Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
J Anesth ; 28(4): 628-30, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24347033

RESUMO

One of the controversial management options for accidental dural puncture in pregnant patients is the conversion of labor epidural analgesia to continuous spinal analgesia by threading the epidural catheter intrathecally. No clear consensus exists on how to best prevent severe headache from occurring after accidental dural puncture. To investigate whether the intrathecal placement of an epidural catheter following accidental dural puncture impacts the incidence of postdural puncture headache (PDPH) and the subsequent need for an epidural blood patch in parturients. A retrospective chart review of accidental dural puncture was performed at Hutzel Women's Hospital in Detroit, MI, USA for the years 2002-2010. Documented cases of accidental dural punctures (N = 238) were distributed into two groups based on their management: an intrathecal catheter (ITC) group in which the epidural catheter was inserted intrathecally and a non-intrathecal catheter (non-ITC) group that received the epidural catheter inserted at different levels of lumbar interspaces. The incidence of PDPH as well as the necessity for epidural blood patch was analyzed using two-tailed Fisher's exact test. In the non-ITC group, 99 (54 %) parturients developed PDPH in comparison to 20 (37 %) in the ITC [odds ratio (OR), 1.98; 95 % confidence interval (CI), 1.06-3.69; P = 0.03]. Fifty-seven (31 %) of 182 patients in the non-ITC group required an epidural blood patch (EBP) (data for 2 patients of 184 were missing). In contrast, 7 (13 %) of parturients in the ITC group required an EBP. The incidence of EBP was calculated in parturients who actually developed headache to be 57 of 99 (57 %) in the non-ITC group versus 7 of 20 (35 %) in the ITC group (OR, 2.52; 95 % CI, 0.92-6.68; P = 0.07). The insertion of an intrathecal catheter following accidental dural puncture decreases the incidence of PDPH but not the need for epidural blood patch in parturients.


Assuntos
Placa de Sangue Epidural/métodos , Dura-Máter/lesões , Injeções Espinhais/efeitos adversos , Cefaleia Pós-Punção Dural/terapia , Adulto , Anestesia Obstétrica , Catéteres/efeitos adversos , Feminino , Humanos , Erros Médicos , Gravidez , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA