Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Mol Diagn ; 25(10): 740-747, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37474002

RESUMO

An epidemic caused by an outbreak of mpox (formerly monkeypox) in May 2022 rapidly spread internationally, requiring an urgent response from the clinical diagnostics community. A detailed description of the clinical validation and implementation of a laboratory-developed real-time PCR test for detecting nonvariola Orthopoxvirus-specific DNA based on the newly designed RealStar Zoonotic Orthopoxvirus assay is presented. The validation was performed using an accuracy panel (n = 97) comprising skin lesion swabs in universal transport media and from mpox virus genomic DNA spiked into pooled mpox virus-negative remnant universal transport media of lesion specimens submitted for routine clinical testing in the NewYork-Presbyterian Hospital clinical laboratory system. Accuracy testing demonstrated excellent assay agreement between expected and observed results and comparable diagnostic performance to three different reference tests. Analytical sensitivity with 95% detection probability was 126 copies/mL, and analytical specificity, clinical sensitivity, and clinical specificity were 100%. In summary, the RealStar Zoonotic Orthopoxvirus assay provides a sensitive and reliable method for routine diagnosis of mpox infections.


Assuntos
Doenças Transmissíveis , Mpox , Orthopoxvirus , Humanos , Orthopoxvirus/genética , Mpox/diagnóstico , Mpox/epidemiologia , Sensibilidade e Especificidade , Reação em Cadeia da Polimerase em Tempo Real/métodos , DNA Viral/genética
2.
J Mol Diagn ; 23(2): 149-158, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33285285

RESUMO

An epidemic caused by an outbreak of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in China in December 2019 has since rapidly spread internationally, requiring urgent response from the clinical diagnostics community. We present a detailed overview of the clinical validation and implementation of the first laboratory-developed real-time RT-PCR test offered in the NewYork-Presbyterian Hospital system following the Emergency Use Authorization issued by the US Food and Drug Administration. Nasopharyngeal and sputum specimens (n = 174) were validated using newly designed dual-target real-time RT-PCR (altona RealStar SARS-CoV-2 Reagent) for detecting SARS-CoV-2 in upper respiratory tract and lower respiratory tract specimens. Accuracy testing demonstrated excellent assay agreement between expected and observed values and comparable diagnostic performance to reference tests. The limit of detection was 2.7 and 23.0 gene copies per reaction for nasopharyngeal and sputum specimens, respectively. Retrospective analysis of 1694 upper respiratory tract specimens from 1571 patients revealed increased positivity in older patients and males compared with females, and an increasing positivity rate from approximately 20% at the start of testing to 50% at the end of testing 3 weeks later. Herein, we demonstrate that the assay accurately and sensitively identifies SARS-CoV-2 in multiple specimen types in the clinical setting and summarize clinical data from early in the epidemic in New York City.


Assuntos
Academias e Institutos , Teste para COVID-19 , COVID-19/diagnóstico , COVID-19/virologia , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bioensaio , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Lactente , Recém-Nascido , Limite de Detecção , Masculino , Pessoa de Meia-Idade , Nasofaringe/virologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Escarro/virologia , Adulto Jovem
3.
bioRxiv ; 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32511352

RESUMO

The Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) has caused thousands of deaths worldwide, including >18,000 in New York City (NYC) alone. The sudden emergence of this pandemic has highlighted a pressing clinical need for rapid, scalable diagnostics that can detect infection, interrogate strain evolution, and identify novel patient biomarkers. To address these challenges, we designed a fast (30-minute) colorimetric test (LAMP) for SARS-CoV-2 infection from naso/oropharyngeal swabs, plus a large-scale shotgun metatranscriptomics platform (total-RNA-seq) for host, bacterial, and viral profiling. We applied both technologies across 857 SARS-CoV-2 clinical specimens and 86 NYC subway samples, providing a broad molecular portrait of the COVID-19 NYC outbreak. Our results define new features of SARS-CoV-2 evolution, nominate a novel, NYC-enriched viral subclade, reveal specific host responses in interferon, ACE, hematological, and olfaction pathways, and examine risks associated with use of ACE inhibitors and angiotensin receptor blockers. Together, these findings have immediate applications to SARS-CoV-2 diagnostics, public health, and new therapeutic targets.

4.
Diagn Microbiol Infect Dis ; 90(4): 257-263, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29433999

RESUMO

This study evaluated the performance of the Altona Diagnostics RealStar® Adenovirus Research Use Only (RUO) real-time PCR reagents for HAdV quantitation in plasma samples from immunodeficient patients. The assay was linear from 2.30-9.17 log10 copies/mL (coefficient of determination; R2=0.998) with limits of detection and quantification of 2.19 log10 and 2.30 log10 copies/mL (>95% positivity rate), respectively. Assay precision was highly reproducible with coefficients of variance ranging from 0% to 4.7%. A comparison of 66 matched samples showed good agreement (R2=0.845) between the Altona and the reference laboratory assay, with an average negative bias (-0.24 log10 copies/mL). Genotyping analysis demonstrated that HAdV species B and C accounted for 77% of the positive samples. A significant (≥0.9 log10) difference in quantitation between both tests was found for three HAdV types (HAdV types A12, B14 and F41). In conclusion, the Altona RealStar® test is a reliable and sensitive assay for HAdV DNA quantitation.


Assuntos
Infecções por Adenovirus Humanos/virologia , Adenovírus Humanos/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Carga Viral/métodos , Adenovírus Humanos/genética , Humanos , Plasma/virologia , Estudos Prospectivos , Reprodutibilidade dos Testes
5.
Am J Clin Pathol ; 144(6): 909-15, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26572998

RESUMO

OBJECTIVES: Viral load testing for BK virus (BKV) has become the standard of care for diagnosing BKV infection and monitoring therapy in kidney transplant patients. However, there are currently no US Food and Drug Administration-approved assays and no standardization among available tests. METHODS: This study evaluated the performance of the analyte-specific reagent (ASR) BKV primers r-gene and probe r-gene reagents (bioMérieux, Marcy l'Étoile, France) soon to become available on the US market for accuracy, linearity, precision, analytical sensitivity, specificity, and correlation with the Qiagen (Germantown, MD) BKV ASR test using commercial material and patient plasma samples. RESULTS: The assay was linear from 204 to 3.92 million (2.31-6.6 log10) DNA copies/mL (coefficient of determination: R(2) =0.999). A dilution series demonstrated limits of detection and quantitation of 2.14 log10 and 2.30 log10 copies/mL (95% hit rate detection), respectively. Interrun precision was highly reproducible, with coefficients of variance ranging from 2.2% to 6.0%. A comparison of 34 matched samples showed a good agreement (R(2) = 0.87) between the bioMérieux BKV laboratory test and the Qiagen BKV ASR assay results, with an average negative bias (-0.28 log10 copies/mL). CONCLUSIONS: The laboratory-developed test with bioMérieux BKV reagents is a reliable and sensitive assay for BKV DNA quantitation compared with the Qiagen ASR test.


Assuntos
Vírus BK , DNA Viral/sangue , Infecções por Polyomavirus/diagnóstico , Humanos , Indicadores e Reagentes , Sensibilidade e Especificidade , Infecções Tumorais por Vírus/diagnóstico
6.
J Acquir Immune Defic Syndr ; 63(1): 9-16, 2013 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-23274935

RESUMO

OBJECTIVE: We sought to develop a score to predict sustained virological response (SVR) in racially diverse HIV/hepatitis C virus (HCV)-coinfected and HCV-monoinfected pegylated interferon/ribavirin-treated patients. METHODS: We retrospectively evaluated 374 patients (259 monoinfected and 115 coinfected) treated at a single tertiary care center. The IL28B rs12979860 single nucleotide polymorphism genotyping was performed in 335 patients, and plasma CXCL10 levels were measured by enzyme-linked immunosorbent assay in 171 patients. RESULTS: Of the 374 patients, 64.9% were white, 17.2% were African American, 76.5% were HCV genotype 1 infected, and 49.3% had advanced fibrosis. Sustained virological response was achieved by 151 (40.4%) patients, 106 (40.9%) patients monoinfected, and 45 (39.1%) patients coinfected. Patients with IL28B C/C genotype were significantly more likely to achieve an SVR compared with non-C/C genotype patients, but only if they were infected with HCV genotypes 1/4 (59.1% vs 21.1%, P < 0.0001). No significant differences existed in IL28B predictive capacity between coinfected and monoinfected patients. Pretreatment CXCL10 levels were significantly higher in nonresponders, both monoinfected and coinfected, compared with SVR patients (P = 0.0018). Coinfected patients had higher CXCL10 levels compared with monoinfected patients (P = 0.03). The combination of IL28B genotype, pretreatment CXCL10 and HCV RNA levels, and HCV genotype had the best ability to predict treatment response in both patient groups (area under the receiver operating characteristic curve = 0.85). Among all patients, a cutoff score of -0.94 or more had a sensitivity of 0.93 and specificity of 0.59. In coinfected patients, a score of -0.55 or more had sensitivity of 0.81 and specificity of 0.80. CONCLUSIONS: IL28B genotype, pretreatment CXCL10, and HCV RNA levels have very good capacity to predict pegylated interferon/ribavirin-treatment outcome in both HIV/HCV coinfected and HCV monoinfected patients.


Assuntos
Antivirais/uso terapêutico , Quimiocina CXCL10/sangue , Infecções por HIV/tratamento farmacológico , Hepacivirus/genética , Hepatite C/tratamento farmacológico , Interleucinas/genética , Polimorfismo de Nucleotídeo Único , RNA Viral/sangue , Adulto , Negro ou Afro-Americano , População Negra , Feminino , Genótipo , Infecções por HIV/complicações , Infecções por HIV/etnologia , Infecções por HIV/virologia , HIV-1 , Hepacivirus/fisiologia , Hepatite C/complicações , Hepatite C/etnologia , Hepatite C/virologia , Humanos , Interferons/uso terapêutico , Masculino , Pessoa de Meia-Idade , Polietilenoglicóis/uso terapêutico , Valor Preditivo dos Testes , Ribavirina/uso terapêutico , Resultado do Tratamento , Carga Viral , População Branca
7.
J Clin Virol ; 54(3): 260-4, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22494899

RESUMO

BACKGROUND: Viral load testing for BK Virus (BKV) has become the standard of care for the diagnosis of infection and monitoring of therapy of kidney transplant patients infected with BKV. However, there are currently no FDA-approved BKV quantification assays and no standardization among available tests. OBJECTIVE AND STUDY DESIGN: This study evaluated the performance of the Artus BK Virus RG PCR (RUO) assay (QIAGEN) for accuracy, linearity, precision, analytical sensitivity, specificity, and correlation with a referral laboratory test in patient samples. RESULTS: Linear regression analysis of the quantitative results demonstrated a linear range of quantification from 192 to 194 million (2.28 to 8.29 log(10)) DNA copies/mL and a coefficient of determination (R(2)) of 0.994. A dilution series demonstrated a limit of detection and a limit of quantification of 2.00 log(10), and 2.30 log(10) copies/mL (>95% positivity rate), respectively. The precision of the assay was highly reproducible among runs with coefficients of variance (CV) ranging from 0.2% to 7.0%. A comparison of 34 matched samples showed a good agreement (R(2)=0.983) between the Artus BK test and the referral laboratory results, with an average positive bias (0.39 log(10) copies/mL). Genotyping analysis using large-T antigen sequences demonstrated that 90% of the positive samples were BKV type I, and that there was no significant difference in quantification between the referral laboratory and Artus BK Virus tests. CONCLUSIONS: The Artus BK Virus RG PCR test is a reliable and sensitive assay for BKV DNA quantification as compared to the referral laboratory test.


Assuntos
Vírus BK/genética , Vírus BK/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Carga Viral/métodos , Monitoramento de Medicamentos/métodos , Humanos , Transplante de Rim/efeitos adversos , Infecções por Polyomavirus/diagnóstico , Infecções por Polyomavirus/virologia , Sensibilidade e Especificidade
8.
J Clin Virol ; 50(2): 100-3, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21145783

RESUMO

BACKGROUND: Quantitative HCV RNA testing is considered standard of care for monitoring during treatment of patients infected with HCV. The COBAS(®) AmpliPrep/COBAS(®) TaqMan(®) HCV Test fully automates specimen processing and reaction assembly for HCV viral load testing using reverse transcription and real-time PCR amplification. OBJECTIVES: The performance of the COBAS(®) AmpliPrep/COBAS(®) TaqMan(®) HCV Test was evaluated in a multi-center study. STUDY DESIGN: Typical plasma based specimens were tested for accuracy, analytic range of measurement, reproducibility and genotype specific quantitation. RESULTS: Linear regression analysis of the quantitative results demonstrated a linear range of detection from 50 to 5 million (1.7-6.7 log(10))IU/mL and a coefficient of determination (R(2)) of 0.9948. The precision of the assay was highly reproducible within and between runs and among laboratories with coefficients of variance (CV) ranging from 6.7% to 40.0% across the seven laboratories. A representative sample for each of the six major HCV genotypes demonstrated reproducible quantitation between the seven laboratories. CONCLUSIONS: The COBAS(®) AmpliPrep/COBAS(®) TaqMan(®) HCV Test is a reliable and sensitive assay for HCV RNA quantitation.


Assuntos
Hepacivirus/isolamento & purificação , RNA Viral/sangue , Reação em Cadeia da Polimerase Via Transcriptase Reversa/instrumentação , Genótipo , Hepacivirus/genética , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Jpn J Cancer Res ; 93(2): 151-6, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11856478

RESUMO

The significance of urokinase-type plasminogen activator (uPA) expression in gastric cancer development was tested by using a human uPA cDNA transfection approach and an in vivo severe combined immunodeficient (SCID) mouse model. The AGS gastric cancer cell line, which has urokinase-type plasminogen-activator receptor (uPAR) but lacks uPA, was transfected with a plasmid containing human uPA cDNA and injected into the backs of SCID mice. Compared with the parent AGS cells, uPA protein secretion in AGS-2-, AGS-4-, and AGS-8-transfected cells increased by 26.1-, 34.6-, and 4.8-fold, respectively (P < 0.05). mRNA expression levels of uPA in the AGS-4 clone were much stronger than those in AGS-2 and AGS-8 clones. After the cancer cells (2 x 10(6)) were injected s.c. into the SCID mice, a palpable mass was observed at the injection site at around 140 days post-injection, followed by accelerated growth of the xenograft up to 180 days post-injection only in the high uPA-producing clone (AGS-4). These results suggest that continuous and high production of uPA by tumor cells is one of the important factors reflecting the malignancy of gastric cancer cells.


Assuntos
Neoplasias Gástricas/enzimologia , Ativador de Plasminogênio Tipo Uroquinase/biossíntese , Animais , Humanos , Imuno-Histoquímica , Camundongos , Camundongos SCID , Neoplasias Gástricas/patologia , Transfecção , Células Tumorais Cultivadas , Ativador de Plasminogênio Tipo Uroquinase/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA