Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Catheter Cardiovasc Interv ; 92(2): 302-309, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29027737

RESUMO

OBJECTIVES: The aim of the study was to capture the evolution of neointima after implantation of a biodegradable polymer-coated, sirolimus-eluting, cobalt-chromium coronary stent system (BP-DES). BACKGROUND: Optical coherence tomography (OCT) suggests that in-stent neointimal morphology influences clinical outcomes after DES implantation. METHODS: Sixty patients treated with single BP-DES implantation were examined by quantitative coronary angiography (QCA) and OCT at 3, 6, and 12-month follow-up. RESULTS: Median late lumen loss by QCA (mm) was 0.04 (IQR 0, 0.08), 0.17 (IQR 0, 0.32), and 0.14 (IQR 0.07, 0.31) at 3, 6, and 12-month follow-up respectively (P = 0.03). OCT cross-section multilevel analysis showed uncovered struts in 3.90%, 1.78%, and 0.02% of struts respectively (P = 0.03). The corresponding malapposition rates were 0.12%, 0.04%, and 0%. Lipid-rich neointima was observed only at 12-month follow-up in one restenotic lesion (0.77% cross-sections) that was accountable for the only target vessel revascularization. The homogeneous pattern was prevalent at all three time points, but its incidence displayed an upward trend (3 months: 59%; 6 months: 71%; 12 months: 88%) despite no difference in neointimal volume between 6 and 12 months. Conversely, a trend could be observed of decreasing incidence of heterogeneous pattern as the follow-up length increased. CONCLUSIONS: In this study of a single-type BP-DES, the majority of stent struts were covered within 3 months from implantation. While the quantitative neointimal accumulation plateaued at 6 months with no further significant increase beyond 6 months, the neointima continued to evolve qualitatively and mature along with better strut coverage between 6 and 12 months after implantation.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/cirurgia , Stents Farmacológicos , Neointima , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Tomografia de Coerência Óptica , Idoso , Fármacos Cardiovasculares/efeitos adversos , Ligas de Cromo , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Polônia , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
2.
Kardiol Pol ; 67(3): 326-9; discussion 330, 2009 Mar.
Artigo em Polonês | MEDLINE | ID: mdl-19378243

RESUMO

A 51-year-old female two years after CABG presented with unstable angina and inferior wall ischaemia. Coronary angiography revealed occluded graft to RCA and chronic total occlusion of RCA with good collateral flow from distal LAD to RCA. The CTO was successfully crossed and dilated through epicardial collaterals from distal LAD (retrograde approach). Finally, antegrade angioplasty with two stents implantation was performed achieving TIMI 3 flow.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/métodos , Oclusão Coronária/etiologia , Oclusão Coronária/terapia , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Vasos Coronários/cirurgia , Angina Instável/etiologia , Doença Crônica , Angiografia Coronária , Vasos Coronários/patologia , Ecocardiografia Doppler em Cores , Feminino , Humanos , Pessoa de Meia-Idade , Isquemia Miocárdica/etiologia
3.
Kardiochir Torakochirurgia Pol ; 12(3): 242-5, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26702281

RESUMO

We present a case of a 64-year-old man with coronary artery disease, who underwent a percutaneous coronary intervention of the circumflex artery. As the guidewire was being withdrawn from the target vessel, it became entrapped by the structure of the previously implanted stent. Attempts to retrieve the foreign body were unsuccessful. Changes in electrocardiogram were observed during the procedure, and the level of cardiac biomarkers increased within the next 24-hours. The patient was admitted to the Cardiac Surgery Department. Remnants of the foreign body were removed under visual control using extracorporeal circulation, and coronary artery bypass grafting was performed. Treatment options and outcomes are discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA