Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Voice ; 36(1): 27-33, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32253079

RESUMO

INTRODUCTION: Measures of subglottal pressure (Ps), phonation threshold pressure (PTP), and laryngeal resistance (LR) can be used as indicators of vocal cord disorders. The gold standard non-invasive measurement uses labial interruption, which has been shown to have reliability inconsistencies. Mechanical interruption methods have demonstrated promise in measurement reliability. The goal of the present study is to compare retest reliability of labial and mechanical interruption methods. METHODS: 55 subjects aged 18-69 participated. Ten trials were performed for each method. For labial interruption, subjects produced five labial plosives at comfortable and quiet volumes. For mechanical interruption, subjects produced a sustained /α/ while a balloon valve interrupted phonation five times. Thirty subjects completed a second study visit identical to the first approximately two weeks (15 days ± 3.76) after the first visit. Ps, PTP, mean airflow rate, and LR were determined for each subject and retest reliability for each was analyzed. RESULTS: The percent difference in measurement results for test-retest of Ps were 12.88% ± 10.15 for mechanical interruption and 27.56% ± 17.14 for labial interruption (P = 0.0003). The percent difference for PTP measurements were 21.46% ± 16.01 for mechanical and 17.04% ± 14.62 (P = 0.3372) for labial. Intra-subject coefficients of variation of Ps were 0.086 ± 0.046 for mechanical and 0.161 ± 0.078 for labial (P < 0.0001). For PTP, the coefficients were 0.177 ± 0.083 for mechanical and 0.186 ± 0.091 for labial (P = 0.5402). Lastly, for LR (Ps divided by mean airflow rate) the percent differences were 14.33% ± 10.06 for mechanical and 53.87% ± 43.19 for labial (P < 0.0001) with intra-subject variability of 0.115 ± 0.050 for mechanical and 0.287 ± 0.222 for labial (P < 0.0001). CONCLUSIONS: Ps and LR measured using mechanical interruption showed more consistency for both retesting across separate study visits and intra-subject variability. PTP was similar in retesting and intra-subject variability. Continued work to improve mechanical interruption techniques is warranted as these methods offer higher reliability and consistency than the labial interruption methods.


Assuntos
Laringe , Fonação , Humanos , Reprodutibilidade dos Testes
2.
Genetics ; 177(1): 313-28, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17890365

RESUMO

The tissue polarity pathway is required for the establishment of epithelial polarity in a variety of vertebrate and invertebrate organs. Core tissue polarity proteins act in a dynamically regulated complex to direct the polarization of the Drosophila eye. We report the identification and characterization of bedraggled (bdg), a novel gene that regulates one output of the tissue polarity pathway--the establishment of the R3/R4 photoreceptor fates. bdg encodes a novel, putative transporter protein and interacts genetically with all of the core polarity genes to influence the specification of the R3 and R4 cell fates. Finally, bdg is required for both viability and the initial stages of imaginal disc development.


Assuntos
Polaridade Celular , Proteínas de Drosophila/metabolismo , Drosophila melanogaster/metabolismo , Olho/embriologia , Animais , Animais Geneticamente Modificados , Northern Blotting , Diferenciação Celular , Linhagem da Célula , Proteínas de Drosophila/genética , Drosophila melanogaster/citologia , Drosophila melanogaster/embriologia , Olho/citologia , Olho/metabolismo , Feminino , Regulação da Expressão Gênica no Desenvolvimento , Hibridização In Situ , Masculino , Atividade Motora , Fenótipo , Filogenia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA