Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Am Heart J ; 160(5): 862-9, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21095273

RESUMO

BACKGROUND: The conventional surgical aortic bioprostheses used for treatment of aortic stenosis (AS) are inherently stenotic in nature. The more favorable mechanical profile of the Medtronic CoreValve bioprosthesis may translate into a better hemodynamic and neurohormonal response. PATIENTS AND METHODS: The early hemodynamic and neurohormonal responses of 56 patients who underwent successful transcatheter aortic valve implantation (TAVI) using the Medtronic CoreValve bioprosthesis for severe symptomatic AS were compared with those of 36 patients who underwent surgical aortic valve replacement (SAVR) using tissue valves in the same period. RESULTS: At baseline, patients in the TAVI and SAVR group had comparable indexed aortic valve area (0.33 ± 0.1 vs 0.34 ± 0.1 cm² , respectively; P = .69) and mean transvalvular gradient (51.1 ± 16.5 vs 53.1 ± 14.3 mm Hg, respectively; P = .56). At 30-day follow-up, mean transvalvular gradient was lower in the TAVI group than in the SAVR group (10.3 ± 4 vs 13.1 ± 6.2 mm Hg, respectively; P = .015), and the indexed aortic valve area was larger in the TAVI group (1.0 ± 0.14 vs 0.93 ± 0.13 cm²/m²; P = .017). There was a trend toward a higher incidence of moderate patient-prosthesis mismatch in the surgical group compared with the TAVI group (30.5% vs 17.8%, respectively; P = .11). The overall incidence of prosthetic regurgitation (any degree) was higher in the TAVI group than in the SAVR group (85.7% vs 16.7%, respectively; P < .00001). The left ventricular mass index decreased after TAVI (175.1 ± 61.8 vs 165.6 ± 57.2 g/m²; P = .0003) and remained unchanged after SAVR (165.1 ± 50.6 vs 161 ± 64.8 g/m²; P = .81). Similarly, NT-ProBNP decreased after TAVI (3,479 ± 2,716 vs 2,533 ± 1,849 pg/mL; P = .033) and remained unchanged after SAVR (1,836 ± 2,779 vs 1,689 ± 1,533 pg/mL; P = .78). There was a modest correlation between natriuretic peptides and left ventricular mass index in the whole cohort (r = 0.4, P = .013). CONCLUSION: In patients with severe AS, TAVI resulted in lower transvalvular gradients and higher valve areas than SAVR. Such hemodynamic performance after TAVI may have contributed to early initiation of a reverse cardiac remodeling process and a decrease in natriuretic peptides.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica/fisiologia , Peptídeos Natriuréticos/sangue , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA