Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
World J Urol ; 42(1): 163, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38488927

RESUMO

INTRODUCTION: Due to the radiation exposure for the urology staff during endourology, our aim was to evaluate the trends of radiation protection in the operation room by endourologists from European centers and to estimate their annual radiation. METHODS: We conducted a multicenter study involving experienced endourologists from different European centers to evaluate whether the protection and threshold doses recommended by the International Commission on Radiation Protection (ICRP) were being followed. A 36-question survey was completed on the use of fluoroscopy and radiation protection. Annual prospective data from chest, extremities, and eye dosimeters were collected during a 4-year period (2017-2020). RESULTS: Ten endourologists participated. Most surgeons use lead aprons and thyroid shield (9/10 and 10/10), while leaded gloves and caps are rarely used (2/10 both). Six out of ten surgeons wear leaded glasses. There is widespread use of personal chest dosimeters under the apron (9/10), and only 5/10 use a wrist or ring dosimeter and 4 use an eye dosimeter. Two endourologists use the ALARA protocol. The use of ultrasound and fluoroscopy during PCNL puncture was reported by 8 surgeons. The mean number of PCNL and URS per year was 30.9 (SD 19.9) and 147 (SD 151.9). The mean chest radiation was 1.35 mSv per year and 0.007 mSv per procedure. Mean radiation exposure per year in the eyes and extremities was 1.63 and 11.5 mSv. CONCLUSIONS: Endourologists did not exceed the threshold doses for radiation exposure to the chest, extremities and lens. Furthermore, the ALARA protocol manages to reduce radiation exposure.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Humanos , Estudos Prospectivos , Exposição Ocupacional/prevenção & controle , Fluoroscopia/efeitos adversos , Exposição à Radiação/prevenção & controle , Doses de Radiação
2.
World J Urol ; 42(1): 240, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630158

RESUMO

PURPOSE: To evaluate the impact of ureteroscope position within renal cavities as well as different locations of the tip of the ureteral access sheath (UAS) on fluid dynamics during retrograde intrarenal surgery (RIRS). MATERIALS AND METHODS: A prospective observational clinical study was performed. Measurements with a flexible ureteroscope placed in the upper, middle and lower calyces were obtained with the tip of the UAS placed either 2 cm below the pyelo-ureteric junction (PUJ), or at the level of the iliac crest. RESULTS: 74 patients were included. The outflow rates from the middle and upper calyxes were statistically significantly higher compared to the lower calyx, both with the UAS close to the pyelo-ureteric junction and at the iliac crest. When the UAS was withdrawn and positioned at the level of the iliac crest, a significant decrease in outflow rates from the upper (40.1 ± 4.3 ml/min vs 35.8 ± 4.1 ml/min) and middle calyces (40.6 ± 4.0 ml/min vs 36.8 ± 4.6 ml/min) and an increase in the outflow from the lower calyx (28.5 ± 3.3 ml/min vs 33.7 ± 5.7 ml/min) were noted. CONCLUSIONS: Our study showed that higher fluid outflow rates are observed from upper and middle calyces compared to lower calyx. This was true when the UAS was positioned 2 cm below the PUJ and at the iliac crest. Significant worsening of fluid dynamics from upper and middle calyces was observed when the UAS was placed distally at the level of the iliac crest. While the difference was statistically significant, the absolute change was not significant. In contrast, for lower calyces, a statistically significant improvement was documented.


Assuntos
Ureter , Ureteroscópios , Humanos , Hidrodinâmica , Rim , Endoscopia , Ureter/cirurgia
3.
BJU Int ; 131(4): 494-502, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36208033

RESUMO

OBJECTIVE: To develop a standardised tool to evaluate flexible ureterorenoscopes (fURS). MATERIALS AND METHODS: A three-stage consensus building approach based on the modified Delphi technique was performed under guidance of a steering group. First, scope- and user-related parameters used to evaluate fURS were identified through a systematic scoping review. Then, the main categories and subcategories were defined, and the expert panel was selected. Finally, a two-step modified Delphi consensus project was conducted to firstly obtain consensus on the relevance and exact definition of each (sub)category necessary to evaluate fURS, and secondly on the evaluation method (setting, used tools and unit of outcome) of those (sub)categories. Consensus was reached at a predefined threshold of 80% high agreement. RESULTS: The panel consisted of 30 experts in the field of endourology. The first step of the modified Delphi consensus project consisted of two questionnaires with a response rate of 97% (n = 29) for both. Consensus was reached for the relevance and definition of six main categories and 12 subcategories. The second step consisted of three questionnaires (response rate of 90%, 97% and 100%, respectively). Consensus was reached on the method of measurement for all (sub)categories. CONCLUSION: This modified Delphi consensus project reached consensus on a standardised grading tool for the evaluation of fURS - The Uniform grading tooL for flexIble ureterorenoscoPes (TULIP) tool. This is a first step in creating uniformity in this field of research to facilitate future comparison of outcomes of the functionality and handling of fURS.


Assuntos
Tulipa , Humanos , Consenso , Técnica Delphi , Rim , Inquéritos e Questionários
4.
World J Urol ; 40(8): 2091-2098, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35776174

RESUMO

PURPOSE: To evaluate the current practice of percutaneous nephrolithotomy (PCNL), conducting a worldwide survey among urologists with a special interest in endo-urology. METHODS: A 22-question survey was specifically developed by the European Association of Urology (EAU) young academic urologists (YAU) and uro-technology (ESUT) groups and globally distributed via SurveyMonkey to almost 2000 members of Endourology Society. The questionnaire included questions dedicated to the demographics and general practice of the participating urologists. RESULTS: In total, 441 responses (male/female ratio - 418/23) were received. A comparatively higher percentage of specialists (56.2%) practiced in academic institutions and had specific endo-urological fellowship training (56.7%). The classical prone PCNL remained the most practiced approach among the surveyed specialists, 47.7% stated to always do prone PCNLs, while 51.8% of respondents used multiple positioning options as required. The PCNL tract was mostly performed by urologists (84.3%) and fluoroscopic guidance was still predominantly used by 74.5% of respondents. The most practiced tract dilation method was balloon dilator used by 42% of respondents. Most of the surveyed urologists had ultrasonic, pneumatic or laser lithotripsy devices in their armamentarium. The use of some form of post-procedural drainage was reported in 85.1% of respondents, whereas tubeless PCNL remained a fairly uncommon practice. CONCLUSION: The majority of urologists still use prone positioning, get their own access under fluoroscopy guidance and use a balloon for tract dilation. However, we also identified that when necessary, urologists will deviate from routine practice and change strategy, adopting other approaches for PCNL.


Assuntos
Cálculos Renais , Nefrolitotomia Percutânea , Nefrostomia Percutânea , Urologia , Feminino , Humanos , Masculino , Nefrostomia Percutânea/métodos , Padrões de Prática Médica , Urologistas , Urologia/educação
5.
BMC Surg ; 21(1): 265, 2021 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-34044862

RESUMO

BACKGROUND: Entero-colovesical fistula is a rare complication of various benign and malignant diseases. The diagnosis is prominently based on clinical symptoms; imaging studies are necessary not only to confirm the presence of the fistula, but more importantly to demonstrate the extent and the nature of the fistula. There is still a lack of consensus regarding the if, when and how to repair the fistula. The aim of the study is to review the different surgical treatment options, focus on surgical indications, and explore cumulative recurrence, morbidity, and mortality rates of entero-vesical and colo-vesical fistula patients. METHODS: A systematic review of the literature was conducted according to PRISMA guidelines. Random effects meta-analyses of proportions were developed to assess primary and secondary endpoints. I2 statistic and Cochran's Q test were computed to assess inter-studies' heterogeneity. RESULTS: Twenty-two studies were included in the analysis with a total of 861 patients. Meta-analyses of proportions pointed out 5, 22.2, and 4.9% rates for recurrence, complications, and mortality respectively. A single-stage procedure was performed in 75.5% of the cases, whereas a multi-stage operation in 15.5% of patients. Palliative surgery was performed in 6.2% of the cases. In 2.3% of the cases, the surgical procedure was not specified. Simple and advanced repair of the bladder was performed in 84.3% and 15.6% of the cases respectively. CONCLUSIONS: Although burdened by a non-negligible rate of complications, surgical repair of entero-colovesical fistula leads to excellent results in terms of primary healing. Our review offers opportunities for significant further research in this field. Level of Evidence Level III according to ELIS (SR/MA with up to two negative criteria).


Assuntos
Fístula Intestinal , Fístula da Bexiga Urinária , Colo , Humanos , Fístula Intestinal/epidemiologia , Fístula Intestinal/etiologia , Fístula Intestinal/cirurgia , Prevalência , Fístula da Bexiga Urinária/epidemiologia , Fístula da Bexiga Urinária/etiologia , Fístula da Bexiga Urinária/cirurgia
6.
BJU Int ; 124(2): 349-356, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30993851

RESUMO

OBJECTIVE: To describe the prevalence and predictors of burnout in USA and European urology residents, as although the rate of burnout in urologists is high and associated with severe negative sequelae, the extent and predictors of burnout in urology trainees remains poorly understood. SUBJECTS AND METHODS: An anonymous 32-question survey of urology trainees across the USA and four European countries, analysing personal, programme, and institutional factors, was conducted. Burnout was assessed using the validated abridged Maslach Burnout Inventory. Univariate analysis and multivariable logistic regression models assessed drivers of burnout in the two cohorts. RESULTS: Overall, 40% of participants met the criteria for burnout as follows: Portugal (68%), Italy (49%), USA (38%), Belgium (36%), and France (26%). Response rates were: USA, 20.9%; Italy, 45.2%; Portugal, 30.5%; France, 12.5%; and Belgium, 9.4%. Burnout was not associated with gender or level of training. In both cohorts, work-life balance (WLB) dissatisfaction was associated with increased burnout (odds ratio [OR] 4.5, P < 0.001), whilst non-medical reading (OR 0.6, P = 0.001) and structured mentorship (OR 0.4, P = 0.002) were associated with decreased burnout risk. Lack of access to mental health services was associated with burnout in the USA only (OR 3.5, P = 0.006), whilst more weekends on-call was associated with burnout in Europe only (OR 8.3, P = 0.033). In both cohorts, burned out residents were more likely to not choose a career in urology again (USA 54% vs 19%, P < 0.001; Europe 43% vs 25%, P = 0.047). CONCLUSION: In this study of USA and European urology residents, we found high rates of burnout on both continents. Despite regional differences in the predictors of burnout, awareness of the unique institutional drivers may help inform directions of future interventions.


Assuntos
Esgotamento Profissional/epidemiologia , Internato e Residência/organização & administração , Urologia/educação , Europa (Continente) , Feminino , Humanos , Masculino , Prevalência , Fatores de Risco , Estados Unidos , Carga de Trabalho
7.
J Urol ; 198(3): 702-706, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28442384

RESUMO

PURPOSE: The purpose of this study was to evaluate the popcorn technique using a wide range of holmium laser settings and fiber sizes in a systematic in vitro assessment. MATERIALS AND METHODS: Evaluations were done with 4 artificial stones in a collection tube. A fixed ureteroscope was inserted through a ureteral access sheath to provide constant irrigation flow and the laser was placed 1 mm from the bottom. Combinations of 0.5 to 1.5 J, 10 to 20 and 40 Hz, and long and short pulses were tested for 2 and 4 minutes. We used 273 and 365 µm laser fibers. All tests were repeated 3 times. The stones were weighed before and after the experiments to evaluate the setting efficiency. Significant predictors of a highly efficient technique were assessed. RESULTS: A total of 144 tests were performed. Mean starting weight of the stones was 0.23 gm, which was consistent among the groups. After the experiment the median weight difference was 0.07 gm (range 0.01 to 0.24). When designating a 50% reduction in stone volume as the threshold indicating high efficiency, the significant predictors of an efficient popcorn technique were a long pulse (OR 2.7, 95% CI 1.05-7.15), a longer duration (OR 11.4, 95% CI 3.88-33.29), a small (273 µm) laser fiber (OR 0.23, 95% CI 0.08-0.70) and higher power (W) (OR 1.14, 95% CI 1.09-1.20). CONCLUSIONS: Higher energy, a longer pulse, frequencies higher than 10 Hz, a longer duration and a smaller laser fiber predict a popcorn technique that is more efficient at reducing stone volume.


Assuntos
Cálculos Renais/terapia , Lasers de Estado Sólido , Litotripsia a Laser/métodos , Humanos , Técnicas In Vitro , Modelos Biológicos
8.
World J Urol ; 35(2): 313-318, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27300338

RESUMO

PURPOSE: To examine laser fiber passage capabilities through flexible ureterorenoscopes (fURSs) and to measure deflections and flow characteristics. METHODS: For this in vitro study, eight fURSs were examined (Olympus® URF-P6, URF-P6, URF-V, URF-V2; Storz® Xc and Flex-X2; Richard Wolf® Cobra Vision; and Lithovue). Four laser fibers standard 200- and 273-µm (uncleaved and cleaved), sheath-coated and ball-tip fibers were attempted to pass through each fURS while deflected at 120°, 180°, maximum deflection, and maximum deflection with reduced 9-mm radius. Measurements included maximal (up/down) deflections and irrigation flow rates achieved with each fiber. RESULTS: Wolf Cobra Vision demonstrated minimal loss of deflections with mean differences of -2°/0° (p > 0.05) when loaded with the 200-µm fiber. The 273-µm fiber provoked utmost deflections that decline when loaded in Olympus URF-P5: mean differences of -52°/-35° (p < 0.001 for upward deflection). Of overall deflections, sheath-coated fiber induced least insult (p > 0.05), while standard 273-µm fiber incited maximum degradation (p < 0.00001). With few exceptions, sheath-coated and ball-tip fibers passed through all maximally deflected scopes. Uncleaved 200- and 273-µm fibers failed to pass through most maximally deflected fURS. However, cleaving their ends allowed 200- and 273-µm fiber to pass through all angles of deflections expect in the Olympus URF-P5 and Olympus URF-P5 and URF-V, respectively. The irrigation through all fURSs was significantly impaired (p < 0.00001). CONCLUSIONS: fURS deflection was least affected by sheath-coated fibers and most affected by the 273-µm fiber. Uncleaved 200- and 273-µm fibers showed least passage capabilities; while removing the ends, the fibers greatly facilitated their passage capabilities as much as the other fibers tested.


Assuntos
Lasers , Ureteroscópios , Desenho de Equipamento
9.
Int Braz J Urol ; 43(3): 476-480, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28338307

RESUMO

INTRODUCTION: The Spies™ system (Karl-Storz®) was introduced into digital ureteroscopy to improve endoscopic vision. To date, there is no data to either indicate which of the Spies modalities is better for improving diagnosis and treatment procedures, nor to compare the modalities in terms of image quality. The aim of this study was to evaluate and compare the image quality of five Spies™ modalities (SM) to the standard white light in an in-vitro model. MATERIALS AND METHODS: Two standardized grids and 3 stones of different composition were recorded in white light and the 5SM (Clara, Chroma, Clara+Chroma), Spectra A and B) using 4 standardized aqueous scenarios. Twelve templates were done in order to simultaneously compare the same objective in the different modalities. Six urologists, five medical students, five urology residents, and five persons not involved with urology evaluated each video on a scale of 1 (very bad) to 5 (very good). RESULTS: Comparing white light to SM, subjects scored better the quality of Clara and Clara+Chroma than white light (p=0.0139 and p<0.05) and scored worse Spectra A and B (p=0.0005 and p=0.0023). When comparing Clara to the other SM, it was ranked equivalent to Clara+Chroma (p=0.67) and obtained a higher rank than Chroma, Spectra A and B (p<0.05, p=0.0001 and p=0.0001). In the multivariate analysis mean scores were higher among urologists. CONCLUSION: In all analyzed scenarios, the subjects ranked Clara and Clara+Chroma as the modalities with better image quality compared to white light.


Assuntos
Neoplasias/diagnóstico por imagem , Ureteroscopia/instrumentação , Doenças Urológicas/diagnóstico por imagem , Adulto , Feminino , Humanos , Litotripsia a Laser , Masculino , Pessoa de Meia-Idade , Ureteroscópios , Ureteroscopia/métodos , Adulto Jovem
10.
Arch Ital Urol Androl ; 89(2): 97-101, 2017 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-28679177

RESUMO

OBJECTIVES: Analyze the oncologic and functional outcomes in patients affected by low risk prostate cancer underwent prostate cryotherapy. Materiasl and methods: It's a prospective tricentric study of 434 patients treated with prostate cryoablation for low risk prostate cancer. By low risk we refer to the D'Amico's risk classification. Two cycles of freezing/thawing are run for each patient following the technique described by Onik. RESULTS: For the 434 patients, the median age was 66 years with a standard deviation of ± 6.68, the average PSA was 6.17 ng/d/L, the median 5.55 with a standard deviation of ± 2.13, the mean prostate volume was 35.59 cc, the median 34.00 cc, with a standard deviation of ± 7.89. Biochemical failure occurred in 67 patients (15.4%). Pre-operative erectile function in men was distributed as follows: severe in 95 patients (19.2%), moderate in 95 (19.2%), medium-moderate in 180 (36.4%), mild in 92 (18.6%), with no dysfunction in 32 (6.5%) patients. Post-operative erectile function, measured 1 month after cryotherapy, was distributed as follows: severe in 321 (65%) patients, moderate in 69 (14%), medium-moderate in 79 (16%), mild in 23 (4.7%), and no dysfunction in only 2 patients (0.4%). Post-operative erectile function after 3 months was distributed as follows: severe in 233 (47.2%) patients, moderate in 66 (13.4%), medium-moderate in 122 (24.7%), mild in 65 (13.2%), and no dysfunction in 8 patients (1.6%). Urinary incontinence was present in 21 patients (4.8%) after 3 months while it dropped to 13 patients (2.9%) after 6 months. CONCLUSIONS: Cryotherapy in the treatment of prostate cancer remains a viable alternative. The availability of new cryoprobes and the use of new diagnostic means such as fusion magnetic resonance will make this more precise and more effective method.


Assuntos
Crioterapia , Neoplasias da Próstata/terapia , Idoso , Disfunção Erétil/etiologia , Humanos , Masculino , Ereção Peniana , Estudos Prospectivos , Neoplasias da Próstata/complicações , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Tempo , Resultado do Tratamento
11.
Arch Ital Urol Androl ; 89(4): 287-292, 2017 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-29473378

RESUMO

OBJECTIVE: Clinical presentation of ureteral stones during pregnancy is generally with renal colic pain. The aim of this study is to present our experience in the management of renal colic during pregnancy in emergency settings. MATERIALS AND METHODS: 208 pregnant patients who presented to emergency department with renal colic pain and underwent ureteroscopy (URS) due to failed conservative therapy were enrolled in the study. Urinary tract stones were diagnosed either with ultrasound (US) examination or during URS. Laser lithotripsy and double J (DJ) stent placement were routinely done in all patients with ureteral stones. The incidence of infective complications and premature uterine contractions (PUC) due to URS were compared. RESULTS: No stone was identified in 36.1% (n = 75) of patients with using US and diagnostic URS. Of the remaining 133 patients, 30 (22.6%) had no stone at US but stones were diagnosed during diagnostic URS. The type of anesthesia had no significant effect on PUC. An increased risk of sepsis and PUC was found in patients with fever at the initial presentation. Interestingly, PUC was more frequent in patients with lower serum magnesium levels. There was a significant correlation with time delay until the intervention and the risk of urosepsis and PUC, individually. CONCLUSIONS: Ureteroscopy is a safe option for evaluation of pregnant patients with unresolved renal colic. According to the current findings, timing of the operation is the most important factor affecting the septic risks and abortion threat. Surgical intervention with URS must be planned as soon as possible.


Assuntos
Trabalho de Parto Prematuro/epidemiologia , Cólica Renal/terapia , Cálculos Ureterais/terapia , Ureteroscopia/métodos , Emergências , Feminino , Humanos , Incidência , Litotripsia a Laser/métodos , Gravidez , Complicações na Gravidez/patologia , Complicações na Gravidez/terapia , Estudos Retrospectivos , Stents , Fatores de Tempo , Resultado do Tratamento , Ureteroscopia/efeitos adversos
12.
Minerva Urol Nephrol ; 76(1): 22-30, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37817480

RESUMO

Prostate imaging techniques have progressed across the years allowing for a better detection and characterization of prostate cancer (PCa) lesions. These advancements have led to the possibility to also improve and tailor the treatments on the most aggressive lesion, defined as Index Lesion (IL), to reduce morbidity. The IL is, indeed, considered as the entity which encompass the most aggressive features in prostate cancer disease. Multiparametric magnetic resonance imaging (mpMRI) has emerged as the suggested tool to detect the disease and plan treatments, including those under investigation such as focal therapy (FT). Our review aimed to query the literature on the ability of mpMRI in IL detection and to explore the future perspectives in PCa IL diagnosis. A review of the literature was performed from January 2010 to July 2023. All studies investigating the performance of mpMRI and other main imaging techniques able to detect the IL were assessed and evaluated. mpMRI performs well in the detection of IL with a sensitivity which reaches 71% to 94% among the different studies. However, mpMRI seems to have limited sensitivity in the detection of small tumours (<0.5 mL) and low-grade histology lesions. To overcome these limitations other diagnostic imaging techniques have been proposed. Multiparametric Ultrasound has shown results comparable to mpMRI while detecting 4.3% fewer clinically significant PCa (P=0.042). Positron emission tomography-based modalities using PSMA seems to have higher sensitivity than mpMRI, being able to yield from 13.5% to 18.2% additional cancers. MRI has emerged as the recommended tool since most of the IL can be easily identified, and is the imaging of choice while selecting patients for FT. Other imaging modalities has been proposed to improve PCa lesions detection, but results need to be confirmed by ongoing randomized controlled trial.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Doenças Prostáticas , Neoplasias da Próstata , Masculino , Humanos , Tomografia Computadorizada por Raios X , Imageamento por Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem
13.
Cancers (Basel) ; 16(17)2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39272942

RESUMO

BACKGROUND: PIRADS score 3 represents a challenge in prostate cancer (PCa) detection with MRI. Our study aimed to evaluate the application of a nomogram on a cohort of patients with PIRADS 3. METHODS: We analyzed 286 patients undergoing fusion prostate biopsy from January 2020 to February 2024. Only PIRADS 3 patients were included. Two nomograms, previously developed and based on clinical variables such as age, total PSA (specifically 2-10 ng/mL) and PSA ratio were applied to estimate the probability (Nomograms A and B) for PCa Grade Group (GG) > 3 and GG < 3. RESULTS: Out of the 70 patients available for analysis, 14/70 patients (20%) had PCa, 4/14 were GG 1 (28.6%), 1/14 were GG 2 (7.1%), 5/14 were GG 3 (35.8%), 2/14 were GG 4 (14.3%) and 2/14 were GG 5 (14.3%). The median probability of PCa GG > 3 and GG < 3 was 5% and 33%, respectively. A significant difference (p = 0.033) was found between patients with negative versus positive biopsy for Nomogram B. There was a significant difference (p = 0.029) for Nomogram B comparing patients with GG < 3 and GG > 3. Using a cut-off of 40% for Nomogram B, sensitivity and specificity were 70% and 80%, respectively. CONCLUSIONS: This cohort has a low probability of harboring PCa especially ISUP > 3. Nomogram B has good accuracy for discriminating patients with PCa from those with negative biopsy.

14.
Minerva Urol Nephrol ; 76(2): 230-234, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38742556

RESUMO

BACKGROUND: Recurrent and complex stone disease may be considered a challenging disease. In 2018, the Calculus group of the SIU (Italian Society of Urology) set itself the goal of establishing the minimum requirements for a center that could continuously manage urolithiasis pathology, named a Stone Center. In this study we present the results of a pilot survey carried out in 2019 with the aim of drawing a map of the situation of Italian urological centers dealing with urinary stones. METHODS: A total of 260 national urology departments dealing with urolithiasis surgery were contacted for this study. A survey was issued to each of the centers to determine the number of patients treated for urinary stones and the amount of procedures performed per year: 1) extracorporeal shock wave lithotripsy ESWL; 2) ureterorenoscopy URS; 3) retrograde intrarenal surgery RIRS; 4) percutaneous nephrolithotomy PCNL. RESULTS: Out of 260 centers contacted, 188 fulfilled the survey. Outcomes were quite variable, with approximately 37% of the centers lacking a lithotripter, and 46% of those that did have it performing fewer than 100 treatments per year. In terms of endoscopic procedures, more than 80% of the centers contacted performed URS or RIRS; however, when it came to percutaneous lithotripsy, these numbers dropped significantly; 33% of the centers contacted did not perform PCNL, and of those who did, 18% had less than 5 years of experience as a center. CONCLUSIONS: Our survey shows a very heterogeneous national picture about urolithiasis treatments. Our goal is to create national paradigms to be able to define stone centers where the patient suffering from complex urinary stones can find a network of professionals with an adequate armamentarium suitable for the management of their pathology.


Assuntos
Cálculos Urinários , Humanos , Itália/epidemiologia , Cálculos Urinários/cirurgia , Cálculos Urinários/terapia , Procedimentos Cirúrgicos Urológicos/estatística & dados numéricos , Procedimentos Cirúrgicos Urológicos/métodos , Litotripsia/métodos , Litotripsia/estatística & dados numéricos , Urolitíase/cirurgia , Urolitíase/terapia , Projetos Piloto , Pesquisas sobre Atenção à Saúde , Inquéritos e Questionários , Nefrolitotomia Percutânea/métodos
15.
Cent European J Urol ; 76(1): 49-56, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37064263

RESUMO

Ureteral stents are useful devices in urological surgery. The main objective of a ureteric stent is to allow passage of urine and reduce early or late complications related to obstruction in the urinary tract. Despite their widespread use, there is a general lack of knowledge and awareness in stent composition and indication of application. We represented a synthesis of our extensive research over materials, coatings and shapes available on the market and then analyzed the main characteristics and peculiarities of ureteral stents. We have also focused our attention over the side effects and complication that must be considered when placing a ureteral stent. Encrustation, microbial colonization, stent-related symptoms and patient's history must always be evaluated when there is the need for a ureteral stent. The perfect stent should have many characteristics including easy insertion and removal, easy manipulation, resistance to encrustation and migration, lack of complications, biocompatibility, radio-opacity, biodurability, affordability (cost-effectiveness), tolerability and optimal flow characteristics. Nevertheless, further research and studies need to be done to provide more information about stent composition and efficacy in vivo. In this narrative review, we covered the basic information and main characteristics of ureteral stents, in order to help clinicians choose the appropriate device needed for a given situation.

16.
Arch Esp Urol ; 76(10): 829-832, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38186077

RESUMO

BACKGROUND: Injectable hyaluronic acid (HA) gel has emerged as a widely used soft tissue filler for surgeries. In penile reconstructive surgery, HA gel has been employed for penile or glans augmentation in selected patients diagnosed with micropenis. This augmentation technique involves injecting the gel into submucosal tissue and increasing the size of the penis for approximately 1 year. A few studies have investigated the possible complications correlated with medically assisted penile injections of HA gel. However, no previous reports have shown the complications of self-administered HA injection. This case report aims to present the first documented case of ischaemic priapism as a complication of self-administered HA injection. CASE PRESENTATION: We present the case of a 43-year-old male who self-administered a 20 mL injection of HA into the dorsal side of his penis. The injected material probably reached the corpora cavernosa, leading to priapism within a few hours. However, the patient did not seek medical attention until 72 h later. The first two initial conservative attempts of blood drainage were unsuccessful because the gel had obstructed vein drainage, causing the penis to remain in a state of priapism. The final treatment approach involved shunting, high enoxaparin doses and oral Effortil administration. CONCLUSIONS: While complications from medically assisted HA injections have been documented, this case report sheds light on the complications arising from self-administered penile injections. Priapism is a severe medical condition that requires immediate treatment to avoid potentially serious long-term consequences. Healthcare providers and patients must acknowledge its symptoms and its appropriate course of treatment, especially in the context of penile medical injections.


Assuntos
Procedimentos de Cirurgia Plástica , Priapismo , Masculino , Humanos , Adulto , Priapismo/induzido quimicamente , Priapismo/terapia , Ácido Hialurônico/efeitos adversos , Pênis/cirurgia , Administração Oral
17.
J Clin Med ; 12(24)2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-38137717

RESUMO

The invention of the flexible ureteroscope (fURS) and its subsequent spread have revolutionized the surgical management of urolithiasis and upper tract urothelial carcinoma (UTUC). During the last few years, single-use flexible ureteroscopes (su-fURSs) have been developed to improve the limitations of reusable fURSs, namely their cost, durability and risk of device contamination. Since the introduction of the first fully disposable digital fURS, several su-fURSs have been developed by various manufacturers. In this pictorial review, we combined the different physical and technical features of su-fURSs currently available on the market with Food and Drug Administration (FDA) and European Conformity (CE) approval, in order to help surgeons choose the appropriate device according to each case requirement and personal preferences. To the best of our knowledge, 17 su-fURSs with CE and FDA approval have been developed to date.

18.
Eur Urol Focus ; 2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-37940392

RESUMO

CONTEXT: Laser performance for lithotripsy is currently reported using units of measurement such as J/mm3, mm3/J, mm3/s, s/mm3, and mm3/min. However, there are no current standardized definitions or terminology for these metrics. This may lead to confusion when assessing and comparing different laser systems. OBJECTIVE: The primary objective was to summarize outcome values and corresponding terminology from studies on laser lithotripsy performance using stone volume in relation to time or energy. The secondary objective was to propose a standardized terminology for reporting laser performance metrics. EVIDENCE ACQUISITION: A systematic review of the literature was conducted using the search string ("j*/mm3" OR "mm3/j*" OR "mm3/s*" OR "s*/mm3" OR "mm3/min*" OR "min*/mm3" AND "lithotripsy") on Scopus, Web of Science, Embase, and PubMed databases. Study selection, data extraction, and quality assessment were performed independently by two authors. EVIDENCE SYNTHESIS: A total of 28 studies were included, covering holmium:yttrium-aluminum-garnet (Ho:YAG), MOSES, and thulium fiber laser (TFL) technologies. Laser energy consumption values reported for the studies ranged from 2.0 - 43.5 J/mm3in vitro and from 2.7 - 47.8 J/mm3in vivo, translating to laser ablation efficiency of 0.023 - 0.500 mm3/J and 0.021 - 0.370 mm3/J, respectively. Laser ablation speeds ranged from 0.3 - 8.5 mm3/s in vivo, translating to lasing time consumption of 0.12 - 3.33 s/mm3. Laser efficacy ranged from 4.35 - 51.7 mm3/min in vivo. There was high heterogeneity for the terminology used to describe laser performance for the same metrics. CONCLUSIONS: The range of laser performance metric values relating stone volume to energy or time is wide, with corresponding differing terminology. We propose a standardized terminology for future studies on laser lithotripsy, including laser ablation efficiency (mm3/J), laser ablation speed (mm3/s), and laser energy consumption (J/mm3). Laser efficacy (mm3/min) is proposed as a broader term that is based on the total operative time, encompassing the whole technique using the laser. PATIENT SUMMARY: We reviewed studies to identify the units and terms used for laser performance when treating urinary stones. The review revealed a wide range of differing units, outcomes, and terms. Therefore, we propose a standardized terminology for future studies on laser stone treatment.

19.
J Clin Med ; 12(17)2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37685776

RESUMO

Flexible ureteroscopy (fURS) with laser lithotripsy is currently the gold standard surgical treatment for ureteral and kidney stones with a maximum diameter of 2 cm [...].

20.
Cent European J Urol ; 76(3): 245-250, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38045778

RESUMO

Introduction: The area of paediatric endourology is unique and is recognised to be challenging, and it requires a certain level of focused training and expertise. Our aim was to conduct a worldwide survey in order to gain an overview regarding the current practice patterns for minimally invasive treatments of paediatric upper urinary tract stone patients. Material and methods: The survey was distributed between December 2021 and April 2022 through urology sections and societies in United Kingdom, Latin America and Asia. The survey was made up of 20 questions and it was distributed online using the free online Google Forms (TM). Results: 221 urologists answered the survey with 56 responses each from India, South America and UK and 53 responses from the rest of Europe (15 countries). In total, 163 responders (73.7%) managed paediatric stone patients in their daily practice. Of the responders, 60.2% were adult urologists and 39.8% were paediatric urologists. 12.9% adult urologists and 20.4% paediatric urologists run independent clinics while some run combined adult and paediatric clinics sometimes with the support of the nephrologists. Only 33.9% urologists offered all surgical treatments [extracorporeal shock wave lithotripsy (ESWL), percutaneous nephrolithotomy (PCNL), ureteroscopy (URS) and retrograde intrarenal surgery (RIRS)]. Conclusions: Treatment of paediatric stones can vary according to country and legislations. Based on the results of this survey, minimally invasive methods such as URS and mini PCNL seem to have become more popular. In most institutions a collaboration exists between adult and paediatric urologists, which is the key for a tailored decision making, counselling and treatment success.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA