Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Arthroplasty ; 39(1): 242-249.e2, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37380142

RESUMO

BACKGROUND: The aim of the present study was to compare causative bacteria and their antibiotic resistance profiles in patients developing a periprosthetic joint infection (PJI) based on preoperative prophylactic antibiotic regimens in primary total hip (THA) and primary total and unicompartmental knee arthroplasty (TKA/UKA). METHODS: We reviewed all cases of PJI occurring after primary THA and primary TKA/UKA, between 2011 and 2020 in a tertiary referral hospital. The standard preoperative prophylactic antibiotic for primary joint arthroplasty was cefuroxime and recommended second-line agent was clindamycin. Patients were divided by the replaced joint and analyzed independently. RESULTS: In the THA group, culture-positive PJI was detected in 61 of 3,123 (2.0%) cefuroxime-administered cases and 6 of 206 (2.9%) noncefuroxime-administered cases. In the TKA/UKA group, culture positive PJI was identified in 21 of 2,455 (0.9%) cefuroxime-administered cases and in 3 of 211 (1.4%) noncefuroxime administered cases. The most commonly isolated bacteria in both groups were coagulase negative staphylococci (CNS). There were no statistically significant differences of pathogen spectrum depending on the preoperative antibiotic regimen detected. Antibiotic resistance of isolated bacteria was significantly different in 4 of 27 (14.8%) analyzed antibiotics in THA and in 3 of 22 (13.6%) analyzed antibiotics in TKA/UKA. In all cohorts, a high occurrence of oxacillin-resistant CNS (50.0 to 100.0%) and clindamycin-resistant CNS (56.3 to 100.0%) has been observed. CONCLUSION: The use of the second-line antibiotic did not influence the pathogen spectrum or antibiotic resistance. However, an alarmingly high proportion of CNS strains was resistant to clindamycin.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Hipersensibilidade a Drogas , Hipersensibilidade , Infecções Relacionadas à Prótese , Humanos , Antibacterianos/uso terapêutico , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Cefuroxima , Clindamicina , Resistência Microbiana a Medicamentos , Hipersensibilidade/complicações , Hipersensibilidade/tratamento farmacológico , Medidas de Resultados Relatados pelo Paciente , Penicilinas , Infecções Relacionadas à Prótese/etiologia , Estudos Retrospectivos , Staphylococcus
2.
Sensors (Basel) ; 24(16)2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39204964

RESUMO

Total knee arthroplasty (TKA) is a well-established and successful treatment option for patients with end-stage osteoarthritis of the knee, providing high patient satisfaction. Robotic systems have been widely adopted to perform TKA in orthopaedic centres. The exact spatial positions of the femur and tibia are usually determined through pinned trackers, providing the surgeon with an exact illustration of the axis of the lower limb. The drilling of holes required for mounting the trackers creates weak spots, causing adverse events such as bone fracture. In the presented computational feasibility study, time differential electrical impedance tomography is used to locate the femur positions, thereby the difference in conductivity distribution between two distinct states s0 and s1 of the measured object is reconstructed. The overall approach was tested by simulating five different configurations of thigh shape and considered tissue conductivity distributions. For the cylinder models used for verification and reference, the reconstructed position deviated by about ≈1 mm from the actual bone centre. In case of models mimicking a realistic cross section of the femur position deviated between 7.9 mm 24.8 mm. For all models, the bone axis was off by about φ=1.50° from its actual position.


Assuntos
Artroplastia do Joelho , Estudos de Viabilidade , Fêmur , Procedimentos Cirúrgicos Robóticos , Tíbia , Humanos , Artroplastia do Joelho/métodos , Fêmur/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Tíbia/cirurgia , Impedância Elétrica
3.
Artigo em Inglês | MEDLINE | ID: mdl-39249133

RESUMO

INTRODUCTION: Implementing new approaches or new implants is always related with a certain learning curve in total hip arthroplasty (THA). Currently, many surgeons are switching to minimally invasive approaches combined with short stems for performing THA. Therefore, we aimed to asses and compare the learning curve of switching from an anterolateral Watson Jones approach (ALA) to a direct anterior approach (DAA) with the learning curve of switching from a neck-resecting to a partially neck-sparing short stem in cementless THA. MATERIALS AND METHODS: The first 150 consecutive THA performed through a DAA (Group A) and the first 150 consecutive THA using a partially neck-sparing short stem (Group B) performed by a single surgeon were evaluated within this retrospective cohort study. All cases were screened for surgery related adverse events (AE). Furthermore, the operative time of each surgery was evaluated and the learning curve assessed performing a cumulative sum (CUSUM) analysis. RESULTS: Overall, significantly more AE occurred in Group A compared to Group B (18.0% vs. 10.0%; p = 0.046). The sub-analysis of the AE revealed higher rates of periprosthetic joint infections (2.7% vs. 0.7%; p = 0.176), periprosthetic fractures (4.0% vs. 2.0%; p = 0.310) and overall revisions (4.7% vs. 1.3% p = 0.091) within Group A without statistical significance. The CUSUM analysis revealed a consistent reduction of operative time after 97 cases in Group A and 79 cases in Group B. CONCLUSION: A significantly higher overall rate of AE was detected while switching approach compared to switching implant for performing THA. However, according to the results of this study, surgeons should be aware of the learning curve of the adoption to a new implant with different fixation philosophy as well.

4.
Knee Surg Sports Traumatol Arthrosc ; 31(3): 969-978, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35969255

RESUMO

PURPOSE: Cemented fixation remains the gold standard in total knee arthroplasty. With an increasing number of younger patients undergoing total knee arthroplasty and a growing patient population demanding higher physical activity, a rising interest in discussion of cementless fixation is notable. The current scientific literature does not give a clear recommendation for or against uncemented total knee arthroplasty. The purpose of this study was the investigation of the 5-year clinical and radiographic outcomes of a cementless deep-dish rotating platform implant. METHODS: A total of 91 primary cementless total knee arthroplasties were included in this single-centre prospective observational study. The primary outcome was revision rate due to aseptic component loosening. Further outcome measures were assessment of the of the radiographic outcome as well as the clinical outcome based on Range of Motion and scores such as American Knee Society Score, Oxford Knee Score, Knee Injury and Osteoarthritis Outcome Score and European Quality of Life 5 Dimension 3 Level at a follow-up of 5 years. RESULTS: Mean age of the study population was 67.3 ± 6.6 years with 49.5% of the participants being female. Aseptic component loosening occurred in none of the patients. Implant survival with revision for any reason as endpoint was 97.8% (95% CI 100-96%) and 95.6% (95% CI 100-94%) with reoperation of any cause as endpoint. Radiolucent lines were detected in a total of eight cases (8.8%) and disappeared within the first year after surgery in five cases. Total Range of Motion improved significantly from 106° ± 15° preoperatively to 118° ± 10° at final FU (p < 0.001). All investigated scores improved significantly after total knee arthroplasty. CONCLUSION: The results of this study reveal excellent mid-term performance of a cementless deep dish rotating platform total knee implant, with no component loosening, very low overall revision rate, only temporarily present radiolucent lines in a minority of patients and excellent clinical results. Therefore, cementless total knee arthroplasty is an appropriate treatment option for patients with severe osteoarthritis of the knee. LEVEL OF EVIDENCE: Level II (prospective cohort study).


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Seguimentos , Estudos Prospectivos , Qualidade de Vida , Artroplastia do Joelho/métodos , Prótese do Joelho/efeitos adversos , Reoperação/efeitos adversos , Osteoartrite/etiologia , Resultado do Tratamento , Falha de Prótese
5.
Arch Orthop Trauma Surg ; 143(1): 519-527, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34997306

RESUMO

PURPOSE: Short stems are increasingly used in total hip arthroplasty (THA) because of advantages in bone and soft tissue preservation and reconstruction of hip geometry. Digital templating is essential in determining the correct offset option and stem size in THA. However, the preoperative template sizes might be intraoperatively overruled. PATIENTS AND METHODS: We evaluated the effect of intraoperative overruling of the preoperatively templated offset option of a short curved stem on hip offset, leg length, implant positioning, and femoral canal fill index. The overruling was performed in case of intraoperative instability, telescoping, or both. A series of 1052 consecutive THAs with a cementless short curved stem and press-fit cup was retrospectively screened. One hundred patients with unilateral THA and a contralateral native and morphologically healthy hip as a reference met the inclusion criteria. Measurements were carried out on preoperative and 3 months anterior-posterior postoperative radiographs. Patients were divided according to the overruling by offset option or stem size. RESULTS: Hip offset was increased in all groups, but only with significant increase if an offset option + 1 was used intraoperatively (p = 0.025). LLD was restored without significance in all groups (p = 0.323; p = 0.157). CONCLUSION: Intraoperative overruling of the preoperative digital template in cementless short stem total hip arthroplasty results in an increase of hip offset compared to a contralateral healthy hip. However, the increase is marginal and clearly under 5 mm compared to the contralateral healthy hip.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Radiografia , Osso e Ossos/cirurgia , Articulação do Quadril/cirurgia
6.
Arch Orthop Trauma Surg ; 143(2): 773-784, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34524486

RESUMO

INTRODUCTION: Foot drop is a disorder that impairs walking and leads to tripping and falling. Tendon transfer (e.g., tibialis posterior tendon) is a typical secondary procedure in foot drop treatment. The purpose of this systematic review was to identify the most common tendon transfer techniques for treating foot drop and to analyze the reported functional outcomes. Furthermore, it was of interest if the type of surgical technique affects the functional outcome. METHODS: A PubMed and MEDLINE literature search was performed according to PRISMA guidelines. The search terms used were ("tendon transfer" OR "tendon transposition") AND ("foot drop" OR "peroneal neuropathies"). Any study published before January 2020 was considered for inclusion. No case reports or reviews were included. Common outcome measures (Stanmore score, AOFAS, FAAM, AFO use, patient satisfaction and active ankle dorsiflexion) were evaluated. The quality of the included studies was assessed using the Coleman Methodology Score. RESULTS: Of the 125 reviewed publications, 37 met the inclusion criteria. 42 cohorts were analyzed. The frequently reported tendon transfer technique was the tibialis posterior tendon transfer through the interosseus membrane. The most used fixation technique was tendon on tendon fixation; however in recent years, a tendon to bone fixation has gained popularity. There was an increase in Stanmore scores and AOFAS postoperatively and a decrease of AFO use postoperatively observed. CONCLUSIONS: Due to various outcome measures and lack of preoperative assessment in the included studies, a meta-analysis of the pooled results was not possible. Nevertheless, the findings of this study show that tendon transfer increases mobility and self-independency leading to patient satisfaction. The choice of the surgical technique does not affect the outcome. A prospective collection of patient data and standardized outcome measures will be important to further analyze the efficacy of tendon transfer techniques.


Assuntos
Neuropatias Fibulares , Transferência Tendinosa , Humanos , Satisfação do Paciente , Neuropatias Fibulares/cirurgia , Estudos Prospectivos , Transferência Tendinosa/métodos , Tendões , Resultado do Tratamento
7.
Arch Orthop Trauma Surg ; 143(3): 1193-1202, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34687350

RESUMO

BACKGROUND: Pelvic and femoral osteotomies have been effective methods to treat developmental dysplasia of the hip (DDH), neurogenic dislocation of the hip (NDH), and Legg-Calvé-Perthes disease (LCPD). The aim of this study was to evaluate the mid-term results after hip reconstruction in children with DDH, NDH, and LCPD. METHODS: In a retrospective study, X-rays of 73 children (2-19 years) with DDH, NDH, and LCPD were measured before, 3 months, and at final follow-up (FU) after hip reconstructive surgery (open reduction, and femoral and/or pelvic osteotomy ± soft-tissue procedures between 2008 and 2018). Measurement of hip geometry included acetabular index (AI), center-edge angle (CE), and Reimers migration index (RMI). Mean follow-up time at final FU was 4.9 years. P value was set P < 0.05. RESULTS: After surgery (femoral osteotomy: 84 hips, Salter innominate osteotomy: 21 hips, Pemberton osteotomy: 30 hips, open reduction: 28 hips, Chiari osteotomy: 4 hips, and soft-tissue release: 24 hips), hip geometry parameters improved significantly. Nevertheless, at final FU, there was deterioration in hip geometry with femoral head lateralization (RMI) compared to the data at 3 months after surgery (RMI: preop/3 months/final FU: 40.6 ± 16.1%/6.1 ± 9.0/15.4 ± 16.0%; CE: 11.3° ± 20.0°/30.2° ± 9.5°/27.9 ± 15.4°; AI: 28.8° ± 9.6°/19.1° ± 7.6°/18.3 ± 7.6°). Sub-group analysis did not show differences concerning the progression of RMI in DDH, NDH, and LCPD at final FU. Regardless of basic disease, the lateralization was observed in all three groups (DDH, NDH, and LCPD) and statistically significant comparing X-rays 3 months postoperatively to maximum follow-up (DDH; NDH; LCPD: 2.7 ± 6.8%/7.6 ± 10.1%; 13.7 ± 15.3%/22.8 ± 19.8%; 1.7 ± 4.1%/14.9 ± 11.3%). Additional soft-tissue release techniques in patients with DDH or NDH did not show postoperative differences with statistical significance. Concerning surgical techniques, a connection between the lower RMI and the procedure of osteotomy of the ilium was found. In 25 patients, (34%) complications were observed: superficial skin lesions in 8, deep skin lesions in 3, contraction of adductors in 3, subluxation in 2, dislocations of the cast in 2, osteonecrosis of the femoral head in 2 cases, reluxation in 1, infection of the implanted plate in 1, compliance problem in 1, delayed bone healing in 1, and contraction of knee flexors in 1 case. DISCUSSION: The basic results of this study show a significant improvement of hip geometry at a follow-up of 4.9 years and prove findings of previously published literature. Moreover, the study was able to show a progression of RMI in all patient groups, which have undergone reconstructive surgery, despite basic hip geometry data (AI, CE angle) did not change. Those findings were independent from underlying pathology. Complications were counted in 34% of the patients and involved all known adverse events after hip reconstructive surgery. This makes clear why annual follow-up checks are needed not to miss the right indication for revision surgery. CLINICAL RELEVANCE: Evidence level: Level IV, case series. TRIAL REGISTRATION: This manuscript is part of a prospective randomized clinical trial, registered in the German Clinical Trials Register DRKS-ID: DRKS00016861.


Assuntos
Luxação Congênita de Quadril , Luxação do Quadril , Doença de Legg-Calve-Perthes , Cirurgia Plástica , Humanos , Criança , Doença de Legg-Calve-Perthes/cirurgia , Estudos de Coortes , Seguimentos , Estudos Retrospectivos , Estudos Prospectivos , Resultado do Tratamento , Luxação do Quadril/cirurgia , Acetábulo/cirurgia , Articulação do Quadril/cirurgia , Luxação Congênita de Quadril/cirurgia
8.
Medicina (Kaunas) ; 59(2)2023 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-36837521

RESUMO

Background and Objectives: Noise exposure during total knee arthroplasty (TKA) has been demonstrated to exceed thresholds that are deemed as over-exposure by industry noise level standards. With orthopedic surgeons being at risk of suffering from Noise Induced Hearing Loss, the purpose of this pilot study was to evaluate the viability of the use of industry grade active noise cancelling headphones (ANCH) during TKA. Material and Methods: In this prospective pilot study, 10 TKA were performed. In five of these cases, surgeon, assistant, scrub nurse and anesthetist wore ANCH with automatic noise level dependent noise attenuation above 82 dB. A validated 14-item questionnaire was used after each case to evaluate the quality of communication, performance, teamwork and mental load. In seven cases a calibrated sound level meter was used to measure the operating theatre noise. Peak sound level (LApeak), A-weighted continuous sound level (LAeq) and A-weighted noise exposure averaged for an 8-h time-period (LEPd) were calculated. Results: There was no perceived benefit of ANCH for the surgeons (p = 0.648), assistants (p = 0.908) and scrub nurses (p = 0.251). There was an overall improvement observed by anesthetists (p = 0.001). A worse communication while wearing ANCH was reported by surgeons but not by the rest of the team. Average LApeak was 90.6 ± 3.2 dB(C), LAeq was 61.9 ± 1.0 dB(A) and LEPd was 53.2 ± 1.2 dB(A). Conclusions: Industry grade ANCH seem to provide no benefit for surgeons, assistants and scrub nurses during TKA, while anesthesiologists seem to benefit from the use of ANCH during TKA. Due to the limitations of this pilot study, further studies with larger study populations are necessary to adequately investigate the use of ANCH during TKA.


Assuntos
Artroplastia do Joelho , Cirurgiões , Humanos , Projetos Piloto , Estudos Prospectivos , Ruído
9.
J Arthroplasty ; 37(6S): S306-S312, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35210149

RESUMO

BACKGROUND: Antimicrobial resistance is recognized as a major public health threat. It occurs naturally; however, an excessive antibiotic use and misuse of antibiotics accelerate the process. Periprosthetic joint infections (PJI) are becoming harder to treat as the efficacy of antibiotics is becoming lower. The aim of this study was to compare the resistance of coagulase-negative staphylococci (CNS) to antibiotics identified after revision TKAs for PJI between two major orthopedic centers. METHODS: A review of all revision TKAs, undertaken between 2006 and 2018 in two orthopedic centers, was performed, including all those meeting the consensus criteria for PJI, in which CNS were identified. There were no major differences in surgical approach and tissue sampling between both centers. Thirteen commonly used antibiotics were tested at both centers. RESULTS: The 132 strains were analyzed for their resistance to 13 different antibiotics. Staphylococcus epidermidis was identified in 70.5% cultures, followed by Staphylococcus capitis in 8.3% cultures. The comparison of antibiotic resistance between two centers was statistically significant to penicillin (P = .001), oxacillin (P = .011), cefuroxime (P = .044), levofloxacin (P = .006), moxifloxacin (P = .008), tetracycline (P < .001), rifampicin (P < .001) and vancomycin (P < .001). The difference of resistance of CNS was not statistically significant to fosfomycin, clindamycin, teicoplanin, erythromycin and ampicillin. CONCLUSIONS: The resistance of CNS to antibiotics differs significantly between two major orthopedic centers that are geographically fairly close. Monitoring of bacteriological analyses in each referral center should be continuously performed. Close monitoring is needed for more efficient antibiotic treatment of and prophylaxis against PJI.


Assuntos
Artrite Infecciosa , Artroplastia do Joelho , Infecções Relacionadas à Prótese , Antibacterianos/uso terapêutico , Artrite Infecciosa/cirurgia , Artroplastia do Joelho/efeitos adversos , Coagulase/uso terapêutico , Farmacorresistência Bacteriana , Humanos , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/prevenção & controle , Infecções Relacionadas à Prótese/cirurgia , Estudos Retrospectivos , Staphylococcus
10.
Medicina (Kaunas) ; 58(2)2022 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-35208611

RESUMO

Background and Objectives: Due to inferior survival rates compared to hip and knee arthroplasty, total ankle arthroplasty (TAA) was previously mainly recommended for older and less active patients. However, given the encouraging survival rates and clinical outcomes of modern generations of TAA, some authors have also advocated TAA in young patients. Thus, the aim of this study was to evaluate age related reoperation, revision and survival rates of third-generation mobile-bearing TAAs. Materials andMethods: In this retrospective study, 224 consecutive TAA patients with a minimum follow up (FU) of 2 years were analyzed. Patients were retrospectively assigned to two study groups (Group A: age < 50 years; Group B: age ≥ 50 years). Revision was defined as secondary surgery with prothesis component removal, while reoperation was defined as a non-revisional secondary surgery involving the ankle. Results: After a mean FU of 7.1 ± 3.2 years, the reoperation rate (Group A: 22.2%; Group B: 5.3%; p = 0.003) and revision rate (Group A: 36.1%; Group B: 13.8%; p = 0.003) were higher within Group A. An age of under 50 years at time of surgery was associated with higher reoperation (odds ratio (OR): 6.54 (95% CI: 1.96-21.8); p = 0.002) and revision rates (OR: 3.13 (95% CI: 1.22-8.04); p = 0.018). Overall, lower patient age was associated with higher reoperation (p = 0.009) and revision rates (p = 0.001). Conclusions: The ideal indication for TAA remains controversial, especially regarding patient age. The findings of this study show high reoperation and revision rates in patients aged under 50 years at time of surgery. Therefore, the outcomes of this study suggest that the indication for TAA in young patients should be considered very carefully and that the association between low patient age and high reoperation rate should be disclosed to all eligible patients.


Assuntos
Tornozelo , Artroplastia de Substituição do Tornozelo , Idoso , Articulação do Tornozelo , Artroplastia de Substituição do Tornozelo/efeitos adversos , Humanos , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA