Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Chromatogr A ; 1044(1-2): 97-111, 2004 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-15354431

RESUMO

Electrochromatography (EC) in microfluidic chips is emerging as an attractive alternative to capillary electrophoresis (CE) for on-chip separations. This review summarizes recent developments in the rapidly growing area of chip electrochromatography with a focus on "column" technologies. Relevant achievements are summarized according to the types of stationary phase used for the separations including open channels, microfabricated structures, and channels packed with beads or containing a porous monolith. The advantages and disadvantages of each, as well as practical aspects of their application, are discussed. The analytical performance of these devices is demonstrated with separations involving various families of compounds mostly in the reversed-phase chromatographic mode.


Assuntos
Cromatografia Capilar Eletrocinética Micelar/instrumentação , Animais , Bovinos , Espectrometria de Massas , Microscopia Eletrônica de Varredura , Polímeros/química
2.
Electrophoresis ; 29(18): 3875-86, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18850656

RESUMO

A polyacrylate-based monolithic column bearing cationic functionalities and designed for capillary electrochromatography (CEC) has been prepared via photopolymerization of a mixture of hexyl acrylate, butanediol diacrylate, 2-(acryloyloxy) ethyltrimethyl ammonium chloride (monomers), azobisisobutyronitrile (photoinitiator), acetonitrile, phosphate buffer, and ethanol (porogens). The polymerization process was initiated with UV light at 360 nm. The column performance was evaluated via the separations of alkylbenzenes, substituted anilines, basic drugs, peptides, and a protein digest. The separation of complex peptide mixtures was then studied since such separations constitute a promising application of capillary electrochromatography. In particular, the effects of mobile phase composition, including ionic strength of the buffer solution and the percentage of acetonitrile on the retention factor, the column efficiency, and the resolution were determined. The separations were affected by both interaction of the peptides with the stationary phase and their own electrophoretic mobility. Excellent separations with column efficiencies of up to 160 000 plates/m were achieved for both a mixture of ten well-defined peptides and a tryptic digest of cytochrome c. The fractions of eluent containing peptides of the digest separated in the monolithic column were collected and characterized using matrix-assisted laser desorption ionization mass spectrometry.


Assuntos
Resinas Acrílicas/química , Eletrocromatografia Capilar/instrumentação , Peptídeos/isolamento & purificação , Butileno Glicóis/química , Eletrocromatografia Capilar/métodos , Eletro-Osmose , Concentração de Íons de Hidrogênio , Peptídeos/análise , Compostos de Amônio Quaternário/química , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Raios Ultravioleta
3.
Anal Chem ; 79(17): 6592-8, 2007 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-17658765

RESUMO

A method for photopatterning multiple enzymes on porous polymer monoliths within microfluidic devices has been developed and used to perform spatially separated multienzymatic reactions. To reduce nonspecific adsorption of enzymes on the monolith, its pore surface was modified by grafting poly(ethylene glycol), followed by surface photoactivation and enzyme immobilization in the presence of a nonionic surfactant. Characterization of bound horseradish peroxidase (HRP) was carried out using a reaction in which the steady-state profiles of the fluorescent reaction product could be measured in situ and then analyzed using a plug-flow bioreactor model to determine the observed maximum reaction rate and Michaelis constant. The Michaelis constant of 1.9 micro mol/L agrees with previously published values. Mass-transfer limitations were evident at relatively low flow rates but were absent at higher flow rates. Sequential multienzymatic reactions were demonstrated using the patternwise assembly of two- and three-enzyme systems. Glucose oxidase (GOX) and HRP were patterned in separate regions of a single channel, and product formation was analyzed as a function of flow direction. Significant product formation occurred only in the GOX to HRP direction. A three-enzyme sequential reaction was performed using invertase, GOX, and HRP. All possible arrangements of the three enzymes were tested, but significant product formation was only observed when the enzymes were in the correct sequential order. Photopatterning enzymes on polymer monoliths provides a simple technique for preparing spatially localized multiple-enzyme microreactors capable of directional synthesis.


Assuntos
Peroxidase do Rábano Silvestre/metabolismo , Técnicas Analíticas Microfluídicas/métodos , Complexos Multienzimáticos/metabolismo , Polímeros/química , Adsorção , Enzimas Imobilizadas/metabolismo , Cinética , Fotoquímica , Tensoativos/química , Fatores de Tempo
4.
J Sep Sci ; 30(7): 1088-93, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17566345

RESUMO

The plastic material known as cyclic olefin copolymer (COC) is a useful substrate material for fabricating microfluidic devices due to its low cost, ease of fabrication, excellent optical properties, and resistance to many solvents. However, the hydrophobicity of native COC limits its use in bioanalytical applications. To increase surface hydrophilicity and reduce protein adsorption, COC surfaces were photografted with poly(ethylene glycol) methacrylate (PEGMA) using a two-step sequential approach: covalently-bound surface initiators were formed in the first step and graft polymerization of PEGMA was then carried out from these sites in the second step. Contact angle measurements were used to monitor and quantify the changes in surface hydrophilicity as a function of grafting conditions. As water droplet contact angles decreased from 88 degrees for native COC to 45 degrees for PEGMA-grafted surfaces, protein adsorption was also reduced by 78% for the PEGMA-modified COC microchannels as determined by a fluorescence assay. This photografting technique should enable the use of COC microdevices in a variety of bioanalytical applications that require minimal nonspecific adsorption of biomolecules.


Assuntos
Cicloparafinas/química , Técnicas Analíticas Microfluídicas/instrumentação , Polietilenoglicóis/química , Polímeros/química , Cicloparafinas/efeitos da radiação , Desenho de Equipamento , Técnicas Analíticas Microfluídicas/métodos , Fotoquímica , Polímeros/síntese química , Polímeros/efeitos da radiação , Ácidos Polimetacrílicos/química , Sensibilidade e Especificidade , Propriedades de Superfície , Fatores de Tempo , Raios Ultravioleta , Água/química , Molhabilidade
5.
Electrophoresis ; 24(21): 3689-93, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14613194

RESUMO

UV-initiated grafting of plastic tubes and microfluidic chips with ethylene diacrylate followed by the preparation of porous polymer monoliths has been studied. The first step affords a thin grafted layer of polymer with a multiplicity of pendent double bonds that are then used in the second step for covalent attachment of the monolith to the wall. As clearly seen on scanning electron micrographs, this procedure prevents the formation of voids at the monolith-channel interface a problem that has always plagued approaches involving bulk polymerization in nontreated channels due to the shrinkage of the monolith during the polymerization process and its lack of compatibility with the material of the device. Irradiation with UV light through a photomask allows precise patterning specifying both the area subjected to surface modification and the location of the monolith within specific areas of the device.


Assuntos
Miniaturização/métodos , Plásticos , Microfluídica/métodos , Microscopia Eletrônica de Varredura , Técnicas de Sonda Molecular , Polímeros
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA