Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Rev Cardiovasc Med ; 22(4): 1701-1710, 2021 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-34957813

RESUMO

Increased aortic pulse wave velocity (PWV) has been proved as a strong predictor of major adverse cardiovascular events (MACE) in patients after myocardial infarction (MI). Due to the various technical approaches the level of high PWV values show significant differences. We evaluated the cut-off PWV values for MACE prediction using cardiac magnetic resonance imaging (CMR) and oscillometric methods for validating the prognostic value of high PWV in post-infarcted patients. Phase contrast imaging (PCI) and oscillometric based Arteriograph (AG) were compared in this 6 years follow-up study, including 75 consecutive patients of whom 49 suffered previous ST-elevation myocardial infarction (STEMI). Patients received follow-up for MACE comprising all-cause death, non-fatal MI, ischemic stroke, hospitalization for heart failure and coronary revascularization. An acceptable agreement and significant correlation (rho: 0.332, p < 0.01) was found between AG and CMR derived PWV values. The absolute values, however, were significantly higher for AG (median (IQR): 10.4 (9.2-11.9) vs 6.44 (5.64-7.5) m/s; p < 0.001). Totally 51 MACE events occurred during the 6 years follow-up period in post-infarcted patients. Kaplan-Meier analysis in both methods showed significantly lower event-free survival in case of high PWV (CMR: >6.47 m/s, AG: >9.625 m/s, p < 0.001, respectively). Multivariate Cox regression revealed PWV as a predictor of MACE (PWV CMR hazard ratio (HR): 1.31 (CI: 1.1-1.7), PWV AG HR: 1.24 (CI: 1.0-1.5), p < 0.05, respectively). Increased PWV derived by AG and CMR methods are feasible for MACE prediction in post-infarcted patients. However, adjusted cut-off values of PWV are recommended for different techniques to improve individual risk stratification.


Assuntos
Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Seguimentos , Humanos , Imageamento por Ressonância Magnética/métodos , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Prognóstico , Análise de Onda de Pulso , Fatores de Risco
2.
Epilepsia ; 58(3): 356-362, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27988965

RESUMO

OBJECTIVE: To comprehensively analyze ictal asystole (IA) on a large number of subjects. METHODS: We performed a systematic review of case report studies of patients diagnosed with IA (1983-2016). Each included case was characterized with respect to patient history, IA seizure characteristics, diagnostic workup, and therapy. In addition, comparative analyses were also carried out: two alignments were developed based on the delay between epilepsy onset and IA onset ("new-onset" if <1 year, "late-onset" if ≥1 year) and asystole duration (asystole was "very prolonged" if lasted >30 s). RESULTS: One hundred fifty-seven cases were included. All patients had focal epilepsy. In 7% of cases IA developed during a secondary generalized tonic-clonic seizure. Both the seizure-onset zone and the focal seizure activity at asystole beginning were usually temporal (p < 0.001 and p = 0.001, respectively) and were lateralized to the left hemisphere in 62% (p = 0.005 and p = 0.05, respectively). Asystole duration was 18 ± 14 s (mean±SD) (range 3-96 s); 73% of patients had late-onset, 27% had new-onset IA. Compared to late-onset IA, new-onset IA was associated with female gender (p = 0.023), preexisting heart condition (p = 0.014), focal seizure activity at asystole beginning (p = 0.012), normal neuroimaging (p = 0.013), normal interictal EEG (p < 0.001), auditory aura (p = 0.012), and drug-responsive epilepsy (p < 0.001). "Very prolonged" asystole was associated with secondary generalized tonic-clonic seizures (p = 0.003) and tended to occur in extratemporal lobe seizures (p = 0.074). No IA-related death was reported. SIGNIFICANCE: Characteristics considered to be typical of IA (focal, left temporal seizures appearing on grounds of a long-lasting, intractable epilepsy) seem only partially legitimate. We suggest that in new-onset IA, female gender and a preexisting heart condition could serve as predispositions in an otherwise benign epilepsy. We speculate that in late-onset IA, male-predominant changes in neuronal networks in chronic, intractable epilepsy and an accompanying autonomic dysregulation serve as facilitating factors.


Assuntos
Parada Cardíaca , Convulsões/etiologia , Adolescente , Adulto , Idade de Início , Idoso , Criança , Pré-Escolar , Bases de Dados Bibliográficas/estatística & dados numéricos , Eletroencefalografia , Feminino , Lateralidade Funcional , Parada Cardíaca/complicações , Parada Cardíaca/diagnóstico , Parada Cardíaca/terapia , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Adulto Jovem
3.
J Magn Reson Imaging ; 43(4): 911-20, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26354594

RESUMO

PURPOSE: To test whether signal intensity percent infarct mapping (SI-PIM) accurately determines the size of myocardial infarct (MI) regardless of infarct age. MATERIALS AND METHODS: Forty-five swine with reperfused MI underwent 1.5T late gadolinium enhancement (LGE) magnetic resonance imaging (MRI) after bolus injection of 0.2 mmol/kg Gd(DTPA) on days 2-62 following MI. Animals were classified into acute, healing, and healed groups by pathology. Infarct volume (IV) and infarct fraction (IF) were determined by two readers, using binary techniques (including 2-5 standard deviations [SD] above the remote, and full-width at half-maximum) and the SI-PIM method. Triphenyl-tetrazolium-chloride staining (TTC) was performed as reference. Bias (percent under/overestimation of IV relative to TTC) of each quantification method was calculated. Bland-Altman analysis was done to test the accuracy of the quantification methods, while intraclass correlation coefficient (ICC) analysis was done to assess intra- and interobserver agreement. RESULTS: Bias of the MRI quantification methods do not depend on the age of the MI. Full-width at half-maximum (FWHM) and SI-PIM gave the best estimate of MI volume determined by the reference TTC (P-values for the FWHM and SI-PIM methods were 0.183, 0.26, 0.95, and 0.073, 0.091, 0.73 in Group 1, Group 2, and Group 3, respectively), while using any of the binary thresholds of 2-4 SDs above the remote myocardium showed significant overestimation. The 5 SD method, however, provided similar IV compared to TTC and was shown to be independent of the size and age of MI. ICC analysis showed excellent inter- and intraobserver agreement between the readers. CONCLUSION: Our results indicate that the SI-PIM method can accurately determine MI volume regardless of the pathological stage of MI. Once tested, it may prove to be useful for the clinic.


Assuntos
Infarto do Miocárdio/diagnóstico , Processamento de Sinais Assistido por Computador , Animais , Temperatura Corporal , Meios de Contraste/química , Eletroencefalografia , Gadolínio/química , Gadolínio DTPA/química , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Reperfusão Miocárdica , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Suínos , Sais de Tetrazólio/química , Resultado do Tratamento
4.
Eur Heart J ; 34(10): 775-81, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22390914

RESUMO

AIMS: Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. METHODS AND RESULTS: In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: -0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. CONCLUSION: In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CAD.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Angiografia por Ressonância Magnética/efeitos adversos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
5.
J Clin Med ; 13(4)2024 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-38398342

RESUMO

(1) Background: During pulmonary vein isolation (PVI) for atrial fibrillation (AF), multipolar mapping catheters (MMC) are often used. We aimed to compare the procedural outcomes of two MMCs, specifically a circular-shaped and a five-spline-shaped MMC. (2) Methods: We enrolled 70 consecutive patients in our prospective, observational trial undergoing PVI procedures for paroxysmal AF. The initial 35 patients underwent PVI procedures with circular-shaped MMC guidance (Lasso Group), and the procedures for the latter 35 cases were performed using five-spline-shaped MMC (PentaRay Group). (3) Results: No significant differences were identified between the two groups in total procedure time (80.2 ± 17.7 min vs. 75.7 ± 14.8 min, p = 0.13), time from femoral vein puncture to the initiation of the mapping (31.2 ± 7 min vs. 28.9 ± 6.8, p = 0.80), mapping time (8 (6; 13) min vs. 9 (6.5; 10.5) min, p = 0.73), duration between the first and last ablation (32 (30; 36) min vs. 33 (26; 40) min, p = 0.52), validation time (3 (2; 4) min vs. 3 (1; 5) min, p = 0.46), first pass success rates (89% vs. 91%, p = 0.71), left atrial dwelling time (46 (37; 53) min vs. 45 (36.5; 53) min, p = 0.56), fluoroscopy data (time: 150 ± 71 s vs. 143 ± 56 s, p = 0.14; dose: 6.7 ± 4 mGy vs. 7.4 ± 4.4 mGy, p = 0.90), total ablation time (1187 (1063; 1534) s vs. 1150.5 (1053; 1393.5) s, p = 0.49), the number of ablations (78 (73; 93) vs. 83 (71.3; 92.8), p = 0.60), and total ablation energy (52,300 (47,265; 66,804) J vs. 49,666 (46,395; 56,502) J, p = 0.35). (4) Conclusions: This study finds comparable procedural outcomes bet-ween circular-shaped and five-spline-shaped MMCs for PVI in paroxysmal AF, supporting their interchangeability in clinical practice for anatomical mapping.

6.
Catheter Cardiovasc Interv ; 81(4): 689-97, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22431438

RESUMO

OBJECTIVES: To develop a magnetic resonance imaging (MRI) compatible, percutaneous technique for the generation of nonreperfused myocardial infarct (MI). BACKGROUND: Modeling nontreated MI has major importance in the development and preclinical testing of new therapeutic strategies for patients missing the time window suitable for revascularization following MI. METHODS: In 31 male swine, nonreperfused MI was generated by permanent occlusion of either the LAD or LCX coronary artery using 900 µm Embozene™ microspheres. Animals were monitored for 90 min postocclusion. Surviving animals were followed up for 2 (n = 6), 4 (n = 6), 14 (n = 6), or 56 (n = 6) days. At the end of the planned study session, contrast enhanced MRI, triphenyl-tetrazolium-chloride staining, and microscopic histopathology were carried out. RESULTS: The mortality rate in this study was 22.6%. Intraoperative arrhythmias occurred in 14 cases: premature ventricular complexes with (5) or without (3) ventricular tachycardia, 2nd degree atrio-ventricular block (1), and ventricular fibrillation (6). MRI, TTC, and histology confirmed the existence of MI in every case. Macroscopic pathology showed that the microspheres caused a practically total occlusion at the epicardial level of the coronary artery. Multiple infarcts were detected in one case, probably due to unintentional reflux of the microspheres. Microspheres retained in the coronary arteries did not cause any MRI artifact. CONCLUSIONS: The generation of nonreperfused MI is feasible by percutaneous injection of Embozene into the coronary artery system. The MI model thus obtained is suitable for the purposes of MRI experiments.


Assuntos
Circulação Coronária , Infarto do Miocárdio/etiologia , Polímeros , Animais , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Corantes , Meios de Contraste , Modelos Animais de Doenças , Estudos de Viabilidade , Injeções , Iohexol , Imagem Cinética por Ressonância Magnética , Masculino , Microesferas , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Miocárdio/patologia , Coloração e Rotulagem/métodos , Suínos , Sais de Tetrazólio , Fatores de Tempo
7.
Can J Physiol Pharmacol ; 91(8): 617-24, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23888899

RESUMO

The diagnostic characteristics of electromechanical mapping (EMM) were evaluated in porcine myocardial infarction (MI) models with the parallel application of cardiac magnetic resonance imaging (cMRI) from the aspect of different pathophysiology and localization. Balloon occlusion in the left anterior descending coronary artery (LAD balloon group) or coil deployment in the LAD (LAD coil group) or circumflex artery (Cx coil group) was applied percutaneously in 16 domestic pigs. Regional left ventricular viability data were captured via cMRI and EMM. The unipolar voltage (UV) value was significantly decreased in segments containing transmural and subendocardial late enhancement compared with viable segments in the LAD balloon, LAD coil, and Cx coil groups. Receiver operating characteristic analysis revealed area under the curve values of 0.809 and 0.691 in the LAD infarct territory, and 0.864 and 0.855 in the Cx infarct territory for the UV compared with cMRI viability results as transmural late enhancement or viable tissue and subendocardial late enhancement or viable tissue, respectively. In conclusion, the UV value detected the presence of scar tissue with differential transmural extent and which represented proper diagnostic features both in the reperfused and nonreperfused models. This data could provide additional benefit in the clinical use of EMM for diagnostic purposes.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Modelos Animais de Doenças , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Animais , Angiografia Coronária , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Curva ROC , Sensibilidade e Especificidade , Sus scrofa
8.
J Clin Med ; 12(17)2023 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-37685645

RESUMO

Radiofrequency (RF) catheter ablation is an effective treatment option for targeting the slow pathway (SP) in atrioventricular nodal reentry tachycardia (AVNRT). Previous data suggested that using intracardiac echocardiography (ICE) guidance could improve procedural outcomes when compared to using fluoroscopy alone. In this prospective study, we aimed to compare the effectiveness of an electroanatomical mapping system (EAMS)-guided approach with an ICE-guided approach for SP ablation. Eighty patients undergoing SP ablation for AVNRT were randomly assigned to either the ICE-guided or EAMS-guided group. If the procedural endpoint was not achieved after 8 RF applications; patients were allowed to crossover to the ICE-guided group. The ICE-guided approach reduced the total procedure time (61.0 (56.0; 66.8) min vs. 71.5 (61.0; 80.8) min, p < 0.01). However, the total fluoroscopy time was shorter (0 (0-0) s vs. 83.5 (58.5-133.25) s, p < 0.001) and the radiation dose was lower (0 (0-0) mGy vs. 3.3 (2.0-4.7) mGy, p < 0.001) with EAMS-guidance. The ICE-guided group had a lower number of RF applications (4 (3-5) vs. 5 (3.0-7.8), p = 0.03) and total ablation time (98.5 (66.8-186) s vs. 136.5 (100.5-215.8) s, p = 0.02). Nine out of 40 patients (22.5%) in the EAMS-guided group crossed over to the ICE-guided group, and they were successfully treated with similar RF applications in terms of number, time, and energy compared to the ICE-guided group. There were no recurrences during the follow-up period. In conclusion, the utilization of ICE guidance during SP ablation has demonstrated notable reductions in procedural time and RF delivery when compared to procedures guided by EAMS. In challenging cases, an early switch to ICE-guided ablation may be the optimal choice for achieving successful treatment.

9.
Front Cardiovasc Med ; 10: 1244137, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37900565

RESUMO

Introduction: Catheter ablation is the preferred treatment for typical atrial flutter (AFl), but it can be challenging due to anatomical abnormalities. The use of 3D electroanatomical mapping systems (EAMS) has reduced fluoroscopy exposure during AFl ablation. Intracardiac echocardiography (ICE) has also shown benefits in reducing radiation exposure during AFl ablation. However, there is a lack of evidence on the feasibility of ICE-guided, zero-fluoroscopy AFl ablation without the use of EAMS. Methods: In this prospective study, we enrolled 80 patients with CTI-dependent AFl. The first 40 patients underwent standard fluoroscopy + ICE-guided ablation (Standard ICE group), while the other 40 patients underwent zero-fluoroscopy ablation using only ICE (Zero ICE group). Procedure outcomes, including acute success, procedure time, fluoroscopy time, radiation dose, and complications, were compared between the groups. Results: The acute success rate was 100% in both groups. Out of the 40 cases, the zero-fluoroscopy strategy was successfully implemented in 39 cases (97.5%) in the Zero ICE group. There were no significant differences in procedure time [55.5 (46.5; 66.8) min vs. 51.5 (44.0; 65.5), p = 0.50] and puncture to first ablation time [18 (13.5; 23) min vs. 19 (15; 23.5) min, p = 0.50] between the groups. The Zero ICE group had significantly lower fluoroscopy time [57 (36.3; 90) sec vs. 0 (0; 0) sec, p < 0.001] and dose [3.17 (2.27; 5.63) mGy vs. 0 (0; 0) mGy, p < 0.001] compared to the Standard ICE group. Total ablation time was longer in the Standard ICE group [597 (447; 908) sec vs. 430 (260; 750), p = 0.02], but total ablation energy [22,458 (14,836; 31,116) Ws vs. 17,043 (10,533; 29,302) Ws, p = 0.10] did not differ significantly. First-pass bidirectional conduction block of the CTI and acute reconnection rates were similar between the groups. No complications or recurrences were observed during the follow-up period. Conclusion: Our study suggests that zero-fluoroscopy CTI ablation guided solely by ICE for AFl is feasible and safe. Further investigation is warranted for broader validation.

10.
J Clin Med ; 12(19)2023 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-37834921

RESUMO

Atrial flutter (AFL) represents a prevalent variant of supraventricular tachycardia, distinguished by a macro-reentrant pathway encompassing the cavotricuspid isthmus (CTI). Radiofrequency (RF) catheter ablation stands as the favored therapeutic modality for managing recurring CTI-dependent AFL. Intracardiac echocardiography (ICE) has been proposed as a method to reduce radiation exposure during CTI ablation. This study aims to comprehensively compare procedural parameters between ICE-guided CTI ablation and fluoroscopy-only procedures. A total of 370 consecutive patients were enrolled in our single-center retrospective study. In 151 patients, procedures were performed using fluoroscopy guidance only, while 219 patients underwent ICE-guided CTI ablation. ICE guidance significantly reduced fluoroscopy time (73 (36; 175) s vs. 900 (566; 1179) s; p < 0.001), fluoroscopy dose (2.45 (0.6; 5.1) mGy vs. 40.5 (25.7; 62.9) mGy; p < 0.001), and total procedure time (70 (52; 90) min vs. 87.5 (60; 102.5) min; p < 0.001). Total ablation time (657 (412; 981) s vs. 910 (616; 1367) s; p < 0.001) and the time from the first to last ablation (20 (11; 36) min vs. 40 (25; 55) min; p < 0.01) were also significantly shorter in the ICE-guided group. Acute success rate was 100% in both groups, and no major complications occurred in either group. ICE-guided CTI ablation in patients with AFL resulted in shorter procedure times, reduced fluoroscopy exposure, and decreased ablation times, compared to the standard fluoroscopy-only approach.

11.
Front Cardiovasc Med ; 10: 1178783, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37396578

RESUMO

Introduction: Catheter ablation for atrial fibrillation (AF) is the most frequently performed cardiac ablation procedure worldwide. The majority of ablations can now be performed safely with minimal radiation exposure or even without the use of fluoroscopy, thanks to advances in 3-dimensional electroanatomical mapping systems and/or intracardiac echocardiography. The aim of this study was to conduct a meta-analysis to compare the effectiveness of zero fluoroscopy (ZF) versus non-zero fluoroscopy (NZF) strategies for AF ablation procedures. Methods: Electronic databases were searched and systematically reviewed for studies comparing procedural parameters and outcomes of ZF vs. NZF approaches in patients undergoing catheter ablation for AF. We used a random-effects model to derive the mean difference (MD) and risk ratios (RR) with a 95% confidence interval (CI). Results: Our meta-analysis included seven studies comprising 1,593 patients. The ZF approach was found to be feasible in 95.1% of patients. Compared to the NZF approach, the ZF approach significantly reduced procedure time [mean difference (MD): -9.11 min (95% CI: -12.93 to -5.30 min; p < 0.01)], fluoroscopy time [MD: -5.21 min (95% CI: -5.51 to -4.91 min; p < 0.01)], and fluoroscopy dose [MD: -3.96 mGy (95% CI: -4.27 to -3.64; p < 0.01)]. However, there was no significant difference between the two groups in terms of total ablation time [MD: -104.26 s (95% CI: -183.37 to -25.14; p = 0.12)]. Furthermore, there was no significant difference in the acute [risk ratio (RR): 1.01, 95% CI: 1.00-1.02; p = 0.72] and long-term success rates (RR: 0.96, 95% CI: 0.90-1.03; p = 0.56) between the ZF and NZF methods. The complication rate was 2.76% in the entire study population and did not differ between the groups (RR: 0.94, 95% CI: 0.41-2.15; p = 0.89). Conclusion: The ZF approach is a feasible method for AF ablation procedures. It significantly reduces procedure time and radiation exposure without compromising the acute and long-term success rates or complication rates.

12.
Clin Cardiol ; 46(8): 942-949, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37408170

RESUMO

BACKGROUND: Catheter ablation is a rarely used procedure to treat arrhythmias during pregnancy. HYPOTHESIS: In the case of maternal arrhythmia during pregnancy, zero-fluoroscopic catheter ablation is preferable to medical treatment. METHODS: Between April 2014 and September 2021, we examined the demographic data, procedural parameters, and fetal and maternal outcomes in pregnant women undergoing ablation at the Gottsegen National Cardiovascular Center and University of Pécs Medical School, Heart Institute. RESULTS: Fourteen procedures (14 electrophysiological studies [EPS], 13 ablations) performed on 13 pregnant women (age 30.3 ± 5.2 years, primipara n = 6) were studied. During EPS, 12 patients had inducible arrhythmias. Atrial tachycardia was confirmed in three, atrioventricular re-entry tachycardia via manifest accessory pathway (AP) in three, and via concealed AP in one case. Atrioventricular nodal re-entry tachycardia was confirmed in three and sustained monomorphic ventricular tachycardia in two cases. Eleven radiofrequency ablation (84.6%) and two cryoablation (15.4%) were performed. The electroanatomical mapping system was used in all cases. Transseptal puncture was performed in two cases (15.4%) due to left lateral APs. The mean procedure time was 76.0±33.0 minutes. All procedures were performed without fluoroscopy. No complications occurred. During the follow-up, arrhythmia-free survival was achieved in all cases, but in two patients, we used antiarrhythmic drugs (AADs) to achieve it. APGAR score was within the normal range in all cases [median (interquartile range), 9.0/10.0 (9.0-10.0/9.3-10.0)]. CONCLUSIONS: Zero-fluoroscopic catheter ablation was an effective and safe treatment option for our 13 pregnant patients. Catheter ablation may have less side effects on fetal development than the use of AADs during pregnancy.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Feminino , Gravidez , Adulto , Gestantes , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Arritmias Cardíacas/etiologia , Taquicardia Ventricular/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Catéteres , Resultado do Tratamento
13.
J Cardiovasc Magn Reson ; 14: 61, 2012 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-22938651

RESUMO

BACKGROUND: Perfusion-cardiovascular magnetic resonance (CMR) is generally accepted as an alternative to SPECT to assess myocardial ischemia non-invasively. However its performance vs gated-SPECT and in sub-populations is not fully established. The goal was to compare in a multicenter setting the diagnostic performance of perfusion-CMR and gated-SPECT for the detection of CAD in various populations using conventional x-ray coronary angiography (CXA) as the standard of reference. METHODS: In 33 centers (in US and Europe) 533 patients, eligible for CXA or SPECT, were enrolled in this multivendor trial. SPECT and CXA were performed within 4 weeks before or after CMR in all patients. Prevalence of CAD in the sample was 49% and 515 patients received MR contrast medium. Drop-out rates for CMR and SPECT were 5.6% and 3.7%, respectively (ns). The study was powered for the primary endpoint of non-inferiority of CMR vs SPECT for both, sensitivity and specificity for the detection of CAD (using a single-threshold reading), the results for the primary endpoint were reported elsewhere. In this article secondary endpoints are presented, i.e. the diagnostic performance of CMR versus SPECT in subpopulations such as multi-vessel disease (MVD), in men, in women, and in patients without prior myocardial infarction (MI). For diagnostic performance assessment the area under the receiver-operator-characteristics-curve (AUC) was calculated. Readers were blinded versus clinical data, CXA, and imaging results. RESULTS: The diagnostic performance (= area under ROC = AUC) of CMR was superior to SPECT (p = 0.0004, n = 425) and to gated-SPECT (p = 0.018, n = 253). CMR performed better than SPECT in MVD (p = 0.003 vs all SPECT, p = 0.04 vs gated-SPECT), in men (p = 0.004, n = 313) and in women (p = 0.03, n = 112) as well as in the non-infarct patients (p = 0.005, n = 186 in 1-3 vessel disease and p = 0.015, n = 140 in MVD). CONCLUSION: In this large multicenter, multivendor study the diagnostic performance of perfusion-CMR to detect CAD was superior to perfusion SPECT in the entire population and in sub-groups. Perfusion-CMR can be recommended as an alternative for SPECT imaging. TRIAL REGISTRATION: ClinicalTrials.gov, Identifier: NCT00977093.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Circulação Coronária , Imagem Cinética por Ressonância Magnética/métodos , Isquemia Miocárdica/diagnóstico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Doença da Artéria Coronariana/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
14.
J Electrocardiol ; 45(3): 280-2, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-21908000

RESUMO

Isolated occlusion of the septal perforating branch of the left anterior descending coronary artery is extremely rare. As a result, little is known about its electrocardiographic manifestations compared with those of an anteroseptal myocardial infarction. We present the case of an isolated septal myocardial infarction with ST-segment elevation.


Assuntos
Oclusão Coronária/complicações , Oclusão Coronária/diagnóstico , Eletrocardiografia/métodos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/etiologia , Adulto , Diagnóstico Diferencial , Humanos , Masculino , Doenças Raras/complicações , Doenças Raras/diagnóstico
15.
Orv Hetil ; 153(41): 1638-44, 2012 Oct 14.
Artigo em Húngaro | MEDLINE | ID: mdl-23045314

RESUMO

INTRODUCTION: At the Markusovszky Hospital, Vas County, Hungary, cardiac magnetic resonance imaging has been routinely used since July, 2009. In the majority of cases this method has been applied for the assessment of myocardial viability in patients with chronic ischemic heart disease and, in a smaller number of cases, for the evaluation of patients with myocarditis, cardiomyopathy and syncope with uncertain etiology in young athletes. AIMS: The aim of the study was to analyze the clinical value of cardiac magnetic resonance imaging in assessing the viability of affected myocardial regions due to chronic occlusion of major coronary arteries. METHODS: Delayed-enhancement cardiac magnetic resonance examination was performed in 88 patients who had 103 myocardial regions affected with chronic occlusion of the coronary arteries. The number of affected myocardial regions which proved to be treatable with coronary artery intervention and the number of regions where revascularization strategy was based on cardiac magnetic resonance imaging findings were analyzed. RESULTS: Based on findings from cardiac magnetic resonance imaging, revascularization strategy was set up in 88 myocardial regions corresponding to 83.5% of all affected myocardial regions included in this study. CONCLUSIONS: Delayed-enhancement cardiac magnetic resonance imaging appears to be a powerful tool to choose the optimal reperfusion strategy in patients with chronic coronary occlusion. Although this diagnostic method is relatively expensive, its accuracy regarding the features of myocardial viability such as transmural extension of the lesion within the affected region is higher than that of other methods (e.g. myocardium scintigraphy or stress echocardiography).


Assuntos
Hospitais de Condado/estatística & dados numéricos , Imageamento por Ressonância Magnética , Isquemia Miocárdica/diagnóstico , Miocárdio/patologia , Adulto , Idoso , Feminino , Humanos , Hungria/epidemiologia , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Imageamento por Ressonância Magnética/tendências , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/etiologia , Isquemia Miocárdica/patologia , Valor Preditivo dos Testes
16.
Orv Hetil ; 163(19): 767-772, 2022 May 08.
Artigo em Húngaro | MEDLINE | ID: mdl-35526183

RESUMO

We present the case of a 58-year-old woman, suffering from high blood pressure, who presented with documented frequently occurring paroxysmal atrial fibrillation attacks. She underwent two prior pulmonary vein isolations, but her palpitations did not cease. We aimed to achieve a long period free of symptoms, and a 3D MRI late enhancement scar map of the left atrium was obtained before the planned third pulmonary vein isolation procedure to visualize the assumed pulmonary vein reconnection sites. First, the endocardial and epicardial contours of the thin left atrial wall were manually determined on the images, then color-coding was added based on the trasmurality of contrast enhancement in the wall. The reconstructed 3D color-coded left atrial surface revealed the localization of left atrial antral wall scars. These images were integrated into the electroanatomical mapping system and ablation was carried out selectively on the spots showing gaps in the antral scar. Isolation was achieved in all four veins without any complications. The patient has become symptom-free for years now. The reconstructed left atrial 3D MRI images gained in an innovative process visualized the gaps in the previous ablation lines and these images were integrated to guide the first gap-closure redo pulmonary vein isolation procedure in Hungary.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Cicatriz , Feminino , Humanos , Hungria , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade
17.
Front Cardiovasc Med ; 9: 856145, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35479287

RESUMO

Introduction: Catheter ablations for cardiac arrhythmias are conventionally performed under fluoroscopic guidance. To guide these procedures, zero/minimal fluoroscopy (Z/MF) approaches have become available, using three-dimensional electroanatomical mapping systems. Our aim was to conduct a meta-analysis comparing these two different methods for the treatment of paroxysmal supraventricular tachycardia (SVT). Methods: Electronic databases were searched and systematically reviewed for studies comparing procedural parameters and outcomes of conventional, fluoroscopy-guided vs. Z/MF approaches in patients undergoing electrophysiology (EP) procedures for SVTs. The random-effects model was used to derive mean difference (MD) and risk ratios (RRs) with 95% confidence interval (CI). Results: Twenty-four studies involving 9,074 patients met our inclusion criteria. There was no difference between the groups in terms of acute success rate (RR = 1.00, 95% CI, 0.99-1.01; p = 0.97) and long-term success rate (RR: 1.01, 95% CI, 1.00-1.03; p = 0.13). Compared to the conventional method, zero-and-minimal fluoroscopy (Z/MF) ablation significantly reduced fluoroscopic time [MD: -1.58 min (95% CI, -2.21 to -0.96 min; p < 0.01)] and ablation time [MD: -25.23 s (95% CI: -42.04 to -8.43 s; p < 0.01)]. No difference could be detected between the two groups in terms of the procedure time [MD: 3.06 min (95% CI: -0.97 to 7.08; p = 0.14)] and the number of ablation applications [MD: 0.13 (95% CI: -0.86 to 1.11; p = 0.80)]. The complication rate was 1.59% in the entire study population and did not differ among the groups (RR: 0.68, 95% CI: 0.45-1.05; p = 0.08). Conclusions: The Z/MF approach for the catheter ablation of SVTs is a feasible method that reduces radiation exposure and ablation time without compromising the acute and long-term success or complication rates.

18.
Front Cardiovasc Med ; 9: 1033755, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36465461

RESUMO

Introduction: Steerable sheaths (SSs) are frequently used to improve catheter contact during pulmonary vein isolation (PVI) procedures. A new type of visualizable (by electroanatomical mapping system) SS has become available in clinical treatment. Purpose: We aimed to compare procedural data of visualizable vs. non-visualizable steerable sheath assisted PVI procedures in patients with atrial fibrillation (AF). Methods: In this single-centre randomized study, we enrolled a total of 100 consecutive patients who underwent PVI due to AF. Results: A total of 100 patients were randomized into 2 groups (visualizable SS group: 50; non-visualizable SS group: 50). Acute ablation success was 100% and the rate of the first pass isolation were similar (92% vs. 89%; p = 0.88). Using visualizable SS, left atrial (LA) procedure time (53.1 [41.3; 73.1] min vs. 59.5 [47.6; 74.1] min.; p = 0.04), LA fluoroscopy time (0 [0; 0] s vs. 17.5 [5.5; 69.25] s; p < 0.01) and LA fluoroscopy dose (0 [0; 0.27] mGy vs. 0.74 [0.16; 2.34] mGy; p < 0.01) was significantly less, however, there was no difference in the total procedural time (90 ± 35.2 min vs. 99.5 ± 31.8 min; p = 0.13), total fluoroscopy time (184 ± 89 s vs. 193 ± 44 s; p = 0.79), and total fluoroscopy dose (9.12 ± 1.98 mGy vs. 9.97 ± 2.27 mGy; p = 0.76). Compared to standard, non-visualizable SS group, the number of radiofrequency ablations was fewer (69 [58; 80] vs. 79 [73; 86); p < 0.01) as well as total ablation time was reduced (1049 sec. [853; 1175] vs. 1265 sec. [1085; 1441]; p < 0.01) in the visualizable SS cohort. No major complications occurred in either group. Conclusion: Compared to the standard, non-visualizable SS, visualizable SS significantly reduces the left atrial procedure time, RF delivery and fluoroscopy exposure without compromising its safety or effectiveness in patients undergoing PVI procedures for AF.

19.
Orv Hetil ; 152(8): 285-91, 2011 Feb 20.
Artigo em Húngaro | MEDLINE | ID: mdl-21310697

RESUMO

Patients with peripheral arterial disease often have coronary heart disease, as well. However, their assessment with classical noninvasive cardiology methods is often non-diagnostic or limited. The aim of this study was to analyze the feasibility and the risks of dobutamine stress cardiovascular MRI for cardiac evaluation of patients with peripheral arterial disease. 21 patients with peripheral artery disease (mean±SD age 64.3±7.7 years) were studied prospectively with dobutamine stress cardiovascular MRI. The protocol was completed by all of 21 patients. The target heart rate was attained in 95.2% of the studies. No serious adverse event occurred. The image quality scores (1-4) for all ventricular wall segments were high (median, interquartile range) (4 [4-4]). Five patients (23.8%) have inducible wall motion abnormality. Interobserver agreement was almost perfect for wall motion scores (κ = 0.87, p<0.0001). Dobutamine stress cardiovascular MRI is feasible with low risk for the cardiological assessment of patients with peripheral arterial disease.


Assuntos
Doença das Coronárias/diagnóstico , Doença das Coronárias/fisiopatologia , Dobutamina , Imageamento por Ressonância Magnética/métodos , Doença Arterial Periférica/complicações , Simpatomiméticos , Idoso , Dobutamina/efeitos adversos , Estudos de Viabilidade , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Simpatomiméticos/efeitos adversos
20.
Orv Hetil ; 162(46): 1856-1858, 2021 11 14.
Artigo em Húngaro | MEDLINE | ID: mdl-34775371

RESUMO

Összefoglaló. A dystrophia myotonica (DM) multiszisztémás, autoszomális domináns módon öröklodo, többségében felnottkori izombetegség, melynek incidenciája 1 : 8000. A betegség kapcsán fellépo izomszöveti degeneráció a harántcsíkolt izomszövet átépülése mellett a szívizomszövetet is érinti, ami fontos oki szerepet játszik az érintett betegek csökkent várható élettartamában. A DM-ben szenvedok halálozásának közel egyharmadáért a cardiovascularis okok tehetok felelossé. Esetriportunkban egy 52 éves, korábban kritikus bradycardia és I. fokú atrioventricularis blokk miatt pacemakerimplantáción átesett, DM-mel diagnosztizált nobeteg kardiológiai utánkövetését mutatjuk be. A hirtelen szívhalál rizikóstratifikációja céljából elvégzett invazív elektrofiziológiai vizsgálat során kamrafibrilláció lépett fel, így a korábban implantált pacemakerelektródák mellé sokkelektróda került beültetésre, a pacemakerkészüléket implantálható kardioverter-defibrillátorra (ICD) cseréltük. Az 1 éves ICD-kontrollvizsgálat során azt találtuk, hogy a beültetés óta 22, tartós kamrai tachycardiával járó epizód lépett fel, melyek közül a készülék valamennyit sikeresen terminálta. Az eset bemutatásával szeretnénk rámutatni arra, hogy a magas cardiovascularis rizikócsoportba tartozó DM-betegek azonosítása kiemelkedo fontosságú lehet a hirtelen szívhalál megelozése érdekében. Orv Hetil. 2021; 162(46): 1856-1858. Summary. Myotonic dystrophy (DM) is one of the most frequent adulthood diseases of the skeletal muscles, which develops multisystemic features and shows autosomal dominant trait. In DM, tissue degeneration affects not only the skeletal, but the cardiac muscle, too. In one third of the patients, the cause of death is of cardiac origin. We report on our patient's case, who was diagnosed with DM at the age of 52, in whom episodes of critical bradycardia with first-degree atrioventricular block was detected, resulting in a pacemaker implantation. Invasive cardiac electrophysiological study was performed, during which ventricular fibrillation was registered. A shock electrode was added to the previously implanted pacemaker, enabling defibrillation in case of detection of a sustained ventricular arrhythmia. During the 1-year follow-up, 22 episodes of sustained ventricular tachycardia were identified, with the device successfully terminating the malignant arrhythmias. Our case shows that electrophysiological study and the succeeding implantation of an implantable cardiac defibrillator is highly important in identifying and terminating ventricular arrhythmias in high-risk DM patients. Orv Hetil. 2021; 162(46): 1856-1858.


Assuntos
Desfibriladores Implantáveis , Distrofia Miotônica , Adulto , Arritmias Cardíacas , Humanos , Distrofia Miotônica/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA