RESUMO
OBJECTIVE: To report the experience of Benin, where Buruli ulcer (BU) is endemic, in the implementation of diagnostic laboratory services. METHODS AND RESULTS: There has been a gradual introduction of biologic diagnostic activities for BU comprising (1) training of a laboratory technician in a highly experienced reference laboratory; (2) acquiring indispensable laboratory start-up materials; (3) progressive development of diagnostic laboratory activities; (4) regular external quality assessment with an experienced reference laboratory and (5) decentralization of activities to various clinical diagnostic and treatment centres for BU in Benin. CONCLUSION: Setting up a reference laboratory for BU is a continuous process, which necessitates motivated personnel and the cooperation of an experienced external reference laboratory.