions, such as lesion type or associated chronic liver disease.


Assuntos
Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Cirrose Hepática/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Meios de Contraste
7.
Diagnostics (Basel) ; 12(6)2022 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-35741240

RESUMO

Prediction of response to percutaneous sclerotherapy in patients with venous malformations (VM) is currently not possible with baseline clinical or imaging characteristics. This prospective single-center study aimed to predict treatment outcome of percutaneous sclerotherapy as measured by quality of life (QoL) by using radiomic analysis of diffusion-weighted (dw) magnetic resonance imaging (MRI) before and after first percutaneous sclerotherapy. In all patients (n = 16) pre-interventional (PRE-) and delta (DELTA-) radiomic features (RF) were extracted from dw-MRI before and after first percutaneous sclerotherapy with ethanol gel or polidocanol foam, while QoL was assessed using the Toronto Extremity Salvage Score (TESS) and the 36-Item Short Form Survey (SF-36) health questionnaire. For selecting features that allow differentiation of clinical response, a stepwise dimension reduction was performed. Logistic regression models were fitted and selected PRE-/DELTA-RF were tested for their predictive value. QoL improved significantly after percutaneous sclerotherapy. While no common baseline patient characteristics were able to predict response to percutaneous sclerotherapy, the radiomics signature of VMs (independent PRE/DELTA-RF) revealed high potential for the prediction of clinical response after percutaneous sclerotherapy. This proof-of-concept study provides first evidence on the potential predictive value of (delta) radiomic analysis from diffusion-weighted MRI for Quality-of-Life outcome after percutaneous sclerotherapy in patients with venous malformations.

8.
Sci Rep ; 11(1): 22963, 2021 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-34824361

RESUMO

Needle artifacts pose a major limitation for MRI-guided interventions, as they impact the visually perceived needle size and needle-to-target-distance. The objective of this agar liver phantom study was to establish an experimental basis to understand and reduce needle artifact formation during MRI-guided abdominal interventions. Using a vendor-specific prototype fluoroscopic T1-weighted gradient echo sequence with real-time multiplanar acquisition at 1.5 T, the influence of 6 parameters (flip angle, bandwidth, matrix, slice thickness, read-out direction, intervention angle relative to B0) on artifact formation of 4 different coaxial MR-compatible coaxial needles (Nitinol, 16G-22G) was investigated. As one parameter was modified, the others remained constant. For each individual parameter variation, 2 independent and blinded readers rated artifact diameters at 2 predefined positions (15 mm distance from the perceived needle tip and at 50% of the needle length). Differences between the experimental subgroups were assessed by Bonferroni-corrected non-parametric tests. Correlations between continuous variables were expressed by the Bravais-Pearson coefficient and interrater reliability was quantified using the intraclass classification coefficient. Needle artifact size increased gradually with increasing flip angles (p = 0.002) as well as increasing intervention angles (p < 0.001). Artifact diameters differed significantly between the chosen matrix sizes (p = 0.002) while modifying bandwidth, readout direction, and slice thickness showed no significant differences. Interrater reliability was high (intraclass correlation coefficient 0.776-0.910). To minimize needle artifacts in MRI-guided abdominal interventions while maintaining optimal visibility of the coaxial needle, we suggest medium-range flip angles and low intervention angles relative to B0.


Assuntos
Abdome/diagnóstico por imagem , Biópsia por Agulha , Imagem por Ressonância Magnética Intervencionista/métodos , Agulhas , Imagens de Fantasmas , Artefatos , Biópsia por Agulha/instrumentação , Biópsia por Agulha/métodos , Humanos , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA