Stroke ; 53(6): 1863-1872, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35135323

RESUMO

BACKGROUND: We evaluated data from all patients in the Netherlands who underwent endovascular treatment for acute ischemic stroke in the past 3.5 years, to identify nationwide trends in time to treatment and procedural success, and assess their effect on clinical outcomes. METHODS: We included patients with proximal occlusions of the anterior circulation from the second and first cohorts of the MR CLEAN (Multicenter Randomized Clinical trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands) Registry (March 2014 to June 2016; June 2016 to November 2017, respectively). We compared workflow times and rates of successful reperfusion (defined as an extended Thrombolysis in Cerebral Infarction score of 2B-3) between cohorts and chronological quartiles (all included patients stratified in chronological quartiles of intervention dates to create equally sized groups over the study period). Multivariable ordinal logistic regression was used to assess differences in the primary outcome (ordinal modified Rankin Scale at 90 days). RESULTS: Baseline characteristics were similar between cohorts (second cohort n=1692, first cohort n=1488) except for higher age, poorer collaterals, and less signs of early ischemia on computed tomography in the second cohort. Time from stroke onset to groin puncture and reperfusion were shorter in the second cohort (median 185 versus 210 minutes; P<0.001 and 236 versus 270 minutes; P<0.001, respectively). Successful reperfusion was achieved more often in the second than in the first cohort (72% versus 66%; P<0.001). Functional outcome significantly improved (adjusted common odds ratio 1.23 [95% CI, 1.07-1.40]). This effect was attenuated by adjustment for time from onset to reperfusion (adjusted common odds ratio, 1.12 [95% CI, 0.98-1.28]) and successful reperfusion (adjusted common odds ratio, 1.13 [95% CI, 0.99-1.30]). Outcomes were consistent in the analysis per chronological quartile. CONCLUSIONS: Clinical outcomes after endovascular treatment for acute ischemic stroke in routine clinical practice have improved over the past years, likely resulting from improved workflow times and higher successful reperfusion rates.


Assuntos
Isquemia Encefálica , Procedimentos Endovasculares , AVC Isquêmico , Acidente Vascular Cerebral , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/cirurgia , Procedimentos Endovasculares/métodos , Humanos , Estudos Longitudinais , Sistema de Registros , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Trombectomia/métodos , Resultado do Tratamento
2.
Eur J Nucl Med Mol Imaging ; 37(12): 2328-33, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20683591

RESUMO

PURPOSE: 90Y microspheres are used for intra-arterial treatment of liver tumours. In the patient preparation, a hepatic angiogram is performed and all arteries that could transport microspheres from the targeted liver vasculature to extrahepatic organs are blocked. 99mTc-labelled macroaggregated albumin (MAA) is injected intra-arterially to simulate the treatment and whole-body scintigraphy and single photon emission computed tomography (SPECT) of the abdomen are performed. METHODS: Various aspects of lung shunt fraction (LSF) estimation were studied: interobserver and intrapatient variability, influence of scan quality and underlying disease. Secondly, the interobserver variability in reading the MAA SPECT of the abdomen was investigated. We reviewed 90 whole-body scans and 20 SPECT scans performed at our institution. Readers were blinded to each other's findings. Scoring the scan quality was based on the visualization of tracer degradation. RESULTS: The mean difference in LSF between the readers was 1%. In 1 of 23 patients who underwent repeated MAA injections a marked change in LSF was observed. No significant differences in LSF were recorded for primary versus secondary liver tumours. There was a correlation between scan quality and LSF, suggesting that low scan quality leads to overestimation of the LSF. Concordant results in ruling out the presence of extrahepatic tracer deposition were reached in 17 of 20 scans (85%). CONCLUSION: Interobserver and intrapatient variability in LSF calculation was limited. LSF was clearly dependent on scan quality. The underlying disease had no significant impact on the LSF. Interobserver variability for reading the MAA SPECT scans was acceptable.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Agregado de Albumina Marcado com Tecnécio Tc 99m , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Imagem Corporal Total/métodos , Radioisótopos de Ítrio/uso terapêutico , Humanos , Microesferas , Compostos Radiofarmacêuticos/uso terapêutico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Cardiovasc Intervent Radiol ; 35(5): 1172-80, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21979794

RESUMO

PURPOSE: Portal vein embolization is performed to increase the future liver remnant before liver surgery in patients with liver malignancies. This study assesses the feasibility of a transsinusoidal approach for portal vein embolization (PVE) with the ethylene vinyl alcohol copolymer, Onyx. METHODS: Indirect portography through contrast injection in the cranial mesenteric artery was performed in eight healthy pigs. Onyx was slowly injected through a microcatheter from a wedged position in the hepatic vein and advanced through the liver lobules into the portal system. The progression of Onyx was followed under fluoroscopy, and the extent of embolization was monitored by indirect portography. The pigs were euthanized immediately (n = 2), at 7 days (n = 4), or at 21 days postprocedure (n = 2). All pigs underwent necropsy and the ex vivo livers were grossly and histopathologically analyzed. RESULTS: Transsinusoidal PVE was successfully performed in five of eight pigs (63%). In 14 of 21 injections (67%), a segmental portal vein could be filled completely. A mean of 1.6 liver lobes per pig was embolized (range 1-2 lobes). There were no periprocedural adverse events. Focal capsular scarring was visible on the surface of two resected livers, yet the capsules remained intact. Histopathological examination showed no signs of recanalization or abscess formation. Mild inflammatory reaction to Onyx was observed in the perivascular parenchyma. CONCLUSIONS: The porcine portal vein can be embolized through injection of Onyx from a wedged position in the hepatic vein. Possible complications of transsinusoidal PVE and the effect on contralateral hypertrophy need further study.


Assuntos
Dimetil Sulfóxido/farmacologia , Embolização Terapêutica/métodos , Polivinil/farmacologia , Veia Porta , Animais , Meios de Contraste/administração & dosagem , Dimetil Sulfóxido/administração & dosagem , Estudos de Viabilidade , Feminino , Fluoroscopia , Polivinil/administração & dosagem , Portografia , Suínos