J Vasc Surg ; 78(6): 1383-1391.e5, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37330151

RESUMO

OBJECTIVE: To assess the early experience with modified version of simplified bare-wire target vessel (SMART) technique, implying delivery of bridging stent grafts without historically established sheath support, and to compare its outcome to standard endovascular aortic repair procedures with fenestrated/branched devices. METHODS: A retrospective analysis of 102 consecutive patients treated with fenestrated/branched devices from January 2020 to December 2022 was undertaken. The study population was divided into three groups-a sheath group (SG), SMART group, and nonsheath group (NSG). Primary end points were radiation exposure (dose-area product), fluoroscopy time, dose of contrast agent, operation time, and incidence of intraoperative target vessel (TV) complications and additional procedures. Freedom from secondary TV related reinterventions at the three follow-up phases were defined as secondary end points. RESULTS: A total of 183 TVs (38.8% visceral arteries [VA]; 56.3% renal arteries [RA]) in the SG, 36 TVs (44.4% VA, 55.6% RA) in the SMART group, and 168 TVs (47.6% VA; 50% RA) in the NSG were accessed. The mean number of fenestrations and bridging stent grafts was equally distributed in all three groups. The SMART group only included cases treated with fenestrated devices. The dose-area product was significantly lower in the SMART (median, 203 Gy × cm2; interquartile range [IQR], 179-365 Gy × cm2) and NSG (median, 340 Gy × cm2; IQR, 220-651 Gy × cm2) groups vs the SG (median, 464 Gy × cm2; IQR, 267-871 Gy × cm2; P = .007). Operation time was also significantly lower in the NSG (median, 265 minutes; IQR, 221-337 minutes) and SMART (median, 292 minutes; IQR, 234-351 minutes) groups vs the SG (median, 326 minutes; IQR, 277-375 minutes; P = .004), respectively. Intraoperative TV-related complications were most frequently observed in the SG (9/183 TVs; P = .008). CONCLUSIONS: This study reports the outcomes of three currently available TV stenting approaches. Previously reported SMART technique, and its modified version (NSG) proved to be a safe alternative to historically established TV stenting technique with sheath support (SG).


Assuntos
Correção Endovascular de Aneurisma , Stents , Humanos , Estudos Retrospectivos , Meios de Contraste , Fluoroscopia , Complicações Intraoperatórias
2.
J Vasc Surg ; 77(5): 1359-1366.e2, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36587811

RESUMO

OBJECTIVE: Endovascular aortic repair (EVAR) with fenestrated (F-EVAR) or branched (B-EVAR) endografts represents an indispensable tool of modern patient care in vascular surgery. The purpose of this retrospective study was to evaluate the center's initial experience of F/B-EVAR procedures performed under biplane angiography guidance compared with a historical control group. METHODS: From January 2020 to March 2022, 80 consecutive patients underwent F/B-EVAR under general anesthesia at a single institution. As from January 2021, the deployment of complex stent grafts was performed using an alternative intraoperative imaging modality-a biplane fluoroscopy and angiography. The cohort was divided into monoplane (MPA) and biplane (BPA) groups according to the imaging modality applied. The end points were operation time, fluoroscopy time, radiation exposure, dose of contrast agent, and technical success. RESULTS: The MPA group included 59 patients (78% male; median age; 74 years; interquartile range [IQR], 66-78 years) and the BPA group 21 patients (85.7% males; median age, 75 years; IQR, 69-79 years). Operation time (median, 320 minutes; IQR, 266-376 minutes) versus (median, 275 minutes; IQR, 216-333 minutes) was significantly lower in the BPA group (P = .006). The median fluoroscopy time (median, 82 minutes; IQR, 57-110 minutes vs median, 68 minutes; IQR, 54-92 minutes), contrast agent volume applied (median, 220 mL; IQR, 179-250 mL vs median, 200 mL; IQR, 170-250 mL), and radiation dose (dose-area product, median, 413 Gy × cm2; IQR, 249-736 Gy × cm2; vs median, 542 Gy × cm2; IQR, 196-789 Gy × cm2) were similar in both groups. Technical success of 96.6% (57/59 cases) versus 100% (21/21 cases) could be achieved in MPA and BPA group, respectively. CONCLUSIONS: F/B-EVAR procedures performed under BPA guidance were associated with a significant decrease in operation time.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Idoso , Feminino , Meios de Contraste , Prótese Vascular , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Estudos Retrospectivos , Aortografia/efeitos adversos , Aortografia/métodos , Resultado do Tratamento , Doses de Radiação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Fluoroscopia , Aneurisma da Aorta Abdominal/cirurgia
3.
Biomedicines ; 11(5)2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37238988

RESUMO

Complex endovascular aortic repair (coEVAR) of thoracoabdominal aortic aneurysms (TAAA) has greatly evolved in the past decades. Despite substantial improvements of postoperative care, spinal cord injury (SCI) remains the most devastating complication of coEVAR being associated with impaired patient outcome and having an impact on long-term survival. The rising number of challenges of coEVAR, essentially associated with an extensive coverage of critical blood vessels supplying the spinal cord, resulted in the implementation of dedicated SCI prevention protocols. In addition to maintenance of adequate spinal cord perfusion pressure (SCPP), early detection of SCI plays an integral role in intra- and postoperative patient care. However, this is challenging due to difficulties with clinical neurological examinations during patient sedation in the postoperative setting. There is a rising amount of evidence, suggesting that subclinical forms of SCI might be accompanied by an elevation of biochemical markers, specific to neuronal tissue damage. Addressing this hypothesis, several studies have attempted to assess the potential of selected biomarkers with regard to early SCI diagnosis. In this review, we discuss biomarkers measured in patients undergoing coEVAR. Once validated in future prospective clinical studies, biomarkers of neuronal tissue damage may potentially add to the armamentarium of modalities for early SCI diagnosis and risk stratification.

4.
Free Radic Biol Med ; 206: 94-105, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37353175

RESUMO

There is accumulating evidence that pro-inflammatory features are inherent to mitochondrial DNA and oxidized DNA species. 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodGuo) is the most frequently studied oxidatively generated lesion. Modified DNA reaches the circulation upon cell apoptosis, necrosis or neutrophil extracellular trap (NET) formation. Standard chromatography-based techniques for the assessment of 8-oxodGuo imply degradation of DNA to a single base level, thus precluding the attribution to a nuclear or mitochondrial origin. We therefore aimed to establish a protocol for the concomitant assessment of oxidized mitochondrial and nuclear DNA from human plasma samples. We applied immunoprecipitation (IP) for 8-oxodGuo to separate oxidized from non-oxidized DNA species and subsequent quantitative polymerase chain reaction (qPCR) to assign them to their subcellular source. The IP procedure failed when applied directly to plasma samples, i.e. isotype control precipitated similar amounts of DNA as the specific 8-oxodGuo antibody. In contrast, DNA isolation from plasma prior to the IP process provided assay specificity with little impact on DNA oxidation status. We further optimized sensitivity and efficiency of qPCR analysis by reducing amplicon length and targeting repetitive nuclear DNA elements. When the established protocol was applied to plasma samples of abdominal aortic aneurysm (AAA) patients and control subjects, the AAA cohort displayed significantly elevated circulating non-oxidized and total nuclear DNA and a trend for increased levels of oxidized mitochondrial DNA. An enrichment of mitochondrial versus nuclear DNA within the oxidized DNA fraction was seen for AAA patients. Regarding the potential source of circulating DNA, we observed a significant correlation of markers of neutrophil activation and NET formation with nuclear DNA, independent of oxidation status. Thus, the established method provides a tool to detect and distinguish the release of oxidized nuclear and mitochondrial DNA in human plasma and offers a refined biomarker to monitor disease conditions of pro-inflammatory cell and tissue destruction.


Assuntos
Aneurisma da Aorta Abdominal , Desoxiguanosina , Humanos , 8-Hidroxi-2'-Desoxiguanosina , DNA Mitocondrial/genética , Oxirredução , Aneurisma da Aorta Abdominal/genética
5.
Int J Surg ; 109(8): 2249-2257, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37402309

RESUMO

BACKGROUND: Monitoring of abdominal aortic aneurysms (AAAs) is currently based on serial measurements of maximum aortic diameter. Additional assessment of aneurysm volume has previously been proposed to possibly improve growth prediction and treatment decisions. To evaluate the use of supplementing volume measurements, the authors aimed to characterise the growth distribution of AAA volume and to compare the growth rates of the maximum diameter and volume at the patient level. METHODS: Maximum diameter and volume were monitored every 6 months in 84 patients with small AAAs, with a total of 331 computed tomographic angiographies (with initial maximum diameters of 30-68 mm). A previously developed statistical growth model for AAAs was applied to assess the growth distribution of volume and to compare individual growth rates for volume and for maximum diameter. RESULTS: The median (25-75% quantile) expansion in volume was 13.4 (6.5-24.7) % per year. Cube root transformed volume and maximum diameter showed a closely linear association with a within-subject correlation of 0.77. At the surgery threshold maximum diameter of 55 mm, the median (25-75% quantile) volume was 132 (103-167) ml. In 39% of subjects, growth rates for volume and maximum diameter were equivalent, in 33% growth was faster in volume and in 27% growth was faster in maximum diameter. CONCLUSION: At the population level, volume and maximum diameter show a substantial association such that the average volume is approximately proportional to the average maximum diameter raised to a power of three. At the individual level, however, in the majority of patient's AAAs grow at different pace in different dimensions. Hence, closer monitoring of aneurysms with sub-critical diameter but suspicious morphology may benefit from complementing maximum diameter by volume or related measurements.


Assuntos
Aneurisma da Aorta Abdominal , Humanos , Estudos de Coortes , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Fatores de Risco
6.
Int J Surg ; 109(4): 861-869, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36999821

RESUMO

BACKGROUND: Abdominal aortic aneurysm (AAA) is a multifactorial vascular disease associated with high morbidity and mortality. Currently, surgical intervention is the only treatment option, and there is no drug therapy available for AAA. Hence, surveillance of AAA until indication for surgery may impact patient quality of life (QoL). There is a paucity of high-quality observational data on health status and QoL, particularly among AAA patients participating in randomized controlled trials. The objective of this study was to compare the QoL scores of AAA patients on surveillance to those of AAA patients enrolled in the MetAAA trial. MATERIAL AND METHODS: Overall, 54 MetAAA trial patients and 23 AAA patients under regular surveillance for small AAA (part of a longitudinal monitoring study) were asked to complete three established and validated (in total 561 longitudinally collected) QoL questionnaires: the 36-Item Short Form Health Survey (SF-36), the Aneurysm Symptom Rating Questionnaire (ASRQ), and the Aneurysm-Dependent Quality of Life questionnaire (ADQoL). RESULTS: A superior health status and QoL was found in AAA patients participating in the MetAAA trial compared to AAA patients under regular surveillance. In detail, MetAAA trial patients showed superior general health perception ( P =0.012), higher energy level ( P =0.036) as well as enhanced emotional well-being ( P =0.044) and fewer limitations due to general malaise ( P =0.021), which was subsequently reflected in an overall superior current QoL score ( P =0.039) compared to AAA patients under regular surveillance. CONCLUSION: AAA patients enrolled in the MetAAA trial showed superior health status and QoL compared to AAA patients under regular surveillance.


Assuntos
Aneurisma da Aorta Abdominal , Qualidade de Vida , Humanos , Estudos Retrospectivos , Aneurisma da Aorta Abdominal/cirurgia , Inquéritos e Questionários
7.
Front Cardiovasc Med ; 10: 1219744, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37576114

RESUMO

Objective: This retrospective study evaluates the performance of UK National Institute for Health and Care Excellence (NICE) Guidelines on management of ruptured abdominal aortic aneurysms in a "real world setting" by emulating a hypothetical target trial with data from two European Aortic Centers. Methods: Clinical data was retrospectively collected for all patients who had undergone ruptured endovascular aneurysm repair (rEVAR) and ruptured open surgical repair (rOSR). Survival analysis was performed comparing NICE compliance to usual care strategy. NICE compliers were defined as: female patients undergoing rEVAR; male patients >70 years old undergoing rEVAR; and male patients ≤70 years old undergoing rOSR. Hemodynamic instability was considered additionally. Results: This multicenter study included 298 patients treated for rAAA. The majority of patients were treated with rOSR (186 rOSR vs. 112 rEVAR). Overall, 184 deaths (68 [37%] with rEVAR and 116 [63%] with rOSR) were observed during the study period. Overall survival under usual care was 69.2% at 30 days, 56.5% at one year, and 42.4% at 5 years. NICE compliance gave survival outcomes of 73.1% at 30 days, 60.2% at 1 year and 42.9% at 5 years. The risk ratios at these time points, comparing NICE-compliance to usual care, were 0.88, 0.92 and 0.99, respectively. Conclusions: We support NICE recommendations to manage men below the age of 71 years and hemodynamic stability with rOSR. There was a slight survival advantage for NICE compliers overall, in men >70 years and women of all ages.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA