Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
An Acad Bras Cienc ; 96(suppl 1): e20230356, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39016355

RESUMO

Using Amazonian fruits to flavor kombuchas is a promising proposal, as it adds nutritional value to the drink. This work sought to develop kombucha flavored with Amazonian fruits and evaluate the bioactive compounds and antioxidant capacity of the formulations. Three kombucha formulations were prepared using green tea (Camellia sinensis) and three Amazonian fruits: cupuassu (Theobroma grandiflorum), tapereba (Spondias lutea L.) and bacuri (Platonia insignis). Kombucha fermentations were evaluated before and after the insertion of nectars through the analysis of phenolic compounds, vitamin C and antioxidant capacity. Analyzes of pH, total sugars, acetic acid, ethanol, and microbiological characterization of final formulations were also carried out. For the first fermentation, were found values of phenolic compounds and antioxidant capacity of 30.60 ± 0.93 mg EAG/L and 295.02 ± 5.59 µmol ET/mL, and the formulation with tapereba showed the highest values for total phenolic compounds (34.92 ± 12.25 mg EAG/L), antioxidant capacity (320.57 ± 9.53 µmol ET/mL) and vitamin C (198.25 mg/100g). Thus, the formulations developed had a crucial nutritional appeal to stimulate consumption by the population, in addition to enabling the valorization and addition of commercial value to the Amazonian fruits used.


Assuntos
Antioxidantes , Frutas , Fenóis , Antioxidantes/análise , Frutas/química , Fenóis/análise , Ácido Ascórbico/análise , Fermentação , Chá de Kombucha/análise
2.
Sensors (Basel) ; 23(4)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36850872

RESUMO

Currently, few experimental methods exist that enable the mechanical characterization of adhesives under high strain rates. One such method is the Split Hopkinson Bar (SHB) test. The mechanical characterization of adhesives is performed using different specimen configurations, such as Single Lap Joint (SLJ) specimens. A gripping system, attached to the bars through threading, was conceived to enable the testing of SLJs. An optimization study for selecting the best thread was performed, analyzing the thread type, the nominal diameter, and the thread pitch. Afterwards, the gripping system geometry was numerically evaluated. The optimal threaded connection for the specimen consists of a trapezoidal thread with a 14 mm diameter and a 2 mm thread pitch. To validate the gripping system, the load-displacement (P-δ) curve of an SLJ, which was simulated as if it were tested on the SHB apparatus, was compared with an analogous curve from a validated drop-weight test numerical model.

3.
J Prosthet Dent ; 2022 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-36543700

RESUMO

STATEMENT OF PROBLEM: Computer-aided design and computer-aided manufacturing (CAD-CAM) blocks have evolved rapidly, making it difficult to establish the best clinical protocol for bonding a given block and whether an established protocol is appropriate for a newly introduced product. PURPOSE: This integrative systematic review and meta-analysis aimed to clarify whether the clinician can select the most efficient adhesion protocols for CAD-CAM blocks by reading published in vitro studies and implementing them in daily practice. MATERIAL AND METHODS: Based on the population, intervention, comparison, and outcome (PICO) strategy, 3 databases were searched for in vitro studies, randomized clinical trials, prospective or retrospective studies, and case reports from January 1, 2015, to July 31, 2021. A meta-analysis analyzed 28 studies to calculate the mean difference between best and worst protocols for each author and block with a random-effects model (α=.05). RESULTS: From 508 relevant studies, 37 in vitro studies, 2 clinical studies, and 1 clinical report were selected for data extraction and qualitative analysis. Vita Enamic, IPS e.max CAD, LAVA Ultimate, and Vita Mark II blocks were the most studied, and RelyX Ultimate was the most used luting cement. The meta-analysis confirmed the null hypothesis that the evidence-based efficacy of clinical protocols to bond CAD-CAM blocks is still controversial (P<.05). CONCLUSIONS: There are objective standards for individual in vitro tests, but the studies lack standardization. Some tested protocols were more efficient than others. Randomized clinical trials and well-documented clinical situations were almost nonexistent, making direct application of in vitro findings in clinical practice impossible.

4.
Microsc Microanal ; 25(1): 187-191, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30231947

RESUMO

The influence of the concentration of carbon black nanoparticles on the mechanical behavior of a structural adhesive was studied to evaluate and understand the stiffness, strength, and deformation behavior of a reinforced epoxy adhesive. Two carbon black nanoparticles with different dielectric properties and sizes (Monarch® 120 and Vulcan® XC72R) were studied. A bi-component structural epoxy adhesive was selected. Specimens with different concentrations of carbon black were manufactured (0, 5, 10, and 20% on volume of resin) for each type of nanoparticle. The specimens were cured in a hydraulic hot-plates press machine. The mechanical behavior of the adhesives was found not to vary significantly as a function of carbon black nanoparticles amount. A scanning electron microscopy analysis was performed to evaluate the fracture surface. The fracture surfaces of specimens were correlated with the mechanical response obtained through tensile tests.

6.
Eur J Dent ; 18(3): 796-807, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38158209

RESUMO

OBJECTIVES: Maxillary lateral incisor agenesis (MLIA), treated orthodontically by space opening, requires complimentary aesthetic rehabilitation. Resin-bonded bridges (RBBs) can be equated as interim rehabilitation until skeletal maturity is achieved to place an implant-supported crown or as definitive rehabilitation in case of financial restrictions or implant contraindications. Scientific evidence of the best material must be confirmed in specific clinical situations. Computer-aided design and computer-aided manufacturing (CAD/CAM) materials are promising versatile restorative options. This study aimed to identify a straightforward material to deliver interim or definitive RBBs for nonprepared tooth replacement in MLIA. MATERIALS AND METHODS: Single-retainer RBB made from CAD/CAM ceramic blocks (Vita Enamic [ENA], Suprinity [SUP], and zirconia [Y-ZPT]) and a three-dimensional (3D) printed material (acrylonitrile butadiene styrene [ABS]) were evaluated by shear bond strength (SBS) and mode of failure, after adherence to an artificial tooth with RelyX Ultimate used in a three-step adhesive strategy. STATISTICAL ANALYSIS: The load to fracture (N) was recorded, and the mean shear stress (MPa) was calculated with standard deviations (SD) for each group and compared between materials using boxplot graphics. One-way analysis of variance (ANOVA) followed by the Tukey-Kramer post hoc test was used to compare the differences (α = 0.05). A meta-analysis focusing on CAD/CAM materials evaluated the magnitude of the difference between groups based on differences in means and effect sizes (α = 0.05; 95% confidence interval [CI]; Z-value = 1.96). Failure mode was determined by microscopic observation and correlated with the maximum load to fracture of the specimen. RESULTS: The mean ± SD SBS values were ENA (24.24 ± 9.05 MPa) < ABS (24.01 ± 1.94 MPa) < SUP (29.17 ± 4.78 MPa) < Y-ZPT (37.43 ± 12.20 MPa). The failure modes were mainly adhesive for Y-ZPT, cohesive for SUP and ENA, and cohesive with plastic deformation for ABS. CONCLUSION: Vita Enamic, Suprinity, Y-ZPT zirconia, and 3D-printed ABS RBBs are optional materials for rehabilitating MLIA. The option for each material is conditioned to estimate the time of use and necessity of removal for orthodontic or surgical techniques.

7.
Materials (Basel) ; 17(10)2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38793454

RESUMO

The use of thin-ply composite materials has rapidly increased due to their tailorable mechanical properties and design flexibility. Considering an adhesively bonded composite joint, peel stress stands out as a key contributor leading to failure among other primary stress factors. Therefore, the reinforcement of carbon fiber-reinforced polymer (CFRP) laminates throughout the thickness could be considered as an approach to improve the joint strength. Using thin plies locally between the conventional CFRP layers in a laminate can enhance the strength, as the sudden change in stiffness means that the load transfer is not monotonous. Consequently, the following study examined the effect of altering thin plies gradually throughout the thickness on the behaviour of the CFRP laminates when subjected to transverse tensile loading. To achieve this goal, the CFRP laminates were gradually modified by using different commercially accessible prepreg thin plies, leading to an improved overall structural performance by reducing stress concentrations. Besides conducting an experimental study, a numerical assessment was also carried out utilizing Abaqus software with a Representative Volume Element (RVE) at the micro scale. The comparison of reference configurations, which involved various thin plies with different thicknesses and traditional CFRP laminates, with the suggested gradual configuration, demonstrated a notable enhancement in both strength and material cost. Furthermore, the proposed RVE model showed promising capability in accurately forecasting the strength of fabricated laminates.

8.
Polymers (Basel) ; 16(16)2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39204504

RESUMO

While most academic studies focus on the properties of cured joints, this research addresses the manufacturing process of hybrid joints in their uncured state. Hybrid joints that combine adhesive bonding with pre-tensioned bolts exhibit superior mechanical performance compared to exclusively bonded or bolted joints. However, the adhesive flow during manufacturing in hybrid joints often results in a nonuniform adhesive thickness, where obtaining an exact thickness is crucial for accurate load capacity predictions. This paper presents experiments involving three different adhesives, providing precise measurements of the adhesive layer thickness distribution, which served as a reference when evaluating and validating the subsequent numerical predictions. The numerical predictions were performed using computational fluid dynamics (CFD) to model the flow behavior of the adhesives during the bonding process and their interactions with the metal substrates. The CFD predictions of the adhesive layer thickness showed good agreement with the experimental data, with the relative differences between the average experimental and numerical thickness values ranging from 4.07% to 27.1%. The results were most accurate for the adhesive with sand particles, whose particles remained intact, ensuring that the adhesive's rheology remained unchanged. The results highlight the importance of the rheological behavior of the adhesive in the final distribution of the adhesive layer thickness, thereby expanding the understanding of these joints.

9.
Polymers (Basel) ; 16(16)2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39204602

RESUMO

This study focuses on the prediction of the fracture mechanics behaviour of a highly flexible adhesive (with a tensile elongation of 90%), since this type of adhesive is becoming widely used in automotive structures due to their high elongation at break and damping capacity. Despite their extensive applications, the understanding of their fracture mechanics behaviour under varying loading rates and temperatures remains limited in the literature. In addition, current prediction models are also unable to accurately predict their behaviour due to the complex failure mechanism that such bonded joints have. This study aims to determine whether a simple triangular cohesive zone model (CZM), which predefines the crack path, can reproduce the load-displacement curves of adhesives under various temperatures and strain rates. To achieve this, a calibrated CZM is used, adapting the model for reference joints and then validating it with independent test results conducted in a wide range of loading and environmental conditions. The tests were performed at speeds between 0.2 and 6000 mm/min and at three different temperatures ranging from -30 °C to 60 °C. Mode I fracture toughness was measured using the DCB (double cantilever beam) specimens. Using a simple triangular CZM may not be optimal for predicting the mechanical response of highly flexible adhesives with complex failure mechanisms and multiple crack paths. However, by correctly adjusting the cohesive zone properties for a limited set of reference conditions, it is possible to accurately predict the mechanical response of these joints across various test speeds and temperatures, significantly reducing costs and effort.

10.
Polymers (Basel) ; 16(4)2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38399841

RESUMO

Semiconductor advancements demand greater integrated circuit density, structural miniaturization, and complex material combinations, resulting in stress concentrations from property mismatches. This study investigates the failure in two types of interfaces found in chip packages: silicon-epoxy mold compound (EMC) and polyimide-EMC. These interfaces were subjected to quasi-static and fatigue loading conditions. Employing a compliance-based beam method, the tests determined interfacial critical fracture energy values, (GIC), of 0.051 N/mm and 0.037 N/mm for the silicon-EMC and polyimide-EMC interfaces, respectively. Fatigue testing on the polyimide-epoxy interface revealed a fatigue threshold strain energy, (Gth), of 0.042 N/mm. We also observed diverse failure modes and discuss potential mechanical failures in multi-layer chip packages. The findings of this study can contribute to the prediction and mitigation of failure modes in the analyzed chip packaging. The obtained threshold energy and crack growth rate provide insights for designing safe lives for bi-material interfaces in chip packaging under cyclic loads. These insights can guide future research directions, emphasizing the improvement of material properties and exploration of the influence of manufacturing parameters on delamination in multilayer semiconductors.

11.
Materials (Basel) ; 17(9)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38730902

RESUMO

This study experimentally investigates the influence of metal chips and glass fibers on the mode I fracture toughness, energy absorption, and tensile strength of polymer concretes (PCs) manufactured by waste aggregates. A substantial portion of the materials employed in manufacturing and enhancing the tested polymer concrete are sourced from waste material. To achieve this, semi-circular bend (SCB) samples were fabricated, both with and without a central crack, to analyze the strength and fracture behavior of the composite specimens. The specimens incorporated varying weight percentages comprising 50 wt% coarse mineral aggregate, 25 wt% fine mineral aggregate, and 25 wt% epoxy resin. Metal chips and glass fibers were introduced at 2, 4, and 8 wt% of the PC material to enhance its mechanical response. Subsequently, the specimens underwent 3-point bending tests to obtain tensile strength, mode I fracture toughness, and energy absorption up to failure. The findings revealed that adding 4% brass chips along with 4% glass fibers significantly enhanced energy absorption (by a factor of 3.8). However, using 4% glass fibers alone improved it even more (by a factor of 10.5). According to the results, glass fibers have a greater impact than brass chips. Introducing 8% glass fibers enhanced the fracture energy by 92%. However, in unfilled samples, aggregate fracture and separation hindered crack propagation, and filled samples presented added barriers, resulting in multiple-site cracking.

12.
Materials (Basel) ; 17(5)2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38473521

RESUMO

Adhesive bonding has been increasingly employed in multiple industrial applications. This has led to a large industrial demand for faster, simpler, and cheaper characterization methods that allow engineers to predict the mechanical behavior of an adhesive with numerical models. Currently, these characterization processes feature a wide variety of distinct standards, specimen configurations, and testing procedures and require deep knowhow of complex data-reduction schemes. By suggesting the creation of a new and integrated experimental tool for adhesive characterization, it becomes possible to address this problem in a faster and unified manner. In this work, following a previous numerical study, the mode I and II components of fracture-toughness characterization were validated experimentally in two different configurations, Balanced and Unbalanced. For mode I, it was demonstrated that both configurations presented similar numerical and experimental R-curves. The relative error against standard tests was lower than ±5% for the Balanced specimen; the Unbalanced system showed higher variations, which were predicted by the numerical results. Under mode II, the Balanced specimen displayed plastic deformation due to high deflections. On the contrary, the Unbalanced specimen did not show this effect and presented a relative error of approximately ±2%. Nonetheless, it was proven that this approach to obtain such data by using a single unified specimen is still feasible but needs further development to obtain with similar precision of standard tests. In the end, a conceptual change is proposed to solve the current mode II issues.

13.
Materials (Basel) ; 17(2)2024 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-38255456

RESUMO

Examining crack propagation at the interface of bimaterial components under various conditions is essential for improving the reliability of semiconductor designs. However, the fracture behavior of bimaterial interfaces has been relatively underexplored in the literature, particularly in terms of numerical predictions. Numerical simulations offer vital insights into the evolution of interfacial damage and stress distribution in wafers, showcasing their dependence on material properties. The lack of knowledge about specific interfaces poses a significant obstacle to the development of new products and necessitates active remediation for further progress. The objective of this paper is twofold: firstly, to experimentally investigate the behavior of bimaterial interfaces commonly found in semiconductors under quasi-static loading conditions, and secondly, to determine their respective interfacial cohesive properties using an inverse cohesive zone modeling approach. For this purpose, double cantilever beam specimens were manufactured that allow Mode I static fracture analysis of the interfaces. A compliance-based method was used to obtain the crack size during the tests and the Mode I energy release rate (GIc). Experimental results were utilized to simulate the behavior of different interfaces under specific test conditions in Abaqus. The simulation aimed to extract the interfacial cohesive contact properties of the studied bimaterial interfaces. These properties enable designers to predict the strength of the interfaces, particularly under Mode I loading conditions. To this extent, the cohesive zone modeling (CZM) assisted in defining the behavior of the damage propagation through the bimaterial interfaces. As a result, for the silicon-epoxy molding compound (EMC) interface, the results for maximum strength and GIc are, respectively, 26 MPa and 0.05 N/mm. The second interface tested consisted of polyimide and silicon oxide between the silicon and EMC layers, and the results obtained are 21.5 MPa for the maximum tensile strength and 0.02 N/mm for GIc. This study's findings aid in predicting and mitigating failure modes in the studied chip packaging. The insights offer directions for future research, focusing on enhancing material properties and exploring the impact of manufacturing parameters and temperature conditions on delamination in multilayer semiconductors.

14.
Polymers (Basel) ; 16(17)2024 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-39274178

RESUMO

In response to heightened environmental awareness, various industries, including the civil and automotive sector, are contemplating a shift towards the utilization of more sustainable materials. For adhesive bonding, this necessitates the exploration of materials derived from renewable sources, commonly denoted as bio-adhesives. This study focuses on a bio-adhesive L-joint, which is a commonly employed configuration in the automotive sector for creating bonded structural components with significant bending stiffness. In this investigation, the behavior of joints composed of pine wood and bio-based adhesives was studied. Two distinct configurations were studied, differing solely in the fiber orientation of the wood. The research combined experimental testing and finite element modeling to analyze the strength of the joints and determine their failure mode when subjected to tensile loading conditions. The findings indicate that the configuration of the joint plays a crucial role in its overall performance, with one of the solutions demonstrating higher strength. Additionally, a good degree of agreement was observed between the experimental and numerical analyses for one of the configurations, while the consideration of the maximum principal stress failure predictor (MPSFP) proved to accurately predict the location for crack propagation in both configurations.

15.
Appl Microbiol Biotechnol ; 97(5): 2093-107, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22915193

RESUMO

High hydrostatic pressure (HHP) is a stress that exerts broad effects on microorganisms with characteristics similar to those of common environmental stresses. In this study, we aimed to identify genetic mechanisms that can enhance alcoholic fermentation of wild Saccharomyces cerevisiae isolated from Brazilian spirit fermentation vats. Accordingly, we performed a time course microarray analysis on a S. cerevisiae strain submitted to mild sublethal pressure treatment of 50 MPa for 30 min at room temperature, followed by incubation for 5, 10 and 15 min without pressure treatment. The obtained transcriptional profiles demonstrate the importance of post-pressurisation period on the activation of several genes related to cell recovery and stress tolerance. Based on these results, we over-expressed genes strongly induced by HHP in the same wild yeast strain and identified genes, particularly SYM1, whose over-expression results in enhanced ethanol production and stress tolerance upon fermentation. The present study validates the use of HHP as a biotechnological tool for the fermentative industries.


Assuntos
Etanol/metabolismo , Expressão Gênica , Pressão Hidrostática , Saccharomyces cerevisiae/fisiologia , Estresse Fisiológico , Brasil , Perfilação da Expressão Gênica , Redes e Vias Metabólicas/genética , Análise em Microsséries , Saccharomyces cerevisiae/metabolismo , Fatores de Tempo
16.
Materials (Basel) ; 16(11)2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37297137

RESUMO

It has been demonstrated that a possible solution to reducing delamination in a unidirectional composite laminate lies in the replacement of conventional carbon-fibre-reinforced polymer layers with optimized thin-ply layers, thus creating hybrid laminates. This leads to an increase in the transverse tensile strength of the hybrid composite laminate. This study investigates the performance of a hybrid composite laminate reinforced by thin plies used as adherends in bonded single lap joints. Two different composites with the commercial references Texipreg HS 160 T700 and NTPT-TP415 were used as the conventional composite and thin-ply material, respectively. Three configurations were considered in this study: two reference single lap joints with a conventional composite or thin ply used as the adherends and a hybrid single lap. The joints were quasi-statically loaded and recorded with a high-speed camera, allowing for the determination of damage initiation sites. Numerical models of the joints were also created, allowing for a better understanding of the underlying failure mechanisms and the identification of the damage initiation sites. The results show a significant increase in tensile strength for the hybrid joints compared to the conventional ones as a result of changes in the damage initiation sites and the level of delamination present in the joint.

17.
Materials (Basel) ; 16(8)2023 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-37109832

RESUMO

Self-adhesive resin cements (SARCs) are used because of their mechanical properties, ease of cementation protocols, and lack of requirements for acid conditioning or adhesive systems. SARCs are generally dual-cured, photoactivated, and self-cured, with a slight increase in acidic pH, allowing self-adhesiveness and increasing resistance to hydrolysis. This systematic review assessed the adhesive strength of SARC systems luted to different substrates and computer-aided design and manufacturing (CAD/CAM) ceramic blocks. The PubMed/MedLine and Science Direct databases were searched using the Boolean formula [((dental or tooth) AND (self-adhesive) AND (luting or cement) AND CAD-CAM) NOT (endodontics or implants)]. Of the 199 articles obtained, 31 were selected for the quality assessment. Lava Ultimate (resin matrix filled with nanoceramic) and Vita Enamic (polymer-infiltrated ceramic) blocks were the most tested. Rely X Unicem 2 was the most tested resin cement, followed by Rely X Unicem > Ultimate > U200, and µTBS was the test most used. The meta-analysis confirmed the substrate-dependent adhesive strength of SARCs, with significant differences between them and between SARCs and conventional resin-based adhesive cement (α < 0.05). SARCs are promising. However, one must be aware of the differences in the adhesive strengths. An appropriate combination of materials must be considered to improve the durability and stability of restorations.

18.
Materials (Basel) ; 16(24)2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38138831

RESUMO

This study investigates the mixed-mode I/II fracture behavior of O-notched diagonally loaded square plate (DLSP) samples containing an edge crack within the O-notch. This investigation aims to explore the combined effects of loading rate and mode mixity on the fracture properties of steel 304L, utilizing DLSP samples. The DLSP samples, made from strain-hardening steel 304L, were tested at three different loading rates: 1, 50, and 400 mm/min, covering five mode mixities from pure mode I to pure mode II. Additionally, tensile tests were performed on dumbbell-shaped specimens at the same loading rates to examine their influence on the material's mechanical properties. The findings revealed that stress and strain diagrams derived from the dumbbell-shaped samples were largely independent of the tested loading rates (i.e., 1-400 mm/min). Furthermore, experimental results from DLSP samples showed no significant impact of the loading rates on the maximum load values, but did indicate an increase in the ultimate displacement. In contrast to the loading rate, mode mixity exhibited a notable effect on the fracture behavior of DLSP samples. Ultimately, it was observed that the loading rate had an insignificant effect on the fracture path or trajectory of the tested DLSP samples.

19.
Materials (Basel) ; 16(23)2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-38068043

RESUMO

The need for more sustainable adhesive formulations has led to the use of silane-based adhesives in different industrial sectors, such as the automotive industry. In this work, the mechanical properties of a dual cure two-component prototype adhesive which combined silylated polyurethane resin (SPUR) with standard epoxy resin was characterized under quasi-static conditions. The characterization process consisted of tensile bulk testing, to determine the Young's modulus, the tensile strength and the tensile strain to failure. The shear stiffness and shear strength were measured by performing a thick adherend shear test. The in-plane strain field was obtained using a digital image correlation method. Double-cantilever beam and mixed-mode tests were performed to assess the fracture toughness under pure modes. The prototype adhesive showed promising but lower properties compared to commercial solutions. Furthermore, the adhesive was modified via the addition of three different resin modifier additives and characterized via measuring the shear and tensile properties, but no enhancements were found. Finally, the adhesive was formulated with three different SPUR viscosities. The critical energy release rate analysis showed an optimum value for the medium viscosity SPUR adhesive.

20.
Materials (Basel) ; 16(23)2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38068243

RESUMO

The use of adhesive bonding in diverse industries such as the automotive and aerospace sectors has grown considerably. In structural construction, adhesive joints provide a unique combination of low structural weight, high strength and stiffness, combined with a relatively simple and easily automated manufacturing method, characteristics that are ideal for the development of modern and highly efficient vehicles. In these applications, ensuring that the failure mode of a bonded joint is cohesive rather than adhesive is important since this failure mode is more controlled and easier to model and to predict. This work presents a numerical technique that enables the precise prediction of the bonded joint's behavior regarding not only its failure mode, but also the joint's strength, when inorganic fillers are added to the adhesive. To that end, hollow glass particles were introduced into an epoxy adhesive in different amounts, and a numerical study was carried out to simulate their influence on single lap joint specimens. The numerical results were compared against experimental ones, not only in terms of joint strength, but also their failure pattern. The neat adhesive, which showed 9% and 20% variations in terms of failure load and displacement, respectively. However, looking at the doped configurations, these presented smaller variations of about 2% and 10% for each respective variable. In all cases, by adding glass beads, crack initiation tended to change from adhesive to cohesive but with lower strength and ductility, correctly modeling the general experimental behavior as intended.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA