RESUMO
Conditions to which the cardiac graft is exposed during transplantation with donation after circulatory death (DCD) can trigger the recruitment of macrophages that are either unpolarized (M0) or pro-inflammatory (M1) as well as the release of extracellular vesicles (EV). We aimed to characterize the effects of M0 and M1 macrophage-derived EV administration on post-ischaemic functional recovery and glucose metabolism using an isolated rat heart model of DCD. Isolated rat hearts were subjected to 20 min aerobic perfusion, followed by 27 min global, warm ischaemia or continued aerobic perfusion and 60 min reperfusion with or without intravascular administration of EV. Four experimental groups were compared: (1) no ischaemia, no EV; (2) ischaemia, no EV; (3) ischaemia with M0-macrophage-dervied EV; (4) ischaemia with M1-macrophage-derived EV. Post-ischaemic ventricular and metabolic recovery were evaluated. During reperfusion, ventricular function was decreased in untreated ischaemic and M1-EV hearts, but not in M0-EV hearts, compared to non-ischaemic hearts (p < 0.05). In parallel with the reduced functional recovery in M1-EV versus M0-EV ischaemic hearts, rates of glycolysis from exogenous glucose and oxidative metabolism tended to be lower, while rates of glycogenolysis and lactate release tended to be higher. EV from M0- and M1-macrophages differentially affect post-ischaemic cardiac recovery, potentially by altering glucose metabolism in a rat model of DCD. Targeted EV therapy may be a useful approach for modulating cardiac energy metabolism and optimizing graft quality in the setting of DCD.
Assuntos
Vesículas Extracelulares , Transplante de Coração , Macrófagos , Animais , Vesículas Extracelulares/metabolismo , Vesículas Extracelulares/transplante , Ratos , Macrófagos/metabolismo , Masculino , Transplante de Coração/métodos , Glucose/metabolismo , Miocárdio/metabolismo , Modelos Animais de Doenças , Recuperação de Função Fisiológica , Glicólise , Coração/fisiopatologia , Coração/fisiologiaRESUMO
BACKGROUND: Hyperglycemia is common in patients undergoing cardiovascular surgery with cardiopulmonary bypass. We hypothesize that intraoperative hyperglycemia may be, at least partially, attributable to insulin loss due to adhesion on artificial surfaces and/or degradation by hemolysis. Thus, our primary aim was to investigate the loss of insulin in 2 different isolated extracorporeal circulation circuits (ECCs), that is, a conventional ECC (cECC) with a roller pump, and a mini-ECC (MiECC) system with a centrifugal pump. The secondary aim was to assess and compare the relationship between changes in insulin concentration and the degree of hemolysis in our 2 ECC models. METHODS: Six cECC and 6 MiECC systems were primed with red packed blood cells and thawed fresh-frozen plasma (1:1). Four additional experiments were performed in cECC using only thawed fresh-frozen plasma. Human insulin (Actrapid) was added, targeting a plasma insulin concentration of 400 mU/L. Insulin concentration and hemolysis index were measured at baseline and hourly thereafter. The end points were the change in insulin level after 4 hours compared to baseline and hemolysis index after 4 hours. The insulin concentration and hemolysis index were analyzed by means of a saturated linear mixed-effect regression model with a random offset for each experiment to account for the repeated measure design of the study, resulting in mean estimates and 95% confidence intervals (CIs) of the primary end points as well as of pairwise contrasts with respect to ECC type. RESULTS: Insulin concentration decreased by 63% (95% CI, 48%-77%) in the MiECC and 92% (95% CI, 77%-106%) in the cECC system that contained red blood cells. Insulin loss was significantly higher in the cECC system compared to the MiECC (P = .022). In the cECC with only plasma, insulin did not significantly decrease (-4%; 95% CI, -21% to 14%). Hemolysis index in MiECC increased from 68 (95% CI, 46-91) to 76 (95% CI, 54-98) after 4 hours, in cECC from 81 (95% CI, 59-103) to 121 (95% CI, 99-143). Hemolysis index and percent change of insulin showed an excellent relationship (r = -0.99, P < .01). CONCLUSIONS: Our data showed that insulin levels substantially decreased during 4 hours of simulated cardiopulmonary bypass only in the ECC that contained hemoglobin. The decrease was more pronounced in the cECC, which also exhibited a greater degree of hemolysis. Our results suggest that insulin degradation by hemolysis products may be a stronger contributor to insulin loss than adhesion of insulin molecules to circuit surfaces.
RESUMO
BACKGROUND: This study evaluated the hemodynamic performance of arterial and venous cannulae in a compliant pediatric extracorporeal membrane oxygenation (ECMO) mock circuit in pulsatile and non-pulsatile flow conditions. METHODS: The ECMO setup consisted of an oxygenator, diagonal pump, and standardized-length arterial/venous tubing with pressure transducers. A validated left-heart mock loop was adapted to simulate pediatric conditions. The pulsatile flow was driven by a computer-controlled piston pump set at 120 bpm. A roller pump was used for non-pulsatile conditions. The circuit was primed with 40% glycerol-based solution. The cardiac output was set to 1 L/min and the aortic pressure to 40-50 mmHg. Four arterial cannulae (8Fr, 10Fr, 12Fr, 14Fr) and five venous cannulae (12Fr, 14Fr, 16Fr, 18Fr, 20Fr) (Medtronic, Inc., Minneapolis, MN, USA) were tested at increasing flow rate in 12 combinations. RESULTS: The pulsatile condition required lower ECMO pump speeds for all cannulae combinations at a given flow rate, inducing a significantly smaller increase of flow in the mock loop. Under non-pulsatile conditions, the aortic and arterial pressures in the cannulae were higher (p < 0.01) while no significant differences in pressure drop and pressure-flow characteristics (M-number) were observed. The total hemodynamic energy was higher in case of non-pulsatile flow (p < 0.01). CONCLUSION: Under non-pulsatile conditions, the system was characterized by overall higher pressures, resulting in higher support to the patient. The consequent increase of potential energy compensates for increases of kinetic energy, leading to a higher total hemodynamic energy. Pressure gradients and M number are independent of the testing conditions. Pulsatile testing conditions led to more physiological testing conditions, and it is recommended for ECMO testing.
RESUMO
OBJECTIVE: Minimally invasive extracorporeal circulation has been shown to be non-inferior or even superior to conventional cardiopulmonary bypass circuits in isolated coronary artery bypass grafting, but there is little evidence whether the addition of a heparin-coated circuit can further reduce the inflammatory response and amount of bleeding in these patients. METHODS: A single-center randomized control trial enrolled 49 adult patients scheduled to undergo isolated coronary artery bypass grafting with minimally invasive extracorporeal circulation (MiECC) between January 2015 and December 2018. Patients were randomized 1:1 to either the heparin-coated circuit group, or the uncoated (control) circuit group. The primary outcome was chest tube output 18 h after weaning from MiECC, and secondary outcomes included inflammatory (TNF-α, IL-6, IL-8, IL-10) and complement (C3a, C4d, C5a, sC5b-9) biomarkers, platelet count and function (D2D, TAT, SDC1, PF4), number of transfused blood products, and 30-day survival. RESULTS: Patients were randomized to undergo myocardial revascularization using heparin-coated circuits (n = 25), and to the uncoated MiECC circuit (n = 24), with comparable baseline demographics. No significant difference was observed in chest tube output and for all secondary outcomes. IL-6 and IL-8 were increased from baseline at 18 h after weaning (effect size 0.29 and 0.05, respectively) and sC5b-9 was lower (effect size 0.11) in the heparin-coated than in the uncoated MiECC, although not significantly different. CONCLUSIONS: Compared with an uncoated MiECC circuit, heparin-coated MiECC circuit was not associated with a reduction in postoperative bleeding, transfusion, inflammation, complement activation, and platelet biomarkers, following isolated coronary artery bypass grafting.
RESUMO
Heart transplantation with donation after circulatory death (DCD) provides excellent patient outcomes and increases donor heart availability. However, unlike conventional grafts obtained through donation after brain death, DCD cardiac grafts are not only exposed to warm, unprotected ischemia, but also to a potentially damaging pre-ischemic phase after withdrawal of life-sustaining therapy (WLST). In this review, we aim to bring together knowledge about changes in cardiac energy metabolism and its regulation that occur in DCD donors during WLST, circulatory arrest, and following the onset of warm ischemia. Acute metabolic, hemodynamic, and biochemical changes in the DCD donor expose hearts to high circulating catecholamines, hypoxia, and warm ischemia, all of which can negatively impact the heart. Further metabolic changes and cellular damage occur with reperfusion. The altered energy substrate availability prior to organ procurement likely plays an important role in graft quality and post-ischemic cardiac recovery. These aspects should, therefore, be considered in clinical protocols, as well as in pre-clinical DCD models. Notably, interventions prior to graft procurement are limited for ethical reasons in DCD donors; thus, it is important to understand these mechanisms to optimize conditions during initial reperfusion in concert with graft evaluation and re-evaluation for the purpose of tailoring and adjusting therapies and ensuring optimal graft quality for transplantation.
Assuntos
Transplante de Coração , Humanos , Transplante de Coração/métodos , Preservação de Órgãos/métodos , Obtenção de Tecidos e Órgãos/métodos , Animais , Perfusão/métodos , Doadores de Tecidos , Metabolismo EnergéticoRESUMO
BACKGROUND: The aim of this study was to report outcomes of all patients undergoing transcatheter mitral valve implantation with the Tendyne Mitral Valve System (Tendyne) in Switzerland. METHODS: We retrospectively analyzed preoperative echocardiographic and computed tomography (CT) data, procedural findings, and 30-day and 1-year follow-up echocardiographic and clinical data of patients who underwent transcatheter mitral valve implantation with Tendyne in Switzerland. RESULTS: A total of 24 patients (age, 74.8 ± 7.8 years; 67% male) underwent transapical transcatheter mitral valve implantation with Tendyne between June 2020 and October 2022. Technical success rate was 96%. In five patients, concomitant interventions in the form of transcatheter aortic valve implantation (one patient), minimally invasive direct coronary artery bypass (one patient), and transcatheter edge-to-edge repair (three patients) were performed prior to or after the index procedure. There was one device embolization, and two patients required valve retrieval. In-hospital outcomes included one stroke and three major bleeding events. None of the patients died within 30 days. Two patients were rehospitalized for decompensated heart failure. At 1-year follow-up, there were three noncardiovascular-related deaths. CONCLUSION: Transcatheter mitral valve implantation with Tendyne is feasible to treat polymorbid patients suffering from complex mitral valve disease as well as patients with previous mitral interventions. Perioperative risk was acceptable and procedural success high.
RESUMO
OBJECTIVES: The Perceval valve was shown to facilitate minimal-invasive operations and shorten operative times. We aimed to compare the early results of the Perceval valve to those of well-established valves, namely the Carpentier-Edwards Perimount and Perimount Magna Ease valve protheses, in terms of their clinical and hemodynamic performances. METHODS: This is a single-center, retrospective, observational cohort study. For every patient operated with a Perceval valve, the last patient before and the next following patient receiving a Perimount valve was included in a control group leading to a 2:1 ratio (Perimount:Perceval). A propensity score matching was used and a subgroup analysis was performed to compare early and late Perceval patients as the sizing technique was changed over time. RESULTS: From November 2013 to November 2017, 423 patients were identified. These included 141 consecutive patients receiving a Perceval valve through a full- or a hemi-sternotomy. In addition, 282 patients receiving a Perimount or a Magna Ease valve were enrolled. After propensity score matching, 127 matched patients were compared. Operating times were shorter and postoperative transvalvular pressure gradients were lower in the Perceval group (15 vs. 17 mmHg, p = 0.002). There was no difference in mortality and stroke rates. The incidence of new pacemaker implantations was higher in the Perceval group (7.1 vs. 18.9%, p = 0.005), mainly due to a very high incidence in the early phase of our Perceval experience prior to a change in the Perceval implantation technique. Subgroup analysis showed significantly better results in the late Perceval group. CONCLUSION: Surgical outcome was good in both groups. The Perceval valve exhibited lower postoperative gradients, and the need for pacemaker implantation was higher and can be reduced by avoiding oversizing.
Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Desenho de PróteseRESUMO
BACKGROUND: We retrospectively evaluated in-hospital and overall outcome of patients who received mitral valve replacement (MVR) after failed MitraClip procedure. METHODS: A total of 26 out of 740 patients received MVR after treatment with MitraClip between June 2010 and December 2020. We analyzed in-hospital mortality and overall mortality during the median follow-up period of 72 days after MVR. RESULTS: The median age in the entire cohort was 77.5 years. In-hospital mortality was 15.4% (n = 4) and the overall mortality during the follow-up period was 27% (n = 7). The median time between the MitraClip procedure and surgery was 34.5 days. The main reasons for surgery were mitral stenosis (23.1%), persistent prolapse of the mitral valve leaflets (42.3%), and persistent tethering of the mitral valve leaflets (34.6%). At the time of surgery all of the patients presented with New York Heart Association 3 and above. The underlying mitral valve pathology was mainly secondary 61.5% (n = 16). Median left ventricular end-diastolic diameter was 60 mm. Preoperative ejection fraction was 40% and above in 73% of the cohort. In addition to the mitral valve procedure, 57.7% of patients received either concomitant tricuspid annuloplasty, aortic valve surgery, ascending aortic replacement, or coronary artery bypass grafting. CONCLUSION: The need for MVR for failed MitraClip repair is low and the results are acceptable. However, remaining options for reconstruction are usually limited and MVR is often needed. Anticipating success or failure according to the underlying pathology more than according to concomitant risk factors should form the basis in decision making for the treatment modality of first choice.
Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Idoso , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estudos Retrospectivos , Resultado do TratamentoRESUMO
Background and Objectives: Patients with chronic total occlusions of the coronary arteries are either treated with PCI or referred for surgical revascularization. We analyzed the patients with chronic occluded coronary arteries that were surgically treated and aimed to describe the anatomical characteristics, revascularization rates, and in-hospital outcomes achieved with coronary artery bypass grafting. Methods: Angiographic data of 2005 patients with coronary artery disease treated in our institution between January 2005 and December 2014 were retrospectively analyzed. A total of 1111 patients with at least one coronary total occlusion were identified. We reviewed the preoperative coronary angiograms and surgical protocols to determine the presence, localization, and revascularization of coronary occlusions. We also evaluated the perioperative data and in-hospital outcomes. Results: The median age of the study population was 68 years (25th-75th percentiles, 61.0-74.0). Three-vessel disease was present in 94.8% of patients and the rest (5.8%) had a two-vessel disease. The localizations of the occlusions were as follows: 68.4% in the RCA system, 26.4% in the LAD, and 28.5% in the LCX system. Multiple occlusions were present in 22.6% of the patients. Complete coronary total occlusion revascularization was achieved in 86.1% of the patients. The overall in-hospital mortality was 2.3%. The median in-hospital stay was 14.0 days. After logistic regression analysis, age (odds ratio 3.44 [95% confidence interval, 1.81-6.53], p < 0.001, for a 10-year increase) and the presence of peripheral artery disease (odds ratio 3.32 [1.39-7.93], p = 0.007) were the only statistically significant independent predictors of in-hospital mortality. Conclusions: A high revascularization rate and favorable in-hospital outcomes are achieved with coronary artery bypass surgery in patients with multi-vessel diseases and coronary total occlusions. Older age and the presence of peripheral artery disease are independent predictors of in-hospital mortality. A long-term follow-up and the type of graft (arterial vs. venous) used would bring more useful data for this type of revascularization.
Assuntos
Doença da Artéria Coronariana , Oclusão Coronária , Intervenção Coronária Percutânea , Doença Arterial Periférica , Humanos , Idoso , Oclusão Coronária/cirurgia , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Resultado do Tratamento , Doença da Artéria Coronariana/cirurgia , Hospitais , Doença Arterial Periférica/etiologia , Fatores de RiscoRESUMO
Background and objectives: The treatment of pathologies of the aortic arch is a complex field of cardiovascular surgery that has witnessed enormous progress recently. Such treatment is mainly performed in high-volume centres, and surgeons gain great experience in mastering potential difficulties even under emergency circumstances, thereby ensuring the effective therapy of more complex pathologies with lower complication rates. As the numbers of patients rise, so does the need for well-trained surgeons in aortic arch surgery. But how is it possible to learn surgical procedures in a responsible way that, in addition to surgical techniques, also places particular demands on the overall surgical management such as perfusion strategy and neuro-protection? This is why a good training programme teaching young surgeons without increasing the risk for patients is indispensable. Our intention was to highlight the most challenging aspects of aortic arch surgery teaching and how young surgeons can master them. Materials and Methods: We analysed the literature to find out which methods are most suitable for such teaching goals and what result they reveal when serving as teaching procedures. Results: Several studies were found comparing the surgical outcome of young trainees with that of specialists. It was found that the results were comparable whether the procedure was performed by a specialist or by a trainee assisted by the specialist. Conclusions: We thus came to the conclusion that even for such a complex type of intervention, the responsible training of young surgeons by experienced specialists is possible. However, it requires a clear strategy and team approach to ensure a safe outcome for the patient.
Assuntos
Aorta Torácica , Cirurgiões , Humanos , Aorta Torácica/cirurgia , Escolaridade , Aprendizagem , IntençãoRESUMO
OBJECTIVE: Mitral regurgitation (MR) and severe aortic valve stenosis often coexist. Concomitant replacement of both valves is associated with a significantly higher morbidity and mortality. This study sought to investigate the progression of MR after isolated aortic valve replacement. METHODS: We analyzed the severity and progression of MR, survival and echocardiographic parameters in 506 patients with severe aortic valve stenosis and moderate to severe functional MR who received isolated aortic valve replacement during a 9-year period. RESULTS: Transcatheter aortic valve implantation (TAVI) was performed in 381 patients and 125 patients received surgical aortic valve replacement (SAVR). The median age of the cohort was 82 years. Median ejection fraction before and after TAVI or SAVR was 35 and 36% respectively (p = 0.64). There was a statistically significant reduction in the MR (p < 0.001) within both groups. Survival in both groups at 5 years was at 25%. CONCLUSION: Isolated aortic valve replacement in patients with accompanying moderate to severe functional MR may present an adequate treatment option for this high-risk patient collective.
Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
BACKGROUND: Invasive coronary angiography (ICA) is essential to detect significant coronary artery disease (CAD) but is generally not recommended in patients with infective aortic valve endocarditis. This study aimed to evaluate the risks and benefits of preoperative ICA in patients before aortic valve replacement. METHODS: Between March 2008 and September 2020, 232 patients were surgically treated for infectious endocarditis of the aortic valve. Sixty-seven (29%) of them underwent preoperative diagnostic ICA and were compared with the patients without preoperative ICA. We collected their baseline characteristics, including the neurological status, previous cardiac surgical procedures, and reviewed the preoperative echocardiograms and the ICA data. The intraoperative data and clinical outcomes after ICA and after surgery were evaluated. RESULTS: ICA revealed a CAD in the majority of our patients (n = 36; 54%): One-vessel disease n = 19 (28%), two-vessel disease n = 6 (9%), and three-vessel disease n = 11 (16%). We observed no adverse events following preoperative diagnostic ICA, particularly no thromboembolic complications, including stroke, visceral, or lower body ischemia were detected. During surgical aortic valve replacement, concomitant coronary artery bypass grafting was performed in 20 patients (30%). In patients with preoperative ICA, postoperative in-hospital mortality was significantly lower (n = 8 [12%] vs. n = 30 [18%]; p < 0.001), while the incidence of postoperative bleeding was higher (n = 18 [27%] vs. n = 22 [13%]; p = 0.022). The new-onset stroke incidence was 5% in each group. CONCLUSION: Taking a multidisciplinary team approach, ICA is safe in selected patients with aortic valve infectious endocarditis with no adverse clinical outcomes, but significant clinical implications.
RESUMO
OBJECTIVES: The aim of this study was to compare aortic diameters from admission computed tomography angiography (CTA) scans to postoperative aortic diameters in patients with traumatic aortic injury (TAI) and evaluate the influence of substantial blood loss on aortic diameter. METHODS: The aortic databases of two tertiary university centers were retrospectively screened for patients with TAI between February 2002 and February 2019. Concomitant organ injuries, bone fractures, blood loss, and clinical outcomes were evaluated. Aortic diameters were measured in CTA upon admission and were compared with the CTA before discharge at three different aortic levels (mid-ascending, 5 cm distal to the end of the stent graft, and at the celiac trunk level). RESULTS: We identified 45 patients, aged 43 (first quartile; third quartile [26; 55]) years with a TAI treated by thoracic endovascular aortic repair. The most frequent cause of TAI was a car accident (n = 24). Concomitant injuries were seen in all but one patient. Bone and pelvic fractures were seen in 40 (89%) and 15 (33%) patients, respectively. Type III aortic injury was present in 25 patients (56%). Increase of aortic diameter after stabilization was +1.7 mm (-0.6 mm; 2.5 mm; p = 0.004) at the mid-ascending aorta, +2.1 mm (0.2 mm; 3.8 mm; p < 0.001) 5 cm distal to the stent graft, and +1.5 mm (0.5 mm; 3.2 mm; p < 0.001) at the celiac trunk level. CONCLUSION: In patients with TAI, the aortic diameter is significantly reduced as compared with the aortic diameter at discharge. The reduction of aortic diameter might be caused by hemorrhagic shock and should be kept in mind for appropriate stent-graft sizing.
Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Lesões do Sistema Vascular , Aorta/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/lesões , Aorta Torácica/cirurgia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Humanos , Estudos Retrospectivos , Stents , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/cirurgiaRESUMO
BACKGROUND: Aim of this study was to report on indications and clinical outcomes of patients who underwent subsequent open-cardiac surgery after transcatheter aortic valve implantation TAVI. METHODS: Between 01/2011 and 12/2020 our centre performed 4043 TAVI procedures. Twenty-seven patients (including patients in whom TAVI was performed in other centres) underwent subsequent open-heart surgery via cardiopulmonary bypass. Demographic, intraprocedural data, indications for, and outcomes after surgery were evaluated. RESULTS: Indications for cardiac surgery (aged 79 [IQR 76-84]; 59.3% male) were endocarditis (n = 11; 40.7%), annular rupture, severe paravalvular leak and severe stenosis in three (11.1%) patients, respectively as well as in one patient each (3.7%) severe tricuspid valve regurgitation, valve thrombosis, valve malposition, valve migration, ostial right coronary artery obstruction, left ventricular rupture and type A aortic dissection. The interval between the index TAVI procedure to open surgery was 3 months (IQR 0-26 months). Eight patients underwent emergent surgical conversions. Immediate procedural and procedural mortality was 25.9% and 40.7%, respectively and all-cause mortality was 51.9% (11/12 died for cardiovascular reasons). No disabling stroke was observed postoperatively. New permanent pacemaker implantation was required in three patients (11.1%). CONCLUSIONS: Subsequent open-cardiac surgery after TAVI is rare, but may urgently become necessary due to TAVI related complications or progressing other cardiac pathologies. Despite a substantial early attrition rate clinical outcome is acceptable and a relevant number of these high-risk patients can be discharged even after emergency conversions. The option of subsequent surgical conversion remains.
Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Valva Aórtica/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Estenose da Valva Aórtica/etiologia , Implante de Prótese de Valva Cardíaca/métodos , Fatores de RiscoRESUMO
PURPOSE OF REVIEW: Since the advent of the Fontan palliation, survival of patients with univentricular congenital heart disease has increased significantly. These patients will, however, ultimately develop heart failure requiring advanced therapies such as heart transplantation. As wait times are long, mechanical circulatory support (MCS) is an attractive therapy, both for bridge to transplantation and destination therapy in patients not suitable for transplantation. This review aims to summarize current thinking about how to determine which patients would benefit from a ventricular assist device (VAD), the optimal time for implantation and which device should be considered. RECENT FINDINGS: VAD implantation in end-stage Fontan is still in its infancy; however, case reports and research interest have increased extensively in the past few years. Mortality is significantly higher than in noncongenital heart disease patients. Implantation in patients with primarily systolic dysfunction is indicated, whereas patients with increased transpulmonary gradient may not benefit from a single-VAD solution. When possible, implantation should occur prior to clinical decompensation with evidence of end-organ damage, as outcomes at this point are worse. SUMMARY: Fontan patients demonstrating signs of heart failure should be evaluated early and often for feasibility and optimal timing of VAD implantation. The frequency of this procedure will likely increase significantly in the future.
Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/cirurgia , Insuficiência Cardíaca/cirurgia , Humanos , Resultado do TratamentoRESUMO
OBJECTIVE: To evaluate outcomes of patients with acute complicated or chronic Type B or non-A non-B aortic dissection who underwent the frozen elephant trunk (FET) technique. METHODS: Between April 2013 and July 2019, 41 patients presenting with acute complicated (n = 29) or chronic (n = 12) descending thoracic aortic dissection were treated by the FET technique, which was the treatment of choice when supra-aortic vessel transposition would not suffice to create a satisfactory proximal landing zone for endovascular aortic repair, when a concomitant ascending or arch aneurysm was present, or in patients with connective tissue diseases. RESULTS: One patient (2%) died intra-operatively secondary to an aortic rupture in dwnstream aortic segments. No post-operative deaths occurred. Four patients (10%) suffered a non-disabling posto-operative stroke and were discharged with no clinical symptoms (modified Rankin Scale [mRS] 0, n = 1), no significant disability (mRS 1, n = 2), or with slight disability (mRS 2, n = 1). No spinal cord ischaemia was observed. The primary entry tear was either surgically resected or excluded from circulation in all patients. During follow up, one patient (2%) died after two years (not aorta related) and 16 patients (39%) underwent an aortic re-intervention after 7.7 [interquartile range 0.7, 15.8] months (endovascular aortic repair: n = 14; open thoraco-abdominal aortic replacement: n = 1, hybrid approach: n = 1). CONCLUSION: The FET technique is an effective treatment option for acute complicated and chronic Type B or non-A non-B aortic dissection in patients in whom primary endovascular aortic repair is non-feasible. While the post-operative outcome is acceptable with a relatively low incidence of non-disabling strokes, this study also underlines the considerable need for aortic re-interventions. Continuous follow up of all patients undergoing the FET procedure is essential.
Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Idoso , Dissecção Aórtica/mortalidade , Dissecção Aórtica/patologia , Aorta Torácica/patologia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/patologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Reoperação/estatística & dados numéricos , Análise de Sobrevida , Enxerto Vascular/métodosRESUMO
BACKGROUND: We retrospectively evaluated vascular complications and wound infections after surgical or percutaneous transfemoral removal of temporary extracorporeal life support systems (ECLSs). METHODS: A total of 83 patients were weaned from ECLS between August 2015 and September 2020. We analyzed for a composite endpoint of vascular complications and wound infections requiring negative-pressure wound therapy. Patients were divided into two groups: percutaneous group using the MANTA vascular occlusion system (VCD; Teleflex, Morrisville, North Carolina, United States) (n = 23) and surgical group (n = 60). RESULTS: The median age in the entire cohort was 67 years. Vascular complications were seen in 20% (n = 12) in the surgical group and in 13% (n = 3) in the percutaneous group (p = 0.72). A total of 32% (n = 19) in the surgical group and 9% (n = 2) in the percutaneous group (p = 0.031) had wound infections. A composite endpoint of vascular complications and wound infections showed significantly more complications in the surgical group (52%, n = 31) as compared with the percutaneous group (22%, n = 5) (p = 0.020). The median duration in the intensive care unit was 13 days for the surgical group and 12 days for the percutaneous group without any significant difference in both groups (p = 0.93). CONCLUSIONS: Using the MANTA VCD for percutaneous removal of ECLS cannulas after weaning from ECLS is safe and reproducible. A composite endpoint of vascular complications and wound infections was significantly lower in the percutaneous removal group as compared with the surgical group.
Assuntos
Artérias , Cateterismo Periférico , Hemorragia/prevenção & controle , Técnicas Hemostáticas/instrumentação , Dispositivos de Oclusão Vascular , Idoso , Cateterismo Periférico/efeitos adversos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Feminino , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Tratamento de Ferimentos com Pressão Negativa , Punções , Estudos Retrospectivos , Fatores de Risco , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/terapia , Fatores de Tempo , Resultado do TratamentoRESUMO
INTRODUCTION: Spinal cord ischemia after cardiovascular interventions continues to be a devastating problem in modern surgery. The role of intraspinal vascular networks and anterior radiculomedullary arteries (ARMA) in preventing spinal cord ischemia is poorly understood. MATERIALS AND METHODS: Landrace pigs (n = 30, 35.1 ± 3.9 kg) underwent a lateral thoracotomy. Fluorescent microspheres were injected into the left atrium and a reference sample was aspirated from the descending aorta. Repeated measurements of spinal cord and renal cortical blood flow from the left and right kidneys with three different microsphere colors in five pigs were taken to validate reproducibility. Spinal cord blood flow to the upper thoracic (T1-T4), mid-thoracic (T5-T8), lower thoracic (T9-T13), and lumbar (L1-L3) levels were determined. After euthanasia, we carried out selective vascular corrosion cast and counted the left and right ARMAs from levels T1-T13. RESULTS: Blood flow analysis of the left and right kidneys revealed a strong correlation (r = .94, p < .001). We detected more left than right ARMAs, with the highest prevalence at T4 (p < .05). The mean number of ARMAs was 8 ± 2. Their number in the upper thoracic region ranged from 2 to 7 (mean of 5 ± 1), while in the lower thoracic region they ranged from 0 to 5 (mean of 3 ± 1 [p < .001]). CONCLUSIONS: This study shows that combining fluorescence microsphere technique and vascular corrosion cast is well suited for assessing the blood flow and visualizing the arteries at the same time.
Assuntos
Aorta Torácica/cirurgia , Circulação Colateral/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Isquemia do Cordão Espinal/prevenção & controle , Medula Espinal/irrigação sanguínea , Animais , Molde por Corrosão , Estudos de Viabilidade , Fluorescência , Microesferas , Modelos Animais , SuínosRESUMO
OBJECTIVES: Aim of this study was to evaluate feasibility and benefit of self-designed, radiopaque markers as a novel technique in neonates and infants with shunt- or duct-dependent lesions. BACKGROUND: Surgically placed radiopaque markers have the potential to facilitate postoperative percutaneous interventions. METHODS: All consecutive children with surgically placed radiopaque markers involving systemic-to-pulmonary artery connections or arterial ducts in the context of hybrid palliation and subsequent cardiac catheterization between January 2013 and March 2019 were included in this analysis. Our primary endpoint was our concept's feasibility, which we defined as a combination of surgical feasibility and the percutaneous intervention's success. Secondary endpoint was the rate of complications resulting from the surgical procedure or during catheterization. RESULTS: Radiopaque markers that reveal the proximal entry of a surgical shunt or the arterial duct proved to be a feasible and beneficial approach in 25 postoperative catheterizations. The markers' high accuracy enabled easy probing and proper stent positioning in 13 neonates with a median age and weight of 121 days (range 9-356) and 4.7 kg (1.6-9.4) at the intervention. No procedural complications or unanticipated events associated with the radiopaque marker occurred. The markers were never lost, never migrated, and caused no local obstructive lesion. Surgical removal was straightforward in all patients. CONCLUSIONS: Radiopaque markers are a promising and refined technique to substantially facilitate target vessel access and enabling the accurate positioning of stents during postoperative percutaneous procedures.