Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 87(8): 4347-55, 2015 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-25815795

RESUMO

The combination of hydrodynamic focusing with embedded capillaries in a microfluidic device is shown to enable both surface enhanced Raman scattering (SERS) and electrochemical characterization of analytes at nanomolar concentrations in flow. The approach utilizes a versatile polystyrene device that contains an encapsulated microelectrode and fluidic tubing, which is shown to enable straightforward hydrodynamic focusing onto the electrode surface to improve detection. A polydimethyslsiloxane (PDMS) microchannel positioned over both the embedded tubing and SERS active electrode (aligned ∼200 µm from each other) generates a sheath flow that confines the analyte molecules eluting from the embedded tubing over the SERS electrode, increasing the interaction between the Riboflavin (vitamin B2) and the SERS active electrode. The microfluidic device was characterized using finite element simulations, amperometry, and Raman experiments. This device shows a SERS and amperometric detection limit near 1 and 100 nM, respectively. This combination of SERS and amperometry in a single device provides an improved method to identify and quantify electroactive analytes over either technique independently.


Assuntos
Técnicas Eletroquímicas , Técnicas Analíticas Microfluídicas , Riboflavina/análise , Eletrodos , Hidrodinâmica , Poliestirenos/química , Riboflavina/metabolismo , Análise Espectral Raman , Propriedades de Superfície
2.
Analyst ; 139(22): 5686-94, 2014 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-25105251

RESUMO

In this paper, we describe the development of a planar, pillar array device that can be used to image either side of a tunable membrane, as well as sample and detect small molecules in a cell-free region of the microchip. The pores are created by sealing two parallel PDMS microchannels (a cell channel and a collector channel) over a gold pillar array (5 or 10 µm in height), with the device being characterized and optimized for small molecule cross-over while excluding a flowing cell line (here, red blood cells, RBCs). The device was characterized in terms of the flow rate dependence of analyte cross-over and cell exclusion as well as the ability to perform amperometric detection of catechol and nitric oxide (NO) as they cross-over into the collector channel. Using catechol as the test analyte, the limits of detection (LOD) of the cross-over for the 10 µm and 5 µm pillar array heights were shown to be 50 nM and 105 nM, respectively. Detection of NO was made possible with a glassy carbon detection electrode (housed in the collector channel) modified with Pt-black and Nafion, to enhance sensitivity and selectivity, respectively. Reproducible cross-over of NO as a function of concentration resulted in a linear correlation (r(2) = 0.995, 7.6-190 µM), with an LOD for NO of 230 nM on the glassy carbon/Pt-black/0.05% Nafion electrode. The applicability of the device was demonstrated by measuring the NO released from hypoxic RBCs, with the device allowing the released NO to cross-over into a cell free channel where it was detected in close to real-time. This type of device is an attractive alternative to the use of 3-dimensional devices with polycarbonate membranes, as either side of the membrane can be imaged and facile integration of electrochemical detection is possible.


Assuntos
Eletrodos , Microfluídica/instrumentação , Catecóis/análise , Eritrócitos/química , Análise de Injeção de Fluxo , Humanos , Limite de Detecção , Óxido Nítrico/análise
3.
Electrophoresis ; 34(14): 2092-100, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23670668

RESUMO

In this paper, we present two new methodologies of improving the performance of microchip-based electrochemical detection in microfluidic devices. The first part describes the fabrication and characterization of epoxy-embedded gold microelectrode arrays that are evenly spaced and easily modified. Electrodepositions using a gold plating solution can be performed on the electrodes to result in a 3D pillar array that, when used with microchip-based flow injection analysis, leads to an eightfold increase in signal (when compared to a single electrode), with the LOD for catechol being 4 nM. For detecting analytically challenging molecules such as nitric oxide (NO), platinization of electrodes is commonly used to increase the sensitivity. It is shown here that microchip devices containing either the pillar arrays or more traditional glassy carbon electrodes can be modified with platinum black (Pt-black) for NO detection. In the case of using glassy carbon electrodes for NO detection, integration of the resulting platinized electrode with microchip-based flow analysis resulted in a ten times signal increase relative to use of a bare glassy carbon electrode. In addition, it is demonstrated that these electrodes can be coated with Nafion to impart selectivity toward NO over interfering species such as nitrite. The LOD for NO when using the Pt-black /Nafion-coated glassy carbon electrode was 9 nM. These electrodes can also be embedded in a polystyrene substrate, with the applicability of these sensitive and selective electrodes being demonstrated by monitoring the adenosine triphosphate-mediated release of NO from endothelial cells immobilized in a microfluidic network without any adhesion factor.


Assuntos
Análise em Microsséries/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Óxido Nítrico/análise , Platina/química , Animais , Técnicas Biossensoriais/instrumentação , Catecóis/análise , Bovinos , Linhagem Celular , Células Endoteliais/metabolismo , Limite de Detecção , Microeletrodos , Óxido Nítrico/metabolismo
4.
Anal Bioanal Chem ; 405(10): 3013-20, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23340999

RESUMO

The use of microchip devices to study cellular systems is a rapidly growing research area. There are numerous advantages of using on-chip integrated electrodes to monitor various cellular processes. The purpose of this review is to give examples of advancements in microchip-based cellular analysis, specifically where electrochemistry is used for the detection scheme. These examples include on-chip detection of single-cell quantal exocytosis, electrochemical analysis of intracellular contents, the ability to integrate cell culture/immobilization with electrochemistry, and the use of integrated electrodes to ensure cell confluency in longer-term cell culture experiments. A perspective on future trends in this area is also given.


Assuntos
Células/química , Técnicas Eletroquímicas/métodos , Procedimentos Analíticos em Microchip/métodos , Animais , Técnicas Eletroquímicas/instrumentação , Humanos , Dispositivos Lab-On-A-Chip
5.
Electrophoresis ; 32(22): 3121-8, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22038707

RESUMO

This paper describes the use of epoxy-encapsulated electrodes to integrate microchip-based electrophoresis with electrochemical detection. Devices with various electrode combinations can easily be developed. This includes a palladium decoupler with a downstream working electrode material of either gold, mercury/gold, platinum, glassy carbon, or a carbon fiber bundle. Additional device components such as the platinum wires for the electrophoresis separation and the counter electrode for detection can also be integrated into the epoxy base. The effect of the decoupler configuration was studied in terms of the separation performance, detector noise, and the ability to analyze samples of a high ionic strength. The ability of both glassy carbon and carbon fiber bundle electrodes to analyze a complex mixture was demonstrated. It was also shown that a PDMS-based valving microchip can be used along with the epoxy-embedded electrodes to integrate microdialysis sampling with microchip electrophoresis and electrochemical detection, with the microdialysis tubing also being embedded in the epoxy substrate. This approach enables one to vary the detection electrode material as desired in a manner where the electrodes can be polished and modified as is done with electrochemical flow cells used in liquid chromatography.


Assuntos
Eletroforese em Microchip/instrumentação , Eletroforese em Microchip/métodos , Resinas Epóxi/química , Catecóis/análise , Catecóis/química , Dopamina/análise , Dopamina/química , Eletrodos , Epinefrina/análise , Epinefrina/química , Desenho de Equipamento , Microdiálise , Paládio/química
6.
Electrophoresis ; 32(8): 822-31, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21413031

RESUMO

A new method of fabricating electrodes for microchip devices that involves the use of Teflon molds and a commercially available epoxy to embed electrodes of various sizes and compositions is described. The resulting epoxy base can be polished to generate a fresh electrode and sealed against poly(dimethylsiloxane) (PDMS)-based fluidic structures. Microchip-based flow injection analysis was used to characterize the epoxy-embedded electrodes. It was shown that gold electrodes can be amalgamated with liquid mercury and the resulting mercury/gold electrode is used to selectively detect glutathione from lysed red blood cells. The ability to encapsulate multiple electrode materials of differing compositions enabled the integration of microchip electrophoresis with electrochemical detection. Finally, a unique feature of this approach is that the electrode connection is made from the bottom of the epoxy base. This enables the creation of three-dimensional gold pillar electrodes (65 µm in diameter and 27 µm in height) that can be integrated within a fluidic network. As compared with the use of a flat electrode of a similar diameter, the use of the pillar electrode led to improvements in both the sensitivity (72.1 pA/µM for the pillar versus 4.2 pA/µM for the flat electrode) and limit of detection (20 nM for the pillar versus 600 nM for the flat electrode), with catechol being the test analyte. These epoxy-embedded electrodes hold promise for the creation of inexpensive microfluidic devices that can be used to electrochemically detect biologically important analytes in a manner where the electrodes can be polished and a fresh electrode surface is generated as desired.


Assuntos
Técnicas Eletroquímicas/instrumentação , Eletrodos , Eletroforese em Microchip/instrumentação , Compostos de Epóxi/química , Catecóis/análise , Técnicas Eletroquímicas/métodos , Eletroforese em Microchip/métodos , Desenho de Equipamento/métodos , Sensibilidade e Especificidade
7.
Lab Chip ; 14(12): 2023-32, 2014 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-24763966

RESUMO

We report two 3D printed devices that can be used for electrochemical detection. In both cases, the electrode is housed in commercially available, polymer-based fittings so that the various electrode materials (platinum, platinum black, carbon, gold, silver) can be easily added to a threaded receiving port printed on the device; this enables a module-like approach to the experimental design, where the electrodes are removable and can be easily repolished for reuse after exposure to biological samples. The first printed device represents a microfluidic platform with a 500 × 500 µm channel and a threaded receiving port to allow integration of either polyetheretherketone (PEEK) nut-encased glassy carbon or platinum black (Pt-black) electrodes for dopamine and nitric oxide (NO) detection, respectively. The embedded 1 mm glassy carbon electrode had a limit of detection (LOD) of 500 nM for dopamine and a linear response (R(2) = 0.99) for concentrations between 25-500 µM. When the glassy carbon electrode was coated with 0.05% Nafion, significant exclusion of nitrite was observed when compared to signal obtained from equimolar injections of dopamine. When using flow injection analysis with a Pt/Pt-black electrode and standards derived from NO gas, a linear correlation (R(2) = 0.99) over a wide range of concentrations (7.6-190 µM) was obtained, with the LOD for NO being 1 µM. The second application showcases a 3D printed fluidic device that allows collection of the biologically relevant analyte adenosine triphosphate (ATP) while simultaneously measuring the release stimulus (reduced oxygen concentration). The hypoxic sample (4.8 ± 0.5 ppm oxygen) released 2.4 ± 0.4 times more ATP than the normoxic sample (8.4 ± 0.6 ppm oxygen). Importantly, the results reported here verify the reproducible and transferable nature of using 3D printing as a fabrication technique, as devices and electrodes were moved between labs multiple times during completion of the study.


Assuntos
Dopamina/análise , Técnicas Eletroquímicas , Técnicas Analíticas Microfluídicas , Óxido Nítrico/análise , Impressão Tridimensional , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Eletrodos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Oxigênio/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA