Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Biotechnol Bioeng ; 120(5): 1254-1268, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36633017

RESUMO

Effects of hemodynamic shear stress on endothelial cells have been extensively investigated using the "swirling well" method, in which cells are cultured in dishes or multiwell plates placed on an orbital shaker. A wave rotates around the well, producing complex patterns of shear. The method allows chronic exposure to flow with high throughput at low cost but has two disadvantages: a number of shear stress characteristics change in a broadly similar way from the center to the edge of the well, and cells at one location in the well may release mediators into the medium that affect the behavior of cells at other locations, exposed to different shears. These properties make it challenging to correlate cell properties with shear. The present study investigated simple alterations to ameliorate these issues. Flows were obtained by numerical simulation. Increasing the volume of fluid in the well-altered dimensional but not dimensionless shear metrics. Adding a central cylinder to the base of the well-forced fluid to flow in a square toroidal channel and reduced multidirectionality. Conversely, suspending a cylinder above the base of the well made the flow highly multidirectional. Increasing viscosity in the latter model increased the magnitude of dimensional but not dimensionless metrics. Finally, tilting the well changed the patterns of different wall shear stress metrics in different ways. Collectively, these methods allow similar flows over most of the cells cultured and/or allow the separation of different shear metrics. A combination of the methods overcomes the limitations of the baseline model.


Assuntos
Técnicas de Cultura de Células , Células Endoteliais , Hemodinâmica , Simulação por Computador , Estresse Mecânico
2.
Biotechnol Bioeng ; 119(1): 72-88, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34612513

RESUMO

Effects of fluid dynamics on cells are often studied by growing the cells on the base of cylindrical wells or dishes that are swirled on the horizontal platform of an orbital shaker. The swirling culture medium applies a shear stress to the cells that varies in magnitude and directionality from the center to the edge of the vessel. Computational fluid dynamics methods are used to simulate the flow and hence calculate shear stresses at the base of the well. The shear characteristics at each radial location are then compared with cell behavior at the same position. Previous simulations have generally ignored effects of surface tension and wetting, and results have only occasionally been experimentally validated. We investigated whether such idealized simulations are sufficiently accurate, examining a commonly-used swirling well configuration. The breaking wave predicted by earlier simulations was not seen, and the edge-to-center difference in shear magnitude (but not directionality) almost disappeared, when surface tension and wetting were included. Optical measurements of fluid height and velocity agreed well only with the computational model that incorporated surface tension and wetting. These results demonstrate the importance of including accurate fluid properties in computational models of the swirling well method.


Assuntos
Técnicas de Cultura de Células , Simulação por Computador , Hidrodinâmica , Modelos Biológicos , Células Endoteliais/citologia , Resistência ao Cisalhamento , Estresse Mecânico
3.
Am J Physiol Heart Circ Physiol ; 320(2): H494-H510, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33064563

RESUMO

Central blood pressure (cBP) is a highly prognostic cardiovascular (CV) risk factor whose accurate, invasive assessment is costly and carries risks to patients. We developed and assessed novel algorithms for estimating cBP from noninvasive aortic hemodynamic data and a peripheral blood pressure measurement. These algorithms were created using three blood flow models: the two- and three-element Windkessel (0-D) models and a one-dimensional (1-D) model of the thoracic aorta. We tested new and existing methods for estimating CV parameters (left ventricular ejection time, outflow BP, arterial resistance and compliance, pulse wave velocity, and characteristic impedance) required for the cBP algorithms, using virtual (simulated) subjects (n = 19,646) for which reference CV parameters were known exactly. We then tested the cBP algorithms using virtual subjects (n = 4,064), for which reference cBP were available free of measurement error, and clinical datasets containing invasive (n = 10) and noninvasive (n = 171) reference cBP waves across a wide range of CV conditions. The 1-D algorithm outperformed the 0-D algorithms when the aortic vascular geometry was available, achieving central systolic blood pressure (cSBP) errors ≤ 2.1 ± 9.7 mmHg and root-mean-square errors (RMSEs) ≤ 6.4 ± 2.8 mmHg against invasive reference cBP waves (n = 10). When the aortic geometry was unavailable, the three-element 0-D algorithm achieved cSBP errors ≤ 6.0 ± 4.7 mmHg and RMSEs ≤ 5.9 ± 2.4 mmHg against noninvasive reference cBP waves (n = 171), outperforming the two-element 0-D algorithm. All CV parameters were estimated with mean percentage errors ≤ 8.2%, except for the aortic characteristic impedance (≤13.4%), which affected the three-element 0-D algorithm's performance. The freely available algorithms developed in this work enable fast and accurate calculation of the cBP wave and CV parameters in datasets containing noninvasive ultrasound or magnetic resonance imaging data.NEW & NOTEWORTHY First, our proposed methods for CV parameter estimation and a comprehensive set of methods from the literature were tested using in silico and clinical datasets. Second, optimized algorithms for estimating cBP from aortic flow were developed and tested for a wide range of cBP morphologies, including catheter cBP data. Third, a dataset of simulated cBP waves was created using a three-element Windkessel model. Fourth, the Windkessel model dataset and optimized algorithms are freely available.


Assuntos
Aorta Torácica/fisiologia , Circulação Sanguínea , Pressão Sanguínea , Doenças Cardiovasculares/fisiopatologia , Modelos Cardiovasculares , Adolescente , Adulto , Algoritmos , Aorta Torácica/fisiopatologia , Criança , Feminino , Humanos , Masculino
4.
Am J Physiol Heart Circ Physiol ; 313(5): H959-H973, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-28754719

RESUMO

Transport of macromolecules across vascular endothelium and its modification by fluid mechanical forces are important for normal tissue function and in the development of atherosclerosis. However, the routes by which macromolecules cross endothelium, the hemodynamic stresses that maintain endothelial physiology or trigger disease, and the dependence of transendothelial transport on hemodynamic stresses are controversial. We visualized pathways for macromolecule transport and determined the effect on these pathways of different types of flow. Endothelial monolayers were cultured under static conditions or on an orbital shaker producing different flow profiles in different parts of the wells. Fluorescent tracers that bound to the substrate after crossing the endothelium were used to identify transport pathways. Maps of tracer distribution were compared with numerical simulations of flow to determine effects of different shear stress metrics on permeability. Albumin-sized tracers dominantly crossed the cultured endothelium via junctions between neighboring cells, high-density lipoprotein-sized tracers crossed at tricellular junctions, and low-density lipoprotein-sized tracers crossed through cells. Cells aligned close to the angle that minimized shear stresses across their long axis. The rate of paracellular transport under flow correlated with the magnitude of these minimized transverse stresses, whereas transport across cells was uniformly reduced by all types of flow. These results contradict the long-standing two-pore theory of solute transport across microvessel walls and the consensus view that endothelial cells align with the mean shear vector. They suggest that endothelial cells minimize transverse shear, supporting its postulated proatherogenic role. Preliminary data show that similar tracer techniques are practicable in vivo.NEW & NOTEWORTHY Solutes of increasing size crossed cultured endothelium through intercellular junctions, through tricellular junctions, or transcellularly. Cells aligned to minimize the shear stress acting across their long axis. Paracellular transport correlated with the level of this minimized shear, but transcellular transport was reduced uniformly by flow regardless of the shear profile.


Assuntos
Endotélio Vascular/metabolismo , Substâncias Macromoleculares/metabolismo , Algoritmos , Animais , Aorta/citologia , Aorta/metabolismo , Transporte Biológico Ativo , Núcleo Celular/metabolismo , Núcleo Celular/ultraestrutura , Células Cultivadas , Células Endoteliais/metabolismo , Endotélio Vascular/ultraestrutura , Junções Intercelulares/metabolismo , Lipoproteínas LDL/metabolismo , Estresse Mecânico , Suínos
5.
Arterioscler Thromb Vasc Biol ; 34(5): 985-95, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24651677

RESUMO

OBJECTIVE: Although atherosclerosis is associated with systemic risk factors such as age, high cholesterol, and obesity, plaque formation occurs predominately at branches and bends that are exposed to disturbed patterns of blood flow. The molecular mechanisms that link disturbed flow-generated mechanical forces with arterial injury are uncertain. To illuminate them, we investigated the effects of flow on endothelial cell (EC) senescence. APPROACH AND RESULTS: LDLR(-/-) (low-density lipoprotein receptor(-/-)) mice were exposed to a high-fat diet for 2 to 12 weeks (or to a normal chow diet as a control) before the assessment of cellular senescence in aortic ECs. En face staining revealed that senescence-associated ß-galactosidase activity and p53 expression were elevated in ECs at sites of disturbed flow in response to a high-fat diet. By contrast, ECs exposed to undisturbed flow did not express senescence-associated ß-galactosidase or p53. Studies of aortae from healthy pigs (aged 6 months) also revealed enhanced senescence-associated ß-galactosidase staining at sites of disturbed flow. These data suggest that senescent ECs accumulate at disturbed flow sites during atherogenesis. We used in vitro flow systems to examine whether a causal relationship exists between flow and EC senescence. Exposure of cultured ECs to flow (using either an orbital shaker or a syringe-pump flow bioreactor) revealed that disturbed flow promoted EC senescence compared with static conditions, whereas undisturbed flow reduced senescence. Gene silencing studies demonstrated that disturbed flow induced EC senescence via a p53-p21 signaling pathway. Disturbed flow-induced senescent ECs exhibited reduced migration compared with nonsenescent ECs in a scratch wound closure assay, and thus may be defective for arterial repair. However, pharmacological activation of sirtuin 1 (using resveratrol or SRT1720) protected ECs from disturbed flow-induced senescence. CONCLUSIONS: Disturbed flow promotes endothelial senescence via a p53-p21-dependent pathway which can be inhibited by activation of sirtuin 1. These observations support the principle that pharmacological activation of sirtuin 1 may promote cardiovascular health by suppressing EC senescence at atheroprone sites.


Assuntos
Doenças da Aorta/metabolismo , Aterosclerose/metabolismo , Senescência Celular , Células Endoteliais/metabolismo , Mecanotransdução Celular , Proteína Supressora de Tumor p53/metabolismo , Animais , Doenças da Aorta/genética , Doenças da Aorta/patologia , Doenças da Aorta/fisiopatologia , Aterosclerose/genética , Aterosclerose/patologia , Aterosclerose/fisiopatologia , Reatores Biológicos , Movimento Celular , Células Cultivadas , Senescência Celular/efeitos dos fármacos , Inibidor de Quinase Dependente de Ciclina p21/genética , Inibidor de Quinase Dependente de Ciclina p21/metabolismo , Dieta Hiperlipídica , Modelos Animais de Doenças , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/patologia , Ativação Enzimática , Ativadores de Enzimas/farmacologia , Células Endoteliais da Veia Umbilical Humana/metabolismo , Células Endoteliais da Veia Umbilical Humana/patologia , Humanos , Mecanotransdução Celular/efeitos dos fármacos , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Interferência de RNA , Receptores de LDL/deficiência , Receptores de LDL/genética , Fluxo Sanguíneo Regional , Sirtuína 1/metabolismo , Estresse Mecânico , Suínos , Fatores de Tempo , Transfecção , Proteína Supressora de Tumor p53/genética , Cicatrização
6.
J Biomech Eng ; 135(2): 021023, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23445068

RESUMO

Studies investigating the relation between the focal nature of atherosclerosis and hemodynamic factors are employing increasingly rigorous approaches to map the disease and calculate hemodynamic metrics. However, no standardized methodology exists to quantitatively compare these distributions. We developed a statistical technique that can be used to determine if hemodynamic and lesion maps are significantly correlated. The technique, which is based on a surrogate data analysis, does not require any assumptions (such as linearity) on the nature of the correlation. Randomized sampling was used to ensure the independence of data points, another basic assumption of commonly-used statistical methods that is often disregarded. The novel technique was used to compare previously-obtained maps of lesion prevalence in aortas of immature and mature cholesterol-fed rabbits to corresponding maps of wall shear stress, averaged across several animals in each age group. A significant spatial correlation was found in the proximal descending thoracic aorta, but not further downstream. Around intercostal branch openings the correlation was borderline significant in immature but not in mature animals. The results confirm the need for further investigation of the relation between the localization of atherosclerosis and blood flow, in conjunction with appropriate statistical techniques such as the method proposed here.


Assuntos
Aterosclerose/fisiopatologia , Hemodinâmica , Estatística como Assunto/métodos , Animais , Modelos Lineares , Coelhos , Reprodutibilidade dos Testes , Análise Espacial
7.
J Biomech Eng ; 135(2): 021016, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23445061

RESUMO

Stimulated by a recent controversy regarding pressure drops predicted in a giant aneurysm with a proximal stenosis, the present study sought to assess variability in the prediction of pressures and flow by a wide variety of research groups. In phase I, lumen geometry, flow rates, and fluid properties were specified, leaving each research group to choose their solver, discretization, and solution strategies. Variability was assessed by having each group interpolate their results onto a standardized mesh and centerline. For phase II, a physical model of the geometry was constructed, from which pressure and flow rates were measured. Groups repeated their simulations using a geometry reconstructed from a micro-computed tomography (CT) scan of the physical model with the measured flow rates and fluid properties. Phase I results from 25 groups demonstrated remarkable consistency in the pressure patterns, with the majority predicting peak systolic pressure drops within 8% of each other. Aneurysm sac flow patterns were more variable with only a few groups reporting peak systolic flow instabilities owing to their use of high temporal resolutions. Variability for phase II was comparable, and the median predicted pressure drops were within a few millimeters of mercury of the measured values but only after accounting for submillimeter errors in the reconstruction of the life-sized flow model from micro-CT. In summary, pressure can be predicted with consistency by CFD across a wide range of solvers and solution strategies, but this may not hold true for specific flow patterns or derived quantities. Future challenges are needed and should focus on hemodynamic quantities thought to be of clinical interest.


Assuntos
Aneurisma/fisiopatologia , Bioengenharia , Circulação Sanguínea , Simulação por Computador , Hidrodinâmica , Pressão , Congressos como Assunto , Humanos , Cinética , Sociedades Científicas
8.
Front Bioeng Biotechnol ; 10: 962687, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36017352

RESUMO

The patchy distribution of atherosclerosis within the arterial system is consistent with a controlling influence of hemodynamic wall shear stress (WSS). Patterns of low, oscillatory and transverse WSS have been invoked to explain the distribution of disease in the aorta. Disease of coronary arteries has greater clinical importance but blood flow in these vessels may be complicated by their movement during the cardiac cycle. Previous studies have shown that time average WSS is little affected by the dynamic geometry, and that oscillatory shear is influenced more. Here we additionally investigate effects on transverse WSS. We also investigate the influence of non-Newtonian blood rheology as it can influence vortical structure, on which transverse WSS depends; Carreau-Yasuda models were used. WSS metrics were derived from numerical simulations of blood flow in a model of a moving right coronary artery which, together with a subject-specific inflow waveform, was obtained by MR imaging of a healthy human subject in a previous study. The results confirmed that time average WSS was little affected by dynamic motion and that oscillatory WSS was more affected. They additionally showed that transverse WSS and its non-dimensional analogue, the Cross Flow Index, were affected still further. This appeared to reflect time-varying vortical structures caused by the changes in curvature. The influence of non-Newtonian rheology was significant with some physiologically realistic parameter values, and hence may be important in certain subjects. Dynamic geometry and non-Newtonian rheology should be incorporated into models designed to produce maps of transverse WSS in coronary arteries.

9.
Front Bioeng Biotechnol ; 9: 737055, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35004634

RESUMO

Heart failure is treatable, but in the United Kingdom, the 1-, 5- and 10-year mortality rates are 24.1, 54.5 and 75.5%, respectively. The poor prognosis reflects, in part, the lack of specific, simple and affordable diagnostic techniques; the disease is often advanced by the time a diagnosis is made. Previous studies have demonstrated that certain metrics derived from pressure-velocity-based wave intensity analysis are significantly altered in the presence of impaired heart performance when averaged over groups, but to date, no study has examined the diagnostic potential of wave intensity on an individual basis, and, additionally, the pressure waveform can only be obtained accurately using invasive methods, which has inhibited clinical adoption. Here, we investigate whether a new form of wave intensity based on noninvasive measurements of arterial diameter and velocity can detect impaired heart performance in an individual. To do so, we have generated a virtual population of two-thousand elderly subjects, modelling half as healthy controls and half with an impaired stroke volume. All metrics derived from the diameter-velocity-based wave intensity waveforms in the carotid, brachial and radial arteries showed significant crossover between groups-no one metric in any artery could reliably indicate whether a subject's stroke volume was normal or impaired. However, after applying machine learning to the metrics, we found that a support vector classifier could simultaneously achieve up to 99% recall and 95% precision. We conclude that noninvasive wave intensity analysis has significant potential to improve heart failure screening and diagnosis.

10.
J R Soc Interface ; 18(174): 20200772, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33435845

RESUMO

The alignment of arterial endothelial cells (ECs) with the mean wall shear stress (WSS) vector is the prototypical example of their responsiveness to flow. However, evidence for this behaviour rests on experiments where many WSS metrics had the same orientation or where they were incompletely characterized. In the present study, we tested the phenomenon more rigorously. Aortic ECs were cultured in cylindrical wells on the platform of an orbital shaker. In this system, orientation would differ depending on the WSS metric to which the cells aligned. Variation in flow features and hence in possible orientations was further enhanced by altering the viscosity of the medium. Orientation of endothelial nuclei was compared with WSS characteristics obtained by computational fluid dynamics. At low mean WSS magnitudes, ECs aligned with the modal WSS vector, while at high mean WSS magnitudes they aligned so as to minimize the shear acting across their long axis (transverse WSS). Their failure to align with the mean WSS vector implies that other aspects of endothelial behaviour attributed to this metric require re-examination. The evolution of a mechanism for minimizing transverse WSS is consistent with it having detrimental effects on the cells and with its putative role in atherogenesis.


Assuntos
Aterosclerose , Células Endoteliais , Aorta , Humanos , Hidrodinâmica , Resistência ao Cisalhamento , Estresse Mecânico
11.
Proc Inst Mech Eng H ; 234(11): 1260-1276, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32650691

RESUMO

Pressure-velocity-based analysis of arterial wave intensity gives clinically relevant information about the performance of the heart and vessels, but its utility is limited because accurate pressure measurements can only be obtained invasively. Diameter-velocity-based wave intensity can be obtained noninvasively using ultrasound; however, due to the nonlinear relationship between blood pressure and arterial diameter, the two wave intensities might give disparate clinical indications. To test the magnitude of the disagreement, we have generated an age-stratified virtual population to investigate how the two dominant nonlinearities viscoelasticity and strain-stiffening cause the two formulations to differ. We found strong agreement between the pressure-velocity and diameter-velocity methods, particularly for the systolic wave energy, the ratio between systolic and diastolic wave heights, and older subjects. The results are promising regarding the introduction of noninvasive wave intensities in the clinic.


Assuntos
Artérias , Adulto , Artérias/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Humanos , Ultrassonografia
12.
Biophys J ; 96(8): 3102-15, 2009 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-19383456

RESUMO

Uptake of low density lipoprotein (LDL) by the arterial wall is likely to play a key role in atherogenesis. A particular process that may cause vascular scale heterogeneity in the rate of transendothelial LDL transport is the formation of a flow-dependent LDL concentration polarization layer on the luminal surface of the arterial endothelium. In this study, the effect of a spatially heterogeneous transmural water flux (that traverses the endothelium only via interendothelial cell clefts) on such concentration polarization is investigated numerically. Unlike in previous investigations, realistic intercellular cleft dimensions are used here and several values of LDL diffusivity are considered. Particular attention is paid to the spatially averaged LDL concentration adjacent to different regions of the endothelial surface, as such measures may be relevant to the rate of transendothelial LDL transport. It is demonstrated in principle that a heterogeneous transmural water flux can act to enhance such measures, and cause them to develop a shear dependence (in addition to that caused by vascular scale flow features, affecting the overall degree of LDL concentration polarization). However, it is shown that this enhancement and additional shear dependence are likely to be negligible for a physiologically realistic transmural flux velocity of 0.0439 mum s(-1) and an LDL diffusivity (in blood plasma) of 28.67 mum(2) s(-1). Hence, the results imply that vascular scale studies of LDL concentration polarization are justified in ignoring the effect of a spatially heterogeneous transmural water flux.


Assuntos
Artérias/metabolismo , Transporte Biológico , Endotélio Vascular/metabolismo , Lipoproteínas LDL/metabolismo , Modelos Cardiovasculares , Água/metabolismo , Algoritmos , Simulação por Computador , Lipoproteínas LDL/sangue
13.
J Biomech ; 40(15): 3476-86, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17640653

RESUMO

A numerical model based on the nonlinear, one-dimensional (1-D) equations of pressure and flow wave propagation in conduit arteries is tested against a well-defined experimental 1:1 replica of the human arterial tree. The tree consists of 37 silicone branches representing the largest central systemic arteries in the human, including the aorta, carotid arteries and arteries that perfuse the upper and lower limbs and the main abdominal organs. The set-up is mounted horizontally and connected to a pulsatile pump delivering a periodic output similar to the aortic flow. Terminal branches end in simple resistance models, consisting of stiff capillary tubes leading to an overflow reservoir that reflects a constant venous pressure. The parameters required by the numerical algorithm are directly measured in the in vitro set-up and no data fitting is involved. Comparison of experimental and numerical pressure and flow waveforms shows the ability of the 1-D time-domain formulation to capture the main features of pulse wave propagation measured throughout the system test. As a consequence of the simple resistive boundary conditions used to reduce the uncertainty of the parameters involved in the simulation, the experimental set-up generates waveforms at terminal branches with additional non-physiological oscillations. The frequencies of these oscillations are well captured by the 1-D model, even though amplitudes are overestimated. Adding energy losses in bifurcations and including fluid inertia and compliance to the purely resistive terminal models does not reduce the underdamped effect, suggesting that wall visco-elasticity might play an important role in the experimental results. Nevertheless, average relative root-mean-square errors between simulations and experimental waveforms are smaller than 4% for pressure and 19% for the flow at all 70 locations studied.


Assuntos
Artérias/fisiologia , Modelos Biológicos , Simulação por Computador , Humanos , Pressão
14.
J Biomech ; 50: 102-109, 2017 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-27863740

RESUMO

The patchy distribution of atherosclerosis within arteries is widely attributed to local variation in haemodynamic wall shear stress (WSS). A recently-introduced metric, the transverse wall shear stress (transWSS), which is the average over the cardiac cycle of WSS components perpendicular to the temporal mean WSS vector, correlates particularly well with the pattern of lesions around aortic branch ostia. Here we use numerical methods to investigate the nature of the arterial flows captured by transWSS and the sensitivity of transWSS to inflow waveform and aortic geometry. TransWSS developed chiefly in the acceleration, peak systolic and deceleration phases of the cardiac cycle; the reverse flow phase was too short, and WSS in diastole was too low, for these periods to have a significant influence. Most of the spatial variation in transWSS arose from variation in the angle by which instantaneous WSS vectors deviated from the mean WSS vector rather than from variation in the magnitude of the vectors. The pattern of transWSS was insensitive to inflow waveform; only unphysiologically high Womersley numbers produced substantial changes. However, transWSS was sensitive to changes in geometry. The curvature of the arch and proximal descending aorta were responsible for the principal features, the non-planar nature of the aorta produced asymmetries in the location and position of streaks of high transWSS, and taper determined the persistence of the streaks down the aorta. These results reflect the importance of the fluctuating strength of Dean vortices in generating transWSS.


Assuntos
Aorta Torácica/patologia , Aterosclerose/patologia , Algoritmos , Aorta Torácica/fisiopatologia , Aterosclerose/fisiopatologia , Fenômenos Biomecânicos , Velocidade do Fluxo Sanguíneo , Hemodinâmica , Humanos , Hidrodinâmica , Modelos Cardiovasculares , Fluxo Sanguíneo Regional
15.
Artigo em Inglês | MEDLINE | ID: mdl-26736675

RESUMO

Registration of electroanatomic surfaces and segmented images for the co-localisation of structural and functional data typically requires the manual selection of fiducial points, which are used to initialise automated surface registration. The identification of equivalent points on geometric features by the human eye is heavily subjective, and error in their selection may lead to distortion of the transformed surface and subsequently limit the accuracy of data co-localisation. We propose that the manual trimming of the pulmonary veins through the region of greatest geometrical curvature, coupled with an automated angle-based fiducial-point selection algorithm, significantly reduces target registration error compared with direct manual selection of fiducial points.


Assuntos
Átrios do Coração/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Veias Pulmonares/anatomia & histologia , Algoritmos , Diagnóstico por Imagem , Eletrocardiografia , Humanos
16.
Ann Biomed Eng ; 43(1): 16-25, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25138165

RESUMO

The non-uniform distribution of atherosclerosis within the arterial system has been attributed to pro-atherogenic influences of low, oscillatory haemodynamic wall shear stress (WSS) on endothelial cells (EC). This theory is challenged by the changes in lesion location that occur with age in human and rabbit aortas. Furthermore, a number of point-wise comparisons of lesion prevalence and WSS have failed to support it. Here we investigate the hypothesis that multidirectional flow-characterized as the average magnitude of WSS components acting transversely to the mean vector (transWSS)-plays a key role. Maps of lesion prevalence around aortic branch ostia in immature and mature rabbits were compared with equivalent maps of time average WSS, the OSI (an index characterizing oscillatory flow) and transWSS, obtained from computational simulations; Spearman's rank correlation coefficients were calculated for aggregated data and 95% confidence intervals were obtained by bootstrapping methods. Lesion prevalence correlated positively, strongly and significantly with transWSS at both ages. Correlations of lesion prevalence with the other shear metrics were not significant or were significantly lower than those obtained for transWSS. No correlation supported the low, oscillatory WSS theory. The data are consistent with the view that multidirectional near-wall flow is highly pro-atherogenic. Effects of multidirectional flow on EC, and methods for investigating them, are reviewed. The finding that oscillatory flow has pro-inflammatory effects when acting perpendicularly to the long axis of EC but anti-inflammatory effects when acting parallel to it may explain the stronger correlation of lesion prevalence with transWSS than with the OSI.


Assuntos
Aterosclerose/fisiopatologia , Hemorreologia , Animais , Aorta/patologia , Aorta/fisiopatologia , Aterosclerose/patologia , Fenômenos Biomecânicos , Humanos , Hidrodinâmica , Masculino , Coelhos
17.
J Comput Phys ; 257(PA): 813-829, 2014 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-24748685

RESUMO

We present a numerical discretisation of an embedded two-dimensional manifold using high-order continuous Galerkin spectral/hp elements, which provide exponential convergence of the solution with increasing polynomial order, while retaining geometric flexibility in the representation of the domain. Our work is motivated by applications in cardiac electrophysiology where sharp gradients in the solution benefit from the high-order discretisation, while the computational cost of anatomically-realistic models can be significantly reduced through the surface representation and use of high-order methods. We describe and validate our discretisation and provide a demonstration of its application to modelling electrochemical propagation across a human left atrium.

18.
PLoS One ; 9(12): e115728, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25531765

RESUMO

Atherosclerosis may be triggered by an elevated net transport of lipid-carrying macromolecules from plasma into the arterial wall. We hypothesised that whether lesions are of the thin-cap fibroatheroma (TCFA) type or are less fatty and more fibrous depends on the degree of elevation of transport, with greater uptake leading to the former. We further hypothesised that the degree of elevation can depend on haemodynamic wall shear stress characteristics and nitric oxide synthesis. Placing a tapered cuff around the carotid artery of apolipoprotein E -/- mice modifies patterns of shear stress and eNOS expression, and triggers lesion development at the upstream and downstream cuff margins; upstream but not downstream lesions resemble the TCFA. We measured wall uptake of a macromolecular tracer in the carotid artery of C57bl/6 mice after cuff placement. Uptake was elevated in the regions that develop lesions in hyperlipidaemic mice and was significantly more elevated where plaques of the TCFA type develop. Computational simulations and effects of reversing the cuff orientation indicated a role for solid as well as fluid mechanical stresses. Inhibiting NO synthesis abolished the difference in uptake between the upstream and downstream sites. The data support the hypothesis that excessively elevated wall uptake of plasma macromolecules initiates the development of the TCFA, suggest that such uptake can result from solid and fluid mechanical stresses, and are consistent with a role for NO synthesis. Modification of wall transport properties might form the basis of novel methods for reducing plaque rupture.


Assuntos
Apolipoproteínas E/fisiologia , Aterosclerose/fisiopatologia , Artérias Carótidas/patologia , Modelos Animais de Doenças , Substâncias Macromoleculares/farmacocinética , Placa Aterosclerótica/fisiopatologia , Estresse Mecânico , Animais , Aterosclerose/etiologia , Fenômenos Biomecânicos , Artérias Carótidas/cirurgia , Simulação por Computador , Hemodinâmica , Processamento de Imagem Assistida por Computador , Substâncias Macromoleculares/sangue , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Microscopia Confocal , Placa Aterosclerótica/etiologia , Distribuição Tecidual
19.
Artigo em Inglês | MEDLINE | ID: mdl-25570274

RESUMO

Determining locations of focal arrhythmia sources and quantifying myocardial conduction velocity (CV) are two major challenges in clinical catheter ablation cases. CV, wave-front direction and focal source location can be estimated from multipolar catheter data, but currently available methods are time-consuming, limited to specific electrode configurations, and can be inaccurate. We developed automated algorithms to rapidly identify CV from multipolar catheter data with any arrangement of electrodes, whilst providing estimates of wavefront direction and focal source position, which can guide the catheter towards a focal arrhythmic source. We validated our methods using simulations on realistic human left atrial geometry. We subsequently applied them to clinically-acquired intracardiac electrogram data, where CV and wavefront direction were accurately determined in all cases, whilst focal source locations were correctly identified in 2/3 cases. Our novel automated algorithms can potentially be used to guide ablation of focal arrhythmias in real-time in cardiac catheter laboratories.


Assuntos
Algoritmos , Arritmias Cardíacas/fisiopatologia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Simulação por Computador , Átrios do Coração/fisiopatologia , Humanos , Processamento de Sinais Assistido por Computador
20.
Cardiovasc Res ; 99(2): 242-50, 2013 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-23459102

RESUMO

Low and oscillatory wall shear stress is widely assumed to play a key role in the initiation and development of atherosclerosis. Indeed, some studies have relied on the low shear theory when developing diagnostic and treatment strategies for cardiovascular disease. We wished to ascertain if this consensus is justified by published data. We performed a systematic review of papers that compare the localization of atherosclerotic lesions with the distribution of haemodynamic indicators calculated using computational fluid dynamics. The review showed that although many articles claim their results conform to the theory, it has been interpreted in different ways: a range of metrics has been used to characterize the distribution of disease, and they have been compared with a range of haemodynamic factors. Several studies, including all of those making systematic point-by-point comparisons of shear and disease, failed to find the expected relation. The various pre- and post-processing techniques used by different groups have reduced the range of shears over which correlations were sought, and in some cases are mutually incompatible. Finally, only a subset of the known patterns of disease has been investigated. The evidence for the low/oscillatory shear theory is less robust than commonly assumed. Longitudinal studies starting from the healthy state, or the collection of average flow metrics derived from large numbers of healthy vessels, both in conjunction with point-by-point comparisons using appropriate statistical techniques, will be necessary to improve our understanding of the relation between blood flow and atherogenesis.


Assuntos
Aterosclerose/fisiopatologia , Vasos Sanguíneos/fisiopatologia , Hemodinâmica , Mecanotransdução Celular , Animais , Aterosclerose/metabolismo , Aterosclerose/patologia , Fenômenos Biomecânicos , Vasos Sanguíneos/metabolismo , Vasos Sanguíneos/patologia , Progressão da Doença , Humanos , Modelos Cardiovasculares , Placa Aterosclerótica , Fluxo Sanguíneo Regional , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA