Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 72(4): 658-68, 2000 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-10701248

RESUMO

The responses relative to an air background of carbon black/polymer composite vapor detectors have been determined as a function of the concentration of a homologous series of alcohols (n-CnH2n+1OH, 1 < or = n < or = 8), a homologous series of alkanes (n-CnH2n+2, 5 < or = n < or = 10 and n = 12, 14), and a set of diverse solvent vapors. In all cases, the steady-state relative differential resistance responses, delta R/Rb, of the carbon black/polymer composite vapor detectors were well-described by a linear relationship with respect to the analyte partial pressure, at least over the tested concentration range (P/P degree = 0.005-0.03, where P degree is the vapor pressure of the analyte). When two vapors in air were simultaneously presented to the detectors, the delta R/Rb response, relative to an air background, was the sum of the delta R/Rb values obtained when each analyte was exposed separately to the carbon black/polymer composite detectors under study. Similarly, when an analyte was exposed to the detectors on top of a background level of another analyte, the delta R/Rb values of the array of detectors were very close to those obtained when the test analyte was exposed to the detectors only in the presence of background air. The initial training requirements from the array response output data of such detectors are minimized because the delta R/Rb response pattern produced by the analyte of concern can be associated uniquely with that odor, under the conditions explored in this work.


Assuntos
Álcoois/química , Alcanos/química , Carbono/química , Polímeros/química , Técnicas de Química Analítica/métodos , Odorantes , Volatilização
2.
Proc Natl Acad Sci U S A ; 95(10): 5442-7, 1998 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-9576901

RESUMO

Response data were collected for a carbon black-polymer composite electronic nose array during exposure to homologous series of alkanes and alcohols. The mean response intensity of the electronic nose detectors and the response intensity of the most strongly driven set of electronic nose detectors were essentially constant for members of a chemically homologous odorant series when the concentration of each odorant in the gas phase was maintained at a constant fraction of the odorant's vapor pressure. A similar trend is observed in human odor detection threshold values for these same homologous series of odorants. Because the thermodynamic activity of an odorant at equilibrium in a sorbent phase is equal to the partial pressure of the odorant in the gas phase divided by the vapor pressure of the odorant and because the activity coefficients are similar within these homologous series of odorants for sorption of the vapors into specific polymer films, the data imply that the trends in detector response can be understood based on the thermodynamic tendency to establish a relatively constant concentration of sorbed odorant into each of the polymeric films of the electronic nose at a constant fraction of the odorant's vapor pressure. Similarly, the data are consistent with the hypothesis that the odor detection thresholds observed in human psychophysical experiments for the odorants studied herein are driven predominantly by the similarity in odorant concentrations sorbed into the olfactory epithelium at a constant fraction of the odorant's vapor pressure.


Assuntos
Técnicas Biossensoriais , Odorantes/análise , Receptores Odorantes/fisiologia , Olfato/fisiologia , Humanos , Polímeros , Pressão , Limiar Sensorial , Volatilização
3.
Anal Chem ; 70(7): 1440-3, 1998 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-21644739

RESUMO

Carbon black-chiral polymer composites were used to provide diagnostic differential resistance responses in the presence of enantiomers of chiral gaseous analytes. Vapors of (+)-2-butanol and (-)-2-butanol, (+)-α-pinene and (-)-α-pinene, (+)-epichlorohydrin and (-)-epichlorohydrin, and methyl (+)-2-chloropropionate and methyl (-)-2-chloropropionate were generated and passed over a chemically sensitive carbon black-poly((R)-3-hydroxybutyrate-co-(R)-3-hydroxyvalerate) (77% butyrate) composite resistor. Each enantiomer of a pair produced a distinct relative differential resistance change on the chiral detector, whereas both enantiomers of a set produced identical signals on achiral carbon black-poly(ethylene-co-vinyl acetate) (82% ethylene) detectors.

4.
Anal Chem ; 70(13): 2560-4, 1998 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-9666726

RESUMO

Compatible blends of poly(vinyl acetate) and poly(methyl methacrylate) have been used to produce a series of electrically conducting carbon black composites whose resistance is sensitive to the nature and concentration of an analyte in the vapor phase. The dc electrical resistance response of the composites was found to be a nonlinear function of the mole fraction of poly(vinyl acetate) in the blend. These compatible blend composite detectors provided additional analyte discrimination information relative to a reference detector array that only contained composites formed using the pure polymer phases. The added discrimination power provided by the compatible blend detectors, and thus the added diversity of the enhanced detector array, was quantified through use of a statistical metric to assess the performance of detector arrays in various vapor classification tasks.


Assuntos
Carbono/análise , Resinas Compostas/análise , Eletroquímica/métodos , Polimetil Metacrilato/química , Polivinil/química , Condutividade Elétrica , Matemática , Volatilização
5.
Anal Chem ; 70(19): 4177-90, 1998 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-21651255

RESUMO

A statistical metric, based on the magnitude and standard deviations along linear projections of clustered array response data, was utilized to facilitate an evaluation of the performance of detector arrays in various vapor classification tasks. This approach allowed quantification of the ability of a 14-element array of carbon black-insulating polymer composite chemiresistors to distinguish between members of a set of 19 solvent vapors, some of which vary widely in chemical properties (e.g., methanol and benzene) and others of which are very similar (e.g., n-pentane and n-heptane). The data also facilitated evaluation of questions such as the optimal number of detectors required for a specific task, whether improved performance is obtained by increasing the number of detectors in a detector array, and how to assess statistically the diversity of a collection of detectors in order to understand more fully which properties are underrepresented in a particular set of array elements. In addition, the resolving power of arrays of carbon black-polymer composites was compared to the resolving power of specific collections of bulk conducting organic polymer or tin oxide detector arrays in a common set of vapor classification tasks.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA