Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Q J Nucl Med Mol Imaging ; 63(2): 207-215, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28478666

RESUMO

BACKGROUND: The aim of this study was to evaluate the role of metabolic and morphologic parameters derived from simultaneous hybrid PET/MRI in correlation to clinical criteria for an image-based characterization of musculoskeletal, esophagus and lymph node involvement in systemic sclerosis (SSc). METHODS: Between November 2013 and May 2015, simultaneous whole-body hybrid PET/MRI was performed in 13 prospectively recruited patients with SSc. A mean dose of 241.3 MBq 2-deoxy-2-[18F]fluoro-D-glucose (FDG) was injected. SUVmean and SUVmax values were measured in the spinal bone marrow, spleen, joints, muscles, fasciae, mediastinal lymph nodes and esophagus. MRI abnormalities were scored as 0 (absent), 1 (moderate) and 2 (marked). In addition, organ and skin involvement were graded with clinical sum score (CSS) and modified Rodnan skin score (mRSS), respectively. RESULTS: Results indicate positive correlations between mRSS and fascial FDG-uptake values (fascia summed SUVmax ρ=0.67; fascia summed SUVmean ρ=0.66) that performed better than the MRI sum score (ρ=0.50). Fascial FDG-uptake is also useful in the differentiation between diffuse and limited SSc. Additionally, FDG-PET detected patients with active mediastinal lymphadenopathy and MRI proved to be useful for the delineation of esophagus involvement. CONCLUSIONS: Fascial FDG-uptake has a strong correlation with mRSS and can discriminate between limited and diffuse SSc. These results and the detection of active lymphadenopathy and esophagus involvement can identify patients with advanced scleroderma. Combined PET/MRI therefore provides complementary information on the complex pathophysiology and may integrate several imaging procedures in one.


Assuntos
Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Escleroderma Sistêmico/metabolismo , Escleroderma Sistêmico/patologia , Adulto , Transporte Biológico , Biomarcadores/sangue , Feminino , Fluordesoxiglucose F18/metabolismo , Humanos , Masculino , Escleroderma Sistêmico/sangue , Escleroderma Sistêmico/diagnóstico por imagem
2.
Strahlenther Onkol ; 194(8): 719-726, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29564483

RESUMO

PURPOSE: The purpose of this study was to demonstrate the feasibility of voxel-wise multiparametric characterization of head and neck squamous cell carcinomas (HNSCC) using hybrid multiparametric magnetic resonance imaging and positron emission tomography with [18F]-fluorodesoxyglucose (FDG-PET/MRI) in a radiation treatment planning setup. METHODS: Ten patients with locally advanced HNSCC were examined with a combined FDG-PET/MRI in an irradiation planning setup. The multiparametric imaging protocol consisted of FDG-PET, T2-weighted transverse short tau inversion recovery sequence (STIR) and diffusion-weighted MRI (DWI). Primary tumours were manually segmented and quantitative imaging parameters were extracted. PET standardized uptake values (SUV) and DWI apparent diffusion coefficients (ADC) were correlated on a voxel-wise level. RESULTS: Images acquired in this specialised radiotherapy planning setup achieved good diagnostic quality. Median tumour volume was 4.9 [1.1-42.1] ml. Mean PET SUV and ADC of the primary tumours were 5 ± 2.5 and 1.2 ± 0.3 10-3 mm2/s, respectively. In voxel-wise correlation between ADC values and corresponding FDG SUV of the tumours, a significant negative correlation was observed (r = -0.31 ± 0.27, p < 0.05). CONCLUSION: Multiparametric voxel-wise characterization of HNSCC is feasible using combined PET/MRI in a radiation planning setup. This technique may provide novel insights into tumour biology with regard to radiation therapy in the future.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/radioterapia , Imagem de Difusão por Ressonância Magnética , Neoplasias Otorrinolaringológicas/diagnóstico por imagem , Neoplasias Otorrinolaringológicas/radioterapia , Tomografia por Emissão de Pósitrons , Planejamento da Radioterapia Assistida por Computador , Idoso , Carcinoma de Células Escamosas/patologia , Estudos de Coortes , Imagem de Difusão por Ressonância Magnética/instrumentação , Desenho de Equipamento , Estudos de Viabilidade , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias Otorrinolaringológicas/patologia , Projetos Piloto , Tomografia por Emissão de Pósitrons/instrumentação , Estudos Prospectivos , Radioterapia Adjuvante , Estatística como Assunto
3.
Eur Radiol ; 28(4): 1504-1511, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29134353

RESUMO

OBJECTIVES: To investigate the feasibility of simultaneous multislice-accelerated diffusion-weighted imaging (sms-DWI) of the pancreas with different acceleration factors and its influence on image quality, acquisition time and apparent diffusion coefficients (ADCs) in comparison to conventional sequences. METHODS: DWI of the pancreas was performed at 1.5T in ten healthy volunteers and 20 patients with sms-accelerated echo-planar DWI using two different sms-acceleration factors of 2 and 3 (sms2/3-DWI). These DWI sequences were compared to conventional DWI (c-DWI) in terms of image quality parameters (5-point Likert scale) and ADC measurements. RESULTS: c-DWI and sms2-DWI offered equivalently high overall image quality (4 [1; 5]) with scan time reduction to one-third (c-DWI: 173 s, sms2-DWI: 56 s). Sms3-DWI showed significantly poorer overall image quality (3 [1; 5]; p < 0.0001). ADC values were significantly lower in sms3-DWI compared to c-DWI in the pancreatic body and tail (body: c-DWI 1.4 x 10-3 mm2/s, sms3-DWI 1.0 x 10-3 mm2/s, p = 0.028; tail: c-DWI 1.3 x 10-3 mm2/s and sms3-DWI 1.0 x 10-3 mm2/s, p = 0.014). CONCLUSIONS: Accelerated multislice DWI of the pancreas offers high image quality with a substantial reduction of acquisition time. Lower ADC values in multislice DWI should be considered in diagnostic reading. KEY POINTS: • Simultaneous multislice-accelerated diffusion-weighted imaging (sms-DWI) promises scan time minimisation. • Sms-DWI of the pancreas offers diagnostic image quality in volunteers and patients. • Sms-DWI with an acceleration factor of 2 offers high image quality. • Higher acceleration factors in sms-DWI do not provide sufficient diagnostic image quality. • ADC values may be lower in sms-DWI.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Pâncreas/diagnóstico por imagem , Pancreatopatias/diagnóstico , Adulto , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
4.
Magn Reson Med ; 78(2): 632-644, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-27667730

RESUMO

PURPOSE: To enable fast and flexible high-resolution four-dimensional (4D) MRI of periodic thoracic/abdominal motion for motion visualization or motion-corrected imaging. METHODS: We proposed a Cartesian three-dimensional k-space sampling scheme that acquires a random combination of k-space lines in the ky/kz plane. A partial Fourier-like constraint compacts the sampling space to one half of k-space. The central k-space line is periodically acquired to allow an extraction of a self-navigated respiration signal used to populate a k-space of multiple breathing positions. The randomness of the acquisition (induced by periodic breathing pattern) yields a subsampled k-space that is reconstructed using compressed sensing. Local image evaluations (coefficient of variation and slope steepness through organs) reveal information about motion resolvability. Image quality is inspected by a blinded reading. Sequence and reconstruction method are made publicly available. RESULTS: The method is able to capture and reconstruct 4D images with high image quality and motion resolution within a short scan time of less than 2 min. These findings are supported by restricted-isometry-property analysis, local image evaluation, and blinded reading. CONCLUSION: The proposed method provides a clinical feasible setup to capture periodic respiratory motion with a fast acquisition protocol and can be extended by further surrogate signals to capture additional periodic motions. Retrospective parametrization allows for flexible tuning toward the targeted applications. Magn Reson Med 78:632-644, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Movimento/fisiologia , Tronco/diagnóstico por imagem , Algoritmos , Humanos , Respiração , Estudos Retrospectivos
5.
Eur J Nucl Med Mol Imaging ; 43(13): 2283-2289, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27565153

RESUMO

PURPOSE: To explore the feasibility of reducing administered tracer activities and to assess optimal activities for combined 18F-FDG-PET/MRI in pediatric oncology. METHODS: 30 18F-FDG-PET/MRI examinations were performed on 24 patients with known or suspected solid tumors (10 girls, 14 boys, age 12 ± 5.6 [1-18] years; PET scan duration: 4 min per bed position). Low-activity PET images were retrospectively simulated from the originally acquired data sets using randomized undersampling of list mode data. PET data of different simulated administered activities (0.25-2.5 MBq/kg body weight) were reconstructed with or without point spread function (PSF) modeling. Mean and maximum standardized uptake values (SUVmean and SUVmax) as well as SUV variation (SUVvar) were measured in physiologic organs and focal FDG-avid lesions. Detectability of organ structures and of focal 18F-FDG-avid lesions as well as the occurrence of false-positive PET lesions were assessed at different simulated tracer activities. RESULTS: Subjective image quality steadily declined with decreasing tracer activities. Compared to the originally acquired data sets, mean relative deviations of SUVmean and SUVmax were below 5 % at 18F-FDG activities of 1.5 MBq/kg or higher. Over 95 % of anatomic structures and all pathologic focal lesions were detectable at 1.5 MBq/kg 18F-FDG. Detectability of anatomic structures and focal lesions was significantly improved using PSF. No false-positive focal lesions were observed at tracer activities of 1 MBq/kg 18F-FDG or higher. Administration of 18F-FDG activities of 1.5 MBq/kg is, thus, feasible without obvious diagnostic shortcomings, which is equivalent to a dose reduction of more than 50 % compared to current recommendations. CONCLUSION: Significant reduction in administered 18F-FDG tracer activities is feasible in pediatric oncologic PET/MRI. Appropriate activities of 18F-FDG or other tracers for specific clinical questions have to be further established in selected patient populations.


Assuntos
Fluordesoxiglucose F18/administração & dosagem , Imageamento por Ressonância Magnética/métodos , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Exposição à Radiação/prevenção & controle , Proteção Radiológica/métodos , Adolescente , Criança , Pré-Escolar , Relação Dose-Resposta a Droga , Estudos de Viabilidade , Feminino , Humanos , Lactente , Masculino , Imagem Multimodal/métodos , Doses de Radiação , Exposição à Radiação/análise , Compostos Radiofarmacêuticos/administração & dosagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Imagem Corporal Total/métodos , Contagem Corporal Total/métodos
6.
J Magn Reson Imaging ; 43(4): 824-32, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26348708

RESUMO

PURPOSE: To introduce and evaluate a method for signal-to-noise ratio (SNR) improvement and T2 shine-through effect reduction in diffusion-weighted magnetic resonance imaging (DWI). MATERIALS AND METHODS: The proposed method uses quantitative information given by the voxel apparent diffusion coefficient (ADC) to derive voxelwise-computed DWI (vcDWI). Behavior of signal intensity variations was simulated and correlated with measurements using a dedicated phantom for DWI allowing for independent adjustment of T2 -relaxivity and diffusivity. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were measured and compared to the method of computed DWI (cDWI). Image signal was correlated with ADCs to appreciate the extent of T2 shine-through effects. Additionally, the proposed method was retrospectively applied to whole-body DWI data of 20 patients with metastatic malignancies. vcDWI was compared to cDWI and measured DWI with respect to image quality, lesion detectability, and lesion diffusivity assessment. RESULTS: Theoretically predicted signal intensity variations showed a high correlation with measured phantom data (r > 0.96). The proposed method yielded lower background signal intensity variation and higher contrast (+144%) and CNR (+358%) for diffusion-restricted phantom compartments than cDWI. Signal intensities of vcDWI showed an increased inverse correlation with phantom ADC values compared to cDWI (r = -0.86 vs. r = -0.73). Application to patient data showed higher image quality (P < 0.001) and lesion detectability (P = 0.011) using vcDWI compared to cDWI, and higher confidence for the correct identification of diffusion-restricted lesions compared to measured DWI (80/80 vs. 60/81; P = 0.013). CONCLUSION: vcDWI is a promising approach for the reduction of T2 shine-through effects and improvement of SNR and CNR in DWI. The clinical significance of these improvements, especially regarding lesion detection, needs to be evaluated in larger prospective clinical studies.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias/diagnóstico por imagem , Razão Sinal-Ruído , Adolescente , Adulto , Idoso , Algoritmos , Meios de Contraste/química , Imagem Ecoplanar , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Imagens de Fantasmas , Estudos Retrospectivos , Adulto Jovem
7.
J Magn Reson Imaging ; 44(4): 865-79, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-26919580

RESUMO

PURPOSE: To systematically evaluate image characteristics of simultaneous-multislice (SMS)-accelerated diffusion-weighted imaging (DWI) of the liver using different breathing schemes in comparison to standard sequences. MATERIALS AND METHODS: DWI of the liver was performed in 10 healthy volunteers and 12 patients at 1.5T using an SMS-accelerated echo planar imaging sequence performed with respiratory-triggering and free breathing (SMS-RT, SMS-FB). Standard DWI sequences served as reference (STD-RT, STD-FB). Reduction of scan time by SMS-acceleration was measured. Image characteristics of SMS-DWI and STD-DWI with both breathing schemes were analyzed quantitatively (apparent diffusion coefficient [ADC], signal-to-noise ratio [SNR]) and qualitatively (5-point Likert scale, 5 = excellent). Qualitative and quantitative parameters were compared using Friedman test and Dunn-Bonferroni post-hoc method with P-values < 0.05 considered statistically significant. RESULTS: SMS-DWI provided diagnostic image quality in volunteers and patients both with RT and FB with a reduction of scan time of 70% (0:56 vs. 3:20 min in FB). Overall image quality did not significantly differ between FB and RT acquisition in both STD and SMS sequences (median STD-RT 5.0, STD-FB 4.5, SMS-RT: 4.75; SMS-FB: 4.5; P = 0.294). SNR in the right hepatic lobe was comparable between the four tested sequences. ADC values were significantly lower in SMS-DWI compared to STD-DWI irrespective of the breathing scheme (1.2 ± 0.2 × 10(-3) mm(2) /s vs. 1.0 ± 0.2 × 10(-3) mm(2) /s; P < 0.001). CONCLUSION: SMS-acceleration provides considerable scan time reduction for hepatic DWI with equivalent image quality compared to the STD technique both using RT and FB. Discrepancies in ADC between STD-DWI and SMS-DWI need to be considered when transferring the SMS technique to clinical routine reading. J. MAGN. RESON. IMAGING 2016;44:865-879.


Assuntos
Artefatos , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Técnicas de Imagem de Sincronização Respiratória/métodos , Adulto , Algoritmos , Suspensão da Respiração , Feminino , Humanos , Fígado/anatomia & histologia , Masculino , Movimento (Física) , Reprodutibilidade dos Testes , Mecânica Respiratória , Sensibilidade e Especificidade
8.
MAGMA ; 29(5): 739-49, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27038935

RESUMO

OBJECTIVE: To evaluate simultaneous multislice (sms) accelerated diffusion-weighted imaging (DWI) of the liver in comparison to conventional sequences. MATERIALS AND METHODS: Ten volunteers underwent DWI of the liver at 1.5 T. Four different sms-accelerated sequences with monopolar and bipolar gradient preparation (MP, BP) and acceleration factors 2 and 3 (sms2-DWI, sms3-DWI) were compared to conventional DWI (c-DWI). Image quality criteria rated on a 5-point Likert scale (5 = excellent), image quality sum scores (maximum 120), and ADC were compared using Friedman test and Dunn-Bonferroni post hoc test. Bland-Altman plots were calculated for ADC comparison. p values <0.05 were considered significant. RESULTS: Sms2-DWI offered scan time minimization of 67 % without significant difference in image quality (sum score: sms2-DWI MP/BP: 97 ± 8/92 ± 9; c-DWI MP/BP: 99 ± 8/97 ± 8). Sms3-DWI offered slight additional scan time minimization with significantly inferior image quality (sum score: sms3-DWI MP/BP: 75 ± 14/69 ± 14; p < 0.001). MP preparation provided slightly higher image quality in sms-DWI without statistical significance. ADC in sms-DWI were significantly lower (sms2-DWI MP 1.01 × 10(-3) mm(2)/s; c-DWI MP 1.20 × 10(-3) mm(2)/s; p < 0.001). CONCLUSION: Sms2-DWI provides considerable scan time minimization without significant shortcomings in image quality. Sms3-DWI provides significantly inferior image quality without further scan time minimization. Potentially lower ADC in sms-DWI should be considered in clinical routine.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Adulto , Feminino , Voluntários Saudáveis , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Reprodutibilidade dos Testes , Fatores de Tempo
9.
Hell J Nucl Med ; 19(1): 15-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26929936

RESUMO

OBJECTIVE: Optimization of tracer dose regimes in positron emission tomography (PET) imaging is a trade-off between diagnostic image quality and radiation exposure. The challenge lies in defining minimal tracer doses that still result in sufficient diagnostic image quality. In order to find such minimal doses, it would be useful to simulate tracer dose reduction as this would enable to study the effects of tracer dose reduction on image quality in single patients without repeated injections of different amounts of tracer. The aim of our study was to introduce and validate a method for simulation of low-dose PET images enabling direct comparison of different tracer doses in single patients and under constant influencing factors. METHODS: (18)F-fluoride PET data were acquired on a combined PET/magnetic resonance imaging (MRI) scanner. PET data were stored together with the temporal information of the occurrence of single events (list-mode format). A predefined proportion of PET events were then randomly deleted resulting in undersampled PET data. These data sets were subsequently reconstructed resulting in simulated low-dose PET images (retrospective undersampling of list-mode data). This approach was validated in phantom experiments by visual inspection and by comparison of PET quality metrics contrast recovery coefficient (CRC), background-variability (BV) and signal-to-noise ratio (SNR) of measured and simulated PET images for different activity concentrations. In addition, reduced-dose PET images of a clinical (18)F-FDG PET dataset were simulated using the proposed approach. RESULTS: (18)F-PET image quality degraded with decreasing activity concentrations with comparable visual image characteristics in measured and in corresponding simulated PET images. This result was confirmed by quantification of image quality metrics. CRC, SNR and BV showed concordant behavior with decreasing activity concentrations for measured and for corresponding simulated PET images. Simulation of dose-reduced datasets based on clinical (18)F-FDG PET data demonstrated the clinical applicability of the proposed data. CONCLUSION: Simulation of PET tracer dose reduction is possible with retrospective undersampling of list-mode data. Resulting simulated low-dose images have equivalent characteristics with PET images actually measured at lower doses and can be used to derive optimal tracer dose regimes.


Assuntos
Algoritmos , Radioisótopos de Flúor/farmacocinética , Interpretação de Imagem Assistida por Computador/métodos , Modelos Biológicos , Tomografia por Emissão de Pósitrons/métodos , Proteção Radiológica/métodos , Simulação por Computador , Humanos , Aumento da Imagem/métodos , Modelos Estatísticos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Doses de Radiação , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tamanho da Amostra , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
10.
NMR Biomed ; 28(7): 914-22, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26014883

RESUMO

Multiparametric medical imaging data can be large and are often complex. Machine learning algorithms can assist in image interpretation when reliable training data exist. In most cases, however, knowledge about ground truth (e.g. histology) and thus training data is limited, which makes application of machine learning algorithms difficult. The purpose of this study was to design and implement a learning algorithm for classification of multidimensional medical imaging data that is robust and accurate even with limited prior knowledge and that allows for generalization and application to unseen data. Local prostate cancer was chosen as a model for application and validation. 16 patients underwent combined simultaneous [(11) C]-choline positron emission tomography (PET)/MRI. The following imaging parameters were acquired: T2 signal intensities, apparent diffusion coefficients, parameters Ktrans and Kep from dynamic contrast-enhanced MRI, and PET standardized uptake values (SUVs). A spatially constrained fuzzy c-means algorithm (sFCM) was applied to the single datasets and the resulting labeled data were used for training of a support vector machine (SVM) classifier. Accuracy and false positive and false negative rates of the proposed algorithm were determined in comparison with manual tumor delineation. For five of the 16 patients rates were also determined in comparison with the histopathological standard of reference. The combined sFCM/SVM algorithm proposed in this study revealed reliable classification results consistent with the histopathological reference standard and comparable to those of manual tumor delineation. sFCM/SVM generally performed better than unsupervised sFCM alone. We observed an improvement in accuracy with increasing number of imaging parameters used for clustering and SVM training. In particular, including PET SUVs as an additional parameter markedly improved classification results. A variety of applications are conceivable, especially for imaging of tissues without easily available histopathological correlation.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Aprendizado de Máquina , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Próstata/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
J Magn Reson Imaging ; 42(4): 1048-56, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25683203

RESUMO

BACKGROUND: To analyze the regional composition of bone marrow (BM) in correlation with metabolic activity and diffusivity using simultaneous positron emission tomography (PET)/MRI. METHODS: Retrospective analysis of 18F-FDG-PET/MR scans of 110 patients was performed. A three-dimensional gradient-echo sequence with Dixon-based fat-water separation was used for fat quantification. Dixon images, diffusion-weighted images (DWI) and 18F-FDG-PET were co-registered. Mean values of fat fraction (FF), standardized uptake value (SUV), and apparent diffusion coefficient (ADC) of BM were measured in different anatomical regions. Correlation of FF, SUV, and ADC and association of BM fat content and metabolic activity with anthropometric data was analyzed (Pearson). BM fat content and metabolic activity was compared in patients with and without chemotherapy (t-test). RESULTS: Regional differences in BM were found with highest fat content (93 ± 8%) and lowest ADC (0.22 ± 0.18 × 10(-3) mm(2) /s) in the peripheral skeleton and highest SUV in the spine (1.77 ± 0.6). There was a significant inverse correlation between FF and SUV (r = -0.73; P < 0.0001) and a significant inverse correlation between FF and ADC (r = -0.62; P < 0.0001). In patients with chemotherapy, a tendency to higher fat content and lower metabolic activity was observed in the proximal skeleton, although no statistical significance was reached. CONCLUSION: BM shows distinct regional variations in FF, SUV, and ADC. The inverse correlation of FF and SUV in BM suggests that BM adipose tissue does not have a comparable high metabolic activity as brown adipose tissue.


Assuntos
Tecido Adiposo/metabolismo , Medula Óssea/metabolismo , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Neoplasias/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Tecido Adiposo/patologia , Adiposidade , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Antropometria/métodos , Peso Corporal , Medula Óssea/patologia , Criança , Pré-Escolar , Meios de Contraste/farmacocinética , Fluordesoxiglucose F18/farmacocinética , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Neoplasias/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
12.
Radiology ; 273(1): 220-31, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24877983

RESUMO

PURPOSE: To compare positron emission tomography (PET)/magnetic resonance (MR) imaging and PET/computed tomography (CT) for lesion detection and interpretation, quantification of fluorine 18 ((18)F) fluorodeoxyglucose (FDG) uptake, and accuracy of MR-based PET attenuation correction in pediatric patients with solid tumors. Materials and Methods This prospective study had local ethics committee and German Federal Institute for Drugs and Medical Devices approval. Written informed consent was obtained from all patients and legal guardians. Twenty whole-body (18)F-FDG PET/CT and (18)F-FDG PET/MR examinations were performed in 18 pediatric patients (median age, 14 years; range, 11-17 years). (18)F-FDG PET/CT and (18)F-FDG PET/MR data were acquired sequentially on the same day for all patients. PET standardized uptake values (SUVs) were quantified with volume of interest measurements in lesions and healthy tissues. MR-based PET attenuation correction was compared with CT-derived attenuation maps (µ-maps). Lesion detection was assessed with separate reading of PET/CT and PET/MR data. Estimates of radiation dose were derived from the applied doses of (18)F-FDG and CT protocol parameters. Descriptive statistical analyses were performed to report correlation coefficients and relative deviations for comparison of SUVs, rates of lesion detection, and percentage reductions in radiation dose. RESULTS: PET SUVs showed strong correlations between PET of PET/CT (PETCT) and PET of PET/MR (PETMR) (r > 0.85 for most tissues). Apart from drawbacks of MR-based PET attenuation correction in osseous structures and lungs, similar SUVs were found on PET images corrected with CT-based µ-maps (13.1% deviation of SUVs for bone marrow and <5% deviation for other tissues). Lesion detection rate with PET/MR imaging was equivalent to that with PET/CT (61 areas of focal uptake on PETMR images vs 62 areas on PETCT images). Advantages of PET/MR were observed especially in soft-tissue regions. Furthermore, PET/MR offered significant dose reduction (73%) compared with PET/CT. CONCLUSION: Pediatric oncologic PET/MR is technically feasible, showing satisfactory performance for PET quantification with SUVs similar to those of PET/CT. Compared with PET/CT, PET/MR demonstrates equivalent lesion detection rates while offering markedly reduced radiation exposure. Thus, PET/MR is a promising modality for the clinical work-up of pediatric malignancies. Online supplemental material is available for this article.


Assuntos
Imageamento por Ressonância Magnética , Imagem Multimodal , Neoplasias/diagnóstico , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Imagem Corporal Total , Adolescente , Criança , Meios de Contraste , Feminino , Humanos , Masculino , Neoplasias/diagnóstico por imagem , Estudos Prospectivos , Doses de Radiação
13.
Magn Reson Med ; 72(2): 459-63, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24123316

RESUMO

PURPOSE: To design a phantom for diffusion-weighted imaging (DWI) with defined apparent diffusion coefficients (ADC) and T2 relaxation times. METHODS: Varying concentrations of polyethylene glycol (PEG) were used for the adjustment of diffusivity. T2 relaxation times were tuned by adding of the MR contrast agent gadobutrol. Relaxation times and apparent diffusion coefficients were quantified using a multiecho spin echo sequence and an echo planar imaging (EPI) DWI sequence, respectively, on a 3T clinical scanner. RESULTS: Increasing concentrations of PEG led to a marked impairment of diffusivity accompanied by only moderate changes of T2 relaxation times. Adding gadobutrol to the PEG solutions allowed for adjustment of transverse relaxation times to predefined values. Thus, a broad range of defined ADC values and T2 relaxation times could be accurately achieved in the final phantom. CONCLUSION: The proposed phantom allows for standardized in vitro studies of DWI methods and protocols. The obtained MR image contrasts are similar to a variety of biological tissues, which can contribute to optimization of imaging techniques with respect to specific clinical questions. Due to the simplicity of design and the accessibility of the contained compounds, this phantom may also serve as a tool for standardization and calibration.


Assuntos
Biomimética/instrumentação , Imagem de Difusão por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Magn Reson Med ; 71(1): 294-301, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23400875

RESUMO

PURPOSE: To improve the visualization of fibrous tissues as tendons, ligaments and fibrocartilage structures as menisci by positive contrast using a new 3D Double Echo Steady State (DESS) sequence. METHODS: The proposed 3D DESS sequence works with separate acquisition of a first echo with an echo time (TE1 ) of 1.2 ms followed by a more heavily T2 -weighted second echo recorded at time TE2 . Subtraction of images from both echoes leads to positive signal from fibrous tissues, whereas in other tissues as musculature and fat the subtraction signal nearly vanishes due to almost similar signal strength in both echoes. Systematic measurements in healthy volunteers with different sets of pulse repetition time (TR), TE1 , readout bandwidth and flip angle were performed to determine optimal sequence parameters. RESULTS: The presented 3D sequence with Cartesian readout requires relatively short measuring time, provides reasonable signal-to-noise ratio and can be easily implemented in protocols for clinical musculoskeletal MR imaging. Degenerative changes or tears of tendons, ligaments and fibrocartilage are known to cause increased water content and therefore prolongation of transverse relaxation times, which leads to reduced signal intensities in the "subtraction images." CONCLUSION: Positive contrast of fibrous tissue as demonstrated by the proposed sub-DESS approach provides improved conspicuity and allows for three-dimensional reconstruction especially of structures with curved geometry.


Assuntos
Articulação do Joelho/anatomia & histologia , Ligamentos/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Meniscos Tibiais/anatomia & histologia , Técnica de Subtração , Tendões/anatomia & histologia , Algoritmos , Meios de Contraste , Voluntários Saudáveis , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
J Magn Reson Imaging ; 40(5): 1121-8, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24923481

RESUMO

PURPOSE: To characterize peritoneal carcinomatosis (PC) of different histologically proven primary tumors based on diffusion-weighted imaging (DWI) and (18) F-FDG positron emission tomography (PET). MATERIALS AND METHODS: Forty-one patients underwent simultaneous MR/PET after clinically indicated (18) F-FDG-PET/CT. For all patients, histology of the primary tumor was obtained. MR protocol comprised anatomical imaging and axial DWI. Apparent diffusion coefficient (ADC) maps and FDG-PET were co-registered for evaluation of ADC and standard uptake value (SUV) of peritoneal lesions. Both lesion- and patient-based analysis was performed. Up to four peritoneal lesions were evaluated per patient. Mean and maximum standard uptake value (SUVmean , SUVmax ), mean and minimum ADC (ADCmean , ADCmin ) of each lesion were assessed. Spearman rank correlation (rs ) of ADC and SUV were calculated. SUV and ADC of ovarian and colorectal cancer lesions were compared using Wilcoxon test. RESULTS: Measurable lesions (n = 52) were found in 20 of 41 PC patients. Moderate, but significant correlation existed between ADC and SUV in the lesion-based as well as the patient-based analysis (lesion-based: SUVmean versus ADCmean rs = -0.58; SUVmax versus ADCmin rs = -0.56, all P < 0.0001; patient-based: SUVmean versus ADCmean rs = -0.64, P = 0.002; SUVmax versus ADCmin rs = -0.60, P = 0.005). ADC and SUV differed significantly between ovarian and colorectal cancer lesions (ADCmin : P < 0.0001; ADCmean : P < 0.0001; SUVmax : P = 0.002; SUVmean : P = 0.005). Overall, mucinous tumor entities showed a tendency to higher ADC and lower SUV. CONCLUSION: PC lesions showed significant differences in glucose uptake and diffusion characteristics depending on primary tumor histology. These differences should be considered when interpreting FDG-PET and DWI in PC patients.


Assuntos
Carcinoma/diagnóstico , Neoplasias Colorretais/diagnóstico , Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Neoplasias Ovarianas/diagnóstico , Neoplasias Peritoneais/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
16.
Radiology ; 268(1): 190-9, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23657890

RESUMO

PURPOSE: To compare anatomic alignment between morphologic and positron emission tomography (PET) images acquired in the abdomen and pelvis by using simultaneous magnetic resonance (MR)/PET, PET/computed tomography (CT), and retrospective MR/PET fusion and to compare alignment between MR and PET in simultaneous and sequential thoracic MR/PET by using different breathing, registration, and gating protocols. MATERIALS AND METHODS: Informed consent and institutional review board approval were obtained. The misalignment in 28 abdominal patient datasets was analyzed in simultaneous MR/PET, PET/CT, and retrospective MR/PET fusion. In seven thoracic MR/PET datasets, the effect of different breathing protocols, simultaneous, sequential, and MR-gated data acquisition was evaluated, and the effect of rigid registration versus nonregistered images was evaluated. Analysis of variance and subsequent Tukey test were used for statistical analysis. RESULTS: The misalignment in all abdominal organs was reduced in simultaneous MR/PET compared with retrospectively fused MR and PET images (means, 5.8 mm vs 11.9 mm; P < .001), and in the urinary bladder compared with PET/CT (means, 5.9 mm vs 11.0 mm; P < .007). Thoracic MR/PET with inspiratory breath-hold MR showed the largest misalignment (mean, 24.5 mm; P < .001). None of the other thoracic protocols that were composed of different acquisition, registration, or gating procedures differed significantly from one another. CONCLUSION: The alignment of hybrid datasets acquired in simultaneous whole-body MR/PET was more accurate than retrospective fusion in all investigated abdominal organs, and more accurate than PET/CT in the urinary bladder; the alignment of thoracic MR/PET with expiratory breath hold or free-breathing MR was more exact than with inspiratory MR. However in this preliminary work the clinical importance of these degrees of misalignment was not assessed.


Assuntos
Abdome , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X , Adulto , Idoso , Análise de Variância , Artefatos , Feminino , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/normas , Tomografia por Emissão de Pósitrons/normas , Controle de Qualidade , Reprodutibilidade dos Testes
17.
Radiology ; 264(2): 551-8, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22653189

RESUMO

PURPOSE: To compare the performance of magnetic resonance (MR)/positron emission tomography (PET) imaging in the staging of lung cancer with that of PET/computed tomography (CT) as the reference standard and to compare the quantification accuracy of a new whole-body MR/PET system with corresponding PET/CT data sets. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. Ten patients in whom bronchial carcinoma was proven or clinically suspected underwent clinically indicated fluorine 18 fluorodeoxyglucose (FDG) PET/CT and, immediately thereafter, whole-body MR/PET imaging with a new hybrid whole-body system (3.0-T MR imager with integrated PET system). Attenuation correction of MR/PET images was segmentation based with fat-water separation. Tumor-to-liver ratios were calculated and compared between PET/CT and MR/PET imaging. Tumor staging on the basis of the PET/CT and MR/PET studies was performed by two readers. Spearman rank correlation was used for comparison of data. RESULTS: MR/PET imaging provided diagnostic image quality in all patients, with good tumor delineation. Most lesions (nine of 10) showed pronounced FDG uptake. One lesion was morphologically suspicious for malignancy at CT and MR imaging but showed no FDG uptake. MR/PET imaging had higher mean tumor-to-liver ratios than did PET/CT (4.4 ± 2.0 [standard deviation] for PET/CT vs 8.0 ± 3.9 for MR/PET imaging). Significant correlation regarding the tumor-to-liver ratio was found between both imaging units (ρ = 0.93; P < .001). Identical TNM scores based on MR/PET and PET/CT data were found in seven of 10 patients. Differences in T and/or N staging occurred mainly owing to modality-inherent differences in lesion size measurement. CONCLUSION: MR/PET imaging of the lung is feasible and provides diagnostic image quality in the assessment of pulmonary masses. Similar lesion characterization and tumor stage were found in comparing PET/CT and MR/PET images in most patients.


Assuntos
Neoplasias Pulmonares/diagnóstico , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X , Idoso , Biópsia , Meios de Contraste , Feminino , Fluordesoxiglucose F18 , Humanos , Interpretação de Imagem Assistida por Computador , Iohexol/análogos & derivados , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Projetos Piloto , Compostos Radiofarmacêuticos , Imagem Corporal Total
18.
J Magn Reson Imaging ; 36(4): 951-60, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22645058

RESUMO

PURPOSE: To investigate the inhomogeneity of radiofrequency fields at higher field strengths that can interfere with established volumetric methods, in particular for the determination of visceral (VAT) and subcutaneous adipose tissue (SCAT). A versatile, interactive sparse sampling (VISS) method is proposed to determine VAT, SCAT, and also total body volume (TBV). MATERIALS AND METHODS: VISS is based on a separation of major components by contour lines, followed by a sparse sampling algorithm, and eventually a quick manual correction. T1-weighted whole body scans of 24 subjects were evaluated (12 at 1.5T, 12 at 3.0T). RESULTS: (a) Coefficients of variance (CV) and intra class correlation coefficients (ICC) determined within 3 raters (24 subjects) showed high consistency for SCAT (CV 2.2%, ICC 0.993) and VAT (CV 4.9%, ICC 0.987), (b) comparison with an established volumetric method revealed good agreement (Bland-Altman, VAT -0.68L to 1.07L, SCAT -2.18L to 8.39L), and (c) comparison of weights calculated from TBV with values measured on a scale resulted in an even better accuracy for VISS (Bland-Altman -1.98 kg to 4.09 kg) than for the reference method (-5.60 kg to 1.60 kg). CONCLUSION: VISS is reproducible in particular within the same rater, accurate as compared with established methods, and robust against low contrast and inhomogeneity artifacts.


Assuntos
Artefatos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Gordura Intra-Abdominal/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Imagem Corporal Total/métodos , Adulto , Algoritmos , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Tamanho da Amostra , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
19.
AJR Am J Roentgenol ; 199(2): 272-7, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22826387

RESUMO

OBJECTIVE: This article provides a short overview of hybrid imaging and the potential advantages of combined MR/PET. We will address some of the challenges that had to be met before MR/PET could become clinically available as well as further scientific work that has to be done to increase the potential benefit of this emerging hybrid modality. CONCLUSION: Hybrid imaging, the combination of two imaging modalities into one, promises the compensation of specific deficits of the modalities involved. PET/CT has gained wide acceptance for oncologic imaging in recent years; however, MRI has certain advantages that could make combined MR/PET more tempting in various clinical applications. The development of new clinical whole-body MR/PET systems offers new insights in metabolic and functional processes in oncology as well as cardiovascular and neurologic diseases.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Imagem Corporal Total , Meios de Contraste , Humanos , Imagem Multimodal , Neoplasias/patologia , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA