Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Sci Food Agric ; 93(9): 2308-14, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23371833

RESUMO

BACKGROUND: The quality of teas is currently graded using trained tea tasters, whose evaluation can sometimes be subjective. In this study the simple fluorescence-based technique of total luminescence spectroscopy (TLS) in conjunction with data classification using principal component analysis (PCA) was applied to discriminate between teas from 11 different Sri Lankan plantations. Solvent extraction of the tea samples was followed by TLS to record excitation-emission matrices in the excitation range 250-590 nm and emission range 300-700 nm. RESULTS: The application of PCA and linear discriminant analysis (LDA) allowed the successful classification of all 11 teas using only the first two principal components. LDA demonstrated how the technique was able to discriminate between all teas correctly with 100% classification. CONCLUSION: Further development of this work could lead to a simple device that could be used by tea manufacturers instead of or alongside trained tea tasters to grade teas.


Assuntos
Camellia sinensis/química , Inspeção de Alimentos/métodos , Qualidade dos Alimentos , Extratos Vegetais/química , Folhas de Planta/química , Chá/química , Camellia sinensis/crescimento & desenvolvimento , Análise Discriminante , Manipulação de Alimentos , Medições Luminescentes , Folhas de Planta/crescimento & desenvolvimento , Análise de Componente Principal , Solventes/química , Espectrometria de Fluorescência , Sri Lanka , Chá/classificação
2.
Micromachines (Basel) ; 12(3)2021 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-33803689

RESUMO

Microfluidic devices offer the potential to automate a wide variety of chemical and biological operations that are applicable for diagnostic and therapeutic operations with higher efficiency as well as higher repeatability and reproducibility. Polymer based microfluidic devices offer particular advantages including those of cost and biocompatibility. Here, we describe direct and replication approaches for manufacturing of polymer microfluidic devices. Replications approaches require fabrication of mould or master and we describe different methods of mould manufacture, including mechanical (micro-cutting; ultrasonic machining), energy-assisted methods (electrodischarge machining, micro-electrochemical machining, laser ablation, electron beam machining, focused ion beam (FIB) machining), traditional micro-electromechanical systems (MEMS) processes, as well as mould fabrication approaches for curved surfaces. The approaches for microfluidic device fabrications are described in terms of low volume production (casting, lamination, laser ablation, 3D printing) and high-volume production (hot embossing, injection moulding, and film or sheet operations).

3.
Biosens Bioelectron ; 129: 147-154, 2019 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-30690179

RESUMO

Deep Vein Thrombosis and pulmonary embolism (DVT/PE) is one of the most common causes of unexpected death for hospital in-patients. D-dimer is used as a biomarker within blood for the diagnosis of DVT/PE. We report a low-cost microfluidic device with a conveniently biofunctionalised interdigitated electrode (IDE) array and a portable impedimetric reader as a point-of-care (POC) device for the detection of D-dimer to aid diagnosis of DVT/PE. The IDE array elements, fabricated on a polyethylenenaphtalate (PEN) substrate, are biofunctionalised in situ after assembly of the microfluidic device by electropolymerisation of a copolymer of polypyrrole to which is immobilised a histidine tag anti-D-Dimer antibody. The most consistent copolymer films were produced using chronopotentiometry with an applied current of 5µA for a period of 50 s using a two-electrode system. The quality of the biofunctionalisation was monitored using optical microscopy, chronopotentiometry curves and impedimetric analysis. Measurement of clinical plasma sample with a D-dimer at concentration of 437 ng/mL with 15 biofunctionalised IDE array electrodes gave a ratiometric percentage of sample reading against the blank with an average value of 124 ±â€¯15 at 95% confidence. We have demonstrated the concept of a low cost disposable microfluidic device with a receptor functionalised on the IDE array for impedimetric detection towards POC diagnostics. Changing the receptor on the IDE array would allow this approach to be used for the direct detection of a wide range of analytes in a low cost manner.


Assuntos
Anticorpos Imobilizados/química , Técnicas Biossensoriais/instrumentação , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Dispositivos Lab-On-A-Chip , Sistemas Automatizados de Assistência Junto ao Leito , Polietilenos/química , Polímeros/química , Pirróis/química , Biomarcadores/análise , Biomarcadores/sangue , Impedância Elétrica , Eletrodos , Desenho de Equipamento , Humanos , Limite de Detecção , Polimerização , Embolia Pulmonar/sangue , Trombose Venosa/sangue
5.
Talanta ; 129: 491-8, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25127624

RESUMO

A reusable low cost microfluidic cell culture array device (MCCAD) integrated with a six output concentration gradient generator (cGG) and 4×6 arrays of microchamber elements, addressed by a series of row and columnar pneumatically actuated normally closed (NC) microvalves was fabricated for cell-based screening of chemotherapeutic compounds. The poly(dimethylsiloxane) (PDMS) device consists of three layers: fluidic, control and membrane which are held by surface contact and made leak-proof by clamping pressure. The NC valves are actuated by a thick PDMS membrane that was created by a novel method based on the self-assembly of PDMS pre-polymer molecules over a denser calcium chloride solution. The membrane actuated the valves reliably and particulates such as alumina particles (3 µm) and MCF-7 cells (20-24 µm) (2×10(5) cells/mL) were flowed through the valves without causing blockage or leakage and consequently avoiding contamination of the different cell culture elements. The MCCAD was cast and assembled in a standard laboratory without specialist equipment and demonstrated for performing quantitative cell-based cytotoxicity assays of pyocyanine on human breast cancer (MCF-7) cells and assessed for toxic effect on human hepatocyte carcinoma (HepG2) cells as an indicator for liver injury. Then, the MCCAD was demonstrated for sequential drug combinatorial screening involving gradient generation of paclitaxel doses followed by treatment with aspirin doses on the viability of MCF-7 cells. The interaction between paclitaxel and aspirin was evaluated by using the Bliss independence predictive model and results showed reasonable agreement with the model. A robust, portable, easily fabricated and low cost device is therefore shown to conveniently carry out culturing of multiple cell lines for high throughput screening of anti-cancer compounds using minimal reagents.


Assuntos
Cloreto de Cálcio/química , Técnicas Analíticas Microfluídicas/métodos , Aspirina/química , Reatores Biológicos , Adesão Celular , Técnicas de Cultura de Células/instrumentação , Linhagem Celular Tumoral , Relação Dose-Resposta a Droga , Desenho de Fármacos , Avaliação Pré-Clínica de Medicamentos , Quimioterapia Combinada , Células Hep G2 , Humanos , Células MCF-7 , Membranas Artificiais , Técnicas Analíticas Microfluídicas/economia , Microfluídica , Paclitaxel/química , Polímeros
6.
Analyst ; 128(7): 966-73, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12894840

RESUMO

Total luminescence spectroscopy combined with pattern recognition has been used to discriminate between four different types of edible oils, extra virgin olive (EVO), non-virgin olive (NVO), sunflower (SF) and rapeseed (RS) oils. Simplified fuzzy adaptive resonance theory mapping (SFAM), traditional back propagation (BP) and radial basis function (RBF) neural networks provided 100% classification for 120 samples, SFAM was found to be the most efficient. The investigation was extended to the adulteration of percentage v/v SF or RS in EVO at levels from 5% to 90% creating a total of 480 samples. SFAM was found to be more accurate than RBF and BP for classification of adulterant level. All misclassifications for SFAM occurred at the 5% v/v level resulting in a total of 99.375% correctly classified oil samples. The percentage of adulteration may be described by either RBF network (2.435% RMSE) or a simple Euclidean distance relationship of the principal component analysis (PCA) scores (2.977% RMSE) for v/v RS in EVO adulteration.


Assuntos
Reconhecimento Automatizado de Padrão , Óleos de Plantas/classificação , Biologia Computacional/métodos , Lógica Fuzzy , Espectrometria de Fluorescência/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA