Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39243285

RESUMO

OBJECTIVE: To evaluate changes in choroidal thickness in presbyopes, when reading with regular glasses versus choroidal control glasses, in patients with or without Age-Related Macular Degeneration (AMD). METHODS: This was a pilot study on short-term axial length (AL) in 33 eyes of 24 presbyopic patients aged 60 to 80 years, assigned to two age-matched groups, with or without AMD. About them, changes in choroidal thickness were evaluated with ocular biometry through indirect measurements of axial length at baseline, after 20' of reading with conventional lenses, and after another 20' of reading with peripheral hyperopic defocus glasses. The differences in axial length between the three different times were analyzed. RESULTS: In presbyopes without AMD there was a significant axial length shortening of -13.44 microns in the first conventional reading period, which was reversed by 90% with hyperopic defocus lenses, recovering + 12.11 microns by axial lengthening (choroidal thinning, p = 0.03). In patients with AMD, axial shortening was significantly greater than controls, -23.86 microns with conventional lenses (p < 0.001) and they, also increased their axial length with defocus, although this response was smaller in proportion (+ 15.52 microns). CONCLUSION: Reading with positive lenses produces myopic defocus and choroidal thickening in presbyopes with and without AMD but was significantly greater in the latter. Glasses with Choroidal Control Technology reduced thickening during reading. KEY MESSAGES: What is known • Presbyopia spectacles for near produce myopic defocus and choroidal thickening. What is new • There are differences in choroidal thickening during reading between normal subjects and those with age related macular degeneration. • Spectacles with Defocus Choroidal Control Technology reduce choroidal thickening during reading in presbyopes.

2.
Ophthalmic Physiol Opt ; 44(1): 214-218, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37642972

RESUMO

PURPOSE: To analyse ocular coherence tomography (OCT) images of the retinal shadows caused by defocus and diffusion optics spectacles. METHODS: One eye was fitted successively with the Hoya Defocus Incorporated Multiple Segments (DIMS) spectacle lens, two variations of the +3.50 D peripheral add spectacle (DEFOCUS) and the low-contrast dot lens (Diffusion Optics Multiple Segments, DOMS); each at a vertex distance of 12 mm. Simultaneously, a retinal image of the macular region with central fixation was obtained using infrared OCT. The corneal power and intraocular distances were determined using an optical biometer. RESULTS: The retinal images for the DIMS and DOMS lenses showed patterns of obvious retinal shadows in the periphery, while the central 10-11° remained clear. The DEFOCUS lens produced a darkened peripheral area. Dividing the size of the retinal pattern, measured with the calliper of the OCT software, by the actual size on the spectacle lens gave a magnification of -0.57 times. This is consistent with the incoming OCT beam being imaged to a position approximately 31 mm beyond the front of the eye. [Correction added on 26 October 2023 after first online publication: The preceding paragraph was corrected.] CONCLUSION: With device-specific correction, retinal OCT images can help visualise the regions affected by the defocus or lowered contrast induced by myopia control spectacles. This is of potential value for improving myopia therapies.


Assuntos
Cristalino , Miopia , Humanos , Refração Ocular , Óculos , Miopia/terapia , Retina/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA