Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Neuroradiol ; 49(1): 80-86, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33785389

RESUMO

BACKGROUND AND PURPOSE: Several studies have reported good long-term results in the occlusion of intracranial aneurysms with flow diverter treatment. The aim of this study was to report the safety and six-month follow-up outcomes using the new Surpass Evolve flow diverter in the treatment of intracranial aneurysms. MATERIALS AND METHODS: Consecutive patients with intracranial aneurysm treated with Surpass Evolve flow diverter in two high-volume neurovascular centers between May 2019 and January 2020 were retrospectively reviewed. Procedure-related complications, aneurysm occlusion (O'Kelly-Marotta grading scale), and clinical outcomes were assessed. RESULTS: Twenty-nine patients with 30 aneurysms were included in the study. Favorable aneurysm occlusion (O'Kelly Marotta grading scale C-D) at six-month follow-up was achieved in 21/27 (78%) aneurysms. No clinical procedure related thromboembolic complications were encountered. Twenty-three out of 24 patients with unruptured aneurysms treated with Surpass Evolve remained clinically intact at clinical follow-up. There was one fatal hemorrhagic procedure-related complication (3%). In five patients with ruptured aneurysms, no early or late rebleeds occurred from the aneurysms. CONCLUSIONS: Surpass Evolve FD worked technically well with no intraprocedural thromboembolic complications and occlusion rates comparable to other FDs.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Angiografia Cerebral , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Estudos Retrospectivos , Stents , Resultado do Tratamento
2.
Eur J Radiol ; 158: 110604, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36493497

RESUMO

BACKGROUND AND PURPOSE: Transradial access (TRA) has increased popularity among neurointerventionalists during a short time period but until recently there have been no devices designed especially for radial use. MATERIALS AND METHODS: Consecutive neurointerventional procedures with an intention to perform TRA with the Rist radial access guide catheter between April 2021 and May 2022 were retrospectively reviewed. Possible access site complications, other procedure-related complications and information on successful catherization of the target vessel as well as whether the procedure had been successful were collected. RESULTS: Information from 100 patients was included in the study. The most general procedure was flow diversion (29%) followed by WEB embolization (20 %). Four patients (4%) needed conversion to femoral access. The triaxial system was used in 76% of the procedures. Four patients (4%) experienced access site or device related complications, none of those were serious. Six patients had clinically relevant procedure related complications. CONCLUSIONS: It is concluded that the Rist device can be used safely for a large variety of neurointerventions with a short learning curve.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Humanos , Artéria Radial/diagnóstico por imagem , Artéria Radial/cirurgia , Procedimentos Endovasculares/métodos , Estudos Retrospectivos , Finlândia , Embolização Terapêutica/métodos , Resultado do Tratamento
3.
J Neurointerv Surg ; 2023 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-37355257

RESUMO

BACKGROUND: Physician variablity in preoperative planning of endovascular implant deployment and associated inaccuracies have not been documented. This study aimed to quantify the variability in accuracy of physician flow diverter (FD) planning and directly compares it with PreSize Neurovascular (Oxford Heartbeat Ltd) software simulations. METHODS: Eight experienced neurointerventionalists (NIs), blinded to procedural details, were provided with preoperative 3D rotational angiography (3D-RA) volumetric data along with images annotated with the distal landing location of a deployed Surpass Evolve (Stryker Neurovascular) FD from 51 patient cases. NIs were asked to perform a planning routine reflecting their normal practice and estimate the stent's proximal landing using volumetric data and the labeled dimensions of the FD used. Equivalent deployed length estimation was performed using PreSize software. NI- and software-estimated lengths were compared with postprocedural observed deployed stent length (control) using Bland-Altman plots. NI assessment agreement was assessed with the intraclass correlation coefficient (ICC). RESULTS: The mean accuracy of NI-estimated deployed FD length was 81% (±15%) versus PreSize's accuracy of 95% (±4%), demonstrating significantly higher accuracy for the software (p<0.001). The mean absolute error between estimated and control lengths was 4 mm (±3.5 mm, range 0.03-30.2 mm) for NIs and 1 mm (±0.9 mm, range 0.01-3.9 mm) for PreSize. No discernable trends in accuracy among NIs or across vasculature and aneurysm morphology (size, vessel diameter, tortuousity) were found. CONCLUSIONS: The study quantified experienced physicians' significant variablity in predicting an FD deployment with current planning approaches. In comparison, PreSize-simulated FD deployment was consistently more accurate and reliable, demonstrating its potential to improve standard of practice.

4.
J Neurointerv Surg ; 15(1): 63-69, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35172983

RESUMO

BACKGROUND: Flow diversion is an innovative and increasingly used technique for the treatment of intracranial aneurysms. New flow diverters (FDs) are being introduced to improve the safety and efficacy of this treatment. The aim of this study was to assess the safety, feasibility, and efficacy of the new Pipeline Vantage (PV) FD. METHODS: Patients with intracranial aneurysms treated with the PV at 10 international neurovascular centers were retrospectively analyzed. Patient and aneurysm characteristics, procedural parameters, complications, and the grade of occlusion were assessed. RESULTS: 60 patients with 70 aneurysms (5.0% with acute hemorrhage, 90.0% located in the anterior circulation) were included. 82 PVs were implanted in 61 treatment sessions. The PV could be successfully implanted in all treatments. Additional coiling was performed in 18.6%, and in-stent balloon angioplasty (to enhance the vessel wall apposition) in 24.6%. Periprocedural technical complications occurred in 24.6% of the treatments, were predominantly FD deployment problems, and were all asymptomatic. The overall symptomatic complication rate was 8.2% and the neurological symptomatic complication rate was 3.3%. Only one symptomatic complication was device-related (perforator artery infarctions leading to stroke). After a mean follow-up of 7.1 months, the rate of complete aneurysm occlusion was 77.9%. One patient (1.7%) died due to aneurysmal subarachnoid hemorrhage which occurred before treatment, unrelated to the procedure. CONCLUSIONS: The new PV FD is safe and feasible for the treatment of intracranial aneurysms. The short-term occlusion rates are promising but need further assessment in prospective long-term follow-up studies.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Estudos Retrospectivos , Estudos Prospectivos , Resultado do Tratamento , Stents , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos
5.
Brain Behav ; 12(9): e2756, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36050910

RESUMO

BACKGROUND: Perimesencephalic and nonperimesencephalic nonaneurysmal subarachnoid hemorrhage (PM-naSAH and NPM-naSAH) have a different bleeding pattern and clinical course. The etiology and risk factors for PM-naSAH and NPM-naSAH are unclear. The objective of this study was to compare risk factors and triggering events between PM-naSAH and NPM-naSAH. METHODS: We reviewed retrospectively all patients (n = 3475) who had undergone cerebral digital subtraction angiography between 2003 and 2020 at our tertiary hospital. Of these, 119 patients had 6-vessel angiography negative subarachnoid hemorrhage (47 (39%) PM-naSAH and 72 (61%) NPM-naSAH) and accurate information about the triggering event was available in 42 (89%) PM-NASAH and 64 (89%) NPM-naSAH patients. RESULTS: PM-naSAH were younger compared to NPM-naSAH (mean age [SD]; 55.3 [11.1] years vs. 59.6 [12.2] years, p = .045. PM-naSAH was triggered during the physical exertion in 79% of patients and 16% of patients with NPM-naSAH (relative risk 5.4; 95% CI, 2.9-10.1, p < .0001). There were no significant difference in sex, smoking, alcohol abuse, hypertension, diabetes, hyperlipidemia, or anticoagulation/antithrombotic usage between PM-naSAH and NMP-naSAH, p > .05. CONCLUSION: Physical exertion was a triggering factor in most of the PM-naSAH cases and the risk was five times greater than in NMP-naSAH. More studies are needed to confirm our results and to study pathophysiology of PM-naSAH and NPM-naSAH.


Assuntos
Hemorragia Subaracnóidea , Anticoagulantes , Criança , Fibrinolíticos , Humanos , Esforço Físico , Estudos Retrospectivos , Fatores de Risco , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/epidemiologia , Hemorragia Subaracnóidea/etiologia
6.
J Neurointerv Surg ; 14(7): 699-703, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34266906

RESUMO

BACKGROUND: Flow diversion of acutely ruptured intracranial aneurysms (IAs) is controversial due to high treatment-related complication rates and a lack of supporting evidence. We present clinical and radiological results of the largest series to date. METHODS: This is a nationwide retrospective study of acutely ruptured IAs treated with flow diverters (FDs). The primary outcome was the modified Rankin Scale (mRS) score at the last available follow-up time. Secondary outcomes were treatment-related complications and the aneurysm occlusion rate. RESULTS: 110 patients (64 females; mean age 55.7 years; range 12-82 years) with acutely ruptured IAs were treated with FDs between 2012 and 2020 in five centers. 70 acutely ruptured IAs (64%) were located in anterior circulation, and 47 acutely ruptured IAs (43%) were blister-like. A favorable functional outcome (mRS 0-2) was seen in 73% of patients (74/102). Treatment-related complications were seen in 45% of patients (n=49). Rebleeding was observed in 3 patients (3%). The data from radiological follow-ups were available for 80% of patients (n=88), and complete occlusion was seen in 90% of aneurysms (79/88). The data from clinical follow-ups were available for 93% of patients (n=102). The overall mortality rate was 18% (18/102). CONCLUSIONS: FD treatment yields high occlusion for acutely ruptured IAs but is associated with a high risk of complications. Considering the high mortality rate of aneurysmal subarachnoid hemorrhage, the prevention of rebleeding is crucial. Thus, FD treatment may be justified as a last resort option.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Hemorragia Subaracnóidea , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Criança , Embolização Terapêutica/métodos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Feminino , Finlândia , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Pessoa de Meia-Idade , Estudos Retrospectivos , Hemorragia Subaracnóidea/terapia , Resultado do Tratamento , Adulto Jovem
7.
Acta Radiol Open ; 8(9): 2058460119872404, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31516735

RESUMO

Extradural internal carotid artery aneurysms are rare and the indications for treatment are not well defined. We report successful management of two high extradural internal carotid artery aneurysms treated with flow diverter stents. The endovascular repair of extradural internal carotid artery aneurysms is effective because with surgical treatment there is always the possibility of cranial nerve injury.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA