1.
Am J Hematol ; 96(8): 968-978, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33971046

RESUMO

During cardiac surgery with cardiopulmonary bypass (CPB), altered hemostatic balance may disrupt fibrin assembly, predisposing patients to perioperative hemorrhage. We investigated the utility of a novel device termed spectrally-encoded confocal microscopy (SECM) for assessing fibrin clot polymerization following heparin and protamine administration in CPB patients. SECM is a novel, high-speed optical approach to visualize and quantify fibrin clot formation in three dimensions with high spatial resolution (1.0 µm) over a volumetric field-of-view (165 × 4000 × 36 µm). The measurement sensitivity of SECM was first determined using plasma samples from normal subjects spiked with heparin and protamine. Next, SECM was performed in plasma samples from patients on CPB to quantify the extent to which fibrin clot dynamics and microstructure were altered by CPB exposure. In spiked samples, prolonged fibrin time (4.4 ± 1.8 to 49.3 ± 16.8 min, p < 0.001) and diminished fibrin network density (0.079 ± 0.010 to 0.001 ± 0.002 A.U, p < 0.001) with increasing heparin concentration were reported by SECM. Furthermore, fibrin network density was not restored to baseline levels in protamine-treated samples. In CPB patients, SECM reported lower fibrin network density in protaminized samples (0.055 ± 0.01 A.U. [Arbitrary units]) vs baseline values (0.066 ± 0.009 A.U.) (p = 0.03) despite comparable fibrin time (baseline = 6.0 ± 1.3, protamine = 6.4 ± 1.6 min, p = 0.5). In these patients, additional metrics including fibrin heterogeneity, length and straightness were quantified. Note, SECM revealed that following protamine administration with CPB exposure, fibrin clots were more heterogeneous (baseline = 0.11 ± 0.02 A.U, protamine = 0.08 ± 0.01 A.U, p = 0.008) with straighter fibers (baseline = 0.918 ± 0.003A.U, protamine = 0.928 ± 0.0006A.U. p < 0.001). By providing the capability to rapidly visualize and quantify fibrin clot microstructure, SECM could furnish a new approach for assessing clot stability and hemostasis in cardiac surgical patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Fibrina/ultraestrutura , Microscopia Confocal/métodos , Coagulação Sanguínea/efeitos dos fármacos , Feminino , Humanos , Masculino
2.
Photoacoustics ; 3(1): 20-5, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25893167

RESUMO

In this work, we experimentally investigate thermal-based nonlinear photoacoustic generation as a mean to discriminate between different types of absorbing particles. The photoacoustic generation from solutions of dye molecules and gold nanospheres (same optical densities) was detected using a high frequency ultrasound transducer (20 MHz). Photoacoustic emission was observed with gold nanospheres at low fluence for an equilibrium temperature around 4 °C, where the linear photoacoustic effect in water vanishes, highlighting the nonlinear emission from the solution of nanospheres. The photoacoustic amplitude was also studied as a function of the equilibrium temperature from 2 °C to 20 °C. While the photoacoustic amplitude from the dye molecules vanished around 4 °C, the photoacoustic amplitude from the gold nanospheres remained significant over the whole temperature range. Our preliminary results suggest that in the context of high frequency photoacoustic imaging, nanoparticles may be discriminated from molecular absorbers based on nanoscale temperature rises.

3.
Biomed Opt Express ; 6(12): 4619-31, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26713182

RESUMO

In this paper we demonstrate the enhancement of the sensing capabilities of glass capillaries. We exploit their properties as optical and acoustic waveguides to transform them potentially into high resolution minimally invasive endoscopic devices. We show two possible applications of silica capillary waveguides demonstrating fluorescence and optical-resolution photoacoustic imaging using a single 330 µm-thick silica capillary. A nanosecond pulsed laser is focused and scanned in front of a capillary by digital phase conjugation through the silica annular ring of the capillary, used as an optical waveguide. We demonstrate optical-resolution photoacoustic images of a 30 µm-thick nylon thread using the water-filled core of the same capillary as an acoustic waveguide, resulting in a fully passive endoscopic device. Moreover, fluorescence images of 1.5 µm beads are obtained collecting the fluorescence signal through the optical waveguide. This kind of silica-capillary waveguide together with wavefront shaping techniques such as digital phase conjugation, paves the way to minimally invasive multi-modal endoscopy.