Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 125
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38587017

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , América Latina , Resultado do Tratamento , Catéteres , Ásia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
2.
Circulation ; 144(20): 1590-1597, 2021 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-34780252

RESUMO

BACKGROUND: Prescription opioids are a major contributor to the ongoing epidemic of persistent opioid use (POU). The incidence of POU among opioid-naïve patients after cardiac implantable electronic device (CIED) procedures is unknown. METHODS: This retrospective cohort study used data from a national administrative claims database from 2004 to 2018 of patients undergoing CIED procedures. Adult patients were included if they were opioid-naïve during the 180-day period before the procedure and did not undergo another procedure with anesthesia in the next 180 days. POU was defined by filling an additional opioid prescription >30 days after the CIED procedure. RESULTS: Of the 143 400 patients who met the inclusion criteria, 15 316 (11%) filled an opioid prescription within 14 days of surgery. Among these patients, POU occurred in 1901 (12.4%) patients 30 to 180 days after surgery. The likelihood of developing POU was increased for patients who had a history of drug abuse (odds ratio, 1.52; P=0.005), preoperative muscle relaxant (odds ratio, 1.52; P<0.001) or benzodiazepine (odds ratio, 1.23; P=0.001) use, or opioid use in the previous 5 years (OR, 1.76; P<0.0001). POU did not differ after subcutaneous implantable cardioverter defibrillator or other CIED procedures (11.1 versus 12.4%; P=0.5). In a sensitivity analysis excluding high-risk patients who were discharged to a facility or who had a history of drug abuse or previous opioid, benzodiazepine, or muscle relaxant use, 8.9% of the remaining cohort had POU. Patients prescribed >135 mg of oral morphine equivalents had a significantly increased risk of POU. CONCLUSIONS: POU is common after CIED procedures, and 12% of patients continued to use opioids >30 days after surgery. Higher initially prescribed oral morphine equivalent doses were associated with developing POU.


Assuntos
Analgésicos Opioides/uso terapêutico , Desfibriladores Implantáveis , Cuidados Pós-Operatórios , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/efeitos adversos , Tomada de Decisão Clínica , Bases de Dados Factuais , Gerenciamento Clínico , Prescrições de Medicamentos/normas , Prescrições de Medicamentos/estatística & dados numéricos , Duração da Terapia , Pesquisas sobre Atenção à Saúde , Humanos , Vigilância em Saúde Pública
3.
J Cardiovasc Electrophysiol ; 32(2): 345-353, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33382500

RESUMO

INTRODUCTION: Oral anticoagulation (OAC) based on estimated stroke risk is recommended following catheter ablation (CA) of atrial fibrillation (AF), regardless of the extent of arrhythmia control. However, discontinuing OAC in selected patients may be safe. We sought to evaluate a strategy of OAC discontinuation following AF ablation guided by continuous rhythm monitoring. METHODS AND RESULTS: We prospectively studied AF ablations performed at our institution from June 2015 to December 2019. Patients that had pre-existing cardiac implantable electronic devices (CIEDs) or underwent insertable cardiac monitor (ICM) implantation immediately following AF ablation were included. OAC was continued for 6 weeks following CA in all patients, following which OAC management was guided by CHA2 DS2 -VASc score and continuous rhythm monitoring results, according to a prespecified protocol. AF recurrence was defined as ≥30 s (CIEDs) or ≥2 min (ICM). We studied 196 patients (mean age 64.7 ± 11.3 years, 66.8% male, 85.7% ICM, 14.3% CIEDs). Mean CHA2 DS2- VASc score was 2.2 ± 1.5. One-year AF-free survival following CA was 83% for paroxysmal AF and 63% for persistent AF patients. Over 3 year follow-up, OAC was discontinued in 57 (33.7%) patients, mean 7.4 ± 7.1 months following ablation. Following discontinuation, OAC was restarted for AF recurrence in 9 (15.8%) patients, mean 11.7 ± 6.8 months after stopping. This discontinuation protocol led to a 21.9% reduction in overall time exposed to OAC. There were no thromboembolic or major bleeding events. CONCLUSION: OAC can be discontinued in a significant percentage of patients following CA of AF. When guided by continuous rhythm monitoring, this practice does not unacceptably increase the risk of thromboembolic events.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Tromboembolia , Administração Oral , Idoso , Anticoagulantes/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 31(2): 423-431, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31916273

RESUMO

BACKGROUND: We have previously demonstrated the feasibility of a nurse-led risk factor modification (RFM) program for improving weight loss and obstructive sleep apnea (OSA) care among patients with atrial fibrillation (AF). OBJECTIVE: We now report its impact on arrhythmia outcomes in a subgroup of patients undergoing catheter ablation. METHODS: Participating patients with obesity and/or need for OSA management (high risk per Berlin Questionnaire or untreated OSA) underwent in-person consultation and monthly telephone calls with the nurse for up to 1 year. Arrhythmias were assessed by office ECGs and ≥2 wearable monitors. Outcomes, defined as Arrhythmia control (0-6 self-terminating recurrences, with ≤1 cardioversion for nonparoxysmal AF) and Freedom from arrhythmias (no recurrences on or off antiarrhythmic drugs), were compared at 1 year between patients undergoing catheter ablation who enrolled and declined RFM. RESULTS: Between 1 November 2016 and 1 April 2018, 195 patients enrolled and 196 declined RFM (body mass index, 35.1 ± 6.7 vs 34.3 ± 6.3 kg/m2 ; 50% vs 50% paroxysmal AF; P = NS). At 1 year, enrolled patients demonstrated significant weight loss (4.7% ± 5.3% vs 0.3% ± 4.4% in declined patients; P < .0001) and improved OSA care (78% [n = 43] of patients diagnosed with OSA began treatment). However, outcomes were similar between enrolled and declined patients undergoing ablation (arrhythmia control in 80% [n = 48] vs 79% [n = 38]; freedom from arrhythmia in 58% [n = 35] vs 71% [n = 34]; P = NS). CONCLUSION: Despite improving weight loss and OSA care, our nurse-led RFM program did not impact 1-year arrhythmia outcomes in patients with AF undergoing catheter ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Papel do Profissional de Enfermagem , Obesidade/enfermagem , Comportamento de Redução do Risco , Apneia Obstrutiva do Sono/enfermagem , Idoso , Antiarrítmicos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Índice de Massa Corporal , Ablação por Cateter/efeitos adversos , Dieta Saudável/enfermagem , Exercício Físico , Feminino , Nível de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/diagnóstico , Obesidade/fisiopatologia , Educação de Pacientes como Assunto , Avaliação de Programas e Projetos de Saúde , Recidiva , Fatores de Risco , Sono , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Redução de Peso
5.
J Cardiovasc Electrophysiol ; 30(11): 2326-2333, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31424129

RESUMO

BACKGROUND: Catheter ablation (CA) of idiopathic premature ventricular complexes (PVCs) is typically guided by both activation and pace-mapping, with ablation ideally delivered at the site of the earliest local activation. However, activation mapping requires sufficient intraprocedural quantity of PVCs. This study aimed to investigate the outcome of CA of infrequent PVCs guided exclusively by pace-mapping. METHODS: We retrospectively analyzed all patients undergoing CA of idiopathic PVCs between 2014 and 2017. RESULTS: Among 327 patients, 24 (7.3%) had low intraprocedural PVC burden despite isoproterenol, including two patients with zero PVCs, rendering activation mapping impractical/impossible. All 24 had a history of symptomatic PVCs. During ablation, a median of 27 (17-55) pace-maps were performed, with best median PASO score of 97 (96-98)%. A median of 12 (8.75-18.75) radiofrequency (RF) lesions were delivered with 11.4 (8.5-17.6) minutes of total RF time. Clinical success, defined as more than 80% reduction in the burden of previously frequent PVCs and/or absence of symptoms as well as any documented clinical PVCs among those with infrequent or exercise-induced PVCs, was achieved in 19 (79%) patients over 9.2 (2.0-15.0) months of follow-up. CONCLUSIONS: When activation mapping cannot be performed due to inadequate intraprocedural PVC burden, detailed pace-mapping can frequently identify the precise arrhythmia site of origin, thereby guiding successful CA.


Assuntos
Potenciais de Ação , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Complexos Ventriculares Prematuros/cirurgia , Adulto , Idoso , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/fisiopatologia
6.
J Cardiovasc Electrophysiol ; 30(6): 865-876, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30834593

RESUMO

INTRODUCTION: Nonpulmonary vein (non-PV) triggers of atrial fibrillation (AF) are targets for ablation but their localization remains challenging. The aim of this study was to describe P-wave (PW) morphologic characteristics and intra-atrial activation patterns and timing from multipolar coronary sinus (CS) and crista terminalis (CT) catheters that localize non-PV triggers. METHODS AND RESULTS: Selective pacing from six right and nine left atrial common non-PV trigger sites was performed in 30 consecutive patients. We analyzed 12 lead ECG features based on PW duration, amplitude and morphology, and patterns and timing of multipolar activation for all 15 sites. Regionalization and then precise localization required criteria present in at least 70% of assessments at each pacing site. The algorithm was then prospectively evaluated by four blinded observers in a validation cohort of 18 consecutive patients undergoing the same pacing protocol and 60 consecutive patients who underwent successful non-PV trigger ablation. The algorithm for site regionalization included 1) negative PW in V1, ≥30 µV change in PW amplitude across the leads V1-V3, and PW duration ≤100 milliseconds in lead 2 and 2) unique intra-atrial activation patterns and timing noted in the multipolar catheters. Specific ECG and intra-atrial activation timing characteristics included in the algorithm allowed for more precise site localization after regionalization. In the prospective evaluation, the algorithm identified the site of origin for 72% of paced and 70% of spontaneous non-PV trigger sites. CONCLUSION: An algorithm based on PW morphology and intra-atrial multipolar activation pattern and timing can help identify non-PV trigger sites of origin.


Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Veias Pulmonares/fisiopatologia , Idoso , Algoritmos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/cirurgia , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Fatores de Tempo
7.
Europace ; 21(3): 484-491, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30535322

RESUMO

AIMS: Catheter ablation of outflow tract ventricular arrhythmias (OTVAs) with the earliest activation within the coronary venous system (CVS) can be challenging. When ablation from the CVS is not feasible or ineffective, an approach from anatomically adjacent site(s) can be considered. We report the outcomes of an anatomical approach for OTVAs linked to the CVS. METHODS AND RESULTS: We retrospectively analysed 665 OTVA patients. Of these, 65 (9.8%) had the earliest activation within the CVS. In 53 (82%) cases, an anatomical approach was attempted. The targeted adjacent anatomical structure was the endocardial left ventricular outflow tract (LVOT) in 24 (45%), the left coronary cusp or the left/right cusp junction in 17 (32%) patients, and the right ventricular outflow tract (RVOT) in 12 (23%). The anatomical approach was successful in 26 (49%) patients (27% from the coronary cusps, 65% from the LVOT, and 8% from the RVOT). The difference in activation times between the earliest activation site within the CVS and the targeted site was not significantly different between the successful and unsuccessful groups (14.2 ± 11.2 ms vs. 13.2 ± 9.3 ms; P = 0.89). The anatomical distance from the earliest activation site to the targeted site was shorter for the successful group (9.7 ± 2.4 mm vs. 13.1 ± 6.5 mm; P < 0.05). In particular, when the anatomical distance was >12.8 mm, anatomical approach was successful in only 1/13 (8%). CONCLUSION: In patients with OTVAs linked to the CVS, an anatomical approach targeting an adjacent site can be effective, particularly when the distance between the sites is <12.8 mm.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter , Vasos Coronários/fisiopatologia , Ventrículos do Coração/cirurgia , Potenciais de Ação , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Ablação por Cateter/efeitos adversos , Bases de Dados Factuais , Feminino , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
8.
Pacing Clin Electrophysiol ; 42(3): 333-340, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30656717

RESUMO

BACKGROUND: Noninducibility of ventricular tachycardia (VT) at noninvasive programmed stimulation performed shortly following ablation (negative NIPS) predicts low risk of the medium-term recurrence. This study aimed to evaluate long-term rate and mode of recurrence following negative NIPS. METHODS: We extended follow-up on patients in whom no VT could be induced at NIPS following ablation between 2008 and 2010. Recurrent VTs were categorized as "Original clinical" if they matched VT that had occurred spontaneously prior to the index ablation; "Original nonclinical" if they matched VT that was induced during the index ablation but had not occurred spontaneously; or "New." Among those undergoing repeat ablation, the area ablated to treat the recurrent VT was categorized as "Targeted initial scar" if it was targeted during the index procedure; "Untargeted initial scar" if it was present but not targeted during the index procedure; or "New scar" if it was not present during the index procedure. RESULTS: Of 60 patients with negative NIPS, 18 (30%) had recurrent VT and nine underwent repeat ablation over (4.1 ± 3.2) years follow-up. Of 23 recurrent VTs, 18 (78%) were "New." During repeat ablations, six (46%) of the 13 recurrent VTs were ablated in "untargeted initial scar" and four (31%) in "new scar." CONCLUSIONS: When spontaneous or inducible VTs are eliminated with ablation and no longer inducible during NIPS, these VTs are unlikely to recur during long-term follow-up. More commonly, new VTs occur, which are either associated with areas of scar not present or not targeted during the initial ablation.


Assuntos
Ablação por Cateter/métodos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva
9.
J Cardiovasc Electrophysiol ; 29(12): 1664-1671, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30176074

RESUMO

INTRODUCTION: In patients with monomorphic idiopathic outflow tract ventricular arrhythmias (OT-VAs), catheter ablation (CA) at the earliest activation site can result in a shift in QRS morphology indicating a change in the activation patterns. This study aimed to investigate the prevalence, mapping features, and ablation outcomes of OT-VAs displaying a QRS morphology shift following CA. METHODS AND RESULTS: We retrospectively analyzed 446 patients with monomorphic OT-VAs. A QRS morphology shift following CA was observed in 17 (4%) patients. Initially, the earliest activation site was within the right ventricular outflow tract (RVOT) in one (6%) patient, the left ventricular outflow tract (LVOT) in 10 (59%) patients (left coronary cusp/right coronary cusp junction in seven patients and LVOT endocardium in three patients), and within the distal coronary venous system in six (35%) patients. The VA was suppressed in all 17 patients, but VA recurrence with a different QRS morphology was observed after a waiting period. The recurrent VA was remapped in all patients and was eliminated targeting the new earliest site in 15 (88%) cases. In 11 of 15 successful cases, the ablation site for the recurrent VA shifted to an anatomical structure distinct from but adjacent to the initial site. In the remaining four patients, the recurrent VA was eliminated within the same anatomical structure. CONCLUSIONS: In patients with idiopathic OT-VAs, a QRS morphology shift following CA can be observed in 4% of the cases. In these cases, detailed remapping is necessary since the successful ablation site for the VAs with altered QRS morphology shifts to different anatomical structures in most patients.


Assuntos
Ablação por Cateter/tendências , Eletrocardiografia/tendências , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Taquicardia Ventricular/epidemiologia , Resultado do Tratamento
10.
J Cardiovasc Electrophysiol ; 29(11): 1515-1522, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30230106

RESUMO

INTRODUCTION: Differentiation of right versus left ventricular outflow tract (RVOT vs. LVOT) arrhythmia origin with left bundle branch block right inferior axis (LBRI) morphology is relevant to ablation planning and risk discussion. Our aim was to determine if lead I R-wave amplitude is useful for differentiation of RVOT from LVOT arrhythmias with LBRI morphology. METHODS: The R-wave amplitude in lead I was measured in a retrospective cohort of 75 consecutive patients with LBRI pattern ventricular arrhythmias (VAs) successfully ablated from the RVOT (n = 54), LVOT (n = 16), or the anterior interventricular vein (AIV; n = 5). The optimal R-wave threshold was identified and diagnostic indices were compared with the previously reported transitional zone (TZ) index and V2S/V3R index. RESULTS: An R-wave amplitude greater than or equal to 0.1 mV predicted LVOT origin with 75% sensitivity and 98.2% specificity. In comparison, the TZ and V2S/V3R indices had 50% and 68.8% sensitivity, and 75.9% and 88.9% specificity, respectively, for predicting LVOT origin. The area under the curve (AUC) was 0.85 for lead I R-wave amplitude, 0.87 for V2S/V3R, and 0.72 for the TZ index. Of 36 cases with QS in lead I, 30 (83.3%) were from the anterior RVOT, three (8.3%) from the LVOT, and three (8.3%) from the AIV. CONCLUSION: The presence of R-wave amplitude in lead I (≥0.1 mV) is a simple and useful criterion to identify LVOT cusp or endocardium focus in LBRI arrhythmias. A QS pattern in lead I suggests an origin in the anterior RVOT, or less commonly the adjacent LV summit.


Assuntos
Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Eletrocardiografia/métodos , Ventrículos do Coração/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Adulto , Idoso , Ablação por Cateter/métodos , Estudos de Coortes , Eletrocardiografia/instrumentação , Eletrodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
11.
J Cardiovasc Electrophysiol ; 29(11): 1530-1539, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30230120

RESUMO

INTRODUCTION: The characteristics of the epicardial (EPI) substrate responsible for ventricular tachycardia (VT) in ischemic cardiomyopathy (ICM) are undefined, and data on the long-term outcomes of EPI catheter ablation limited. We evaluated the prevalence, electrophysiologic features, and outcomes of catheter ablation of EPI VT in ICM. METHODS AND RESULTS: From December 2010 to June 2013, a total of 13 of 93 (14%) patients with ICM underwent catheter ablation at our institution and had conclusive evidence of critical EPI substrate demonstrated to participate in VT with activation, entrainment and/or pace mapping during sinus rhythm (two other patients underwent EPI mapping but had no optimal ablation targets). The electrophysiologic substrate characteristics and activation/entrainment mapping data were compared with a reference group of ICM patients without evidence of critical EPI substrate (N = 44), defined as a complete procedural success (noninducibility of any VT at programmed stimulation) after endocardial (ENDO)-only ablation. Patients with failed EPI access (N = 2) or history of cardiac surgery (N = 92) were excluded from the study. All 13 patients had evidence of abnormal EPI substrate with fractionated/late/split electrograms and low-bipolar voltage areas. The critical VT ablation sites were all located within the EPI bipolar "dense" scar (<1.0 mV) opposite the ENDO bipolar scar in 77% of cases and extending beyond the ENDO bipolar scar (within the ENDO unipolar low-voltage area) in the remaining patients. Compared with the reference ENDO-only group, patients with EPI VT had a smaller ENDO bipolar scar area, 54.0 (37.1-84) vs 86.7 (55.6-112) cm2 ; P = 0.0159, with a similar extent of ENDO unipolar low voltage. No other substrate characteristics or location differed between the two groups. After 35.2 ± 24.2 months of follow-up, VT-free survival was 73% in patients with EPI VT compared with 66% in the ENDO-only group (log-rank P = 0.56). CONCLUSIONS: The presence of the critical EPI substrate responsible for VT can be demonstrated in at least 14% of patients with ICM. The majority of EPI critical ablation sites are distributed opposite the ENDO bipolar scar area and catheter ablation is effective in achieving long-term arrhythmia control.


Assuntos
Cardiomiopatias/epidemiologia , Ablação por Cateter/tendências , Eletrocardiografia/tendências , Isquemia Miocárdica/epidemiologia , Taquicardia Ventricular/epidemiologia , Idoso , Cardiomiopatias/fisiopatologia , Cardiomiopatias/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/cirurgia , Prevalência , Estudos Retrospectivos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 29(12): 1654-1663, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30106213

RESUMO

BACKGROUND: Catheter ablation of ventricular arrhythmias (VA) from the papillary muscles (PM) is challenging due to limited catheter stability and contact on the PMs with their anatomic complexity and mobility. OBJECTIVE: This study aimed to evaluate the effectiveness of cryoablation as an adjunctive therapy for PM VAs when radiofrequency (RF) ablation has failed. METHODS: We evaluated a retrospective series of patients who underwent cryoablation for PM VAs when RF ablation had failed. The decision to switch to cryoablation was at the operator's discretion when intracardiac echocardiography (ICE) suggested that cryoablation might be more effective in achieving catheter stability and energy delivery. RESULTS: Sixteen patients underwent cryoablation of PM VAs between 2014 and 2016 after RF ablation was unsuccessful. VAs originated from the anterolateral left ventricle (LV) PM (six patients), posterolateral LV PM (six patients), and right ventricle PM (four patients). VAs were predominantly frequent premature ventricular complexes (PVCs); however, patients with sustained ventricular tachycardia and PVC-triggered VF were also represented. Fifteen of the 16 patients were treated with cryoablation; in one patient, a procedural complication with retrograde aortic access precluded treatment. In all patients treated with cryoablation, contact and stability was confirmed with ICE to be superior to the RF catheter, and there was acute and long-term elimination of VAs. CONCLUSION: Cryoablation is a useful adjunctive therapy in ablation of PM VAs, providing excellent procedural outcomes even when RF ablation has failed. Cryoablation catheters are less maneuverable than RF ablation catheters and care is required to avoid complications.


Assuntos
Ablação por Cateter/métodos , Criocirurgia/métodos , Músculos Papilares/diagnóstico por imagem , Músculos Papilares/cirurgia , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Estudos Retrospectivos , Taquicardia Ventricular/fisiopatologia , Falha de Tratamento , Adulto Jovem
13.
J Cardiovasc Electrophysiol ; 29(1): 146-153, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29059484

RESUMO

BACKGROUND: Mitral valve prolapse has been associated with increased risk of ventricular arrhythmias. We aimed to examine whether certain cardiac imaging characteristics are associated with papillary muscle origin of ventricular arrhythmias in these patients. METHODS AND RESULTS: We screened electronic medical records of all patients documented to have mitral valve prolapse on either transthoracic echocardiogram (TTE) or cardiac magnetic resonance imaging (CMR) in our center, who also underwent an electrophysiologic study (EPS) between 2007 and 2016. Anterior and posterior mitral leaflet thickness and prolapsed distance were measured on TTE and late gadolinium enhancement (LGE) was assessed on CMR. Patients were categorized as papillary muscle positive (pap (+)) or negative (pap (-)) using EPS. Eighteen patients were included in this study. Of the 15 patients who underwent TTE, a significantly higher proportion of patients in the pap (+) group had an anterior to posterior leaflet prolapse ratio of >0.45 indicating more symmetric leaflet prolapse. There were no differences in anterior or posterior leaflet thickness or prolapse distance between the groups. Patients in the pap (+) group were more likely to be women. Of the 7 patients who underwent CMR, those who were pap (+) were more likely to have LGE in the region of the papillary muscles than those who were pap (-). CONCLUSION: Female gender, more symmetric bileaflet prolapse on TTE, and the presence of papillary muscle LGE on CMR may be associated with papillary muscle origin of ventricular arrhythmias in patients with mitral valve prolapse.


Assuntos
Ecocardiografia , Imagem Cinética por Ressonância Magnética , Prolapso da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Músculos Papilares/diagnóstico por imagem , Taquicardia Ventricular/diagnóstico por imagem , Adulto , Idoso , Bases de Dados Factuais , Eletrocardiografia , Registros Eletrônicos de Saúde , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Prolapso da Valva Mitral/complicações , Prolapso da Valva Mitral/fisiopatologia , Músculos Papilares/fisiopatologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Fatores Sexuais , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia
14.
J Cardiovasc Electrophysiol ; 29(6): 823-832, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29513397

RESUMO

INTRODUCTION: Whether successful catheter ablation for atrial fibrillation (AF) reduces risk of cerebrovascular events (CVEs) remains controversial and whether oral anticoagulation therapy (OAT) can be safely discontinued in patients rendered free of AF recurrences remains unknown. We evaluated OAT use patterns and examined long-term rates of CVEs (stroke/TIA) and major bleeding episodes (MBEs) in patients with nonparoxysmal AF treated with catheter ablation. METHODS AND RESULTS: Four hundred patients with nonparoxysmal AF (200 persistent, 200 longstanding persistent; mean age 60.3 ± 9.7 years, 82% male) undergoing first AF ablation were followed for 3.6 ± 2.4 years. OAT discontinuation during follow-up was permitted in selected patients per physician discretion. At last follow-up, allowing for multiple ablations, 172 (43.0%) patients were free of AF recurrence. Two hundred and seven (51.8%) discontinued OAT at some point; 174 (43.5%) were off OAT at last follow-up. Patients without AF recurrence were more likely to remain off OAT (HR 0.23 [95% CI 0.17-0.33]). Patients with persistent (versus longstanding persistent) AF type prior to ablation (HR 0.6 [CI 0.44-0.83]) and those with CHA2 DS2 -VASc score <2 (HR 0.56 [0.39-0.80]) were less likely to continue OAT. Seven patients had CVEs (incidence: 0.49/100 patient years) and 14 experienced MBE during follow-up (incidence: 0.98/100 patient years). Older age (P  =  0.001) and coronary artery disease (P  =  0.028) were associated with CVE. CONCLUSION: Anticoagulation discontinuation in well selected, closely monitored patients following successful ablation of nonparoxysmal AF was associated with a low rate of clinical embolic CVEs. Prospective studies are required to confirm safety of OAT discontinuation after successful AF ablation.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/terapia , Ablação por Cateter , Ataque Isquêmico Transitório/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Esquema de Medicação , Feminino , Hemorragia/induzido quimicamente , Humanos , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/fisiopatologia , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Recidiva , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/fisiopatologia , Fatores de Tempo
15.
Europace ; 20(3): e30-e41, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28402404

RESUMO

Aims: Limited data exist on the long-term outcome of patients (pts) with non-ischemic cardiomyopathy (NICM) and ventricular tachycardia (VT) refractory to conventional therapies undergoing surgical ablation (SA). We aimed to investigate the long-term survival and VT recurrence in NICM pts with VT refractory to radiofrequency catheter ablation (RFCA) who underwent SA. Methods and results: Consecutive pts with NICM and VT refractory to RFCA who underwent SA were included. VT substrate was characterized in the electrophysiology lab and targeted by RFCA. During SA, previous RFCA lesions/scars were identified and targeted with cryoablation (CA; 3 min/lesion; target -150 °C). Follow-up comprised office visits, ICD interrogations and the social security death index. Twenty consecutive patients with NICM who underwent SA (age 53 ± 16 years, 18 males, LVEF 41 ± 20%; dilated CM = 9, arrhythmogenic right ventricular CM = 3, hypertrophic CM = 2, valvular CM = 4, and mixed CM = 2) were studied. Percutaneous mapping/ablation in the electrophysiology lab was performed in 18 and 2 pts had primary SA. During surgery, 4.9 ± 4.0 CA lesions/pt were delivered to the endocardium (2) and epicardium (11) or both (7). VT-free survival was 72.5% at 1 year and over 43 ± 31 months (mos) (range 1-83mos), there was only one arrhythmia-related death. There was a significant reduction in ICD shocks in the 3-mos preceding SA vs. the entire follow-up period (6.6 ± 4.9 vs. 2.3 ± 4.3 shocks/pt, P = 0.001). Conclusion: In select pts with NICM and VT refractory to RFCA, SA guided by pre-operative electrophysiological mapping and ablation may be a therapeutic option.


Assuntos
Cardiomiopatias/complicações , Criocirurgia , Taquicardia Ventricular/cirurgia , Potenciais de Ação , Adulto , Idoso , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Angiografia Coronária , Criocirurgia/efeitos adversos , Criocirurgia/mortalidade , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
17.
J Cardiovasc Electrophysiol ; 28(3): 280-288, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27997060

RESUMO

INTRODUCTION: Bipolar voltage criteria to delineate left atrial (LA) scar have been derived using point-by-point (PBP) contact electroanatomical mapping. It remains unclear how PBP-derived LA scar correlates with multielectrode fast automated mapping (ME-FAM) derived scar. We aimed to correlate scar and bipolar voltages from LA maps created using PBP versus ME-FAM. METHODS AND RESULTS: In consecutive patients undergoing repeat AF ablation, 2 separate LA maps were created using PBP and ME-FAM during sinus rhythm before ablation. Contiguous areas in the LA with a bipolar voltage cutoff of ≤0.2 mV represented dense scar; LA scar percentage was calculated for each map. Each LA shell was divided into 9 regions and each region further subdivided into 4 quadrants for additional analysis; mean voltages of all points obtained using PBP versus ME-FAM in each region were compared. Forty maps (20 PBP: mean 228.5 ± 95.6 points; 20 ME-FAM: 923.0 ± 382.6 points) were created in 20 patients. Mapping time with ME-FAM was shorter compared with PBP (13.3 ± 5.3 vs. 34.4 ± 13.1 minutes; P < 0.001). Mean LA scar percentage was higher with PBP compared with ME-FAM (15.5 ± 17.1% vs. 12.8 ± 17.6%; P = 0.04). Mean PBP voltage distribution was lower (compared with ME-FAM) in the septum (0.95 ± 0.73 vs. 1.46 ± 0.99 mV; P = 0.009), posterior wall (0.84 ± 0.42 vs. 1.40 ± 0.83 mV; P = 0.0008), roof (0.78 ± 0.80 vs. 1.39 ± 1.09 mV; P = 0.0003), and right PV-LA junction (0.34 ± 0.25 vs. 0.59 ± 0.50 mV; P = 0.01) regions, while voltages were similar in all other LA regions (all P > 0.05). CONCLUSIONS: In AF patients undergoing repeat ablation, bipolar voltage is greater in certain LA segments with ME-FAM compared with PBP mapping.


Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Cicatriz/diagnóstico , Cicatriz/cirurgia , Técnicas Eletrofisiológicas Cardíacas/métodos , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Automação , Ablação por Cateter/efeitos adversos , Cicatriz/etiologia , Cicatriz/fisiopatologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação
18.
J Cardiovasc Electrophysiol ; 28(11): 1295-1302, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28800178

RESUMO

INTRODUCTION: There is a paucity of data in favor of mechanical support during catheter ablation of ventricular tachycardia (VT). This study investigated the outcomes of VT ablation associated with mechanical support using percutaneous ventricular assist device (PVAD) versus intra-aortic balloon pump (IABP). METHODS AND RESULTS: We retrospectively examined the outcomes of patients who underwent VT ablation associated with PVAD versus IABP from 2010 to 2013, captured by the Medicare Inpatient Standard Analytic File database. Data from 345 patients (PVAD = 230, IABP = 115) were examined. On admission, the incidence of heart failure was higher in PVAD (84.3% vs. 73.0%; P = 0.01) with similar rates of renal failure in PVAD versus IABP (33.0% vs. 37.4%; P = 0.42). However, PVAD was associated with reduced in-hospital cardiogenic shock (9.1% vs. 23.5%; P  <  0.001), renal failure (11.7% vs. 21.7%; P = 0.01), and length of stay (8.4 ± 7.9 vs. 10.6 ± 7.5; P < 0.001), but with greater hospital discharges to home/self-care (66.0% vs. 51.6%; P = 0.02). Index mortality (6.5% vs. 19.1%; P = 0.001) and mortality in patients with cardiogenic shock (18.2% vs. 41.2%; P = 0.03) were significantly lower with PVAD versus IABP. Furthermore, PVAD was associated with lower all-cause (27.0% vs. 38.7%; P = 0.04) and heart failure-related (21.4% vs. 33.3%; P = 0.03) 30-day hospital readmissions, but with similar redo-VT ablation rates at 1 year (10.2% vs. 14.0%; P = 0.34). CONCLUSION: Among the cases captured by the Medicare database, catheter ablation of VT associated with mechanical support using PVAD was associated with reduced in-hospital cardiogenic shock, renal failure, length of stay, hospital readmissions and mortality, but no difference in redo-VT ablation at 1 year.


Assuntos
Ablação por Cateter/tendências , Bases de Dados Factuais/tendências , Coração Auxiliar/tendências , Medicare/tendências , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Hemodinâmica/fisiologia , Humanos , Estudos Longitudinais , Masculino , Alta do Paciente/tendências , Estudos Retrospectivos , Taquicardia Ventricular/fisiopatologia , Estados Unidos/epidemiologia
19.
J Cardiovasc Electrophysiol ; 28(5): 504-514, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28233951

RESUMO

INTRODUCTION: In outflow tract ventricular arrhythmias (OT-VAs), an abrupt loss of the R wave in lead V2 compared to V1 and V3 (pattern break in V2-PBV2) suggests an origin close to the anterior interventricular sulcus (anatomically opposite to lead V2) and adjacent to proximal coronaries. We studied the outcome of catheter ablation of OT-VAs with a PBV2. METHODS AND RESULTS: Of 130 consecutive patients with idiopathic left bundle block morphology OT-VAs and transition ≤V4, 12 (9%) had PBV2. Outcomes in this group were compared to the remaining 118 patients. Patients with PBV2 were more likely to be younger (41 ± 18 vs. 50 ± 14 years, P = 0.0384) and women (11 [92%] vs. 70 [59%], P = 0.0302). The earliest activation was at the RVOT in seven, left coronary cusp (LCC) in one, anterior interventricular vein (AIV) in two and the epicardium in two. In five (42%) cases (earliest activation in the AIV in two, epicardium in two, and RVOT below the valve level in one), ablation was aborted due to proximity to the left anterior descending (LAD) coronary artery. After 36 ± 17 months and 1.3 ± 0.5 procedures, VAs elimination was achieved in 58% of patients with PBV2 compared to 89% of the reference population (P = 0.0125) with effective site in five of seven at the most anterior and leftward RVOT adjacent to the pulmonic valve (PV). CONCLUSIONS: OT-VAs with PBV2 demonstrate a unique ECG pattern and challenging catheter ablation. Proximity to LAD precludes ablation in about half. Long-term VA suppression could be achieved in only 58% of cases most commonly when the earliest site is at the anterior and leftward RVOT just under the PV.


Assuntos
Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/cirurgia , Ablação por Cateter , Eletrocardiografia , Ventrículos do Coração/cirurgia , Potenciais de Ação , Adulto , Bloqueio de Ramo/fisiopatologia , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
20.
J Cardiovasc Electrophysiol ; 25(3): 293-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24237590

RESUMO

INTRODUCTION: Following myocardial infarction (MI), left ventricular function is determined by cardiac remodeling occurring in both infarcted and noninfarcted myocardium (NIM). Unipolar voltage mapping may detect remodeling changes in NIM that are associated with the left ventricular ejection fraction (LVEF). We aimed to identify (1) unipolar voltage characteristics in patients with chronic MI, and (2) association of voltage abnormalities with degree of left ventricular dysfunction (LVD). METHODS AND RESULTS: Two groups of patients with ischemic cardiomyopathy (ICM) who underwent LV endocardial mapping during catheter ablation for ventricular tachycardia (VT) between January 2010 and December 2012 were studied. The first group (19 males) had mild to moderate LVD (M-LVD, LVEF >35%) and was matched for age, sex, infarction size, and infarction location with 10 males who had severe LVD (S-LVD, LVEF <35%). Both bipolar and unipolar endocardial abnormal voltage areas were measured and compared between groups. Abnormal bipolar area was comparable in both groups (30 ± 8% in the S-LVD group vs 28 ± 8% in the M-LVD group; P = 0.5). Total abnormal unipolar voltage area was significantly larger in the S-LVD group (57 ± 14% vs 43 ± 13%; P = 0.02). The abnormal unipolar voltage area within the normal bipolar voltage area was greater in the S-LVD group (26 ± 11% vs 15 ± 16%; P = 0.03). In receiver operating characteristic curve analysis, an 18.0% cut-off value for abnormal unipolar area within NIM identified severe LVD, with 90% sensitivity and 79% specificity (area under the curve 0.821). CONCLUSIONS: Patients with ICM and severe LVD have larger areas of unipolar voltage abnormality in the noninfarcted tissue than patients with M-LVD.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Cardiomiopatias/fisiopatologia , Isquemia Miocárdica/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Idoso , Cardiomiopatias/diagnóstico , Cardiomiopatias/cirurgia , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/cirurgia , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA