Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Chem Pharm Bull (Tokyo) ; 72(3): 271-279, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38432909

RESUMO

Codeine is a common analgesic drug that is a pro-drug of morphine. It also has a high risk of abuse as a recreational drug because of its extensive distribution as an OTC drug. Therefore, sensitive and selective screening methods for codeine are crucial in forensic analytical chemistry. To date, a commercial analytical kit has not been developed for dedicated codeine determination, and there is a need for an analytical method to quantify codeine in the field. In the present work, potential modulation was combined with electrochemiluminescence (ECL) for sensitive determination of codeine. The potential modulated technique involved applying a signal to electrodes by superimposing an AC potential on the DC potential. When tris(2,2'-bipyridine)ruthenium(II) ([Ru(bpy)3]2+) was used as an ECL emitter, ECL activity was confirmed for codeine. A detailed investigation of the electrochemical reaction mechanism suggested a characteristic ECL reaction mechanism involving electrochemical oxidation of the opioid framework. Besides the usual ECL reaction derived from the amine framework, selective detection of codeine was possible under the measurement conditions, with clear luminescence observed in an acidic solution. The sensitivity of codeine detection by potential modulated-ECL was one order of magnitude higher than that obtained with the conventional potential sweep method. The proposed method was applied to codeine determination in actual prescription medications and OTC drug samples. Codeine was selectively determined from other compounds in medications and showed good linearity with a low detection limit (150 ng mL-1).


Assuntos
Analgésicos Opioides , Codeína , Aminas , Analgésicos Opioides/análise , Analgésicos Opioides/química , Codeína/análise , Codeína/química , Eletrodos , Medicamentos sem Prescrição , Luminescência
2.
Arch Toxicol ; 97(12): 3085-3094, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37755504

RESUMO

In the recreational drug market, synthetic cannabinoids with a new acetamide linker structure emerged, most likely to circumvent the law. As the knowledge of drug metabolites is vital for proving drug consumption, the phase I metabolism of the newly emerging cannabinoids, ADB-FUBIATA, AFUBIATA, CH-FUBIATA, and CH-PIATA, was investigated. Each drug (10 µmol/L) was incubated with human liver microsomes for 1 h, and the samples, after dilution, were analyzed by liquid chromatography-high-resolution mass spectrometry. All drugs were metabolized via hydroxylation and N-dealkylation, while AFUBIATA and CH-PIATA additionally underwent ketone formation. The metabolites AF7 (hydroxylated at the indole/adjacent methylene) of ADB-FUBIATA, A16 (hydroxylated at the adamantane) of AFUBIATA, CF15 (hydroxylated at the cyclohexane) of CH-FUBIATA, and CP9 (hydroxylated at the pentane) of CH-PIATA were the most abundant metabolites by considering the peak areas on the chromatograms, and are recommended for urinalysis. The structure-metabolism relationship was also discussed, which generally agreed well with previously reported metabolic pathways of other synthetic cannabinoids. However, the preferred hydroxylation site of ADB-FUBIATA, the indole/adjacent methylene, clearly differed from that of ADB-FUBICA, the 3,3-dimethylbutanamide moiety, despite their structures differing only by a methylene group, emphasizing that metabolic predictions of new drugs should not replace in vitro experimental analyses, albeit helpful.


Assuntos
Canabinoides , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Metabolômica , Cromatografia Líquida/métodos , Canabinoides/metabolismo , Microssomos Hepáticos/metabolismo , Indóis/metabolismo
3.
Anal Chem ; 91(8): 5403-5414, 2019 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-30920801

RESUMO

Drift tube ion mobility spectrometry with a novel atmospheric electron emission (AEE) source was developed for determination of gaseous and blister chemical warfare agents (CWAs) in negative mode. The AEE source was fabricated from an aluminum substrate electrode covered with 1 µm silver nanoparticle-dispersed silicone resin and a thin gold layer. This structure enabled stable tunneling electron emission upon the application of more than 11 V potential under atmospheric pressure. The reactant ion peak (RIP) was observed for the reduced mobility constant ( K0) of 2.18 and optimized at the charging voltage of 20 V. This RIP was assigned to O2- by using a mass spectrometer. Hydrogen cyanide was detected as a peak ( K0 = 2.47) that was discriminatively separated from the RIP (resolution = 1.4), with a limit of detection (LOD) of 0.057 mg/m3, and assigned to CN- and OCN-. Phosgene was detected as a peak ( K0 = 2.36; resolution = 1.2; and LOD = 0.6 mg/m3), which was assigned to Cl-. Lewisite 1 was detected as two peaks ( K0 = 1.68 and 1.34; LOD = 12 and 15 mg/m3). The K0 = 1.68 peak was ascribed to a mixture of adducts of molecules or the product of hydrolysis with oxygen or chloride. Cyanogen chloride, chlorine, and sulfur mustard were also well detected. The detection performance with the AEE source was compared with those under corona discharge and 63Ni ionizations. The advantage of the AEE source is the simple RIP pattern (only O2-), and the characteristic marker ions contribute to the discriminative CWAs detection.


Assuntos
Vesícula/diagnóstico , Substâncias para a Guerra Química/análise , Pressão Atmosférica , Gases/análise , Humanos , Espectrometria de Mobilidade Iônica , Espectrometria de Massas por Ionização por Electrospray
4.
Anal Biochem ; 580: 42-48, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-31173726

RESUMO

Lactosides having either an amino-triethylene glycol or an azido-triethylene glycol were designed and synthesized, and the two derivatives were immobilized onto silicon nitride (SiN) surfaces. When a click reaction was applied for the immobilization of the azido-sugar, a Ricinus communis lectin (RCA120) was detected with a higher response by reflectometric interference spectroscopy (RIfS). When an N-hydroxysuccinimide (NHS) method was applied for the sugar immobilization, the response was less than that of the click one. The response of bovine serum albumin (BSA) as the negative control was negligible, but the lactose-SiN chip prepared by the click method suppressed nonspecific binding more effectively than did the chip from the NHS method. Next, we examined an antibody-immobilized SiN chip prepared by the click reaction. The detection response was, however, lower than that of the lactose-SiN chip, meaning that the sugar-chip by the click reaction was superior to the antibody-chip. Finally, to detect Shiga toxins from Escherichia coli O157:H7, globotrisaccharide (Gb3) with an azido-triethylene glycol was synthesized and immobilized onto the SiN chip by the click reaction. The Gb3-SiN chips enabled us to detect the toxins at concentrations less than 100 ng/mL. RCA120, horse gram, gorse lectins and BSA showed no response to the Gb3-SiN chip, showing a high specificity for the toxin.


Assuntos
Técnicas Biossensoriais/métodos , Ricina/análise , Toxinas Shiga/análise , Glicosídeos/química , Ligantes , Compostos de Silício/química
5.
Arch Toxicol ; 91(8): 2799-2812, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28120037

RESUMO

Diphenylarsinic acid (DPAA) is an organic arsenic compound used for the synthesis of chemical weapons. We previously found that the residents of Kamisu city in Ibaraki Prefecture, Japan, were exposed to DPAA through contaminated well water in 2003. Although mounting evidence strongly suggests that their neurological symptoms were caused by DPAA, the dynamics of DPAA distribution and metabolism after ingestion by humans remain to be elucidated. To accurately predict the distribution of DPAA in the human body, we administrated DPAA (1.0 mg/kg/day) to cynomolgus monkeys (n = 28) for 28 days. The whole tissues from these monkeys were collected at 5, 29, 170, and 339 days after the last administration. The concentration of DPAA in these tissues was measured by liquid chromatography-mass spectrometry. We found that DPAA accumulated in the central nervous system tissues for a longer period than in other tissues. This finding would extend our knowledge on the distribution dynamics and metabolism of DPAA in primates, including humans. Furthermore, it may be useful for developing a treatment strategy for patients who are exposed to DPAA.


Assuntos
Arsenicais/farmacocinética , Sistema Nervoso Central/metabolismo , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Animais , Arsenicais/administração & dosagem , Feminino , Macaca fascicularis , Masculino , Modelos Animais , Fatores de Tempo , Distribuição Tecidual
7.
Anal Chem ; 87(11): 5707-15, 2015 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-25958918

RESUMO

A gas-cylinder-free plasma desorption/ionization system was developed to realize a mobile on-site analytical device for detection of chemical warfare agents (CWAs). In this system, the plasma source was directly connected to the inlet of a mass spectrometer. The plasma can be generated with ambient air, which is drawn into the discharge region by negative pressure in the mass spectrometer. High-power density pulsed plasma of 100 kW could be generated by using a microhollow cathode and a laboratory-built high-intensity pulsed power supply (pulse width: 10-20 µs; repetition frequency: 50 Hz). CWAs were desorbed and protonated in the enclosed space adjacent to the plasma source. Protonated sample molecules were introduced to the mass spectrometer by airflow through the discharge region. To evaluate the analytical performance of this device, helium and air plasma were directly irradiated to CWAs in the gas-cylinder-free plasma desorption/ionization system and the protonated molecules were analyzed by using an ion-trap mass spectrometer. A blister agent (nitrogen mustard 3) and nerve gases [cyclohexylsarin (GF), tabun (GA), and O-ethyl S-2-N,N-diisopropylaminoethyl methylphosphonothiolate (VX)] in solution in n-hexane were applied to the Teflon rod and used as test samples, after solvent evaporation. As a result, protonated molecules of CWAs were successfully observed as the characteristic ion peaks at m/z 204, 181, 163, and 268, respectively. In air plasma, the limits of detection were estimated to be 22, 20, 4.8, and 1.0 pmol, respectively, which were lower than those obtained with helium plasma. To achieve quantitative analysis, calibration curves were made by using CWA stimulant dipinacolyl methylphosphonate as an internal standard; straight correlation lines (R(2) = 0.9998) of the peak intensity ratios (target per internal standard) were obtained. Remarkably, GA and GF gave protonated dimer ions, and the ratios of the protonated dimer ions to the protonated monomers increased with the amount of GA and GF applied.


Assuntos
Substâncias para a Guerra Química/análise , Técnicas de Química Analítica/instrumentação , Técnicas de Química Analítica/métodos , Espectrometria de Massas , Substâncias para a Guerra Química/química , Limite de Detecção , Estrutura Molecular , Volatilização
8.
Anal Chem ; 87(2): 1314-22, 2015 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-25553788

RESUMO

A new method enabling sensitive real-time air monitoring of highly reactive chemical warfare agents, namely, mustard gas (HD) and Lewisite 1 (L1), by detecting ions of their in-line reaction products instead of intact agents, is proposed. The method is based on corona discharge-initiated atmospheric pressure chemical ionization coupled with ion trap tandem mass spectrometry (MS(n)) via counterflow ion introduction. Therefore, it allows for highly sensitive and specific real-time detection of a broad range of airborne compounds. In-line chemical reactions, ionization reactions, and ion fragmentations of these agents were investigated. Mustard gas is oxygenated in small quantity by reactive oxygen species generated in the corona discharge. With increasing air humidity, the MS(2) signal intensity of protonated molecules of mono-oxygenated HD decreases but exceeds that of dominantly existing intact HD. This result can be explained in view of proton affinity. Lewisite 1 is hydrolyzed and oxidized. As the humidity increases from zero, the signal of the final product, namely, didechlorinated, dihydroxylated, and mono-oxygenated L1, quickly increases and reaches a plateau, giving the highest MS(2) and MS(3) signals among those of L1 and its reaction products. The addition of minimal moisture gives the highest signal intensity, even under low humidity. The method was demonstrated to provide sufficient analytical performance to meet the requirements concerning hygienic management and counter-terrorism. It will be the first practical method, in view of sensitivity and specificity, for real-time air monitoring of HD and L1 without sample pretreatment.

9.
Anal Chem ; 86(9): 4316-26, 2014 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-24678766

RESUMO

A highly sensitive and specific real-time field-deployable detection technology, based on counterflow air introduction atmospheric pressure chemical ionization, has been developed for a wide range of chemical warfare agents (CWAs) comprising gaseous (two blood agents, three choking agents), volatile (six nerve gases and one precursor agent, five blister agents), and nonvolatile (three lachrymators, three vomiting agents) agents in air. The approach can afford effective chemical ionization, in both positive and negative ion modes, for ion trap multiple-stage mass spectrometry (MS(n)). The volatile and nonvolatile CWAs tested provided characteristic ions, which were fragmented into MS(3) product ions in positive and negative ion modes. Portions of the fragment ions were assigned by laboratory hybrid mass spectrometry (MS) composed of linear ion trap and high-resolution mass spectrometers. Gaseous agents were detected by MS or MS(2) in negative ion mode. The limits of detection for a 1 s measurement were typically at or below the microgram per cubic meter level except for chloropicrin (submilligram per cubic meter). Matrix effects by gasoline vapor resulted in minimal false-positive signals for all the CWAs and some signal suppression in the case of mustard gas. The moisture level did influence the measurement of the CWAs.


Assuntos
Poluentes Atmosféricos/análise , Substâncias para a Guerra Química/análise , Espectrometria de Massas em Tandem/métodos , Pressão Atmosférica , Limite de Detecção
10.
Beilstein J Org Chem ; 10: 1504-12, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25161707

RESUMO

Glycosyl-[60]fullerenes were first used as decontaminants against ricin, a lactose recognition proteotoxin in the Ricinus communis family. A fullerene glycoconjugate carrying two lactose units was synthesized by a [3 + 2] cycloaddition reaction between C60 and the azide group in 6-azidohexyl ß-lactoside per-O-acetate. A colloidal aqueous solution with brown color was prepared from deprotected bis(lactosyl)-C60 and was found stable for more than 6 months keeping its red color. Upon mixing with an aqueous solution of Ricinus communis agglutinin (RCA120), the colloidal solution soon caused precipitations, while becoming colorless and transparent. In contrast, a solution of concanavalin A (Con A) caused no apparent change, indicating that the precipitation was caused specifically by carbohydrate-protein interactions. This notable phenomenon was quantified by means of sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE), and the results were discussed in terms of detection and decontamination of the deadly biological toxin in the Ricinus communis family.

11.
Anal Chem ; 85(5): 2659-66, 2013 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-23339735

RESUMO

A new method for sensitively and selectively detecting chemical warfare agents (CWAs) in air was developed using counter-flow introduction atmospheric pressure chemical ionization mass spectrometry (MS). Four volatile and highly toxic CWAs were examined, including the nerve gases sarin and tabun, and the blister agents mustard gas (HD) and Lewisite 1 (L1). Soft ionization was performed using corona discharge to form reactant ions, and the ions were sent in the direction opposite to the airflow by an electric field to eliminate the interfering neutral molecules such as ozone and nitrogen oxide. This resulted in efficient ionization of the target CWAs, especially in the negative ionization mode. Quadrupole MS (QMS) and ion trap tandem MS (ITMS) instruments were developed and investigated, which were movable on the building floor. For sarin, tabun, and HD, the protonated molecular ions and their fragment ions were observed in the positive ion mode. For L1, the chloride adduct ions of L1 hydrolysis products were observed in negative ion mode. The limit of detection (LOD) values in real-time or for a 1 s measurement monitoring the characteristic ions were between 1 and 8 µg/m(3) in QMS instrument. Collision-induced fragmentation patterns for the CWAs were observed in an ITMS instrument, and optimized combinations of the parent and daughter ion pairs were selected to achieve real-time detection with LOD values of around 1 µg/m(3). This is a first demonstration of sensitive and specific real-time detection of both positively and negatively ionizable CWAs by MS instruments used for field monitoring.

12.
ACS Omega ; 8(15): 13754-13762, 2023 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-37091419

RESUMO

Glycolipid chips having a double layer of Au nanoparticles are proposed for detection of biological toxins. The sugar-modified chips constitute an under and an upper layer of Au nanoparticles of 20-80 nm diameter on glass plates, and Au nanoparticles of each layer are linked with 1,8-octanedithiol by a self-assembled monolayer (SAM) technique. A tris-sialo glycosphingolipid, ganglioside GT1b, having lipoic amide at the sphingosine part was immobilized on the Au outside surface of the upper layer, and botulinum toxin (type A heavy chain) was detected by localized surface plasmon resonance (LSPR). The GT1b-Cer-coated chip having a double layer of Au nanoparticles enhanced the toxin detection by LSPR more than those with single monolayers. The LSPR response changed according to the sizes of Au nanoparticles in each under and upper layer. The combination of 60 and 40 nm Au nanoparticles in the under and upper layer, respectively, gave the best result, which enabled the toxin detection at concentrations below 5 ng/mL with the portable LSPR device.

13.
J Anal Toxicol ; 47(5): 455-463, 2023 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-36857377

RESUMO

A new class of synthetic cannabinoids termed OXIZIDs has recently emerged on the recreational drug market. In order to continue the detection of new drugs in biological specimens, the identification of metabolites is essential. The aim of this study was to elucidate the metabolites of BZO-4en-POXIZID produced in human liver microsomes (HLMs) and human hepatocyte incubations and to compare the results with closely related analogs using the same experimental setup. Each drug was incubated for 1 h in HLM and BZO-4en-POXIZID was also incubated in human hepatocytes for up to 3 h. Subsequently, the incubates were analyzed by liquid chromatography-high-resolution mass spectrometry. BZO-4en-POXIZID metabolites were obtained in the incubation with HLMs and human hepatocytes, via the metabolic pathways of dihydrodiol formation, hydroxylation, reduction of the alkene bond and glucuronidation. The major metabolic pathway was found to be dihydrodiol formation at the pentenyl tail moiety. BZO-POXIZID, 5 F-BZO-POXIZID, BZO-HEXOXIZID and BZO-CHMOXIZID underwent similar metabolism to those reported in the literature, via the metabolic pathways of N-dealkylation, hydroxylation, ketone formation and oxidative defluorination (to alcohol or carboxylic acid). The results suggest that OXIZIDs are mainly metabolized at the N-alkyl moiety and the major metabolic pathways are hydroxylation when the N-alkyl moiety is a simple hydrocarbon, whereas functional-group-specific pathways (dihydrodiol formation and oxidative defluorination) are preferred when the moiety contains specific functional groups (alkene or fluoro), as has been observed for other synthetic cannabinoids. The major metabolites generated via these major metabolic pathways should serve as useful analytical targets for urine analysis. Furthermore, the higher abundance of glucuronidated metabolite suggests that enzymatic hydrolysis of glucuronides may be necessary for urine analysis to increase phase I metabolite concentration and improve detection.


Assuntos
Canabinoides , Naftalenos , Humanos , Espectrometria de Massas/métodos , Naftalenos/metabolismo , Canabinoides/análise , Alcenos/metabolismo , Microssomos Hepáticos/metabolismo
14.
ACS Omega ; 8(4): 4285-4293, 2023 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-36743070

RESUMO

The quantitative evaluation of the drug mixing condition was conducted for application in the forensic discrimination of drug powders using micro Fourier transform infrared (FT-IR) spectroscopy. Bromhexine hydrochloride (BHCl) and p-hydroxybenzoic acid (PHBA) were used as the simulated drug and additive, respectively. Equal masses of two chemicals were (1) simply mixed, (2) homogenized using agate mortar, or (3) dissolved in methanol and dried, and then (4) homogenized using agate mortar. The mixed powders dispersed on BaF2 plates were subjected to mapping analysis of micro FT-IR spectroscopy using synchrotron radiation (SR) or globar light in transmission mode with aperture sizes of 2.5 x 2.5 and 10 x 10µm2, and x-y scanning steps of 2.5 and 10 µm, respectively. The areas of the vibration bands specific to BHCl (C-N bending) and PHBA (C=O stretching) were converted to the molar contents (CBHCl, CPHBA), and the relative content ratio (RCR: CPHBA/[CBHCl + CPHBA]) was used as one mixing parameter. The resulting two-dimensional distribution map provided the relative spatial localizations of the two species, and frequency histograms with a horizontal axis of RCR were plotted to evaluate the RCR distribution. The percentage frequency of the extreme value in which RCR was 0 or 1 (%EV) was used as one mixing index. After excluding the extreme values, the coefficient of variation (CV) of the RCR distribution was used as another mixing index. The differentiation among four mixing modes could be evaluated from the standpoint of %EV and CV, and the discrimination capacity by SR instrument was superior to that by globe light instrument.

15.
J Forensic Sci ; 67(5): 1825-1835, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35852053

RESUMO

Automotive glasses are important forensic evidence often recovered from crime scenes. Black ceramic prints on automotive glasses contains various elements in high concentrations. A portable X-ray fluorescence spectrometer (pXRF) allows an instant and nondestructive analysis of various elements. In this study, the Bruker Tracer 5 g was used as the pXRF equipment. The NIST SRM612 glass standard was used to determine the limit of detection (LODs) of a pXRF and its optimal conditions. The acceleration voltages of 15, 30, and 50 kV were appropriate for measuring Si Kα (1.740 keV)-Ni Kα (7.473 keV), Cu Kα (8.042 keV)-Pb Lα (10.552 keV), and after Bi Kα (10.839 keV), respectively. The pXRF was used to compare 37 black ceramic prints on automotive glasses from the known source. The samples were divided into two groups: the Pb type and the Bi type. The samples were compared in pairs. The most appropriate and effective indicators for discriminating between the Pb and Bi type of black ceramic prints on automotive glasses were Zr Kα /Pb Lα and Cu Kα /Cr Kα for the Pb type, and Zr Kα /Bi Lα and Cu Kα /Crα for the Bi type, respectively. The samples were compared with other elements detected by pXRF to further discriminate them. 98.9% of all pairs were successfully discriminated. Results showed that black ceramic prints on automotive glasses are able to be discriminated by pXRF.

16.
Forensic Toxicol ; 40(2): 278-288, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36454404

RESUMO

PURPOSE: JWH-424, (8-bromo-1-naphthyl)(1-pentyl-1H-indol-3-yl)methanone, is a synthetic cannabinoid, which is a brominated analogue of JWH-018, one of the best-known synthetic cannabinoids. Despite the structural similarity to JWH-018, little is known about JWH-424 including its metabolism. The aim of the study was to compare human liver microsomes (HLM) and the fungus Cunninghamella elegans as the metabolism catalysts for JWH-424 to better understand the characteristic actions of the fungus in the synthetic cannabinoid metabolism. METHODS: JWH-424 was incubated with HLM for 1 h and Cunninghamella elegans for up to 72 h. The HLM incubation mixtures were diluted with methanol and fungal incubation mixtures were extracted with dichloromethane and reconstituted in methanol before analyses by liquid chromatography-high-resolution mass spectrometry (LC-HRMS). RESULTS: HLM incubation resulted in production of ten metabolites through dihydrodiol formation, hydroxylation, and/or ipso substitution of the bromine with a hydroxy group. Fungal incubation led to production of 23 metabolites through carboxylation, dihydrodiol formation, hydroxylation, ketone formation, glucosidation and/or sulfation. CONCLUSIONS: Generally, HLM models give good predictions of human metabolites and structural analogues are metabolised in a similar fashion. However, major hydroxy metabolites produced by HLM were those hydroxylated at naphthalene instead of pentyl moiety, the major site of hydroxylation for JWH-018. Fungal metabolites, on the other hand, had undergone hydroxylation mainly at pentyl moiety. The metabolic disagreement suggests the necessity to verify the human metabolites in authentic urine samples, while H9 and H10 (hydroxynaphthalene), H8 (ipso substitution), F22 (hydroxypentyl), and F17 (dihydroxypentyl) are recommended for monitoring of JWH-424 in urinalysis.


Assuntos
Canabinoides , Cunninghamella , Humanos , Microssomos Hepáticos , Metanol , Biotransformação , Espectrometria de Massas
17.
ACS Omega ; 7(43): 38789-38795, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36340080

RESUMO

Fiber examination is frequently performed in forensics, and gel permeation chromatography (GPC) is one candidate method for discriminating polyester fibers. Here, the effects of machine washing on weight-average molecular weight (M w), polydispersity index (PDI), and the percentage peak area of cyclic ethylene terephthalate trimer (PPAL) of commercial polyester shirts and manufactured poly(ethylene terephthalate) (PET) yarns were investigated using GPC. GPC was performed using a 1,1,1,3,3,3-hexafluoro-propan-2-ol polymer solubilizer, styrene-divinylbenzene copolymer GPC columns, a chloroform mobile phase, and a 254 nm absorbance monitor. The statistical change in the polyester fibers during machine washing was evaluated by comparing three GPC parameters of the same fiber samples before and after machine washing. Among the commercial polyester shirts examined, the GPC parameters changed significantly after machine washing with a considerable PPAL decrease. In contrast, the GPC parameters of manufactured PET yarns changed significantly with a moderate increase in M w. This work elucidates the change on GPC parameters of polyester fibers by machine washing.

18.
ACS Omega ; 6(48): 32597-32606, 2021 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-34901608

RESUMO

According to our previously proposed scheme, each of three kinds of glycosphingolipid (GSL) derivatives, that is, lactosyl ceramide [Lac-Cer (1)] and gangliosides [GM1-Cer (2) and GT1b-Cer (3)], was installed onto the glass surface modified with Au nanoparticles. In the present study, we tried to apply microwave irradiation to promote their installing reactions. Otherwise, this procedure takes a lot of time as long as a conventional self-assembled monolayer (SAM) technique is applied. Using an advanced microwave reactor capable of adjusting ambient temperatures within a desired range, various GSL glycochips were prepared from the derivatives (1)-(3) under different microwave irradiation conditions. The overall assembling process was programed with an IC controller to finish in 1 h, and the derived GSL glycochips were evaluated in the analysis of three kinds of biological toxins [a Ricinus agglutinin (RCA120), botulinum toxin (BTX), and cholera toxin (CTX)] using a localized surface plasmon resonance (LSPR) biosensor. In the LSPR analysis, most of the irradiated GSL chips showed an enhanced response to the targeting toxin when they were irradiated under optimal temperature conditions. Lac-Cer chips showed the highest response to RCA120 (an agglutinin with ß-D-Gal specificity) when the microwave irradiation was conducted at 30-35 °C. Compared to our former Lac-Cer glycochips with the conventional SAM condition, their response was enhanced by 3.6 times. Analogously, GT1b chips gained an approximately 4.1 times enhancement in their response to botulinum type C toxin (BTX/C) when the irradiation was conducted around at 45-60 °C. In the LSPR evaluation of the GM1-Cer glycochips using CTX, an optimal condition also appeared at around 30-35 °C. On the other hand, the microwave irradiation did not lead to a notable increase compared to the former GM1-Cer chips derived with the SAM technique. Judging from these experimental results, the microwave irradiation effectively promotes the installing process for all the three kinds of the GSL derivatives, while the optimal thermal condition becomes different from each other. Many bacterial and botanic proteinous toxins are composed of such carbohydrate binding domains or subunits that can discriminate both the key epitope structure and the dimension of glycoconjugates on the host cell surface. It is assumed that the optimal irradiation and thermal conditions are required to array these semi-synthetic GSL derivatives on the Au nanoparticles in a proper density and geometry for tight adhesion with each of the biological toxins.

20.
Anal Biochem ; 385(1): 94-100, 2009 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-18952040

RESUMO

An analytical method for determining paraoxonase activity against sarin, soman and VX was established. We used capillary electrophoresis to measure directly the hydrolysis products: alkyl methylphosphonates. After enzymatic reaction of human serum paraoxonase (PON1) with nerve gas, substrate was removed with dichloromethane, and alkyl methylphoshphonates were quantified by capillary electrophoresis of reversed osmotic flow using cationic detergent and sorbic acid. This method was applied to the characterization of human serum PON1 polymorphism for nerve gas hydrolytic activity in the coding region (Q192R). PON1-192 and PON1-55 genotypes were determined by their gel electrophoretic fragmentation pattern with restriction enzymes after polymerase chain reaction (PCR) of blood leukocyte genomic DNA. Frequencies of genotypes among 63 members of our institutes with PON1-192 and PON1-55 were 9.5% ((192)QQ), 30.1% ((192)QR) and 44.4% ((192)RR), and 82.5% ((55)LL), 17.5% ((55)LM) and 0% ((55)MM), respectively. (192)Q and (192)R enzymes were purified from the respective genotype human plasma, using blue agarose affinity chromatography and diethyl amino ethane (DEAE) anion exchange chromatography. V(max) and K(m) were measured using Lineweaver-Burk plots for hydrolytic activities against sarin, soman and VX at pH 7.4 and 25 degrees C. For sarin and soman, the V(max) for (192)Q PON1 were 3.5- and 1.5-fold higher than those for (192)R PON1; and k(cat)/K(m) for (192)Q PON1 were 1.3- and 2.8-fold higher than those for (192)R PON1. For VX, there was little difference in V(max) and k(cat)/K(m) between (192)Q and (192)R PON1, and VX hydrolyzing activity was significantly lower than those for sarin and soman. PON1 hydrolyzed sarin and soman more effectively than paraoxon.


Assuntos
Arildialquilfosfatase/genética , Arildialquilfosfatase/metabolismo , Fases de Leitura Aberta/genética , Compostos Organotiofosforados/metabolismo , Polimorfismo Genético , Sarina/metabolismo , Soman/metabolismo , Eletroforese Capilar , Genótipo , Humanos , Hidrólise , Estrutura Molecular , Compostos Organotiofosforados/química , Reação em Cadeia da Polimerase , Sarina/química , Soman/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA