Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Cardiovasc Magn Reson ; 14: 10, 2012 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-22293146

RESUMO

BACKGROUND: T2-weighted cardiovascular magnetic resonance (CMR) has been shown to be a promising technique for determination of ischemic myocardium, referred to as myocardium at risk (MaR), after an acute coronary event. Quantification of MaR in T2-weighted CMR has been proposed to be performed by manual delineation or the threshold methods of two standard deviations from remote (2SD), full width half maximum intensity (FWHM) or Otsu. However, manual delineation is subjective and threshold methods have inherent limitations related to threshold definition and lack of a priori information about cardiac anatomy and physiology. Therefore, the aim of this study was to develop an automatic segmentation algorithm for quantification of MaR using anatomical a priori information. METHODS: Forty-seven patients with first-time acute ST-elevation myocardial infarction underwent T2-weighted CMR within 1 week after admission. Endocardial and epicardial borders of the left ventricle, as well as the hyper enhanced MaR regions were manually delineated by experienced observers and used as reference method. A new automatic segmentation algorithm, called Segment MaR, defines the MaR region as the continuous region most probable of being MaR, by estimating the intensities of normal myocardium and MaR with an expectation maximization algorithm and restricting the MaR region by an a priori model of the maximal extent for the user defined culprit artery. The segmentation by Segment MaR was compared against inter observer variability of manual delineation and the threshold methods of 2SD, FWHM and Otsu. RESULTS: MaR was 32.9 ± 10.9% of left ventricular mass (LVM) when assessed by the reference observer and 31.0 ± 8.8% of LVM assessed by Segment MaR. The bias and correlation was, -1.9 ± 6.4% of LVM, R = 0.81 (p < 0.001) for Segment MaR, -2.3 ± 4.9%, R = 0.91 (p < 0.001) for inter observer variability of manual delineation, -7.7 ± 11.4%, R = 0.38 (p = 0.008) for 2SD, -21.0 ± 9.9%, R = 0.41 (p = 0.004) for FWHM, and 5.3 ± 9.6%, R = 0.47 (p < 0.001) for Otsu. CONCLUSIONS: There is a good agreement between automatic Segment MaR and manually assessed MaR in T2-weighted CMR. Thus, the proposed algorithm seems to be a promising, objective method for standardized MaR quantification in T2-weighted CMR.


Assuntos
Algoritmos , Automação Laboratorial/métodos , Endocárdio/patologia , Ventrículos do Coração/patologia , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Miocárdio/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
2.
Ann Noninvasive Electrocardiol ; 15(2): 124-9, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20522052

RESUMO

BACKGROUND: The knowledge of the case-specific normal QRS duration in each individual is needed when determining the onset, severity and progression of the heart disease. However, large interindividual variability even of the normal QRS duration exists. The aims of the study were to develop a model for prediction of normal QRS complex duration and to test it on healthy individuals. METHODS: The study population of healthy adult volunteers was divided into a sample for development of a prediction model (n = 63) and a testing sample (n = 30). Magnetic resonance imaging data were used to assess anatomical characteristics of the left ventricle: the angle between papillary muscles (PM(A)), the length of the left ventricle (LV(L)) and left ventricular mass (LV(M)). Twelve-lead electrocardiogram (ECG) was used for measurement of the QRS duration. Multiple linear regression analysis was used to develop a prediction model to estimate the QRS duration. The accuracy of the prediction model was assessed by comparing predicted with measured QRS duration in the test set. RESULTS: The angle between PM(A) and the length of the LV(L) were statistically significant predictors of QRS duration. Correlation between QRS duration and PM(A) and LV(L) was r = 0.57, P = 0.0001 and r = 0.45, P = 0.0002, respectively. The final model for prediction of the QRS was: QRS(Predicted)= 97 + (0.35 x LV(L)) - (0.45 x PM(A)). The predicted and real QRS duration differed with median 1 ms. CONCLUSIONS: The model for prediction of QRS duration opens the ability to predict case-specific normal QRS duration. This knowledge can have clinical importance, when determining the normality on case-specific basis.


Assuntos
Eletrocardiografia/métodos , Eletrocardiografia/estatística & dados numéricos , Ventrículos do Coração/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Adulto , Volume Cardíaco , Feminino , Humanos , Masculino , Modelos Biológicos , Valor Preditivo dos Testes , Valores de Referência , Reprodutibilidade dos Testes
3.
BMC Med Imaging ; 10: 1, 2010 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-20064248

RESUMO

BACKGROUND: Commercially available software for cardiovascular image analysis often has limited functionality and frequently lacks the careful validation that is required for clinical studies. We have already implemented a cardiovascular image analysis software package and released it as freeware for the research community. However, it was distributed as a stand-alone application and other researchers could not extend it by writing their own custom image analysis algorithms. We believe that the work required to make a clinically applicable prototype can be reduced by making the software extensible, so that researchers can develop their own modules or improvements. Such an initiative might then serve as a bridge between image analysis research and cardiovascular research. The aim of this article is therefore to present the design and validation of a cardiovascular image analysis software package (Segment) and to announce its release in a source code format. RESULTS: Segment can be used for image analysis in magnetic resonance imaging (MRI), computed tomography (CT), single photon emission computed tomography (SPECT) and positron emission tomography (PET). Some of its main features include loading of DICOM images from all major scanner vendors, simultaneous display of multiple image stacks and plane intersections, automated segmentation of the left ventricle, quantification of MRI flow, tools for manual and general object segmentation, quantitative regional wall motion analysis, myocardial viability analysis and image fusion tools. Here we present an overview of the validation results and validation procedures for the functionality of the software. We describe a technique to ensure continued accuracy and validity of the software by implementing and using a test script that tests the functionality of the software and validates the output. The software has been made freely available for research purposes in a source code format on the project home page http://segment.heiberg.se. CONCLUSIONS: Segment is a well-validated comprehensive software package for cardiovascular image analysis. It is freely available for research purposes provided that relevant original research publications related to the software are cited.


Assuntos
Algoritmos , Doenças Cardiovasculares/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Linguagens de Programação , Design de Software , Validação de Programas de Computador , Aumento da Imagem/métodos , Internet , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA