Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Plants (Basel) ; 12(6)2023 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-36987054

RESUMO

For the first time, a macrophyte-based assessment of ecological status was related to the accumulated heavy metals and trace elements (Al, As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Zn) in aquatic plants. Three moss and two vascular plant species were applied as biomonitors: Fontinalis antipyretica Hedw., Leptodictyum riparium (Hedw.) Warnst., Platyhypnidium riparioides (Hedw.) Dixon, invasive Elodea canadensis Michx., and Myriophyllum spicatum L. Three streams were assessed as good at a high ecological status which correlated with low contamination based on calculated contamination factors (CFs) and metal pollution index (MPI). Two sites evaluated in moderate ecological status were revealed to be in heavy trace element contamination. The most significant was the accumulation of moss samples from the Chepelarska River under mining impact. Mercury exceeded the environmental quality standard (EQS) for biota in three of the studied upland river sites.

2.
Talanta ; 160: 389-399, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27591629

RESUMO

In the present work the potential of a new ligand 3-Ethylamino-but-2-enoic acid phenylamide (representing the class of enaminones) for selective preconcentration of lanthanides (La, Ce, Eu, Gd and Er) from aqueous medium is examined. Liquid-liquid extraction parameters, such as pH of the water phase, type and volume of organic solvent, quantity of ligand and reaction time are optimized on model solutions. Recovery of lanthanides by re-extraction with nitric acid makes the LLE procedure compatible with Inductively Coupled Plasma Mass Spectrometry. Spectral and non-spectral interferences are studied. Two isotopes per element are measured (with exception of La) for dynamic evaluation of the potential risk of spectral interference in variable real samples. The selectivity of complex formation reaction towards concomitant alkali and alkali-earth elements eliminates the interferences from sample matrix. Subjecting the standards to the optimized extraction procedure in combination with Re as internal standard is recommended as calibration strategy. The accuracy of developed method is approved by analysis of CRM Bush branches and leaves (NCS DC 73348) and recovery of spiked water and plant samples. The method's limits of detection for both studied objects are in the ranges from 0.2 ((158)Gd) to 3.7 ((139)La) ngl(-1) and 0.02 ((158)Gd) to 0.37((139)La) ngg(-1) for waters and plants respectively. The studied compound is an effective new ligand for preconcentration/separation of lanthanides from aqueous medium by LLE and subsequent determination by ICP-MS.

3.
Talanta ; 59(1): 123-36, 2003 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-18968892

RESUMO

An automated, fast and reliable procedure has been developed for flame atomic absorption analysis of Ca, Fe and Mn in moss. The method is suitable for routine analysis of a large number of moss samples and allows sequential determination of all three elements in the same solution. In order to inhibit the matrix interference on Ca and to level the diverse analytical behaviour of the moss matrix, approximately 1% La was added to both samples and standard solutions as well. An integrated system of 'sandwich-type' air segmented discrete sample introduction and flame atomic absorption detection (ASDI-FAAS) was successfully applied. It works at 'solvent-air-sample-air-solvent' mode, which tolerates the introduction of high salt content solutions, reduces reagent and sample consumption and allows the application of data treatment models to pseudo-steady state signals for bettering the repeatability. For moss samples containing high Ca and Fe concentrations, equivalent procedure was used by turned on 45 degrees burner head without worsening the analytical characteristics. Concerning these three elements, the method is suggested as a cheaper, easier and more trustworthy alternative with a better precision to the inductively coupled plasma-mass spectrometry (ICP-MS) one. The ASDI-FAAS results were used for selection of appropriate isotopes and correction procedures for ICP-MS determination. Both methods show good agreement of the Ca, Fe and Mn results that correspond to the moss reference materials tested.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA