Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Acta Orthop ; 95: 114-120, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38353549

RESUMO

BACKGROUND AND PURPOSE: Patients actively smoking at the time of primary hip or knee arthroplasty are at increased risk of direct perioperative complications. We investigated the association between smoking status and risk of revision and mortality within 2 years following hip or knee arthroplasty. METHODS: We used prospectively collected data from the Dutch Arthroplasty Register. All primary total hip arthroplasties (THAs), total knee arthroplasties (TKAs), and unicondylar knee arthroplasties (UKAs) with > 2 years' follow-up were included (THA: n = 140,336; TKA: n = 117,497; UKA: n = 14,807). We performed multivariable Cox regression analyses to calculate hazard risks for differences between smokers and non-smokers, while adjusting for confounders (aHR). RESULTS: The smoking group had higher risk of revision (THA: aHR 1.3, 95% confidence interval [CI] 1.1-1.4 and TKA: aHR 1.4, CI 1.3-1.6) and risk of mortality (THA: aHR 1.4, CI 1.3-1.6 and TKA: aHR 1.4, CI 1.2-1.6). Following UKA, smokers had a higher risk of mortality (aHR 1.7, CI 1.0-2.8), but no differences in risk of revision were observed. The smoking group had a higher risk of revision for infection following TKA (aHR 1.3, CI 1.0-1.6), but not following THA (aHR 1.0, CI 0.8-1.2). CONCLUSION: This study showed that the risk of revision and mortality is higher for smokers than for non-smokers in the first 2 years following THA and TKA. Smoking could contribute to complications following primary hip or knee arthroplasty.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Estudos de Coortes , Fumar/efeitos adversos , Fumar/epidemiologia , Artroplastia de Quadril/efeitos adversos , Sistema de Registros , Reoperação , Fatores de Risco
2.
Sensors (Basel) ; 23(4)2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36850597

RESUMO

Different methods exist to select strides that represent preferred, steady-state gait. The aim of this study was to identify the effect of different stride-selection methods on spatiotemporal gait parameters to analyze steady-state gait. A total of 191 patients with hip or knee osteoarthritis (aged 38-85) wearing inertial sensors walked back and forth over 10 m for two minutes. After the removal of strides in turns, five stride-selection methods were compared: (ALL) include all strides, others removed (REFERENCE) two strides around turns, (ONE) one stride around turns, (LENGTH) strides <63% of median stride length, and (SPEED) strides that fall outside the 95% confidence interval of gait speed over the strides included in REFERENCE. Means and SDs of gait parameters were compared for each trial against the most conservative definition (REFERENCE). ONE and SPEED definitions resulted in similar means and SDs compared to REFERENCE, while ALL and LENGTH definitions resulted in substantially higher SDs of all gait parameters. An in-depth analysis of individual strides showed that the first two strides after and last two strides before a turn were significantly different from steady-state walking. Therefore, it is suggested to exclude the first two strides around turns to assess steady-state gait.


Assuntos
Osteoartrite do Quadril , Osteoartrite do Joelho , Humanos , Marcha , Caminhada , Velocidade de Caminhada
3.
Arch Orthop Trauma Surg ; 143(9): 5945-5955, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36806987

RESUMO

INTRODUCTION: Low-grade femoral defects in revision total hip arthroplasty (rTHA) might be preferably treated with a primary implant. Almost no previous study reported the use of standard-length conical tapered (SLCT) stems in these cases. We analyzed a series of cases using a SLCT stem in rTHA with Paprosky type I-II femoral defects. The purpose of the study was to determine clinical and radiographic outcomes in this series of rTHA. MATERIALS AND METHODS: We prospectively followed 87 patients undergoing a femoral component rTHA: 53 Paprosky type I and 34 type II femoral defects. Patient-reported measures (Oxford Hip Score, EQ-5D, VAS pain during rest and activity) were administered at baseline, 1 and 2 years post-operatively. Radiographic subsidence overtime was scored. Kaplan-Meier curves were used to evaluate the subsidence over time, the complication-free survival, and the implant survivorship with reoperation and stem revision as endpoints. RESULTS: The mean follow-up was 72.5 (SD ± 23.9) months. All PROMs significatively improved over time. The average subsidence was 2.8 (SD ± 3.2), 3.6 (SD ± 4.4), and 4.0 (SD ± 4.9) mm at 4, 12, and 24 months respectively. 6 stems had subsidence > 10 mm. The survival without complication was 0.85 (95% CI 0.94-0.77), while the implant survival without reoperation was 0.83 (95% CI 0.95-0.72). The overall stem survival rate was 93.7% (95% CI 0.91-0.97) at 2 years. CONCLUSION: The use of a SLCT stem in rTHA with Paprosky type I-II femoral defects demonstrated good survival with low subsidence rates during the first 2 years after surgery. Surgeons should consider the use of this primary prosthesis as a potential treatment during stem revision in cases with limited femoral bone loss.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Estudos Prospectivos , Desenho de Prótese , Estudos Retrospectivos , Reoperação , Fêmur/cirurgia , Falha de Prótese , Resultado do Tratamento
4.
J Arthroplasty ; 37(11): 2239-2246, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35537612

RESUMO

BACKGROUND: In the revisions for Paprosky type II femoral defects, diaphyseal fixating femoral stems are commonly used. To preserve bone stock, the use of a shorter primary conical stem could be an adequate alternative. The objective of this study is to compare the results of a primary conical stem to the more commonly used diaphyseal fixating modular revision stem in revision total hip arthroplasty surgery with Paprosky type II femoral defects. METHODS: A total of 59 consecutive patients with Paprosky type II femoral defects from our prospective revision registry were included. Thirty patients who received a long distal fixating modular stem (Revision Stem, Lima Corporate) and 29 patients who received a primary conical short stem (Wagner Cone, Zimmer) were prospectively followed. Minimal follow-up time was 2 years for subsidence and patient-reported outcome measures and 5 years for complications, reoperation, and revision. We compared subsidence, perioperative complications, reoperations, femoral component survival, Oxford Hip Score, EuroQol 5 Dimension, visual analog scale (VAS) for pain at rest, and VAS for pain during activity between stems. RESULTS: Both groups were comparable regarding demographic, clinical, and surgery-related characteristics. We found more perioperative complications and stem revisions with the modular revision stem than with the primary conical stem. There were no statistical differences in subsidence, EuroQol 5 Dimension, Oxford Hip Score, and VAS for pain at rest or during activity between both stems. CONCLUSION: In revision total hip arthroplasty with Paprosky type II femoral defects, uncemented primary monobloc conical femoral stems showed the same clinical result as distal fixating modular stems with fewer complications and fewer stem revisions.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/métodos , Fêmur/cirurgia , Seguimentos , Humanos , Dor/cirurgia , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Reoperação/métodos , Estudos Retrospectivos
5.
J Int Neuropsychol Soc ; 27(7): 733-743, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33292899

RESUMO

OBJECTIVE: Freezing of gait (FoG) in Parkinson's disease (PD) has been associated with response inhibition. However, the relationship between response inhibition, neural dysfunction, and PD remains unclear. We assessed response inhibition and microstructural integrity of brain regions involved in response inhibition [right hemisphere inferior frontal cortex (IFC), bilateral pre-supplementary motor areas (preSMA), and subthalamic nuclei (STN)] in PD subjects with and without FoG and elderly controls. METHOD: Twenty-one people with PD and FoG (PD-FoG), 18 without FoG (PD-noFoG), and 19 age-matched controls (HC) completed a Stop-Signal Task (SST) and MRI scan. Probabilistic fiber tractography assessed structural integrity (fractional anisotropy, FA) among IFC, preSMA, and STN regions. RESULTS: Stop-signal performance did not differ between PD and HC, nor between PD-FoG and PD-noFoG. Differences in white matter integrity were observed across groups (.001 < p < .064), but were restricted to PD versus HC groups; no differences in FA were observed between PD-FoG and PD-noFoG (p > .096). Interestingly, worse FoG was associated with higher (better) mean FA in the r-preSMA, (ß = .547, p = .015). Microstructural integrity of the r-IFC, r-preSMA, and r-STN tracts correlated with stop-signal performance in HC (p ≤ .019), but not people with PD. CONCLUSION: These results do not support inefficient response inhibition in PD-FoG. Those with PD exhibited white matter loss in the response inhibition network, but this was not associated with FoG, nor with response inhibition deficits, suggesting FoG-specific neural changes may occur outside the response inhibition network. As shown previously, white matter loss was associated with response inhibition in elderly controls, suggesting PD may disturb this relationship.


Assuntos
Transtornos Neurológicos da Marcha , Doença de Parkinson , Idoso , Encéfalo/diagnóstico por imagem , Marcha , Transtornos Neurológicos da Marcha/diagnóstico por imagem , Transtornos Neurológicos da Marcha/etiologia , Humanos , Imageamento por Ressonância Magnética , Doença de Parkinson/complicações , Doença de Parkinson/diagnóstico por imagem
6.
BMC Musculoskelet Disord ; 22(1): 242, 2021 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-33658006

RESUMO

BACKGROUND: Although it is well-established that osteoarthritis (OA) impairs daily-life gait, objective gait assessments are not part of routine clinical evaluation. Wearable inertial sensors provide an easily accessible and fast way to routinely evaluate gait quality in clinical settings. However, during these assessments, more complex and meaningful aspects of daily-life gait, including turning, dual-task performance, and upper body motion, are often overlooked. The aim of this study was therefore to investigate turning, dual-task performance, and upper body motion in individuals with knee or hip OA in addition to more commonly assessed spatiotemporal gait parameters using wearable sensors. METHODS: Gait was compared between individuals with unilateral knee (n = 25) or hip OA (n = 26) scheduled for joint replacement, and healthy controls (n = 27). For 2 min, participants walked back and forth along a 6-m trajectory making 180° turns, with and without a secondary cognitive task. Gait parameters were collected using 4 inertial measurement units on the feet and trunk. To test if dual-task gait, turning, and upper body motion had added value above spatiotemporal parameters, a factor analysis was conducted. Effect sizes were computed as standardized mean difference between OA groups and healthy controls to identify parameters from these gait domains that were sensitive to knee or hip OA. RESULTS: Four independent domains of gait were obtained: speed-spatial, speed-temporal, dual-task cost, and upper body motion. Turning parameters constituted a gait domain together with cadence. From the domains that were obtained, stride length (speed-spatial) and cadence (speed-temporal) had the strongest effect sizes for both knee and hip OA. Upper body motion (lumbar sagittal range of motion), showed a strong effect size when comparing hip OA with healthy controls. Parameters reflecting dual-task cost were not sensitive to knee or hip OA. CONCLUSIONS: Besides more commonly reported spatiotemporal parameters, only upper body motion provided non-redundant and sensitive parameters representing gait adaptations in individuals with hip OA. Turning parameters were sensitive to knee and hip OA, but were not independent from speed-related gait parameters. Dual-task parameters had limited additional value for evaluating gait in knee and hip OA, although dual-task cost constituted a separate gait domain. Future steps should include testing responsiveness of these gait domains to interventions aiming to improve mobility.


Assuntos
Osteoartrite do Quadril , Osteoartrite do Joelho , Dispositivos Eletrônicos Vestíveis , Fenômenos Biomecânicos , Marcha , Humanos , Articulação do Joelho , Osteoartrite do Quadril/diagnóstico , Osteoartrite do Joelho/diagnóstico , Caminhada
7.
Acta Orthop ; 92(5): 597-601, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33988078

RESUMO

Background and purpose - From previous studies, we know that clinical outcomes of revision total knee arthroplasty (rTKA) differ among reasons for revision. Whether the prevalence of repeat rTKAs is different depending on the reason for index rTKA is unclear. Therefore, we (1) compared the repeat revision rates between the different reasons for index rTKA, and (2) evaluated whether the reason for repeat rTKA was the same as the reason for the index revision.Patients and methods - Patients (n = 8,978) who underwent an index rTKA between 2010 and 2018 as registered in the Dutch Arthroplasty Register were included. Reasons for revision, as reported by the surgeon, were categorized as: infection, loosening, malposition, instability, stiffness, patellar problems, and other. Competing risk analyses were performed to determine the cumulative repeat revision rates after an index rTKA for each reason for revision.Results - Overall, the cumulative repeat revision rate was 19% within 8 years after index rTKA. Patients revised for infection had the highest cumulative repeat revision rate (28%, 95% CI 25-32) within 8 years after index rTKA. The recurrence of the reason was more common than other reasons after index rTKA for infection (18%), instability (8%), stiffness (7%), and loosening (5%).Interpretation - Poorest outcomes were found for rTKA for infection: over 1 out of 4 infection rTKAs required another surgical intervention, mostly due to infection. Recurrence of other reasons for revision (instability, stiffness, and loosening) was also considerable. Our findings also emphasize the importance of a clear diagnosis before doing rTKA to avert second revision surgeries.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Complicações Pós-Operatórias/cirurgia , Reoperação/estatística & dados numéricos , Idoso , Dinamarca , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese
8.
Clin Orthop Relat Res ; 478(9): 2057-2064, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32023232

RESUMO

BACKGROUND: Accurate quantification of bone loss facilitates preoperative planning and standardization for research purposes in patients who undergo revision TKA. The most commonly used classification to rate bone defects in this setting, the Anderson Orthopaedic Research Institute classification, does not quantify diaphyseal bone loss and reliability has not been well studied. QUESTIONS/PURPOSES: We developed a new classification scheme to rate bone defects in patients undergoing revision TKA and tested (1) the intraobserver and interobserver reliability of this classification for revision TKA based on preoperative radiographs, and (2) whether additional CT images might improve interobserver reliability. METHODS: This was a preregistered observational study. Interobserver reliability was analyzed using preoperative radiographs of 61 patients who underwent (repeat) revision TKA, and their bone defects were rated by five experienced orthopaedic surgeons. For intraobserver reliability, ratings were repeated at least 2 weeks after the first rating (Timepoints 1 and 2). Directly after the radiographic assessments of Timepoint 2, the observers were provided with CT images of each patient and asked to rate the bone defects for a third time (Timepoint 3), to assess the additional value of CT. Intraobserver and interobserver reliability were tested using Gwet's agreement coefficient 2, which is a measure of agreement between observers in categorical data. Substantial agreement was defined as coefficients between 0.61 to 0.8 and almost perfect agreement as > 0.8. RESULTS: The intraobserver reliability varied between 0.55 (95% CI 0.40 to 0.71) and 0.87 (95% CI 0.78 to 0.96) in the epiphysis, between 0.69 (95% CI 0.58 to 0.80) and 0.98 (95% CI 0.95 to 1) in the metaphysis, and between 0.95 (95% CI 0.90 to 0.99) and 0.99 (95% CI 0.98 to 1) in the diaphysis. The interobserver reliability varied between 0.48 (95% CI 0.39 to 0.57) and 0.49 (95% CI 0.42 to 0.56) in the epiphysis and between 0.81 (95% CI 0.75 to 0.87) and 0.88 (95% CI 0.83 to 0.93) in the metaphysis, and was 0.96 (95% CI 0.93 to 0.99) in the diaphysis at Timepoint 1. The interobserver reliability at Timepoint 2 was similar to that of Timepoint 1. The addition of CT images did not improve reliability (Timepoint 3). CONCLUSIONS: The bone defect classification was less reliable in the epiphyseal area compared with the metaphysis and diaphysis. This finding may be explained by prosthetic components obscuring this region or the more severe bone defects in this region. The addition of CT scans did not improve reliability. Further testing of reliability with observers from other institutions is necessary, as well as validity testing, by testing the classification in relation to intraoperative findings. LEVEL OF EVIDENCE: Level III, diagnostic study.


Assuntos
Artroplastia do Joelho , Doenças Ósseas/classificação , Fêmur/diagnóstico por imagem , Reoperação , Tíbia/diagnóstico por imagem , Doenças Ósseas/diagnóstico por imagem , Diáfises/diagnóstico por imagem , Epífises/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Período Pré-Operatório , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
9.
J Arthroplasty ; 34(12): 3023-3029.e2, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31447256

RESUMO

BACKGROUND: The increasing prevalence of obesity has resulted in an increased number of revision total hip arthroplasties (rTHAs) performed in patients with a high body mass index (BMI). The aim of this study is to evaluate whether obesity negatively affects (1) complication rate, (2) reoperation and revision rate, and (3) patient-reported outcome in rTHA. METHODS: In this registry-based study, we prospectively followed 444 rTHAs (cup: n = 265, stem: n = 57, both: n = 122) performed in a specialized high-volume orthopedic center between 2013 and 2015. The number of complications, and reoperation and revision surgery was registered until 5 years postoperatively. Oxford Hip Score (OHS) was evaluated preoperatively, and at 1 and 2 years postoperatively. Patients were categorized based on BMI to nonobese (<30 kg/m2, n = 328), obese (30-35 kg/m2, n = 82), and severe obese (≥35 kg/m2, n = 34). RESULTS: Severe obese patients, but not obese patients, had higher risks of complications and re-revision than nonobese patients. In particular, the risk of infection following rTHA was higher in severe obese patients (24%) compared to nonobese patients (3%; relative risk, 7.7). Severe obese patients had overall poorer OHS than nonobese patients, but improvement in OHS did not differ between severe obese and nonobese patients. No differences between obese and nonobese groups on OHS were observed. CONCLUSION: In our study, severe obesity was associated with an increased risk of infection following rTHA. Patients with high BMI should be counseled appropriately before surgery.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Obesidade Mórbida/complicações , Sistema de Registros , Reoperação/estatística & dados numéricos , Infecção da Ferida Cirúrgica/etiologia , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Índice de Massa Corporal , Feminino , Humanos , Infecções , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Obesidade/complicações , Medidas de Resultados Relatados pelo Paciente , Complicações Pós-Operatórias , Estudos Prospectivos , Reoperação/efeitos adversos , Infecção da Ferida Cirúrgica/epidemiologia
10.
Mov Disord ; 30(8): 1090-7, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25641204

RESUMO

BACKGROUND: Parkinson's disease (PD) has been associated with set switching difficulty in both the motor and the cognitive domain. However, the contribution of these set switching deficits to the primary motor symptoms of the disease is unclear. We investigated whether set switching deficits contribute to gait and stepping problems in PD. By contrasting motor and cognitive set switching within the same paradigm, we investigated the nature of set switching deficits associated with freezing of gait (FOG). METHODS: We integrated step initiation with set switching within one task and compared patients with and without FOG with healthy subjects. Motor set switching was defined as a change in stepping direction from one trial to the next. Cognitive set switching was defined as a change in task rule (ie, respond according to the shape or color of the presented stimulus). RESULTS: We found delayed motor switching in PD patients with FOG. We did not observe impaired cognitive switching. CONCLUSIONS: These findings suggest that motor set switching deficits, commonly reported in tasks using verbal or tapping responses, extend to stepping and can contribute to the occurrence of freezing episodes during gait initiation.


Assuntos
Função Executiva/fisiologia , Transtornos Neurológicos da Marcha/fisiopatologia , Atividade Motora/fisiologia , Doença de Parkinson/fisiopatologia , Desempenho Psicomotor/fisiologia , Idoso , Feminino , Transtornos Neurológicos da Marcha/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/complicações
11.
Exp Brain Res ; 233(3): 1007-18, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25537466

RESUMO

After stroke, the ability to make step adjustments during walking is reduced and requires more attention, which may cause problems during community walking. The C-Mill is an innovative treadmill augmented with visual context (e.g., obstacles and stepping targets), which was designed specifically to practice gait adaptability. The objective of this study was to determine whether C-Mill gait adaptability training can help to improve gait adjustments and associated attentional demands. Sixteen community-ambulating persons in the chronic stage of stroke (age: 54.8 ± 10.8 years) received ten sessions of C-Mill training within 5-6 weeks. Prior to and after the intervention period, participants performed an obstacle-avoidance task with and without a secondary attention-demanding auditory Stroop task to assess their ability to make gait adjustments (i.e., obstacle-avoidance success rates) as well as the associated attentional demands (i.e., Stroop success rates, stratified for pre-crossing, crossing, and post-crossing strides). Obstacle-avoidance success rates improved after C-Mill training from 52.4 ± 16.3 % at pretest to 77.0 ± 16.4 % at posttest (p < 0.001). This improvement was accompanied by greater Stroop success rates during the obstacle-crossing stride only (pretest: 62.9 ± 24.9 %, posttest: 77.5 ± 20.4 %, p = 0.006). The observed improvements in obstacle-avoidance success rates and Stroop success rates were strongly correlated (r = 0.68, p = 0.015). The ability to make gait adjustments and the associated attentional demands can be successfully targeted in persons with stroke using C-Mill training, which suggests that its underlying assumptions regarding motor control are appropriate. This study lends support and guidance for designing a randomized controlled trial to further examine the potential of C-Mill training for improving safe community ambulation after stroke.


Assuntos
Adaptação Fisiológica/fisiologia , Atenção/fisiologia , Marcha/fisiologia , Reabilitação do Acidente Vascular Cerebral , Caminhada/fisiologia , Adulto , Idoso , Terapia por Exercício , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Acidente Vascular Cerebral/fisiopatologia
12.
PeerJ ; 11: e16641, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38111664

RESUMO

Background: Studies using inertial measurement units (IMUs) for gait assessment have shown promising results regarding accuracy of gait event detection and spatiotemporal parameters. However, performance of such algorithms is challenged in irregular walking patterns, such as in individuals with gait deficits. Based on the literature, we developed an algorithm to detect initial contact (IC) and terminal contact (TC) and calculate spatiotemporal gait parameters. We evaluated the validity of this algorithm for regular and irregular gait patterns against a 3D optical motion capture system (OMCS). Methods: Twenty healthy participants (aged 59 ± 12 years) and 10 people in the chronic phase after stroke (aged 61 ± 11 years) were equipped with 4 IMUs: on both feet, sternum and lower back (MTw Awinda, Xsens) and 26 reflective makers. Participants walked on an instrumented treadmill for 2 minutes (i) with their preferred stride lengths and (ii) once with irregular stride lengths (±20% deviation) induced by light projected stepping stones. Accuracy of the algorithm was evaluated on stride-by-stride agreement of IC, TC, stride time, length and velocity with OMCS. Bland-Altman-like plots were made for the spatiotemporal parameters, while differences in detection of IC and TC time instances were shown in histogram plots. Performance of the algorithm was compared between regular and irregular gait with a linear mixed model. This was done by comparing the performance in healthy participants in the regular vs irregular walking condition, and by comparing the agreement in healthy participants with stroke participants in the regular walking condition. Results: For each condition at least 1,500 strides were included for analysis. Compared to OMCS, IMU-based IC detection in both groups and condition was on average 9-17 (SD ranging from 7 to 35) ms, while IMU-based TC was on average 15-24 (SD ranging from 12 to 35) ms earlier. When comparing regular and irregular gait in healthy participants, the difference between methods was 2.5 ms higher for IC, 3.4 ms lower for TC, 0.3 cm lower for stride length, and 0.4 cm/s higher for stride velocity in the irregular walking condition. No difference was found on stride time. When comparing the differences between methods between healthy and stroke participants, the difference between methods was 7.6 ms lower for IC, 3.8 cm lower for stride length, and 3.4 cm/s lower for stride velocity in stroke participants. No differences were found on differences between methods on TC detection and stride time between stroke and healthy participants. Conclusions: Small irrelevant differences were found on gait event detection and spatiotemporal parameters due to irregular walking by imposing irregular stride lengths or pathological (stroke) gait. Furthermore, IMUs seem equally good compared to OMCS to assess gait variability based on stride time, but less accurate based on stride length.


Assuntos
Marcha , Acidente Vascular Cerebral , Humanos , Reprodutibilidade dos Testes , Caminhada , Acidente Vascular Cerebral/diagnóstico , Algoritmos
13.
Bone Jt Open ; 4(5): 338-356, 2023 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-37160269

RESUMO

To map literature on prognostic factors related to outcomes of revision total knee arthroplasty (rTKA), to identify extensively studied factors and to guide future research into what domains need further exploration. We performed a systematic literature search in MEDLINE, Embase, and Web of Science. The search string included multiple synonyms of the following keywords: "revision TKA", "outcome" and "prognostic factor". We searched for studies assessing the association between at least one prognostic factor and at least one outcome measure after rTKA surgery. Data on sample size, study design, prognostic factors, outcomes, and the direction of the association was extracted and included in an evidence map. After screening of 5,660 articles, we included 166 studies reporting prognostic factors for outcomes after rTKA, with a median sample size of 319 patients (30 to 303,867). Overall, 50% of the studies reported prospectively collected data, and 61% of the studies were performed in a single centre. In some studies, multiple associations were reported; 180 different prognostic factors were reported in these studies. The three most frequently studied prognostic factors were reason for revision (213 times), sex (125 times), and BMI (117 times). Studies focusing on functional scores and patient-reported outcome measures as prognostic factor for the outcome after surgery were limited (n = 42). The studies reported 154 different outcomes. The most commonly reported outcomes after rTKA were: re-revision (155 times), readmission (88 times), and reinfection (85 times). Only five studies included costs as outcome. Outcomes and prognostic factors that are routinely registered as part of clinical practice (e.g. BMI, sex, complications) or in (inter)national registries are studied frequently. Studies on prognostic factors, such as functional and sociodemographic status, and outcomes as healthcare costs, cognitive and mental function, and psychosocial impact are scarce, while they have been shown to be important for patients with osteoarthritis.

14.
Clin Biomech (Bristol, Avon) ; 107: 106028, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37331152

RESUMO

BACKGROUND: Due to anatomical deviations, assumptions of the conventional calibration method for gait analysis may be violated in individuals with rotational deformities of the femur. Functional calibration methods were compared with conventional methods in this group for 1) localization of the hip joint center and orientation of the knee axis, and 2) gait kinematics. METHODS: Twenty-four adolescents with idiopathic rotational deformity of the femur underwent gait analysis and a CT scan. During standing, distance between hip joint centers and knee axis orientation were compared between calibration methods, with CT serving as reference for hip joint center estimation. Gait kinematics were compared using statistical parametric mapping. FINDINGS: The conventional calibration method estimated the hip joint center closer to the CT reference (4±12 mm more lateral) than the functional calibration method (26 ± 20 mm more lateral). Orientation of the knee joint axis was 2.6° less internal in the functional calibration method. During gait, statistical parametric mapping revealed significantly more hip flexion, less external hip rotation during the swing phase, less knee varus-valgus motion, and larger knee flexion angles when applying the functional method. INTERPRETATION: Functional calibration methods were less accurate in determining the hip joint center location than the conventional calibration method and resulted in a knee joint axis that was less internally rotated. Importantly, there was less knee joint angle crosstalk during gait when using the functional method. Although differences between methods on gait kinematics were within clinically acceptable limits for the sagittal plane, relatively larger differences on transversal hip kinematics may hold clinical importance.


Assuntos
Fêmur , Marcha , Humanos , Adolescente , Fenômenos Biomecânicos , Calibragem , Amplitude de Movimento Articular , Fêmur/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Rotação
15.
J Ultrason ; 23(95): e358-e364, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38020516

RESUMO

Aim of the study: There is no consensus on the most suitable non-surgical treatment of chronic lateral elbow tendinopathy. The aim of this pilot randomized controlled trial was to evaluate the size of effect of ultrasound-guided percutaneous needle tenotomy. Material and methods: Three intervention arms were formed: 1) percutaneous needle tenotomy, hydrodissection, and physiotherapy; 2) hydrodissection and physiotherapy; and 3) physiotherapy alone. Patients with chronic lateral elbow tendinopathy were randomized. Clinical endpoints included multiple questionnaires after three months: Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH), Numeric Rating Scale (NRS) pain at rest and during activity, and EuroQol 5D-5L (EQ-5D-5L). Results: Thirty patients were included of 128 screened. The QuickDASH score improved in the percutaneous needle tenotomy and physiotherapy group, but not in the hydrodissection group. The NRS pain at rest and during activity improved more in the percutaneous needle tenotomy (resp. -2 and -2) and hydrodissection (resp. -3 and -3) groups than in the physiotherapy (resp. +1 and -1) group. The EQ-5D-5L improved similarly in all groups. Conclusions: Patients receiving percutaneous needle tenotomy and/or hydrodissection may show better results in terms of pain but not in their functional outcomes compared to those who received physiotherapy alone. The size of effect, however, is small, so a large sample size is needed for a future randomized controlled trial to further investigate these results.

16.
Clin Park Relat Disord ; 9: 100201, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37252677

RESUMO

Background: Gait and balance impairments are among the most troublesome and heterogeneous in Parkinson's disease (PD). This heterogeneity may, in part, reflect genetic variation. The apolipoprotein E (APOE) gene has three major allelic variants (ε2, ε3 and ε4). Previous work has demonstrated that older adult (OA) APOE ε4 carriers demonstrate gait deficits. This study compared gait and balance measures between APOE ε4 carriers and non-carriers in both OA and PD. Methods: 334 people with PD (81 APOE ε4 carriers and 253 non-carriers) and 144 OA (41 carriers and 103 non-carriers) were recruited. Gait and balance were assessed using body-worn inertial sensors. Two-way analyses of covariance (ANCOVA) compared gait and balance characteristics between APOE ε4 carriers and non-carriers in people with PD and OA, controlling for age, gender, and testing site. Results: Gait and balance were worse in people with PD compared to OA. However, there were no differences between APOE ε4 carriers and non-carriers in either the OA or PD group. In addition, there were no significant group (OA/PD) by APOE ε4 status (carrier/non-carrier) interaction effects for any measures of gait or balance. Conclusions: Although we found expected impairments in gait and balance in PD compared to OA, gait and balance characteristics did not differ between APOE ε4 carriers and non-carriers in either group. While APOE status did not impact gait and balance in this cross-sectional study, future work is needed to determine whether progression of gait and balance deficits is faster in PD APOE Ɛ4 carriers.

17.
Bone Joint J ; 104-B(7): 859-866, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35775171

RESUMO

AIMS: The aim of this study was to explore the relationship between reason for revision total hip arthroplasty (rTHA) and outcomes in terms of patient-reported outcome measures (PROMs). METHODS: We reviewed a prospective cohort of 647 patients undergoing full or partial rTHA at a single high-volume centre with a minimum of two years' follow-up. The reasons for revision were classified as: infection; aseptic loosening; dislocation; structural failure; and painful THA for other reasons. PROMs (modified Oxford Hip Score (mOHS), EuroQol five-dimension three-level health questionnaire (EQ-5D-3L) score, and visual analogue scales for pain during rest and activity), complication rates, and failure rates were compared among the groups. RESULTS: The indication for revision influenced PROMs improvement over time. This finding mainly reflected preoperative differences between the groups, but diminished between the first and second postoperative years. Preoperatively, patients revised due to infection and aseptic loosening had a lower mOHS than patients with other indications for revision. Pain scores at baseline were highest in patients being revised for dislocation. Infection and aseptic loosening groups showed marked changes over time in both mOHS and EQ-5D-3L. Overall complications and re-revision rates were 35.4% and 9.7% respectively, with no differences between the groups (p = 0.351 and p = 0.470, respectively). CONCLUSION: Good outcomes were generally obtained regardless of the reason for revision, with patients having the poorest preoperative scores exhibiting the greatest improvement in PROMs. Furthermore, overall complication and reoperation rates were in line with previous reports and did not differ between different indications for rTHA. Cite this article: Bone Joint J 2022;104-B(7):859-866.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/métodos , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Dor , Medidas de Resultados Relatados pelo Paciente , Falha de Prótese , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
18.
Bone Joint J ; 104-B(4): 464-471, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35360944

RESUMO

AIMS: Debridement, antibiotics, and implant retention (DAIR) is a widely accepted form of surgical treatment for patients with an early periprosthetic joint infection (PJI) after primary arthroplasty. The outcome of DAIR after revision arthroplasty, however, has not been reported. The aim of this study was to report the success rate of DAIR after revision arthroplasty with a follow-up of two years. METHODS: This retrospective study, conducted at the Sint Maartenskliniek, Nijmegen, the Netherlands, included 88 patients who underwent DAIR within 90 days of revision total hip or total knee arthroplasty between 2012 and 2019. Details of the surgical procedures and PJI were collected. Univariate analysis and a subgroup analysis of the culture-positive group were performed. Kaplan-Meier survivorship curves were constructed. RESULTS: The overall success rate of DAIR, with respect to the retention of components and the cure of infection, was 68% after two years. DAIR performed with an interval of > 30 days after the index revision procedure (odds ratio (OR) 0.24 (95% confidence interval (CI) 0.08 to 0.72); p = 0.008), a repeated DAIR within 90 days (OR 0.37 (95% CI 0.14 to 0.97); p = 0.040), and the use of an immunosuppressive agent (OR 0.13 (95% CI 0.02 to 0.67); p = 0.012) were associated with a significantly reduced success rate. In the culture-positive group, a mismatch between the antibiotic treatment and the susceptibility of the organism was associated with a significantly lower success rate (OR 0.13 (95% CI 0.03 to 0.62); p = 0.007). CONCLUSION: DAIR is an acceptable form of surgical treatment for patients with a suspected early PJI after revision arthroplasty of the hip or knee. DAIRs performed after a prolonged interval, multiple DAIRs, and antibiotic mismatches were significantly associated with an increased risk of failure. Optimization of the host immune response and the prevention of antibiotic mismatch are modifiable factors that may improve the outcome. The high rate of mismatches was an important finding, underlining the need for a review of the local microbiological data, which might improve the outcome. Cite this article: Bone Joint J 2022;104-B(4):464-471.


Assuntos
Artroplastia do Joelho , Prótese de Quadril , Infecções Relacionadas à Prótese , Antibacterianos/uso terapêutico , Artroplastia do Joelho/efeitos adversos , Desbridamento/métodos , Prótese de Quadril/efeitos adversos , Humanos , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
19.
PeerJ ; 10: e14054, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36193431

RESUMO

Background: Inertial sensors hold the promise to objectively measure functional recovery after total knee (TKA) and hip arthroplasty (THA), but their value in addition to patient-reported outcome measures (PROMs) has yet to be demonstrated. This study investigated recovery of gait after TKA and THA using inertial sensors, and compared results to recovery of self-reported scores of pain and function. Methods: PROMs and gait parameters were assessed before and at two and fifteen months after TKA (n = 24) and THA (n = 24). Gait parameters were compared with healthy individuals (n = 27) of similar age. Gait data were collected using inertial sensors on the feet, lower back, and trunk. Participants walked for two minutes back and forth over a 6m walkway with 180° turns. PROMs were obtained using the Knee Injury and Osteoarthritis Outcome Scores and Hip Disability and Osteoarthritis Outcome Score. Results: Gait parameters recovered to the level of healthy controls after both TKA and THA. Early improvements were found in gait-related trunk kinematics, while spatiotemporal gait parameters mainly improved between two and fifteen months after TKA and THA. Compared to the large and early improvements found in of PROMs, these gait parameters showed a different trajectory, with a marked discordance between the outcome of both methods at two months post-operatively. Conclusion: Sensor-derived gait parameters were responsive to TKA and THA, showing different recovery trajectories for spatiotemporal gait parameters and gait-related trunk kinematics. Fifteen months after TKA and THA, there were no remaining gait differences with respect to healthy controls. Given the discordance in recovery trajectories between gait parameters and PROMs, sensor-derived gait parameters seem to carry relevant information for evaluation of physical function that is not captured by self-reported scores.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Osteoartrite , Humanos , Artroplastia de Quadril/métodos , Artroplastia do Joelho/métodos , Articulação do Joelho , Marcha
20.
Prog Brain Res ; 269(1): 309-343, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35248200

RESUMO

Parkinson's disease (PD) is commonly treated with dopaminergic medication, which enhances some, while impairing other cognitive functions. It can even contribute to impulse control disorder and addiction. We describe the history of research supporting the dopamine overdose hypothesis, which accounts for the large within-patient variability in dopaminergic medication effects across different tasks by referring to the spatially non-uniform pattern of dopamine depletion in dorsal versus ventral striatum. However, there is tremendous variability in dopaminergic medication effects not just within patients across distinct tasks, but also across different patients. In the second part of this chapter we review recent studies addressing the large individual variability in the negative side effects of dopaminergic medication on functions that implicate dopamine, such as value-based learning and choice. These studies begin to unravel the mechanisms of dopamine overdosing, thus revising the strict version of the overdose hypothesis. For example, the work shows that the canonical boosting of reward-versus punishment-based choice by medication is greater in patients with depression and a non-tremor phenotype, which both implicate, among other pathology, more rather than less severe dysregulation of the mesolimbic dopamine system. Future longitudinal cohort studies are needed to identify how to optimally combine different clinical, personality, cognitive, neural, genetic and molecular predictors of detrimental medication effects in order to account for as much of the relevant variability as possible. This will provide a useful tool for precision neurology, allowing individual and contextual tailoring of (the dose of) dopaminergic medication in order to maximize its cognitive benefits, yet minimize its side effects.


Assuntos
Disfunção Cognitiva , Doença de Parkinson , Disfunção Cognitiva/tratamento farmacológico , Disfunção Cognitiva/etiologia , Dopamina , Dopaminérgicos/efeitos adversos , Humanos , Doença de Parkinson/complicações , Doença de Parkinson/tratamento farmacológico , Recompensa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA