RESUMO
BACKGROUND: Digital modalities which enable asynchronous learning, such as audio podcasts and videos demonstrating procedures, may benefit acquisition and retention of knowledge and clinical skills. The main objective of this nationwide cross-sectional survey study was to evaluate key aspects and factors related to usage of audio podcasts and procedural videos in anaesthesiology and intensive care. METHODS: A 20-item multiple-choice-question online survey was created through a consensus process including pilot testing among residents and consultants. Data were collected over a 3-month period, September-November 2023. RESULTS: The survey was completed by 466 anaesthetists. More than a third reported using procedural videos ≥1 time per week, whereas fewer than one in four participants used audio podcasts at least once per week. Multivariable logistic regression analysis showed that working at a university hospital, male sex, and younger age were independently associated with podcast use ≥1 time per week, with the highest odds ratio (OR) for younger age (<40 years vs. ≥40 years old; OR 5.86 (95% confidence interval 3.55-9.67), p < .001). Younger age was also significantly associated with higher frequency of video use (OR 1.71 (1.13-2.58), p = .011), while working predominantly in intensive care was associated with a lower frequency of video use. Podcasts were often used during commuting (42.3%), household work (30.7%), and exercise (24.9%), indicating a role in multi-tasking. Approximately half of respondents expressed that audio podcast-based learning has a moderate to very large positive impact on acquisition of theoretical knowledge, as well as practical skills. A vast majority, 85.2%, reported that procedural videos have a moderate to very large impact on development of clinical skills. CONCLUSION: Audio podcasts and procedural videos are appreciated tools with potential to supplement more traditional didactic techniques in anaesthesiology and intensive care. Procedural video use is common, with perceived large effects on development of clinical skills. Further data are needed to fully understand learning outcomes, quality of peer-review processes, and potential sex-differences.
Assuntos
Anestesiologia , Cuidados Críticos , Gravação em Vídeo , Webcasts como Assunto , Humanos , Masculino , Feminino , Anestesiologia/educação , Suécia , Estudos Transversais , Adulto , Pessoa de Meia-Idade , Inquéritos e Questionários , Anestesistas/estatística & dados numéricos , Competência Clínica/estatística & dados numéricosRESUMO
BACKGROUND: Failed management of unanticipated difficult airway situations contributes to significant anesthesia-related morbidity and mortality. Optimization of design and layout of difficult airway trolleys (DATs) may influence outcomes during airway emergencies. The main objective of the current study was to evaluate whether a difficult airway algorithm-based DAT with integrated cognitive aids improves efficiency and team performance in difficult airway scenarios. METHODS: In a crossover design, 16 teams (anesthetist, nurse anesthetist, assistant nurse) completed two high-fidelity simulated unanticipated difficult airway scenarios. Teams used both an algorithm-based DAT and a comparison, standard DAT, in the scenarios and were randomized to order of trolley type. Outcome measures included objective efficiency parameters, team performance assessment and subjective user-ratings. Linear mixed models ANOVA, including DAT type and order of condition as main factors, was utilized for the primary analyses of the team results. RESULTS: Usage of the algorithm-based DAT was associated with fewer departures from the difficult airway algorithm (p = .010), and reduced number of unnecessary drawer openings (p = .002), but no significant differences in time to retrieval of airway devices or time to first effective ventilation, compared to the standard DAT. There were no significant differences in team performance, although participants expressed strong preference for the algorithm-based DAT (all user-rated measures p < .0001). Higher percentage of female members of the team improved adherence to the difficult airway algorithm (p = .043). CONCLUSIONS: Algorithm-based DATs with integrated cognitive aids may improve efficiency in difficult airway situations, compared to traditional DATs. These findings have implications for improvement of anesthetic practice.
Assuntos
Intubação Intratraqueal , Feminino , Humanos , Manuseio das Vias Aéreas/métodos , Anestesiologistas , Simulação por Computador , Estudos Cross-Over , Intubação Intratraqueal/métodosRESUMO
BACKGROUND: Airway complications account for almost one third of anaesthesia-related brain damage and death. Immediate access to equipment enabling rescue airway strategies is crucial for successful management of unanticipated difficult airway situations. METHODS: We conducted a nationwide survey of Swedish anaesthesiologists to analyse availability and organization of difficult airway trolleys (DATs), and multiple factors pertaining to difficult airway management, to highlight areas of potential improvement. RESULTS: Six hundred and thirty-nine anaesthesiologists completed the 14-item survey. Whereas DATs were almost ubiquitous (95%) in main operating departments of hospitals, prevalence was low in remote anaesthetizing locations (20.3%) and electroconvulsive therapy units (26.6%). Approximately 60% of emergency departments had a DAT. Immediate (within 60 seconds) access to videolaryngoscopes in all units where general anaesthesia is conducted was reported by 56.8%. Almost half of anaesthesiologists reported that all DATs at their workplace were standardized. Forty-six per cent reported that the DATs were organized according to a difficult airway algorithm; almost 90% believe that such an organization can impact the outcome of a difficult airway situation positively. Only 36.2% of DATs contained second-generation supraglottic airway devices exclusively. Most Swedish anaesthesiologists use the Swedish Society of Anaesthesiology and Intensive care Medicine difficult airway algorithm, but almost one fifth prefer the Difficult Airway Society algorithm. Less than half of respondents underwent formal difficult airway training annually. CONCLUSION: Our results motivate efforts to (a) increase availability of DATs in remote anaesthetizing locations, (b) increasingly standardize DATs and organize DATs according to airway algorithms, and (c) increase the frequency of difficult airway training.
Assuntos
Manuseio das Vias Aéreas/instrumentação , Anestesiologistas , Algoritmos , Estudos Transversais , Feminino , Pesquisas sobre Atenção à Saúde , Hospitais , Humanos , Masculino , SuéciaRESUMO
BACKGROUND: A modified heat-moisture exchanger that incorporates a reflecting filter for use with partial rebreathing of exhaled volatile anaesthetics has been commercially available since the 1990 s. The main advantages of the device are efficient delivery of inhaled sedation to intensive care patients and reduced anaesthetic consumption during anaesthesia. However, elevated arterial CO2 values have been observed with an anaesthetic conserving device compared with a conventional heat and moisture exchanger, despite compensation for larger apparatus dead space. OBJECTIVE: The objective of this study is to thoroughly explore the properties of two reflecting materials (charcoal and zeolites). DESIGN: A controlled, prospective, observational laboratory study. SETTING: Lund University Hospital, Sweden, from December 2011 to December 2012. PARTICIPANTS: None. INTERVENTIONS: Three filters, with identical volumes, were compared using different volatile anaesthetics at different conditions of temperature and moisture. The filtering materials were charcoal or zeolite. Glass spheres were used as an inert control. MAIN OUTCOME MEASURES: Consumption of volatile anaesthetics using different reflecting materials in filters at different conditions regarding temperature and moisture. CO2 reflection by the filtering materials: glass spheres, charcoal or zeolite. RESULTS: Isoflurane consumption in an open system was 60.8 g h(-1). The isoflurane consumption in dry, warm air was 39.8 g h(-1) with glass spheres. Changing to charcoal and zeolite had a profound effect on isoflurane consumption, 11.8 and 10.7 g h(-1), respectively. Heating and humidifying the air as well as the addition of N2O created only minor changes in consumption. The percentage of isoflurane conserved by the charcoal filter was independent of the isoflurane concentration (0.5 to 4.5%). Reflection of sevoflurane, desflurane and halothane by the charcoal filter was similar to reflection of isoflurane. Both charcoal and zeolite filters had CO2 reflecting properties and end-tidal CO2 increased by 3 to 3.7% compared with glass spheres. This increase was attenuated to 1 to 1.4% when the air was heated and humidified, and isoflurane was added. CONCLUSION: Charcoal and zeolite possess gas-reflecting properties, which can be used to conserve volatile anaesthetics. They also reflect CO2. The degree of CO2 reflection was reduced by heating and humidifying the air.
Assuntos
Filtros de Ar/normas , Anestesia por Inalação/instrumentação , Anestésicos Inalatórios/administração & dosagem , Carvão Vegetal/normas , Técnicas de Laboratório Clínico/normas , Zeolitas/normas , Anestesia por Inalação/métodos , Carvão Vegetal/química , Técnicas de Laboratório Clínico/instrumentação , Técnicas de Laboratório Clínico/métodos , Estudos Prospectivos , Zeolitas/químicaRESUMO
BACKGROUND: The anesthetic conserving device (ACD) reduces consumption of volatile anesthetic drug by a conserving medium adsorbing exhaled drug during expiration and releasing it during inspiration. Elevated arterial CO2 tension (PaCO2) has been observed in patients using the ACD, despite tidal volume increase to compensate for larger apparatus dead space. In a test lung using room temperature dry gas, this was shown to be due to adsorption of CO2 in the ACD during expiration and release of CO2 during the following inspiration. The effect in the test lung was higher than in patients. We tested the hypothesis that a lesser dead space effect in patients is due to higher temperature and/or moisture attenuating rebreathing of CO2. METHODS: The lungs of 6 postoperative cardiac surgery patients were ventilated using a conventional heat and moisture exchanger (HME) or an ACD. The ACD was studied with a test lung at varying temperatures and moistures. Infrared spectrometry was used to measure apparent dead space by the single-breath test for CO2 as well as rebreathing of CO2. RESULTS: In patients, the median apparent dead space was 136 mL (95% confidence interval [CI,] 120-167) larger using the ACD compared with an HME (after correction for difference in internal volume 100 and 50 mL, respectively). Median rebreathing of CO2 using the ACD was 53% (range 48-58) of exhaled CO2 compared with 29% (range 27-32) with an HME. The median difference in CO2 rebreathing was 23% (95% CI, 18-27). In the test lung apparent dead space using ACD was unaffected by body temperature but decreased from 360 to 260 mL when moisture was added. This decreased rebreathing of CO2 from 62% to 48%. CONCLUSIONS: The use of an ACD increases apparent dead space to a greater extent than can be explained by its internal volume. This is caused by adsorption of CO2 in the ACD during expiration and release of CO2 during inspiration. Rebreathing of CO2 was attenuated by moisture. The dead space effect of the ACD could be clinically relevant in acute respiratory distress syndrome and other diseases associated with ventilation difficulties, but investigations with larger sample sizes would be needed to determine the clinical importance.
Assuntos
Anestesia com Circuito Fechado/instrumentação , Anestesia por Inalação/instrumentação , Anestésicos Inalatórios/administração & dosagem , Pulmão/fisiologia , Respiração Artificial/instrumentação , Espaço Morto Respiratório , Ventiladores Mecânicos , Idoso , Testes Respiratórios , Dióxido de Carbono/metabolismo , Desenho de Equipamento , Expiração , Feminino , Humanos , Inalação , Pulmão/metabolismo , Masculino , Pessoa de Meia-Idade , Temperatura , Fatores de TempoRESUMO
Death and severe morbidity attributable to anesthesia are commonly associated with failed difficult airway management. When an airway emergency develops, immediate access to difficult airway equipment is critical for implementation of rescue strategies. Previously, national expert consensus guidelines have provided only limited guidance for the design and setup of a difficult airway trolley. The overarching aim of the current work was to create a dedicated difficult airway trolley (for patients>12 years old) for use in anesthesia theatres, intensive care units, and emergency departments. A systematic literature search was performed, using the PubMed, Embase, and Google Scholar search engines. Based on evidence presented in 11 national or international guidelines, and peer-reviewed journals, we present and outline a difficult airway trolley organized to accommodate sequential progression through a four-step difficult airway algorithm. The contents of the top four drawers correspond to specific steps in the airway algorithm (A = intubation, B = oxygenation via a supraglottic airway device, C = facemask ventilation, and D = emergency invasive airway access). Additionally, specialized airway equipment may be included in the fifth drawer of the proposed difficult airway trolley, thus enabling widespread use. A logically designed, guideline-based difficult airway trolley is a vital resource for any clinician involved in airway management and may aid the adherence to difficult airway algorithms during evolving airway emergencies. Future research examining the availability of rescue airway devices in various clinical settings, and simulation studies comparing different types of difficult airway trolleys, are encouraged.