Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Ultrasound Med ; 41(4): 995-1008, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34862641

RESUMO

OBJECTIVES: The aim of this study was to investigate the role of quantitative values obtained by superb microvascular imaging (SMI) and shearwave elastography (SWE) in the prediction of malignancy in intraductal papilloma-like lesions (IDPL). METHODS: In the study, 61 patients between the ages of 14 to 73 years (mean age 44) diagnosed with IDPL on ultrasound (US) examination between the years 2020 and 2021 were included. The B-Mode US findings (shape, margins, size, echo pattern, and accompanying ductal dilatation), SMI vascular index (SMIvi), E-mean, and SWE-ratio values were recorded. RESULTS: There was a statistically significant difference between malignant (n = 14) and benign (n = 47) groups in terms of symptoms (P = .005), size (P = .042), shape (P = .002), margins (P = .001), echogenicity (P = .023), microcalcifications (P = .009), SMIvi (P = .031), E-mean (P < .005), and SWE-ratio (P = .007). According to receiver operating characteristic (ROC) curve analysis, sensitivity, specificity, accuracy, area under the curve (AUC), positive predictive values (PPV), and negative predictive values (NPV) were 57.1%, 87.2%, 80%, 0.722, 57.1%, 87.2% for US; 71.4%, 49%, 55.7%, 0.692, 30.3%, 85.7% for SMIvi; 85.7%, 71%, 74%, 0.864, 46%, 94.3% for E-mean, and 50%, 75.4%, 83%, 0.707, 91.5%, and 50% for SWE-ratio, respectively. Best results were obtained when SMI and SWE values were used together, achieving a sensitivity, specificity, accuracy, AUC, PPD, NPD of 78.6%, 93.6%, 93.4%, 0.872, 91.7%, and 93.9%, respectively. CONCLUSIONS: The SMI and SWE examinations are successful in the differentiation of benign and malignant intraductal lesions. They complement each other and contribute to B-mode US in managing IDPLs especially when used together. Our study is the first to compare the quantitative data of SWE and SMI in the differentiation of IDPLs.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Papiloma Intraductal , Adolescente , Adulto , Idoso , Neoplasias da Mama/patologia , Técnicas de Imagem por Elasticidade/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia Mamária/métodos , Adulto Jovem
2.
Eur Radiol ; 31(3): 1718-1726, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32939619

RESUMO

OBJECTIVES: To investigate the inclusion of breast MRI in radiological assessment of suspicious, isolated microcalcifications detected with mammography. METHODS: In this prospective, multicenter study, cases with isolated microcalcifications in screening mammography were examined with dynamic contrast-enhanced MRI (DCE-MRI) before biopsy, and contrast enhancement of the relevant calcification localization was accepted as a positive finding on MRI. Six experienced breast radiologists evaluated the images and performed the biopsies. Imaging findings and histopathological results were recorded. Sensitivity, specificity, NPV, and PPV of breast MRI were calculated and compared with histopathological findings. RESULTS: Suspicious microcalcifications, which were detected by screening mammograms of 444 women, were evaluated. Of these, 276 (62.2%) were diagnosed as benign and 168 (37.8%) as malignant. Contrast enhancement was present in microcalcification localization in 325 (73.2%) of the cases. DCE-MRI was positive in all 102 invasive carcinomas and in 58 (87.9%) of 66 DCIS cases. MRI resulted in false negatives in eight DCIS cases; one was high grade and the other seven were low-to-medium grade. The false-negative rate of DCE-MRI was 4.76%. The sensitivity, specificity, PPV, and NPV for DCE-MRI for mammography-detected suspicious microcalcifications were 95.2%, 40.2%, 49.2%, and 93.3%, respectively. CONCLUSIONS: In this study, all invasive cancers and all DCIS except eight cases (12.1%) were detected with DCE-MRI. DCE-MRI can be used in the decision-making algorithm to decrease the number of biopsies in mammography-detected suspicious calcifications, with a tradeoff for overlooking a small number of DCIS cases that are of low-to-medium grade. KEY POINTS: • All invasive cancer cases and 87.8% of all in situ cancer cases were detected with MRI, showing a low false-negative rate of 4.7%. • Dynamic contrast-enhanced MRI can be used in the decision-making algorithm to decrease the number of biopsies in mammography-detected suspicious calcifications, with a tradeoff for overlooking a small number of DCIS cases that are predominantly low-to-medium grade. • If a decision for biopsy were made based on MRI findings in mammography-detected microcalcifications in this study, biopsy would not be performed to 119 cases (26.8%).


Assuntos
Neoplasias da Mama , Calcinose , Biópsia , Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Detecção Precoce de Câncer , Feminino , Humanos , Imageamento por Ressonância Magnética , Mamografia , Estudos Prospectivos , Sensibilidade e Especificidade
3.
J Ultrasound Med ; 38(7): 1677-1683, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30426518

RESUMO

OBJECTIVES: The aim of the study was to scrutinize the value of qualitative elastography in the diagnosis of salivary gland masses. METHODS: Sixty patients were enrolled in this prospective study. Patients aged between 1 and 91 years (mean age, 48.8 ± 20.48) with a salivary gland mass were studied with real-time elastography. All patients were examined by 1 examiner, blinded to all relevant data. On elastography, masses were scored into 4 types according to their stiffness compared to normal tissue. Scores of 3 and 4 were accepted as signs of malignancy. Sensitivity, specificity, and positive and negative predictive value were calculated for elastography in verifying malignancy. RESULTS: Forty-two percent of the masses were located in the parotid, and the rest in submandibular gland. The diameter of the lesions varied between 12 and 60 mm (mean, 24.36 ± 11.98 mm). Forty-four masses were benign (73%), and among them the majority were inflammatory lesions (31 of 60; 51.7%). There were 16 malignant lesions (27%). On elastography, not only all malignant lesions but 15 benign lesions were scored as 3 to 4. All masses scored as 1 to 2 were benign. Sensitivity was 100%; specificity, 66%; positive predictive value, 52%; and negative predictive value, 100%. When only Score 4 lesions were accepted as malignant, these values became 75%, 77%, 55%, and 90%, respectively. CONCLUSIONS: Elastography alone cannot be used to discriminate malignant from benign in the evaluation of salivary gland lesions. However, with its high negative predictive value, it may be used as an adjunct tool to increase the diagnostic value of ultrasonography.


Assuntos
Técnicas de Imagem por Elasticidade , Neoplasias das Glândulas Salivares/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Diagnóstico Diferencial , Feminino , Humanos , Lactente , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
4.
Breast J ; 24(6): 992-996, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29781228

RESUMO

To investigate the contribution of breast tomosynthesis to intraoperative specimen evaluation in subjects with breast cancer. Approval was obtained from the hospital ethics committee. Specimen mammography, tomosynthesis, and, if available, ultrasonography images were retrospectively assessed for 208 women who had undergone conservative surgery at our hospital between January 2013 and April 2016 after being diagnosed with breast cancer. The success of mammography, tomosynthesis, and ultrasonography in lesion detection and characterization was evaluated. Of 208 lesions, 142 (68.3%) and 198 (95.2%) were detected by mammography and tomosynthesis, respectively. All lesions were detected in 150 subjects undergoing ultrasonography (124 dense breasts, 26 fatty breasts). In 84 women who had fatty breasts, all lesions were detected both by mammography and by tomosynthesis. In 124 women with dense breasts, lesions were detected by mammography in 59 (48%) and in 114 (92%) by tomosynthesis. The success of tomosynthesis in lesion detection was found to be markedly higher than mammography (P = .00). In conclusion, tomosynthesis contributed to mammography in specimen evaluation in a total of 101 subjects. The success of tomosynthesis in lesion detection and characterization during intraoperative specimen evaluation is higher than mammography. In daily practice, ultrasonography is performed for lesions which cannot be evaluated by specimen mammography due to dense parenchymal pattern. Tomosynthesis may reduce the need for and the time and workforce allocated to specimen ultrasonography in an important group of subjects.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Mamografia/métodos , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/patologia , Feminino , Humanos , Mastectomia Segmentar , Pessoa de Meia-Idade , Ultrassonografia Mamária
5.
Acta Radiol ; 58(12): 1442-1447, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28530138

RESUMO

Background Breast tomosynthesis is more sensitive than mammography and can detect lesions that are not always visible with conventional methods such as digital mammography (MG) and ultrasonography (US). No standardized approach is available for the management of lesions that are detectable with tomosynthesis but are not visible on MG or US. Purpose To review suspicious breast lesions detected with tomosynthesis but not visible on two-dimensional (2D) MG or US and to determine the management options for these lesions. Material and Methods Ethical committee approval was obtained. The radiological records, biopsy or surgery results, and follow-up findings of 107 patients who had a tomosynthesis-positive but MG- or US-negative breast lesion between 2011 and 2016 were retrospectively evaluated. Results Of 107 lesions visible only with tomosynthesis, 74% were architectural distortions and 26% were asymmetrical opacities. All patients underwent magnetic resonance imaging (MRI) for further evaluation. Among the 48 (45%) MRI-negative lesions, none had a suspicious alteration during the follow-up period. Among the MRI-positive lesions, 28% of the 50 architectural distortions and 11% of the nine asymmetrical opacities were malignant. Conclusion Given the inherent high false-positive rate of breast tomosynthesis, breast MRI prior to biopsy may reduce the number of unnecessary biopsies for suspicious breast lesions that are tomosynthesis-positive only.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Adulto , Idoso , Mama/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Ultrassonografia Mamária/métodos
6.
Ultrasound Q ; 39(2): 74-80, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35943392

RESUMO

ABSTRACT: The aim was to evaluate the effectiveness of superb microvascular imaging (SMI) in axillary lymph nodes (LNs).Benign and malignant LNs diagnosed via histopathological examination constituted the study subgroups. In addition to grayscale findings for morphological evaluation, vascular patterns and appearance of internal vessels were analyzed by both power Doppler ultrasound (PDUS) and SMI. The number of vascular branches was counted, and a vascularity index (VI) was calculated by SMI.Fifty-two LNs with suspicious findings in terms of metastasis (33 malignant and 19 benign) were evaluated. Diagnostic accuracy according to vascular patterns was 82% for PDUS and 92% for SMI. In the presence of asymmetric cortical thickening, there was a significant difference between benign and malignant LNs in the number of vascular branches of both thin and thick cortical sides ( P < 0.01). Mean VI was significantly higher in the malignant group ( P < 0.05). In differentiating malignancy, when a cutoff VI value was set to 9%, sensitivity was 69.7%, and specificity was 63.2%.Evaluating the vascularity of axillary LNs by SMI is a useful tool in determining the potential of axillary metastasis, especially in the absence of typical sonographic findings. Superb microvascular imaging can beneficially be used to select the most suspicious LN and suspicious area of the LN to sample.


Assuntos
Microvasos , Ultrassonografia Doppler , Humanos , Sensibilidade e Especificidade , Microvasos/diagnóstico por imagem , Diagnóstico Diferencial , Ultrassonografia Doppler/métodos , Linfonodos/diagnóstico por imagem
7.
Acad Radiol ; 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38087719

RESUMO

RATIONALE AND OBJECTIVES: Artificial intelligence (AI) systems have been increasingly applied to breast ultrasonography. They are expected to decrease the workload of radiologists and to improve diagnostic accuracy. The aim of this study is to evaluate the performance of an AI system for the BI-RADS category assessment in breast masses detected on breast ultrasound. MATERIALS AND METHODS: A total of 715 masses detected in 530 patients were analyzed. Three breast imaging centers of the same institution and nine breast radiologists participated in this study. Ultrasound was performed by one radiologist who obtained two orthogonal views of each detected lesion. These images were retrospectively reviewed by a second radiologist blinded to the patient's clinical data. A commercial AI system evaluated images. The level of agreement between the AI system and the two radiologists and their diagnostic performance were calculated according to dichotomic BI-RADS category assessment. RESULTS: This study included 715 breast masses. Of these, 134 (18.75%) were malignant, and 581 (81.25%) were benign. In discriminating benign and probably benign from suspicious lesions, the agreement between AI and the first and second radiologists was moderate statistically. The sensitivity and specificity of radiologist 1, radiologist 2, and AI were calculated as 98.51% and 80.72%, 97.76% and 75.56%, and 98.51% and 65.40%, respectively. For radiologist 1, the positive predictive value (PPV) was 54.10%, the negative predictive value (NPV) was 99.58%, and the accuracy was 84.06%. Radiologist 2 achieved a PPV of 47.99%, NPV of 99.32%, and accuracy of 79.72%. The AI system exhibited a PPV of 39.64%, NPV of 99.48%, and accuracy of 71.61%. Notably, none of the lesions categorized as BI-RADS 2 by AI were malignant, while 2 of the lesions classified as BI-RADS 3 by AI were subsequently confirmed as malignant. By considering AI-assigned BI-RADS 2 as safe, we could potentially avoid 11% (18 out of 163) of benign lesion biopsies and 46.2% (110 out of 238) of follow-ups. CONCLUSION: AI proves effective in predicting malignancy. Integrating it into the clinical workflow has the potential to reduce unnecessary biopsies and short-term follow-ups, which, in turn, can contribute to sustainability in healthcare practices.

8.
Acad Radiol ; 30(6): 1107-1117, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36357304

RESUMO

RATIONALE AND OBJECTIVES: Adenoid cystic carcinoma (ACC) of the breast is a rare type of breast cancer with favorable prognosis. There is limited data on the radiological findings of this rare tumor in literature. The aim of this study is to determine the most common imaging features and review the literature. MATERIALS AND METHODS: Pathological databases of seven institutions from 2009 to 2021 were retrospectively reviewed, and patients with a diagnosis of ACC of the breast were determined. Thirteen patients whose imaging studies could be recalled from the picture archiving systems (PACS) were included in the study. Clinical and pathological findings as well as follow-up data were recorded. Radiological findings were analyzed and categorized based on BI-RADS 5th edition. RESULTS: There were 16 mass lesions in 13 patients (two multifocal cases, one case with recurrence). Mammography demonstrated 14 masses, while ultrasound (US) demonstrated all. MRI was available in only seven cases, with eight masses. The most common findings were round or oval shape on all modalities (78.57%-93.75%). Other frequent findings were parallel orientation (81.25%), isoechoic or hyperechoic echogenicity (62.5%), high T2 signal (87.5%), restricted diffusion (71.43%), and homogeneous enhancement (62.5%). Mammography, US and MRI showed circumscribed margins resembling a benign lesion in 35.71%, 37.5% and 50% of the lesions respectively. Three patients had a cyst-like echogenicty on US. Half of the lesions were avascular on Doppler US (6/12) and half were soft (2/4) on strain elastography. Although there were benign features on all imaging modalities seperately, all lesions could be categorized as BI-RADS 4 or 5 when the findings were combined. However 9/16 masses were BI-RADS 4A, emphasizing the subtlety of the malignant features. CONCLUSION: ACC of the breast can present with findings resembling a benign lesion on different imaging modalities. Although combination of all imaging findings correctly indicated the suspicious nature of the lesions in all cases, final classification was BI-RADS 4A in most of them. Radiologists should be aware of the more frequent findings of ACC of the breast for early diagnosis. US findings of isoechoic or hyperechoic appearance, and cyst-like echogenicity have not been reported previously in literature.


Assuntos
Neoplasias da Mama , Carcinoma Adenoide Cístico , Cistos , Feminino , Humanos , Carcinoma Adenoide Cístico/diagnóstico por imagem , Estudos Retrospectivos , Ultrassonografia Mamária/métodos , Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Mamografia
9.
Diagn Interv Radiol ; 29(4): 579-587, 2023 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-36994925

RESUMO

PURPOSE: The clinical management of high-risk lesions using image-guided biopsy is challenging. This study aimed to evaluate the rates at which such lesions were upgraded to malignancy and identify possible predictive factors for upgrading high-risk lesions. METHODS: This retrospective multicenter analysis included 1.343 patients diagnosed with high-risk lesions using an image-guided core needle or vacuum-assisted biopsy (VAB). Only patients managed using an excisional biopsy or with at least one year of documented radiological follow-up were included. For each, the Breast Imaging Reporting and Data System (BI-RADS) category, number of samples, needle thickness, and lesion size were correlated with malignancy upgrade rates in different histologic subtypes. Pearson's chi-squared test, the Fisher-Freeman-Halton test, and Fisher's exact test were used for the statistical analyses. RESULTS: The overall upgrade rate was 20.6%, with the highest rates in the subtypes of intraductal papilloma (IP) with atypia (44.7%; 55/123), followed by atypical ductal hyperplasia (ADH) (38.4%; 144/375), lobular neoplasia (LN) (12.7%; 7/55), papilloma without atypia (9.4%; 58/611), flat epithelial atypia (FEA) (8.7%; 10/114), and radial scars (RSs) (4.6%; 3/65). There was a significant relationship between the upgrade rate and BI-RADS category, number of samples, and lesion size Lesion size was the most predictive factor for an upgrade in all subtypes. CONCLUSION: ADH and atypical IP showed considerable upgrade rates to malignancy, requiring surgical excision. The LN, IP without atypia, pure FEA, and RS subtypes showed lower malignancy rates when the BI-RADS category was lower and in smaller lesions that had been adequately sampled using VAB. After being discussed in a multidisciplinary meeting, these cases could be managed with follow-up instead of excision.


Assuntos
Neoplasias da Mama , Carcinoma Intraductal não Infiltrante , Humanos , Feminino , Biópsia com Agulha de Grande Calibre/métodos , Estudos Retrospectivos , Neoplasias da Mama/patologia , Biópsia Guiada por Imagem/métodos
10.
J Clin Ultrasound ; 40(5): 261-5, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22508447

RESUMO

PURPOSE: To describe the sonographic (US) features associated with ultrasonography BI-RADS category 4 lesions that have a benign histopathological outcome. METHODS: One hundred seventy-two histopathologically proven benign lesions in 169 patients, which had been classified as BI-RADS category 4 with ultrasonography, were retrospectively evaluated. Ultrasonography and histopathology findings were analyzed. The frequency of sonographic findings according to the histopathological diagnosis was determined. RESULTS: Among the 172 lesions, there were 66 (38%) fibroadenomas, 31 (18%) sclerosing adenoses, 24 (14%) fibrocystic changes, 16 (9%) mastitis/inflammations, 9 (5.5%) intraductal papillomas, 8 (5%) focal fibroses, 4 (2.5%) atypical ductal hyperplasias, 4 (2.5%) fat necroses, 2 (1%) phyllodes tumors, 1 (0.5%) tubular adenomas, 1 (0.5%) epidermal inclusion cysts, and 6 (3.5%) "other benign lesions." The most frequent sonographic findings were heterogeneity, indistinct margin, microlobulation in fibroadenomas; heterogeneity, irregular-indefinite margin, and antiparallel orientation in sclerosing adenosis; heterogeneity, microlobulation, and acoustic shadowing in fibrocystic changes. CONCLUSIONS: BI-RADS category 4 lesions demonstrate more than one suspicious ultrasonography feature, and biopsy is necessary to diagnose malignancy captured in 33% of lesions in this study. At this time, any lesion with more than one suspicious BI-RADS US feature cannot avoid a diagnostic biopsy.


Assuntos
Neoplasias da Mama/classificação , Neoplasias da Mama/diagnóstico por imagem , Mama/patologia , Ultrassonografia Mamária/métodos , Adulto , Idoso , Biópsia por Agulha , Neoplasias da Mama/patologia , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Adulto Jovem
11.
Clin Imaging ; 84: 47-53, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35134676

RESUMO

PURPOSE: To evaluate magnetic resonance imaging (MRI) findings related to recurrence of idiopathic granulomatous mastitis (IGM). METHODS: Demographic data [age, number of births, duration of lactation period, body mass index (BMI) and presence of recurrence] of 71 patients who were diagnosed with IGM were analyzed retrospectively. Characteristics of IGM (maximum width, location, involvement of the retroareolar region, deep tissue, skin), fibroglandular density (FGD), background parenchymal enhancement (BPE), distribution and pattern of contrast enhancement, presence of prepectoral edema, abscesses, fistulae, axillary lymphadenopathies on MRI and apparent diffusion coefficient (ADC) values from the pathological area were recorded. RESULTS: The recurrence rate in patients was 59% (42/71). We found a statistically significant relationship between recurrence and BPE (p = 0.028) and mean ADC (p = 0.035) values (for the cut-off of 1.00 × 10-3 mm2/s; sensitivity = 61.9%, specificity = 69%, AUC = 0.648). However, patients' age (p = 0.346), lactation period (p = 0.470), number of births (p = 0.774), BMI (p = 0.630) maximum width of the area of enhancement (p = 0.112), involvement of the retroareolar region (p = 0.290), deep tissue (p = 0.285), skin (p = 0.230), distribution (p = 0.857) and enhancement pattern (p = 0.157), presence of prepectoral edema (p = 0.094), abscesses (p = 0.441), fistulae (p = 0.809), lymphadenopathies (p = 0.571), and FGT (p = 0.098) were not significantly associated with recurrence. CONCLUSION: Our results revealed that recurrent IGM patients showed high BPE and lower mean ADC values. We think that high BPE and low mean ADC (<1.00 × 10-3 mm2/s) on MRI at the diagnosis stage may be a sign of possible future recurrence, and it will be beneficial to follow the patients more closely and arrange the treatment algorithms accordingly.


Assuntos
Neoplasias da Mama , Mastite Granulomatosa , Abscesso , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Mastite Granulomatosa/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos
12.
Curr Probl Diagn Radiol ; 49(6): 417-421, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31351695

RESUMO

OBJECTIVE: To determine the preoperative MRI findings of patients with breast cancer according to molecular subtypes. MATERIALS AND METHODS: MRI findings of women diagnosed with breast cancer in our department between January 2013 and June 2017 who had preoperative breast MRI examinations were evaluated and histopathological findings were recorded retrospectively. The findings were classified according to the BI-RADS MRI classification by three radiologists. Correlations of MRI findings with the molecular subtypes were evaluated using Chi-square and t-tests. RESULTS: Among 234 lesions in a total of 224 cases diagnosed with breast cancer, subtypes of breast cancer as following: Luminal (162 cases, 69%), triple negative (39 cases, 17%) and HER2 positive (33 cases, 14%), respectively. Lesions of patients with luminal, triple negative and HER2 positive invasive ductal cancer were round or lobular in shape (9.9%, 42.9%, 20.7%), had high/very high intratumoral T2 signal intensity (24.8%, 54.2%, 31%) and rim enhancement pattern (9.2%, 51.4%, 24.1%), respectively. The difference between the triple negative cases and the other subtypes was statistically significant (p < 0.05). CONCLUSION: One of the most important factors that determine the prognosis and treatment in breast cancer is the molecular subtype of the tumor. Morphologic findings of MRI can be a useful tool for differentiating triple negative breast cancer from other subtypes.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/cirurgia , Meios de Contraste , Feminino , Humanos , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos
13.
Clin Imaging ; 58: 182-186, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31404824

RESUMO

PURPOSE: Pregnancy-associated breast cancer (PABC) is a rare disease. However, its expected incidence tends to be increased because of delayed maternal age. The purpose of this study was to describe the clinical, radiological, and histopathological characteristics of PABC cases diagnosed in our center. METHODS: The clinical-radiological findings and histopathological characteristics of patients diagnosed and treated with PABC at our institution between January 2011 and January 2017 were retrospectively evaluated. RESULTS: Mammography and ultrasonography were performed in all patients. MRI examination was performed in 18 patients. Nine (19.1%) out of 47 patients were diagnosed with breast cancer during pregnancy, and 38 (80.9%) were in their first year after delivery. The most frequent finding (95.7%) during imaging was one or more masses. Mammography-detected pure or accompanying microcalcifications were found in 12 (25.5%) patients. MRI detected additional multifocal and multicentric disease in 14 (29.8%) patients and contralateral cancer in one (2.1%) patient. CONCLUSIONS: Pregnancy-related breast cancer tends to be diagnosed in an advanced stage with poor prognosis. Any breast abnormalities observed in this period should alert clinicians, and a meticulous radiological evaluation is mandatory. The early diagnosis of this disease would increase the chances of successful treatment.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Complicações Neoplásicas na Gravidez/diagnóstico por imagem , Adulto , Neoplasias da Mama/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Mamografia/métodos , Imagem Multimodal , Gravidez , Estudos Retrospectivos
14.
Diagn Interv Radiol ; 24(5): 255-261, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30211678

RESUMO

PURPOSE: We aimed to evaluate the findings and results from breast magnetic resonance imaging (MRI) examinations performed for problem-solving purposes due to inconclusive conventional imaging findings. METHODS: Imaging findings, biopsy and follow-up results were retrospectively evaluated for breast MRI performed for problem-solving purposes at our department between January 2011 and December 2016 for cases whose mammography, tomosynthesis, or ultrasonography findings were inconclusive. RESULTS: Lesions were identified in 414 of 986 problem-solving MRI examinations, and 13.3% of these lesions were diagnosed as malignant. A total of 124 lesions were additionally found by MRI, and 9.7% of these lesions were diagnosed as malignant. MRI produced false-negative results in four cases. In cases whose conventional imaging methods yielded indefinite results, the sensitivity, specificity, negative and positive predictive values of MRI were found to be 96.3%, 83%, 99.3%, and 46.5%, respectively. For the additional lesions identified, the sensitivity, specificity, negative and positive predictive values of MRI were found to be 91.7%, 69%, 98.7%, and 24%, respectively. CONCLUSION: Breast MRI is a reliable problem-solving method for excluding malignancy that cannot be confirmed by conventional imaging. In such cases, additional findings from MRI may help identify new cancers that cannot be detected with conventional methods. However, it has moderately low specificity which may cause unnecessary biopsies, follow-ups, and anxiety to patients.


Assuntos
Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Resolução de Problemas , Adulto , Idoso , Biópsia , Mama/patologia , Neoplasias da Mama/patologia , Diagnóstico Diferencial , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Mamografia/métodos , Mamografia/estatística & dados numéricos , Pessoa de Meia-Idade , Neoplasias/diagnóstico por imagem , Neoplasias/patologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Ultrassonografia/métodos , Ultrassonografia/estatística & dados numéricos
15.
Tuberk Toraks ; 55(3): 253-8, 2007.
Artigo em Turco | MEDLINE | ID: mdl-17978922

RESUMO

The aim of this study was to search for the conspicuity, shape and size of posterior portion of superior pericardial recess (SPR) on routine spiral chest computed tomography (CT). Chest CTs of 180 consecutive patients were reviewed for the presence of the posterior portion of SPR, retrospectively. All images were reevaluated on a workstation by two radiologists in consensus with a constant window setting (window level 50 HU, window width 350 HU). Uniform, sharply outlined structure of near water density, without walls and rims in the posterior aspect of the ascending aorta was defined as posterior portion of the SPR. Identifiable recesses were classified as linear, crescentic, semicircle and amorphous in appearance. The depth of the recess was measured. Pericardial thickness, diameters of ascending and descending aorta, and pulmonary artery and its major branches were noted. Statistical analyses were performed to scrutinize any relationship between the presence of the recess, its shape, depth, gender, pericardial thickness and diameters of thoracic vessels. The recess was identified in 174 (96%) patients. Seventy-nine (45%) recesses were semicircular, 47 (27%) linear, 39 (23%) amorphous and 9 (5%) crescentic. The mean depth was 6 +/- 3.5 mm. The mean diameter of ascending, descending aorta, and pulmonary artery and its main branches were 33.6 +/- 5 mm, 25.7 +/- 3.7 mm, 23.2 +/- 2.6 mm, 19.2 +/- 2.6 mm, and 19.3 +/- 2.6 mm, respectively. The mean pericardial thickness was 2.7 +/- 0.6 mm. The shape and depth of the recess did not correlate with age, gender, vascular diameters and pericardial thickness. The posterior portion of SPR may be encountered in the majority of patients. Conspicuity of the recess may be due to individual variability.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Pericárdio/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos
16.
Diagn Interv Radiol ; 23(5): 333-338, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28830847

RESUMO

PURPOSE: We aimed to assess the effectiveness of magnetic resonance imaging (MRI)-guided vacuum-assisted breast biopsy (VABB), evaluate and compare the characteristics and histopathologic findings of lesions, and overview the follow-up results of benign lesions. METHODS: MRI findings and histopathologic results of breast lesions biopsied by MRI-guided VABB between 2013 and 2016 were retrospectively analyzed. MRI findings closely related with malignancy were investigated in particular. Follow-up results of benign lesions were evaluated. RESULTS: MRI-guided VABB was applied to 116 lesions of 112 women. Of the lesions, 75 (65%) were benign, while 41 (35%) were malignant. Segmental (94%), clustered (89%), and clustered ring (67%) non-mass-like enhancement patterns were found to be more related with malignancy. False-negative rate of MRI-guided VABB was 12%, underestimation rate was 21%. One of the 54 followed-up benign lesions had a malignant result. CONCLUSION: MRI-guided VABB is a reliable method for the diagnosis of breast lesions that are positive only on MRI. Follow-up results show that cancer detection rate is low for radio-pathologically concordant lesions. Further multicenter studies with larger patient population are needed to elucidate these results.


Assuntos
Neoplasias da Mama/patologia , Imagem por Ressonância Magnética Intervencionista/métodos , Adulto , Idoso , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Biópsia Guiada por Imagem/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
17.
Eur J Radiol ; 60(2): 250-5, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16890393

RESUMO

PURPOSE: To determine the prevalence of breast arterial calcifications (BAC) detected on mammography and search for conditions that may influence their existence. MATERIALS AND METHODS: The mammograms of 6156 consecutive patients were reevaluated for the presence of BAC. Four hundred eighty-five women having BAC were enrolled in the patient group. Additionally, randomly selected 500 women, without BAC constituted the control group. Hospital records of the participants were reviewed for parity, menopausal status, oral contraceptive agent (OCA) usage, hormone replacement therapy (HRT) usage, presence of diabetes, hypertension, hyperlipidemia, albuminuria and history of myocardial infarction (MI). RESULTS: Prevalence of BAC was 7.9% on mammograms. Ninety-four women were aged between 40 and 49 years, 165 were aged between 50 and 59 years and 226 were over 60 years among BAC positive 485 women. A significant relationship was found for the frequency of BAC versus age and HRT usage in all age groups (p<0.05). Similarly, significant relationships were also found for the frequency of BAC versus OCA usage, HRT usage, hyperlipidemia and diabetes in age group of 40-49 and in age group of 50-59, and for the frequency of BAC versus albuminuria in age group of 40-49, BAC versus history of myocardial infarction in age group of 59-59 and over 60 years (p<0.05). The correlations were not significant for the relationships of BAC with OCA usage, hyperlipidemia, diabetes and albuminuria in women over 60 years (p>0.05). CONCLUSION: Most benign findings like BAC are not routinely reported during mammographic evaluation. Our study showed that, presence of BAC on mammography was strongly related to advancing age. However, these findings may signify a systemic risk and can be used as precautious indicators for undocumented systemic diseases, especially in premenopausal women.


Assuntos
Arteriosclerose/diagnóstico por imagem , Arteriosclerose/patologia , Doenças Mamárias/diagnóstico por imagem , Doenças Mamárias/patologia , Calcinose/diagnóstico por imagem , Calcinose/patologia , Mamografia , Adulto , Distribuição por Idade , Albuminúria/complicações , Análise de Variância , Arteriosclerose/complicações , Arteriosclerose/epidemiologia , Doenças Mamárias/complicações , Doenças Mamárias/epidemiologia , Calcinose/complicações , Calcinose/epidemiologia , Anticoncepcionais Orais/administração & dosagem , Anticoncepcionais Orais/efeitos adversos , Estudos Transversais , Complicações do Diabetes/diagnóstico por imagem , Feminino , Terapia de Reposição Hormonal/efeitos adversos , Humanos , Hiperlipidemias/complicações , Hipertensão/complicações , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Pós-Menopausa , Pré-Menopausa , Prevalência , Fatores de Risco , Turquia/epidemiologia
18.
Eur J Radiol ; 57(1): 154-7, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16162396

RESUMO

PURPOSE: To evaluate the varicocele frequency of patients with spinal cord injury by color Doppler ultrasonography. MATERIALS AND METHODS: Sixty patients {48 patients with upper motor neuron injury (U-MNI) and 12 patients with lower-MNI} with traumatic spinal cord injury and age matched 48 healthy volunteers were enrolled in this prospective study. Testis volumes and varicocele grades were determined. Presence of varicocele was also classified according to clinical significance. RESULTS: Testis volumes of U-MNI sub-group (14.81 +/- 4.74 ml) were significantly smaller than the control group (18.20 +/- 4.52 ml, p = 0.000) and L-MNI sub-group (17.88 +/- 3.23 ml, p = 0.008). No left-sided clinical varicocele was found in L-MNI sub-group (0/12, 0%), whereas there were 14 patients in control group (14/48, 29%) and 7 patients in U-MNI sub-group (7/47, 15%), and the difference was statistically significant (p = 0.000, 0.007, respectively). CONCLUSION: Clinical varicocele frequency of U-MNI patients, who have spastic paralysis of abdominal and lower extremity muscles, is similar to the control group. This finding inspires that increased intra-abdominal pressure via normal to increased abdominal muscle tonus may have a role in the varicocele etiology, beside the classical factors. Absence of clinical varicocele in L-MNI patients, who have flaccid paralysis of the same muscle groups, supports this observation.


Assuntos
Traumatismos da Medula Espinal/complicações , Ultrassonografia Doppler em Cores , Varicocele/diagnóstico por imagem , Varicocele/etiologia , Adulto , Estudos de Casos e Controles , Humanos , Masculino , Estudos Prospectivos
19.
Diagn Interv Radiol ; 12(4): 166-70, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17160797

RESUMO

PURPOSE: To determine the quality of radiographs, which have been referred from 40 different institutions for consultation, to discuss the causes of wasted resources, and to present possible solutions. MATERIALS AND METHODS: Five experienced radiology instructors determined the types of radiological examinations referred for consultation (conventional radiography, mammography, computed tomography and magnetic resonance imaging), the institutions at which they were performed (university or state hospital, private health center), and assessed the coverage area, field of vision (FOV), and dosage of x-ray. They also investigated problems in film processing, defects in sequence-printing windows, checked window levels, and checked the amount and timing of contrast material used. According to these criteria, the reviewers subjectively classified each radiograph as: 1. Poor, examination should be completely repeated, 2. Fair, examination should be partially repeated, 3. Good, accepted as adequate, no need for an additional examination, 4. Excellent, examination was as it should be. RESULTS: We reviewed 120 radiological examinations from 40 different institutions in 4 reference centers. Frequency of problems determined for each category was as follows: coverage area 32.5% (39/120), FOV 16% (14/86), X-ray dosage 16% (15/94), film processing 31% (37/120), sequence or window 65% (53/81), window level 44% (36/81); contrast material 51% (25/49), timing of contrast material 61% (30/49). Only 22% of the examinations were classified as excellent, whereas 47% required complete or partial repetition. CONCLUSION: Approximately half of the radiological examinations in our sampling required partial or complete repetition. Health, ethical, and economic aspects of the problem necessitates the prompt application of measures to establish radiological quality control and standardization procedures.


Assuntos
Benchmarking , Avaliação de Processos e Resultados em Cuidados de Saúde , Radiografia/normas , Humanos , Variações Dependentes do Observador , Controle de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Interpretação de Imagem Radiográfica Assistida por Computador , Encaminhamento e Consulta/normas , Turquia
20.
Eur J Radiol ; 54(3): 388-92, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15899341

RESUMO

OBJECTIVE: Localized low attenuated areas (pseudolesions) in the medial segment of left liver lobe are not rarely seen in the screening of abdomen using helical CT. The purpose of this study was to determine the prevalence of pseudolesions in the routine helical CT of abdomen and to evaluate the morphologic and enhancement features of pseudolesions in the unenhanced and enhanced CT examinations. MATERIALS AND METHODS: We retrospectively evaluated 333 contrast enhanced abdominal CT examination of 328 patients with no known liver disease, to detect the presence of pseudolesion of liver. In the presence of unenhanced and arterial phase examinations, these images were also analyzed. The imaging criteria for pseudolesion of liver was localized low attenuated area with geometric, ovoid or nodular shaped and with no mass effect adjacent to the falciform ligament, gallbladder, or porta hepatis. Previous CT, CTAP and MR examinations were also reviewed to understand the evolution of pseudolesion in patients in whom a pseudolesion was detected in the portal phase of helical CT examination. RESULTS: We identified a pseudolesion in the 65 (19.8%) of 328 patients in portal phase of helical CT examinations. Pseudolesions were identified in the medial segment of left liver lobe adjacent to falciform ligament in the 92.8% of patients, both sides of falciform ligament in the 1.5% of patients, adjacent to porta hepatis in the 3% of patients and adjacent to gallbladder 3% of patients. These lesions had triangular shape in the 66.1% of patients, ovoid shape in the 18.6% of patients, and nodular shape in the 15.3% of patients. Unenhanced, arterial and portal phase images were exist in the 50.7% of 65 patients. The pseudolesions were not identified on the unenhanced images in the 75.7% of patients and on the arterial phase images in the 55.6% of patients. CONCLUSION: Pseudolesions around the falciform ligament are not rarely seen in the routine helical CT examination of liver and abdomen. The pseudolesions are more encountered in the portal phase of helical CT examination. These lesions seem to be likely focal fatty infiltration or perfusion defect due to venous supply variation or both. Nodular shaped pseudolesions may be interpreted as true tumors and further study may require for differential diagnosis.


Assuntos
Hepatopatias/diagnóstico por imagem , Tomografia Computadorizada Espiral , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Diagnóstico Diferencial , Fígado Gorduroso/diagnóstico por imagem , Feminino , Humanos , Iohexol/análogos & derivados , Ligamentos/diagnóstico por imagem , Hepatopatias/patologia , Masculino , Pessoa de Meia-Idade , Prevalência , Radiografia Abdominal , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA