Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Circ J ; 87(12): 1711-1719, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-37258224

RESUMO

BACKGROUND: Pulmonary vein stenosis (PVS) after PV isolation (PVI) for atrial fibrillation (AF) is a severe complication that requires angioplasty. This study aimed to compare the reduction of the cross-sectional PV area (PVA) and the incidence of PVS after cryoballoon (CB)-PVI, hot balloon (HB)-PVI, or laser balloon (LB)-PVI.Methods and Results: A total of 320 patients who underwent an initial catheter ablation procedure for AF using a CB, HB, or LB in 2 hospitals were included. They underwent contrast-enhanced multidetector CT before and 3 months after the procedure. In all 4 PVs, the reduction in PVA was more significant in the LB group than in the CB or HB groups, respectively. Moderate (50-75%) and severe (>75%) PVS were observed in 5.3% and 0.5% of the PVs, respectively. Although moderate PVS was more frequently observed in the LB group than in the CB or HB groups (8.2%, 3.8%, and 5.0%; P=0.03), the incidence of severe PVS was similar in the LB, CB, and HB groups (0.3%, 0.5%, and 1.0%; P=0.46). Symptomatic PVS requiring intervention occurred in 1 (0.3%) patient. CONCLUSIONS: Although the reduction in cross-sectional PVA and the incidence of moderate PVS after LB-PVI was more significant than after CB-PVI or HB-PVI, it rarely led to severe PVS. Symptomatic PVS requiring intervention was rare after the balloon ablation of AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Estenose de Veia Pulmonar , Humanos , Estenose de Veia Pulmonar/diagnóstico por imagem , Estenose de Veia Pulmonar/etiologia , Estudos Transversais , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Lasers
2.
Heart Vessels ; 38(3): 413-421, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36194289

RESUMO

The "pre-freezing" technique was a method in which a fully inflated balloon after the start of freezing was pressed against the pulmonary vein (PV) during cryoballoon ablation and has been applied especially in large-size PVs. Of 556 patients who underwent cryoballoon ablation for atrial fibrillation (AF), the pre-freezing technique was applied to 48 patients. The resulting 2:1 propensity score-matched data set included 120 patients. Using the pre-freezing technique, all left-superior PVs, all left-inferior PVs, and 95% of right-superior PVs were successfully isolated. In most right-inferior PVs, complete sealing using the pre-freezing technique was challenging, and this technique was not applied. Procedure time was similar between the two groups. In the pre-freezing group, the percentage of the left atrial posterior wall isolated was larger (47.6 ± 10.3 vs. 42.8 ± 15.7%, P = 0.006), and the postoperative reduction of diaphragmatic compound motor action potentials tended to occur less frequently (2.5 vs. 12.5%, P = 0.07), and the reduction of the cross-sectional LSPV area was smaller (17.5 ± 12.2 vs. 27.2 ± 19.8%, P = 0.03) than the conventional group. The AF-free rate of the two groups was similar between the two groups (P = 0.15). The pre-freezing technique was a simple method that can isolate a wider surface area during cryoballoon PV isolation. While the postoperative AF recurrence was comparable, the postoperative reduction in the cross-sectional PV area was less than that of the conventional method, which may reduce the risk of PV stenosis.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Congelamento , Estudos Transversais , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento
3.
J Cardiovasc Electrophysiol ; 33(9): 2100-2103, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35842800

RESUMO

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) in patients with tachycardia-bradycardia syndrome (TBS) can be a major therapeutic option to replace permanent pacemaker implantation (PMI). However, the very long-term outcome of more than 15 years in these patients has not been elucidated. METHODS: From 2002 to 2008, 25 consecutive TBS patients (62 ± 7.9 years old, 68% male) with both AF and symptomatic sinus pauses (>3.0 s) were performed radiofrequency AF ablation. These patients were followed for 15 ± 2.7 years. RESULTS: The median longest sinus pause before the ablation procedure was 6.0 s (4.4-8.0). Following 1.6± 0.8 ablation procedures, 18 (72%) patients remained free from AF. Three (12%) patients died due to noncardiovascular causes, and seven (28%) patients underwent PMI due to symptomatic sinus pause after recurrent AF in five patients and progression of sinus node dysfunction in two patients. The median duration from the first AF ablation to PMI was 6.3 years (range: 9 days to 11.0 years). Five and two patients required PMI more than 5 and 10 years after the first ablation procedure, respectively. CONCLUSION: AF ablation prevented PMI in 72% of TBS patients for a 15-year follow-up. However, in consideration of the long duration of PMI, a continuous careful long-term follow-up was warranted.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Bradicardia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Síndrome do Nó Sinusal/terapia , Taquicardia/diagnóstico , Taquicardia/cirurgia , Resultado do Tratamento
4.
Heart Vessels ; 37(1): 110-114, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34216250

RESUMO

The temporal changes in ambulatory monitoring findings after cryoballoon (CB) ablation of atrial fibrillation (AF) have not been well elucidated. This study aims to compare the details of ambulatory monitoring after CB and radiofrequency catheter (RFC) ablation for AF. Of 724 consecutive AF patients who underwent initial ablation using a CB or RFC, 508 (254 pairs) were selected using propensity score matching. Ambulatory monitoring was performed at 1, 3, 6, 12, 24 and 36 months after the procedure. After 1, 3 and 6 months, the number of total heart beats (THBs) was larger in the CB group than in the RFC group. It gradually decreased and became significantly similar by 12 months after ablation. THBs significantly increased 1, 3, 6 and 12 months after ablation in both the RFC and CB groups and became statistically similar by 24 months after ablation. The atrial premature contraction burden was higher in the RFC group than in the CB group at 3 months after ablation. THB and APC burden after AF ablation were significantly different between the RF and CB groups. THBs returned to statistically similarity by 2 years after ablation in both groups.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Complexos Atriais Prematuros/diagnóstico , Criocirurgia/efeitos adversos , Frequência Cardíaca , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 30(11): 2310-2318, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31452290

RESUMO

BACKGROUND: The presence of heart failure (HF) has been associated with poorer outcomes in patients undergoing catheter ablation (CA) for atrial fibrillation (AF). However, the effectiveness of CA amongst the subset of patients with tachycardia-induced cardiomyopathy (TIC) remains poorly defined. METHODS AND RESULTS: In a retrospective analysis we compared outcomes of first-time CA for persistent AF in a cohort of patients with previously diagnosed TIC (n = 45; age 58 ± 8 years; 91% male) to those with structurally normal hearts (non-TIC; n = 440; age 55 ± 9 years; 95% male). TIC was defined as an impaired ventricular function (left ventricular ejection function [LVEF] <50%), which was reversed after the treatment of HF. We compared atrial arrhythmias (AAs) recurrence after the CA in the TIC and non-TIC cohorts. In the TIC group, LVEF improved from 35.8% ± 8.1% to 57.5% ± 8.3% after treatment of HF. During 3.3 ± 1.5 years follow-up, AAs-free survival after CA was significantly higher in the TIC group as compared with the non-TIC group (69% vs 42%; P = .001), despite a comparable CA strategy between the two groups. In multivariable analysis, absence of HF with TIC, longer AF duration, and complex fractionated atrial electrogram ablation were independent predictors of arrhythmia recurrence (OR, 1.02; 95% CI, 1.01-1.03; P < .01; OR, 0.40; 95% CI, 0.20-0.79; P < .01 and OR, 2.29; 95%CI; 1.27-4.11; P < .01, respectively). In addition, the outcome after the last procedure was superior in the TIC cohort (89% vs 72%; P = .03) with fewer CA procedures as compared with the non-TIC cohort (1.3 ± 0.5 vs 1.5 ± 0.7; P = .01). CONCLUSIONS: Persistent patients with AF with TIC have a more favorable outcome after the CA as compared with those without.


Assuntos
Fibrilação Atrial/cirurgia , Cardiomiopatias/etiologia , Ablação por Cateter , Potenciais de Ação , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Recidiva , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
6.
J Cardiovasc Electrophysiol ; 29(6): 854-860, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29570900

RESUMO

INTRODUCTION: Atrial fibrillation (AF) ablation is increasingly common, but is associated with potential major complications. Technology, experience, and protocols have evolved significantly in recent times, and may have impacted procedural safety. We sought to compare AF ablation safety profiles, including complication rates and fluoroscopy times in a "modern" versus "historical" cohort. METHODS AND RESULTS: We evaluated consecutive patients undergoing AF ablation from a modern cohort (MC) from 2014 to 2015 and a historic cohort (HC) from 2009 to 2011 for complications. Major complications were categorized according to Heart Rhythm Society guidelines. We included 1,425 patients, 726 in the HC and 699 in the MC. The MC was older, had more OSA and less valvular AF. Fifty-two (3.5%) procedures suffered major complications across the cohorts, with significantly fewer in the MC (5.0% vs. 2.3%, P  =  0.007). The largest reductions were seen in vascular, hemorrhagic, ischemic stroke, and perforation/tamponade related complications. Periprocedural antiplatelets drugs (aHR 2.1 [95 CI 1.1-3.9], P  =  0.02) and force-sensing catheters (aHR 0.4 [95 CI 0.2-0.9], P  =  0.03) were independently related to major complication rates. Direct oral anticoagulants and uninterrupted anticoagulation were not associated with complications. There was a decrease in both fluoroscopy (-17.4 minutes [95 CI 19.2-15.6], P < 0.0001) and radiofrequency ablation times (-561 seconds [95CI -750 to -371], P < 0.0001). CONCLUSIONS: The safety profile of AF ablation has improved significantly in less than a decade.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/tendências , Complicações Pós-Operatórias/prevenção & controle , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Radiografia Intervencionista/tendências , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
Europace ; 20(6): 943-948, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29016768

RESUMO

Aims: Establishment of pulmonary vein isolation (PVI) during cryoballoon (CB) ablation is generally confirmed by use of an octapolar inner-lumen mapping catheter (Achieve®). The aim of this study is to evaluate the residual PV potential (PVP) using the conventional circular catheter after CB-PVI. Methods and results: A total of 105 consecutive patients (418 PVs) with paroxysmal AF who underwent the initial CB-PVI were prospectively included in this study. Of those, 305 (73%) PVs with real-time recordings of PVP elimination by Achieve® catheter during successful PVI were included. After isolation of all 4 PVs, PV antral remapping by conventional circular mapping catheter was performed. After CB-PVI, residual PVP was detected in 4.3% (13/305) of PVs (1.2% of left-superior PV, 2.5% of left-inferior PV, none of right-superior PV, and 20% of right-inferior PV). Almost 60% of residual PV potential was located around the bottom portion of the right-inferior PV. In PVs with residual potential, PV trunk was shorter (12.7 ± 5.7 mm vs. 18.7 ± 7.9, P = 0.001), minimal balloon temperature was higher (-46.6 ± 5.9 °C vs. -50.9 ± 8.2, P = 0.02), and balloon warming time was shorter (35.6 ± 17.8 s vs. 50.0 ± 22.8, P = 0.006) than those without. All residual potentials were eliminated by additional touch up ablation. After the initial ablation procedure, 1-year AF-free rate was 79.5%. Conclusion: PV remapping after CB-PVI revealed residual antral PVP in 4.3% of PVs and in 20% of RIPVs in particular. The Achieve® catheter sometimes fails to detect complete PV antral isolation.


Assuntos
Fibrilação Atrial , Cateteres Cardíacos , Criocirurgia , Técnicas Eletrofisiológicas Cardíacas , Cuidados Pós-Operatórios , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/instrumentação , Criocirurgia/métodos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Técnicas Eletrofisiológicas Cardíacas/métodos , Desenho de Equipamento , Feminino , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios/instrumentação , Cuidados Pós-Operatórios/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Reprodutibilidade dos Testes , Resultado do Tratamento
8.
Heart Vessels ; 33(5): 529-536, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29147788

RESUMO

Cryoballoons (CBs) have proven to be effective for achieving pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). Dissociated PV activity (DPVA) after successful radiofrequency PVI is sometimes observed inside the PV and has been found to prove the achievement of electrical disconnection from the left atrium. However, little is known about the incidence or characteristics of DPVA after CB-PVI. The aim of this study was to compare the incidence and characteristics of DPVA in patients undergoing CB and radiofrequency (RF) ablation for AF. Two hundred and ninety-four propensity score-matched patients from 440 consecutive patients who underwent initial catheter ablation for paroxysmal AF were included in the present study (CB-PVI 147, RF-PVI 147). DPVA was more frequently observed after CB-PVI than after RF-PVI (32 vs. 19% of the PVs, P < 0.001), especially in the left superior PV (52 vs. 29%, P < 0.001) and left inferior PV (22 vs. 7%, P < 0.001). The AF-free rate after the initial ablation in the patients with and without DPVA was similar in both the CB (P = 0.23) and RF (P = 0.39) groups. During repeat ablation procedures for recurrent AF, PV reconnection was similarly observed in PVs with and without DPVA during the initial procedure, both in the CB (30 vs. 44%, P = 0.29) and RF (65 vs. 58%, P = 0.41) groups. DPVA was more frequently observed after CB-PVI than after RF-PVI. The presence of DPVA was not related to the ablation outcome or chronic PV reconnection following CB-PVI.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/fisiopatologia , Pontuação de Propensão , Veias Pulmonares/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Sistema de Condução Cardíaco/cirurgia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/cirurgia , Resultado do Tratamento
9.
Heart Vessels ; 33(10): 1238-1244, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29637262

RESUMO

Atrial fibrillation (AF) ablation requires transseptal puncture to access the left atrium. Recently, a radiofrequency (RF) needle was developed. The purpose of this study was to compare the incidence of MRI-confirmed acute cerebral embolism (ACE) during AF ablation procedures performed with RF needle versus mechanical needle transseptal puncture. This study consisted of 383 consecutive patients who underwent catheter ablation for AF that required transseptal puncture with mechanical or radiofrequency transseptal needles. Of those, 232 propensity score-matched patients (116 with each needle type) were included in the analysis. All patients had cerebral MRI performed 1 or 2 days after the procedure. Baseline characteristics were similar between the two groups. Total procedure time was significantly shorter in Group RF than Group non-RF (167 ± 50 vs. 181 ± 52 min, P = 0.01). ACE was detected by MRI in 59 (25%) patients. All patients with ACE were asymptomatic. Incidence of ACE was lower in Group RF than Group non-RF (19 vs. 32%, P = 0.02). B-type natriuretic peptide level was higher in the patients with ACE as compared to those without ACE (65.2 ± 68.7 vs. 44.7 ± 55.1 pg/ml, P = 0.02). In multivariable analysis, the use of RF needle and BNP level was related to the incidence of ACE (OR = 0.499, 95% CI 0.270-0.922, P = 0.03 and OR = 1.005, 95% CI 1.000-1.010, P = 0.03). Use of RF needle for transseptal puncture was associated with lower total procedure time and risk of ACE during catheter ablation of AF.


Assuntos
Fibrilação Atrial/cirurgia , Septo Interatrial/cirurgia , Ablação por Cateter/instrumentação , Complicações Intraoperatórias/epidemiologia , Agulhas , Punções/instrumentação , Tromboembolia/epidemiologia , Fibrilação Atrial/diagnóstico , Septo Interatrial/diagnóstico por imagem , Ecocardiografia Transesofagiana , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Incidência , Complicações Intraoperatórias/prevenção & controle , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Estudos Retrospectivos , Tromboembolia/diagnóstico , Tromboembolia/etiologia , Tomografia Computadorizada por Raios X
10.
Heart Vessels ; 33(7): 770-776, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29357093

RESUMO

Atrial fibrillation (AF), especially asymptomatic cases, is often detected by medical checkups. We investigated the outcome of AF ablation in cases detected by medical checkups. We reviewed the data of 735 patients with AF (56 ± 10 years, paroxysmal: 441 patients) who underwent initial catheter ablation. All patients were divided into two groups based on their AF being diagnosed either by a medical checkup (group M) or not (group NM). AF was diagnosed by medical checkups in 263 (36%) patients. In Group M, the age was younger, time from the diagnosis to ablation shorter, left atrium dimension larger, and left ventricular ejection fraction lower than in Group NM. Male gender, persistent AF, and asymptomatic AF were more frequently seen in Group M than in Group NM. A mean of 13 ± 11 months after the initial ablation procedure, AF recurrence was more frequently observed in group M compared to group NM (P = 0.018). While the AF recurrence rate was similar in both groups in persistent AF patients (P = 0.87), it was more frequently observed in Group M than in Group NM in paroxysmal AF patients (P = 0.005). AF diagnosed by medical checkups was often associated with a worse outcome of catheter ablation, especially in paroxysmal AF patients.


Assuntos
Fibrilação Atrial/diagnóstico , Ablação por Cateter , Taquicardia Paroxística/diagnóstico , Angiografia , Fibrilação Atrial/cirurgia , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Paroxística/cirurgia , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 28(1): 56-67, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27781325

RESUMO

AIMS: Catheter ablation can be lifesaving in ventricular tachycardia (VT) storm, but the underlying substrate in patients with storm is not well characterized. We sought to compare the clinical factors, substrate, and outcomes differences in patients with sustained monomorphic VT who present for catheter ablation with VT storm versus those with a nonstorm presentation. METHODS: Consecutive ischemic (ICM; n = 554) or nonischemic cardiomyopathy patients (NICM; n = 369) with a storm versus nonstorm presentation were studied (ICM storm 186; NICM storm 101). RESULTS: In ICM, storm compared with nonstorm patients had significantly lower left ventricular (LV) ejection fraction (EF), greater number of antiarrhythmic drug (AAD) failures, slower VTs, greater number of scarred LV segments, higher incidence of anterior, septal, and apical endocardial LV scar (all P < 0.05). However, outcomes in follow-up were similar (12-month ventricular arrhythmia [VA]-free survival: 51% vs. 52%, P = 0.6; survival free of death/transplant 75% vs. 87%, P = 0.7). In addition to the above differences, NICM storm patients were also older; however, the extent and distribution of scar was similar except for a higher incidence of lateral endocardial scar in storm patients (P = 0.05). VA-free survival (36% vs. 47%, P = 0.004) and survival free of death/transplant, however, were worse in NICM storm than nonstorm patients (72% vs. 88%, P = 0.001). NICM storm patients had worse VA-free survival than ICM storm patients. CONCLUSION: There are differences in clinical factors and scar patterns in patients undergoing VT ablation who present with VT storm versus those with a nonstorm presentation. Clinical outcomes are worse in NICM storm patients.


Assuntos
Cardiomiopatias/complicações , Ablação por Cateter , Isquemia Miocárdica/complicações , Taquicardia Ventricular/cirurgia , Potenciais de Ação , Adulto , Idoso , Antiarrítmicos/uso terapêutico , Boston , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Ablação por Cateter/efeitos adversos , Cicatriz/etiologia , Cicatriz/fisiopatologia , Progressão da Doença , Intervalo Livre de Doença , Feminino , Frequência Cardíaca , Transplante de Coração , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/mortalidade , Isquemia Miocárdica/fisiopatologia , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
12.
Heart Vessels ; 32(4): 501-505, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28054100

RESUMO

We herein present a case (72 years, male) with total absence of pulmonary veins (PVs) potentials at the beginning of the first procedure for paroxysmal atrial fibrillation (AF), demonstrating dormant conduction between the left atrium and all PVs revealed by adenosine triphosphate provocation with relation to the incidence of AF. He was free from atrial arrhythmias during 1 year follow-up after complete PV isolation with the elimination of multiple transient dormant conductions by circular mapping catheter guide ablation.


Assuntos
Trifosfato de Adenosina/administração & dosagem , Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Idoso , Humanos , Masculino , Veias Pulmonares/fisiopatologia , Resultado do Tratamento
13.
Heart Vessels ; 31(2): 261-4, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25213428

RESUMO

A 57-year-old male with persistent atrial fibrillation (AF) was referred for catheter ablation. Multidetector computed tomography (MDCT) revealed that a membrane divided the left atrium into two chambers, thus indicating the presence of cor triatriatum sinister. A 3D image reconstructed by MDCT showed that the accessory atrium received the left common and the right side PVs, as if it were a total common trunk, and this then flowed into the main atrium. After isolation of the pulmonary vein and posterior wall from the left atrium, AF could not be induced by any programmed pacing. The patient has remained free from AF during the 1 year of follow-up.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Coração Triatriado/complicações , Veias Pulmonares/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Estimulação Cardíaca Artificial , Coração Triatriado/diagnóstico , Técnicas Eletrofisiológicas Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Flebografia , Veias Pulmonares/anormalidades , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Resultado do Tratamento
14.
Heart Vessels ; 31(2): 256-60, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25223535

RESUMO

A 40-year-old female presented at our hospital because of heart palpitations. During an electrophysiological study, atrioventricular (AV) conduction showed dual AV nodal physiology. Three types of supraventricular tachycardia (SVT) were induced. The initiation of SVT was reproducibility dependent on a critical A-H interval prolongation. An early premature atrial contraction during SVT repeatedly advanced the immediate His potential with termination of the tachycardia, indicating AV node reentrant tachycardia (AVNRT). However, after atrial overdrive pacing during SVT without termination of the tachycardia, the first return electrogram resulted in an AHHA response, consistent with junctional tachycardia. The mechanism of paradoxical responses to pacing maneuvers differentiating AVNRT and junctional tachycardia was discussed.


Assuntos
Estimulação Cardíaca Artificial , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia Ectópica de Junção/diagnóstico , Potenciais de Ação , Adulto , Ablação por Cateter , Diagnóstico Diferencial , Eletrocardiografia , Feminino , Sistema de Condução Cardíaco/cirurgia , Frequência Cardíaca , Humanos , Valor Preditivo dos Testes , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Ectópica de Junção/fisiopatologia , Taquicardia Ectópica de Junção/cirurgia , Resultado do Tratamento
15.
Heart Vessels ; 31(8): 1402-4, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26391679

RESUMO

An 85-year-old female presented to our institution with symptomatic sick sinus syndrome. During pacemaker implantation, an anchoring sleeve in the right ventricular lead was embolized in the left pulmonary artery. Although the anchoring sleeve was radiolucent, digital subtraction angiography revealed an angiographic filling defect in the lower branch of the left pulmonary artery, and a snare catheter enabled the anchoring sleeve to be grasped and extracted.


Assuntos
Remoção de Dispositivo/métodos , Marca-Passo Artificial , Artéria Pulmonar/diagnóstico por imagem , Síndrome do Nó Sinusal/terapia , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos
16.
Heart Vessels ; 31(3): 397-401, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25471944

RESUMO

Warfarin is widely used to perform catheter ablation for atrial fibrillation (AF). Heparin is usually administered during this procedure to prevent thromboembolic events, while protamine is used to reduce the incidence of bleeding complications. The purpose of this study was to investigate the influence of heparin and protamine administration on the effects of warfarin and its safety. The subjects included 226 AF patients (206 males, 54.9 ± 9.1 years, paroxysmal/persistent AF: 118/108) undergoing AF ablation with the discontinuation of warfarin administration over 2 days. Heparin was administered to achieve an activated clotting time (ACT) above 300 s during the procedure. Several parameters of the coagulation status, including the prothrombin time international normalized ratio (PT-INR) and ACT values, measured immediately before and after protamine infusion were compared. The mean value of PT-INR prior to ablation was 1.9 ± 0.6. At the end of the procedure, the mean ACT and PT-INR values were 348.0 ± 52.9 and 2.9 ± 0.7, respectively. Following the infusion of 30 mg of protamine, both the ACT and PT-INR values significantly decreased, to 159.6 ± 31.0 (p < 0.0001) and 1.6 ± 0.3 (p < 0.0001), respectively. No cases of symptomatic cerebral infarction were observed, although femoral hematomas developed in 17 (7.5 %) of the patients without further consequence. The concomitant use of heparin augments the effect of warfarin. Meanwhile, protamine administration immediately reverses both the ACT and PT-INR, indicating the applicability of protamine for AF ablation in patients under the mixed administration of heparin and warfarin.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/terapia , Coagulação Sanguínea/efeitos dos fármacos , Ablação por Cateter , Heparina/administração & dosagem , Varfarina/administração & dosagem , Adulto , Idoso , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Testes de Coagulação Sanguínea , Perda Sanguínea Cirúrgica/prevenção & controle , Ablação por Cateter/efeitos adversos , Esquema de Medicação , Monitoramento de Medicamentos/métodos , Feminino , Heparina/efeitos adversos , Antagonistas de Heparina/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Hemorragia Pós-Operatória/induzido quimicamente , Hemorragia Pós-Operatória/prevenção & controle , Valor Preditivo dos Testes , Protaminas/administração & dosagem , Fatores de Risco , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Fatores de Tempo , Resultado do Tratamento , Varfarina/efeitos adversos
17.
Heart Vessels ; 31(12): 2014-2024, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26936451

RESUMO

Filling defects of the left atrial appendage (LAA) on multidetector computed tomography (MDCT) are known to occur, not only due to LAA thrombi formation, but also due to the disturbance of blood flow in the LAA of patients with atrial fibrillation (AF). The purpose of this study was to evaluate the impact of the maintenance of sinus rhythm via ablation on the incidence of LAA filling defects on MDCT in patients with AF. A total of 459 consecutive patients were included in the present study. Prior to ablation, MDCT and transesophageal echocardiography (TEE) were performed. AF ablation was performed in patients without LAA thrombi confirmed on TEE. The LAA filling defects were evaluated on MDCT at 3 months after ablation. LAA filling defects were detected on MDCT in 51 patients (11.1 %), among whom the absence of LAA thrombi was confirmed in 42 patients using TEE. The LAA Doppler velocity in patients with LAA filling defects was lower than that of patients without filling defects (0.61 ± 0.19 vs. 0.47 ± 0.21 m/s; P < 0.0001). The sensitivity, specificity and negative predictive value of MDCT in the detection of thrombi were 100, 91 and 100 %, respectively. No LAA filling defects were observed on MDCT at 3 months after ablation in any of the patients, including the patients in whom filling defects were noted prior to the procedure. MDCT is useful for evaluating the presence of LAA thrombi and the blood flow of the LAA. The catheter ablation of AF not only suppresses AF, but also eliminates LAA filling defect on MDCT suggesting the improvement of LAA blood flow.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Tomografia Computadorizada Multidetectores , Trombose/diagnóstico por imagem , Idoso , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Ablação por Cateter , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Trombose/etiologia , Trombose/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
18.
Europace ; 16(2): 208-13, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23751930

RESUMO

AIMS: Although patients with paroxysmal atrial fibrillation (AF) and prolonged sinus pauses [tachycardia-bradycardia syndrome (TBS)] are generally treated by permanent pacemaker, catheter ablation has been reported to be a curative therapy for TBS without pacemaker implantation. The purpose of this study was to define the potential role of successful ablation in patients with TBS. METHODS AND RESULTS: Of 280 paroxysmal AF patients undergoing ablation, 37 TBS patients with both AF and symptomatic sinus pauses (age: 62 ± 8 years; mean maximum pauses: 6 ± 2 s) were analysed. During the 5.8 ± 1.2 years (range: 5-8.7 years) follow-up, both tachyarrhythmia and bradycardia were eliminated by a single procedure in 19 of 37 (51%) patients. Repeat procedures were performed in 14 of 18 patients with tachyarrhythmia recurrence (second: 12 and third: 2 patients). During the repeat procedure, 79% (45 of 57) of previously isolated pulmonary veins (PVs) were reconnected to the left atrium. Pulmonary vein tachycardia initiating the AF was found in 46% (17 of 37) and 43% (6 of 14) of patients during the initial and second procedure, respectively. Finally, 32 (86%) patients remained free from AF after the last procedure. Three patients (8%) required pacemaker implantation, one for the gradual progression of sinus dysfunction during a period of 6.5 years and the others for recurrence of TBS 3.5 and 5.5 years after ablation, respectively. CONCLUSION: Catheter ablation can eliminate both AF and prolonged sinus pauses in the majority of TBS patients. Nevertheless, such patients should be continuously followed-up, because gradual progression of sinus node dysfunction can occur after a long period of time.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Sistema de Condução Cardíaco/cirurgia , Frequência Cardíaca , Parada Sinusal Cardíaca/cirurgia , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Estimulação Cardíaca Artificial , Ablação por Cateter/efeitos adversos , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Reoperação , Síndrome do Nó Sinusal/etiologia , Síndrome do Nó Sinusal/fisiopatologia , Síndrome do Nó Sinusal/terapia , Parada Sinusal Cardíaca/diagnóstico , Parada Sinusal Cardíaca/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
19.
Heart Vessels ; 28(1): 120-5, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22354619

RESUMO

We herein present the case of a 60-year-old male with narrow QRS tachycardia who had a remarkable PR prolongation during sinus rhythm. The tachycardia was diagnosed as a slow-fast atrioventricular nodal reentry tachycardia. Slow pathway ablation was performed after the confirmation of the presence of an antegrade fast pathway. Following the elimination of the slow pathway, the PR and atrio-His intervals became shortened from 470 and 420 to 170 and 120 ms, respectively. Moreover, the improvement of atrioventricular conduction after the slow pathway ablation lasted for at least 34 months.


Assuntos
Fascículo Atrioventricular/fisiopatologia , Ablação por Cateter , Eletrocardiografia , Frequência Cardíaca/fisiologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Fascículo Atrioventricular/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia
20.
Heart Vessels ; 28(4): 510-3, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22926410

RESUMO

Plasma B-type natriuretic peptide (BNP) is finely regulated by the cardiac function and several extracardiac factors. Therefore, the relationship between the plasma BNP levels and the severity of heart failure sometimes seems inconsistent. The purpose of the present study was to investigate the plasma BNP levels in patients with cardiac tamponade and their changes after pericardial drainage. This study included 14 patients with cardiac tamponade who underwent pericardiocentesis. The cardiac tamponade was due to malignant diseases in 13 patients and uremia in 1 patient. The plasma BNP levels were measured before and 24-48 h after drainage. Although the patients reported severe symptoms of heart failure, their plasma BNP levels were only 71.2 ± 11.1 pg/ml before drainage. After appropriate drainage, the plasma BNP levels increased to 186.0 ± 22.5 pg/ml, which was significantly higher than that before drainage (P = 0.0002). In patients with cardiac tamponade, the plasma BNP levels were low, probably because of impaired ventricular stretching, and the levels significantly increased in response to the primary condition after drainage. This study demonstrates an additional condition that affects the relationship between the plasma BNP levels and cardiac function. If inconsistency is seen in the relationship between the plasma BNP levels and clinical signs of heart failure, the presence of cardiac tamponade should therefore be considered.


Assuntos
Tamponamento Cardíaco/sangue , Insuficiência Cardíaca/sangue , Peptídeo Natriurético Encefálico/sangue , Biomarcadores/sangue , Tamponamento Cardíaco/diagnóstico , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/fisiopatologia , Tamponamento Cardíaco/cirurgia , Regulação para Baixo , Drenagem/métodos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/complicações , Pericardiocentese , Estudos Retrospectivos , Resultado do Tratamento , Uremia/complicações