Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Undersea Hyperb Med ; 48(1): 33-42, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33648031

RESUMO

Introduction: This study aimed to assess the capability of a pulse CO-oximeter to continuously monitor carboxyhemoglobin (COHb) during hyperbaric oxygen (HBO2) therapy. We estimated limits of agreement (LOA) between blood gas analysis and pulse CO-oximeter for COHb during HBO2 therapy in patients suffering from acute CO poisoning. Furthermore, we did a medicotechnical evaluation of the pulse CO-oximeter in hyperbaric conditions. Methods: We conducted a prospective, non-clinical, observational study in which we included n=10 patients with acute CO poisoning referred for HBO2 therapy. We did five repeated measurements of COHb for each patient during the HBO2 therapy. Bland-Altman analysis for multiple observations per individual was used to assess the agreement. The a priori LOA was ±6% for COHb. For the medicotechnical evaluation continuous measurements were obtained throughout each complete HBO2 therapy. The measurements were visually inspected and evaluated. Results: The Bland-Altman analysis showed that the pulse CO-oximeter overestimated COHb by 2.9 % [±1.0%] and the LOA was ±7.3% [±1.8%]. The continuous measurements by pulse CO-oximetry showed fluctuating levels of COHb and summarized saturations reached levels above 100%. Measurements were not affected by changes in pressure. Conclusion: To our knowledge, this study is the first to assess LOA and demonstrate use of a non-invasive method to measure COHb during HBO2 therapy. The pulse CO-oximeter performed within the manufactures reported LOA (±6%) despite hyperbaric conditions and was unaffected by changes in pressure. However, summarized saturations reached levels above 100%.


Assuntos
Intoxicação por Monóxido de Carbono/sangue , Intoxicação por Monóxido de Carbono/terapia , Carboxihemoglobina/análise , Oxigenoterapia Hiperbárica , Oximetria/instrumentação , Adulto , Gasometria , Dinamarca , Feminino , Meia-Vida , Humanos , Masculino , Oximetria/métodos , Estudos Prospectivos , Pigmentação da Pele
2.
Diagn Microbiol Infect Dis ; 110(4): 116537, 2024 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-39298934

RESUMO

We examined the added value of perineal swabs in addition to nose and throat swabs when screening for Methicillin-resistant Staphylococcus aureus colonization, and risk factors for perineal carriage in 6,642 patients. In our mainly primary care setting, the added value was 9.3%. Patients <3 or ≥80 had the highest risk.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA