RESUMO
PURPOSE: To compare the safety and efficacy of histotripsy with cryoablation in a chronic human-scale normal porcine kidney model. MATERIALS AND METHODS: Eighteen female domestic swine were divided evenly into histotripsy and cryoablation treatment arms. A planned 2-3 cm diameter treatment was performed under ultrasound (histotripsy) or ultrasound and computed tomography (CT) guidance (cryoablation). Contrast-enhanced CT and serum blood analysis were performed immediately postprocedure and on day 7, with either immediate killing (n = 3) or continued survival to day 30 (n = 6), at which time contrast-enhanced CT, serum blood analysis, and necropsy were performed. Animal welfare, treatment zone appearance, procedure-related adverse events, and histopathology of the treatment zones and surrounding tissues were assessed. RESULTS: Histotripsy treatment zones (mean ±standard deviation diameters, 2.7 ± 0.12 × 2.4 ± 0.19 × 2.4 ± 0.26 cm; volume, 8.3 ± 1.9 cm3) were larger than cryoablation zones (mean diameters, 2.2 ± 0.19 × 1.9 ± 0.13 × 1.7 ± 0.19 cm; volume, 3.9 ± 0.8 cm3; P < .001). At 30 days, histotripsy and cryoablation treatment zone volumes decreased by 96% and 83% on CT, respectively (P < .001). Perirenal hematomas were present after 8 of 9 (89%) cryoablation (mean volume, 22.2 cm3) and 1 of 9 (11%, P < .001) histotripsy (volume, 0.4 cm3) procedures, with active arterial extravasation in 4 of 9 (44%) cryoablation and no histotripsy animals (P = .206). All 9 histotripsy animals and 5 of 9 (56%) cryoablation animals had collecting system debris (P = .042). Changes in serum creatinine were similar between the groups (P = .321). CONCLUSIONS: Other than a higher rate of bleeding after cryoablation, the safety and early efficacy of histotripsy and cryoablation were comparable for creating treatment zones in a chronic normal porcine kidney model.
Assuntos
Criocirurgia , Neoplasias Renais , Humanos , Suínos , Feminino , Animais , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Rim/patologia , Neoplasias Renais/patologia , Tomografia Computadorizada por Raios X , Hemorragia Gastrointestinal/etiologia , Resultado do TratamentoRESUMO
Spine injections are commonly performed in the treatment of back pain. The purpose of this article is to review the current literature surrounding image guided spine injections focusing on scenarios where fluoroscopic guidance can be advantageous in addition to discussing similarities among the different modalities.
Assuntos
Dor nas Costas , Humanos , Injeções Epidurais/métodos , Dor nas Costas/diagnóstico por imagem , Dor nas Costas/tratamento farmacológico , FluoroscopiaRESUMO
OBJECTIVE: The aim of this study is to investigate the safety and feasibility of ultrasound-guided nerve block prior to biopsy of potentially neurogenic tumors. MATERIALS AND METHODS: A retrospective review of the medical record from June 2017 to June 2022 identified ultrasound-guided biopsies of potentially neurogenic tumors that were performed with a pre-procedural nerve block. Patient demographics, biopsy site, number of passes, needle gauge, use of sedation, pathology results, and procedural complications were recorded and summarized. RESULTS: The structured search found 16 patients that underwent biopsies of 18 potentially neurogenic tumors with the use of a pre-procedural nerve block at a variety of upper and lower extremity locations. Average patient age was 52 (range 18-78) and 9 patients (56%) were female. Of the 16 patients, 10 were performed without intravenous sedation. Three patients were unable to tolerate biopsy until a nerve block was used. All biopsies yielded a diagnostic sample with 13 of the tumors neurogenic in origin. One patient reported mild postprocedural pain which resolved with conservative treatment; no other complications were reported. CONCLUSION: Nerve block prior to ultrasound-guided biopsy of potentially neurogenic tumors is a safe and feasible technique. Further study is needed to determine the extent to which nerve block can decrease intra-procedural pain and reduce or eliminate the need for sedation during biopsy.
Assuntos
Bloqueio Nervoso , Humanos , Feminino , Masculino , Projetos Piloto , Estudos de Viabilidade , Bloqueio Nervoso/métodos , Biópsia Guiada por Imagem/métodos , Ultrassonografia de Intervenção , Estudos RetrospectivosRESUMO
Spinal pain is a common complaint and cause of disability in the United States, affecting most individuals at some point in their lives. The complex anatomy of the spine leads to multiple potential and coexisting etiologies for pain, and the differentiation of these sources can present a diagnostic challenge. Image-guided spinal injections can provide both diagnostic information identifying pain location as well as prolonged therapeutic relief as an alternative to medical management. Anesthetic and corticosteroid medications can be administered within the epidural space through transforaminal or interlaminar approaches, blocking various sensory nerves, or directly within the facet joints. Proceduralists must be aware of associated patient considerations, techniques, and potential complications to perform the procedures safely. We discuss image-guided spinal injection techniques, based on best practices and our experiences.
Assuntos
Manejo da Dor , Coluna Vertebral , Corticosteroides/uso terapêutico , Humanos , Injeções Epidurais , Injeções Espinhais , Dor , Estados UnidosRESUMO
PURPOSE: Multidisciplinary conferences (MDCs) are important for clinical care but are unreimbursed and can be time-consuming for radiologists to prepare for and present. The purpose of this single-center, prospective, survey-based study is to measure the per-conference time and total time radiologists devote to MDCs at a single academic medical center. Secondary objectives are to determine the source of radiologist preparation time, and calculate the per conference and overall radiology departmental costs of MDC participation. METHODS: A prospective survey was performed to capture all radiology preparation and presentation time for MDCs in a 3-month period, which was then annualized. Total cost was calculated on the basis of Association of Administrators in Academic Radiology survey data for nonchair academic radiologist compensation plus a 30% fringe-benefit rate. RESULTS: The survey response rate was 86.9%. A total of 3,358 hours were devoted annually to MDCs, which represents time equivalent to 1.9 full-time equivalents or $1,155,152 in unreimbursed radiology departmental costs. Per-MDC total preparation and presentation time was 2.7 hours, at an annual cost of $46,440 for each weekly MDC. Radiologists used a combination of personal time (49.7%), academic time (42%), and/or clinical time (35.4%) to prepare for MDCs. Radiologists devoted a mean of 47.9 hours (1.2 weeks) of time per annum to MDCs. CONCLUSIONS: Radiologist time devoted to MDCs at the survey institution was substantial, and preparation time was drawn disproportionately from personal and academic time, which may have negative implications for burnout, recruitment and retention, and academic productivity unless it is effectively mitigated.
Assuntos
Serviço Hospitalar de Radiologia , Radiologia , Humanos , Centros Médicos Acadêmicos , Radiologistas , Inquéritos e QuestionáriosRESUMO
Purpose To determine if microwave ablation (MWA) of retroperitoneal tumors can safely provide high rates of local tumor control. Materials and Methods This retrospective study included 19 patients (median age, 65 years [range = 46-78 years]; 13 [68.4%] men and six [31.6%] women) with 29 retroperitoneal tumors treated over 22 MWA procedures. Hydrodissection (0.9% saline with 2% iohexol) was injected in 17 of 22 (77.3%) procedures to protect nontarget anatomy. The primary outcomes evaluated were local tumor progression (LTP) and complication rates. Oncologic outcomes, including overall survival (OS), progression-free survival (PFS), and treatment-free interval (TFI), were examined as secondary outcome measures. Results Median follow-up was 18 months (range = 0.5-113). Hydrodissection was successful in displacing nontarget anatomy in 16 of 17 (94.1%) procedures. The LTP rate was 3.4% (one of 29; 95% CI: 0.1, 17.8) per tumor and 5.3% (one of 19; 95% CI: 0.1, 26.0) per patient. The overall complication rate per patient was 15.8% (three of 19), including two minor complications and one major complication. The OS rate at 1, 2, and 3 years was 81.8%, 81.8%, and 72.7%, respectively, with a median OS estimated at greater than 7 years. There was no evidence of a difference in OS (P = .34) and PFS (P = .56) between patients with renal cell carcinoma (six of 19 [31.6%]) versus other tumors (13 of 19 [68.4%]) and patients treated with no evidence of disease (15 of 22 [68.2%]) versus patients with residual tumors (seven of 22 [31.8%]). Median TFI was 18 months (range = 0.5-108). Conclusion Treatment of retroperitoneal tumors with MWA combined with hydrodissection provided high rates of local control, prolonged systemic therapy-free intervals, and few serious complications. Keywords: Ablation Techniques (ie, Radiofrequency, Thermal, Chemical), Retroperitoneum, Microwave Ablation, Hydrodissection © RSNA, 2024.
Assuntos
Neoplasias Renais , Neoplasias Retroperitoneais , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Neoplasias Retroperitoneais/diagnóstico por imagem , Neoplasias Retroperitoneais/radioterapia , Neoplasias Retroperitoneais/cirurgia , Resultado do Tratamento , Micro-Ondas/uso terapêutico , Estudos Retrospectivos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgiaRESUMO
CT navigation (CTN) has recently been developed to combine many of the advantages of conventional CT and CT-fluoroscopic guidance for needle placement. CTN systems display real-time needle position superimposed on a CT dataset. This is accomplished by placing electromagnetic (EM) or optical transmitters/sensors on the patient and needle, combined with fiducials placed within the scan field to superimpose a known needle location onto a CT dataset. Advantages of CTN include real-time needle tracking using a contemporaneous CT dataset with the patient in the treatment position, reduced radiation to the physician, facilitation of procedures outside the gantry plane, fewer helical scans during needle placement, and needle guidance based on diagnostic-quality CT datasets. Limitations include the display of a virtual (vs actual) needle position, which can be inaccurate if the needle bends, the fiducial moves, or patient movement occurs between scans, and limitations in anatomical regions with a high degree of motion such as the lung bases. This review summarizes recently introduced CTN technologies in comparison to historical methods of CT needle guidance. A "How I do it" section follows, which describes how CT navigation has been integrated into the study center for both routine and challenging procedures, and includes step-by-step explanations, technical tips, and pitfalls.
Assuntos
Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X , Humanos , Fenômenos Eletromagnéticos , Cirurgia Assistida por Computador/métodosRESUMO
As technology continues to improve within the neuroprosthetic landscape, there has been a paradigm shift in the approach to amputation and surgical implementation of haptic neural prosthesis for limb restoration. The Osseointegrated Neural Interface (ONI) is a proposed solution involving the transposition of terminal nerves into the medullary canal of long bones. This design combines concepts of neuroma formation and prevention with osseointegration to provide a stable environment for conduction of neural signals for sophisticated prosthetic control. While this concept has previously been explored in animal models, it has yet to be explored in humans. This anatomic study used three upper limb and three lower limb cadavers to assess the clinical feasibility of creating an ONI in humans. Anatomical measurement of the major peripheral nerves- circumference, length, and depth- were performed as they are critical for electrode design and rerouting of the nerves into the long bones. CT imaging was used for morphologic bone evaluation and virtual implantation of two osseointegrated implants were performed to assess the amount of residual medullary space available for housing the neural interfacing hardware. Use of a small stem osseointegrated implant was found to reduce bone removal and provide more intramedullary space than a traditional implant; however, the higher the amputation site, the less medullary space was available regardless of implant type. Thus the stability of the endoprosthesis must be maximized while still maintaining enough residual space for the interface components. The results from this study provide an anatomic basis required for establishing a clinically applicable ONI in humans. They may serve as a guide for surgical implementation of an osseointegrated endoprosthesis with intramedullary electrodes for prosthetic control.
RESUMO
Familiarity with throwing mechanics during elbow range of motion allows accurate diagnosis of sports-related elbow injuries, which occur in predictable patterns. In addition, repetitive stress-related injuries are often clinically apparent; however, imaging plays an important role in determining severity as well as associated injuries that may affect clinical management. A detailed understanding of elbow imaging regarding anatomy and mechanism of injury results in prompt and precise treatment.
Assuntos
Traumatismos em Atletas , Ligamento Colateral Ulnar , Lesões no Cotovelo , Articulação do Cotovelo , Traumatismos em Atletas/diagnóstico por imagem , Beisebol , Ligamento Colateral Ulnar/lesões , Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/diagnóstico por imagem , HumanosRESUMO
Management options for small renal masses include active surveillance, partial nephrectomy, radical nephrectomy, and thermal ablation. For tumors typically ≤3 cm in size, thermal ablation is a good option for those desiring an alternative to surgery or active surveillance, especially in patients who are considered high surgical risk. We favor microwave ablation because of the more rapid heating, higher temperatures that overcome the heat sink effect of vessels, reproducible cell kill, and a highly visible ablation zone formed by water vapor that corresponds well to the zone of necrosis. For central tumors, we favor cryoablation because of the slower formation of the ablation zone and less likelihood of damage to the collecting system. With microwaves, it is important to monitor the ablation zone in real time (ultrasound is the best modality for this purpose), avoid direct punctures of the collecting system, and to place probes tangential to the collecting system to avoid burning open a persistent tract between the urothelium and extrarenal spaces or causing strictures. The surgical steps described in this video cover our use of high-frequency jet ventilation with general anesthesia to minimize organ motion, initial imaging and targeting, probe insertion, hydrodissection (a technique that enables displacement of adjacent structures), the ablation itself, and finally our dressing. Postoperative cares typically consist of observation with a same-day discharge or an overnight stay. Follow-up includes a magnetic resonance imaging abdomen with and without contrast, chest X-ray, and laboratories (basic metabolic panel, complete blood count, and C-reactive protein) 6 months postablation. Overall, percutaneous microwave ablation is an effective and safe treatment option for renal cell carcinoma in both T1a and T1b tumors in selected patients with multiple studies showing excellent oncologic outcomes when compared with partial and radical nephrectomy.
Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/cirurgia , Humanos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Micro-Ondas/uso terapêutico , Nefrectomia , Resultado do TratamentoRESUMO
Interpretation of increasingly complex imaging studies involves multiple intricate tasks requiring visual evaluation, cognitive processing, and decision-making. At each stage of this process, there are opportunities for error due to human factors including perceptual and ergonomic conditions. Investigation into the root causes of interpretive error in radiology first began over a century ago. In more recent work, there has been increasing recognition of the limits of human image perception and other human factors and greater acknowledgement of the role of the radiologist's environment in increasing the risk of error. This article reviews the state of research on perceptual and interpretive error in radiology. This article focuses on avenues for further error examination, and strategies for mitigating these errors are discussed. The relationship between artificial intelligence and interpretive error is also considered.
Assuntos
Erros de Diagnóstico/prevenção & controle , Ergonomia , Radiologia , Humanos , Interpretação de Imagem Assistida por Computador , Radiologia/métodos , Radiologia/normas , Radiologia/tendênciasRESUMO
Just as radiologic studies allow us to see past the surface to the vulnerable and broken parts of the human body, medical malpractice claims help us see past the surface of medical errors to the deeper vulnerabilities and potentially broken aspects of our healthcare delivery system. And just as the insights we gain through radiologic studies provide focus for a treatment plan for healing, so too can the analysis of malpractice claims provide insights to improve the delivery of safe patient care. We review 1325 coded claims where Radiology was the primary service provider to better understand the problems leading to patient harm, and the opportunities most likely to improve diagnostic care in the future.
Assuntos
Erros de Diagnóstico/estatística & dados numéricos , Revisão da Utilização de Seguros/estatística & dados numéricos , Imperícia/estatística & dados numéricos , Radiologia , Comunicação , Erros de Diagnóstico/economia , Humanos , Revisão da Utilização de Seguros/organização & administração , Responsabilidade Legal , Imperícia/economia , Imperícia/legislação & jurisprudênciaRESUMO
Hematologic disorders affect the central nervous system in a variety of ways, producing a wide range of neurologic disturbances. Early identification of these complications allows for early intervention and better outcome. Cross-sectional imaging plays an important role in identifying brain abnormalities and helps the clinician in deciding appropriate course of action and treatment. This article discuss in short the basics of hemostasis including the coagulation cascade and the application of basic laboratory tests in evaluation of hematologic function. Imaging features of various neurologic disorders associated with these clotting and bleeding diatheses are discussed in detail with illustrations.
Assuntos
Transtornos da Coagulação Sanguínea , Doenças do Sistema Nervoso Central , Hemorragia , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Transtornos da Coagulação Sanguínea/sangue , Transtornos da Coagulação Sanguínea/complicações , Transtornos da Coagulação Sanguínea/diagnóstico por imagem , Doenças do Sistema Nervoso Central/sangue , Doenças do Sistema Nervoso Central/diagnóstico por imagem , Doenças do Sistema Nervoso Central/etiologia , Hemorragia/sangue , Hemorragia/complicações , Hemorragia/diagnóstico por imagem , HumanosRESUMO
The cerebral ventricular system is intimately associated with the forebrain and brainstem. The ventricular system functions to produce and circulate cerebrospinal fluid, which plays an important role in mechanical protection and regulation of homeostasis in the central nervous system. This article discusses anatomy and neuroimaging of the ventricular system and highlights normal anatomical variations that may be mistaken for pathology. Applied surgical anatomy is reviewed with emphasis on operative approach and potential risk to adjacent central nervous system structures.