Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Dis Esophagus ; 28(4): 305-11, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-24612509

RESUMO

Antireflux surgery with a magnetic sphincter augmentation device (MSAD) restores the competency of the lower esophageal sphincter with a device rather than a tissue fundoplication. As a regulated device, safety information from the published clinical literature can be supplemented by tracking under the Safe Medical Devices Act. The aim of this study was to examine the safety profile of the MSAD in the first 1000 implanted patients. We compiled safety data from all available sources as of July 1, 2013. The analysis included intra/perioperative complications, hospital readmissions, procedure-related interventions, reoperations, and device malfunctions leading to injury or inability to complete the procedure. Over 1000 patients worldwide have been implanted with the MSAD at 82 institutions with median implant duration of 274 days. Event rates were 0.1% intra/perioperative complications, 1.3% hospital readmissions, 5.6% endoscopic dilations, and 3.4% reoperations. All reoperations were performed non-emergently for device removal, with no complications or conversion to laparotomy. The primary reason for device removal was dysphagia. No device migrations or malfunctions were reported. Erosion of the device occurred in one patient (0.1%). The safety analysis of the first 1000 patients treated with MSAD for gastroesophageal reflux disease confirms the safety of this device and the implantation technique. The overall event rates were low based on data from 82 institutions. The MSAD is a safe therapeutic option for patients with chronic, uncomplicated gastroesophageal reflux disease.


Assuntos
Esfíncter Esofágico Inferior/cirurgia , Refluxo Gastroesofágico/cirurgia , Magnetoterapia/instrumentação , Próteses e Implantes/estatística & dados numéricos , Transtornos de Deglutição/epidemiologia , Transtornos de Deglutição/etiologia , Remoção de Dispositivo/estatística & dados numéricos , Análise de Falha de Equipamento , Segurança de Equipamentos , Humanos , Readmissão do Paciente/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Próteses e Implantes/efeitos adversos , Reoperação/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA