1.
J Thorac Cardiovasc Surg ; 120(1): 142-7, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10884667

RESUMO

BACKGROUND: Obstruction of the St Jude Medical valve (St Jude Medical, Inc, St Paul, Minn) is a rare but serious complication. METHODS: Cineradiographic and echocardiographic evaluations of aortic St Jude Medical valves were simultaneously performed on 54 patients, with no signs of prosthetic valve dysfunction late after surgery. RESULTS: Although closing angles of the leaflets corresponded closely with the manufacturer data, restricted opening of the leaflets (opening angle >/= 20 degrees ) was found in 16 (group D) of the 54 patients by means of cineradiography. The opening angles were equal to or less than 14 degrees in the other 23 patients (group N) and between 15 degrees and 19 degrees in the remaining 15 (group M). Doppler-derived transprosthetic pressure gradients were significantly higher (P =.03) and the velocity index was significantly lower (P =.003) in group D than in group N. However, no significant differences were found in those values between group N and group M. Replacement of the aortic St Jude Medical valves was performed in 5 of the 16 patients, and the remaining 11 have been followed up because of relatively low pressure gradients. The cause of restricted leaflet movement was pannus formation without thrombosis in 4 patients and valve thrombosis with pannus formation in one. CONCLUSIONS: Reduced valve orifice area and restricted opening of the leaflets resulting from excess growth of pannus probably led to obstruction of the aortic St Jude Medical valves. A combination of cineradiography and echocardiography makes it possible to provide an accurate and detailed diagnosis of obstruction of the valve.


Assuntos
Cinerradiografia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/diagnóstico por imagem , Falha de Prótese , Adolescente , Adulto , Idoso , Valva Aórtica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Ultrassonografia
2.
J Heart Lung Transplant ; 14(1 Pt 1): 113-8, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-7537098

RESUMO

BACKGROUND: We compared the severity of cardiac allograft vascular disease in rats treated with cyclosporine or FK506 and studied the effect of antithrombotic agents on cardiac allograft vascular disease. METHODS: One group each was treated with 2 and 5 mg/kg/day of cyclosporine. Two other groups were injected with heparin and dipyridamole, respectively, in addition to cyclosporine. Four other groups were similarly divided by dose of FK506 (0.1 or 0.25 mg/kg/day) and concomitant anticoagulant treatment. RESULTS: Grade of rejection and percentage stenosis of coronary arteries were lower in groups with high doses of immunosuppressive agents or with heparin. Major histocompatibility class II antigens were expressed by the endothelium of grafted hearts, and IgM and C3 were deposited in the intimal and medial layers in all groups except those administered the higher doses of immunosuppressive drugs. However, no remarkable differences in density of major histocompatibility class II antigens were found between groups demonstrating expression of these antigens. On the other hand, the intensity of IgM or C3 expression grew significantly as coronary stenosis increased in severity. CONCLUSIONS: A significant difference in severity of cardiac allograft vascular disease was not found between the groups treated with cyclosporine and FK506, and cardiac allograft vascular disease was almost entirely suppressed when doses of cyclosporine and FK506 sufficient to suppress graft rejection were administered. Our findings also showed that concomitant heparin administration reduced the extent of allograft rejection and the incidence of cardiac allograft vascular disease.


Assuntos
Doença das Coronárias/etiologia , Ciclosporina/uso terapêutico , Dipiridamol/uso terapêutico , Rejeição de Enxerto/prevenção & controle , Transplante de Coração/efeitos adversos , Heparina/uso terapêutico , Tacrolimo/uso terapêutico , Animais , Complemento C3/imunologia , Doença das Coronárias/imunologia , Doença das Coronárias/prevenção & controle , Vasos Coronários/patologia , Ciclosporina/administração & dosagem , Quimioterapia Combinada , Transplante de Coração/imunologia , Antígenos de Histocompatibilidade Classe II/imunologia , Imunoglobulina M/imunologia , Masculino , Ratos , Ratos Endogâmicos ACI , Ratos Endogâmicos Lew , Tacrolimo/administração & dosagem , Transplante Heterotópico
3.
Ann Thorac Surg ; 70(2): 627-32, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10969691

RESUMO

BACKGROUND: Effects of captopril, an angiotensin-converting enzyme inhibitor, during warm blood cardioplegia were assessed in the blood-perfused, isolated rat heart. METHODS: The isolated hearts were arrested for 60 minutes with warm blood cardioplegia given at 20-minute intervals and were reperfused for 60 minutes. The control group (n = 10) received standard cardioplegia and the captopril group (n = 10) received cardioplegia supplemented with captopril (2 mmol/L). Cardiac function, myocardial metabolism, and cardiac release of circulating adhesion molecules were assessed before and after cardioplegic arrest. RESULTS: Left ventricular end-diastolic pressure and -dp/dt were significantly (p<0.05) lower and coronary blood flow was significantly (p<0.05) greater in the captopril group than the control group during reperfusion. The captopril group resulted in significantly (p<0.05) less cardiac release of lactate, thiobarbituric acid reactive substances during reperfusion. Cardiac release of intercellular adhesion molecule-1 was significantly (p<0.05) less in the captopril group at 60 minutes of reperfusion. CONCLUSIONS: The results suggest that supplementation of captopril during warm blood cardioplegia provides superior myocardial protection by suppressing lipid peroxidation and leukocyte-endothelial cell interaction during reperfusion.


Assuntos
Inibidores da Enzima Conversora de Angiotensina/farmacologia , Captopril/farmacologia , Parada Cardíaca Induzida , Coração/efeitos dos fármacos , Animais , Parada Cardíaca Induzida/métodos , Técnicas In Vitro , Peroxidação de Lipídeos/efeitos dos fármacos , Ratos , Ratos Wistar , Função Ventricular Esquerda/efeitos dos fármacos , Pressão Ventricular/efeitos dos fármacos
4.
Ann Thorac Surg ; 68(5): 1661-7, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10585039

RESUMO

BACKGROUND: It has been suggested that cyclic adenosine monophosphate-elevating agents suppress cytokine production. To evaluate the effects of milrinone, a phosphodiesterase III inhibitor, on cytokine production after cardiopulmonary bypass, we conducted a prospective randomized study. METHODS: Twenty-four patients undergoing coronary artery bypass grafting were randomized to receive either milrinone treatment (milrinone, n = 12) or no milrinone treatment (control, n = 12). Administration of milrinone (0.5 microg x kg(-1) x min(-1)) was started after induction of anesthesia and was continued for 24 hours. Blood samples for determination of plasma cyclic adenosine monophosphate, tumor necrosis factor-alpha, interleukin-1beta, interleukin-6, and interleukin-8 levels were collected perioperatively. RESULTS: No significant differences were observed in tumor necrosis factor-alpha and interleukin-8 levels between the groups. Interleukin-1beta and interleukin-6 levels after cardiopulmonary bypass were significantly (p < 0.05) lower in the milrinone group than in the control group. Plasma levels of cyclic adenosine monophosphate increased significantly (p < 0.05) after the administration of milrinone and the levels correlated inversely (r = -0.55, p < 0.01) with interleukin-6 levels. CONCLUSIONS: The results indicate that milrinone suppresses cytokine production by elevating cyclic adenosine monophosphate levels in patients undergoing cardiopulmonary bypass. With its positive inotropic and vasodilator activities, milrinone may have antiinflammatory effects.


Assuntos
Ponte de Artéria Coronária , Citocinas/antagonistas & inibidores , Milrinona/administração & dosagem , Inibidores de Fosfodiesterase/administração & dosagem , Complicações Pós-Operatórias/prevenção & controle , Síndrome de Resposta Inflamatória Sistêmica/prevenção & controle , Idoso , Creatina Quinase/sangue , AMP Cíclico/sangue , Citocinas/sangue , Feminino , Hemodinâmica/efeitos dos fármacos , Hemodinâmica/fisiologia , Humanos , Infusões Intravenosas , Isoenzimas , Masculino , Pessoa de Meia-Idade , Milrinona/efeitos adversos , Inibidores de Fosfodiesterase/efeitos adversos , Complicações Pós-Operatórias/imunologia , Estudos Prospectivos , Síndrome de Resposta Inflamatória Sistêmica/imunologia
5.
Ann Thorac Surg ; 70(4): 1319-26, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11081892

RESUMO

BACKGROUND: Biological activity of endogenous atrial natriuretic peptide (ANP) may decrease during cardiopulmonary bypass. To evaluate the effects of intraoperative administration of exogenous ANP in patients undergoing cardiopulmonary bypass, we conducted a prospective randomized study. METHODS: Eighteen patients undergoing mitral valve surgery were randomized to receive either ANP treatment (ANP group; n = 9) or no ANP treatment (control group; n = 9). Atrial natriuretic peptide was given immediately after initiation of cardiopulmonary bypass for 6 hours (0.05 microg x kg(-1) x min(-1)). Plasma ANP, brain natriuretic peptide and cyclic guanosine monophosphate (cGMP) levels, hemodynamic variables and renal function were assessed perioperatively. RESULTS: Administration of ANP increased plasma cyclic guanosine monophosphate levels, urine output and fractional sodium excretion, and decreased preload, afterload and plasma brain natriuretic peptide levels significantly (p < 0.05). Plasma cyclic guanosine monophosphate levels correlated with plasma ANP levels (r = 0.95, p = 0.0001), correlated with fractional sodium excretion (r = 0.53, p = 0.02), and correlated inversely with systemic vascular resistance (r = -0.54, p = 0.02). CONCLUSIONS: Intraoperative administration of ANP had potent effects on natriuresis and systemic vasodilation by elevating cyclic guanosine monophosphate levels. The results suggest that the technique is useful for the management of hemodynamics and water-sodium retention after cardiopulmonary bypass.


Assuntos
Fator Natriurético Atrial/administração & dosagem , Ponte Cardiopulmonar , Diuréticos/administração & dosagem , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/cirurgia , Fragmentos de Peptídeos/administração & dosagem , Adulto , Idoso , GMP Cíclico/sangue , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Natriurese/efeitos dos fármacos , Estudos Prospectivos , Vasodilatação/efeitos dos fármacos
6.
Ann Thorac Surg ; 72(6): 1945-9, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11789776

RESUMO

BACKGROUND: Cimetidine, which is usually used for gastric ulcer, enhances cellular immunity. The effect of cimetidine on perioperative proinflammatory response after cardiac surgery with cardiopulmonary bypass was investigated. METHODS: Elective coronary artery bypass graft cases in which CPB was performed were placed randomly in a cimetidine (C) group (n = 20) or a no-treatment (N) group (n = 20). The time course of plasma levels of neutrophil elastase, interleukin (IL)-6 and IL-8, leukocyte counts, lymphocyte recovery ratio, C-reactive protein, creatine-kinase-MB, and oxygenation index were analyzed. RESULTS: The plasma levels of neutrophil elastase and IL-8 were inhibited in the C groups at 2 hours after CPB termination. In a comparison of the two groups, the C group demonstrated higher lymphocyte recovery ratio and lower C-reactive protein on postoperative day 5 and shorter intubation time. No intergroup differences were observed in IL-6, leukocyte counts, creatine-kinase-MB levels, or oxygenation index. CONCLUSIONS: Cimetidine may reduce surgical stress and augment the immune system after cardiac surgery with cardiopulmonary bypass.


Assuntos
Ponte Cardiopulmonar , Cimetidina/administração & dosagem , Ponte de Artéria Coronária , Complicações Pós-Operatórias/prevenção & controle , Síndrome de Resposta Inflamatória Sistêmica/prevenção & controle , Idoso , Proteína C-Reativa/metabolismo , Cimetidina/efeitos adversos , Relação Dose-Resposta a Droga , Feminino , Humanos , Interleucina-6/sangue , Interleucina-8/antagonistas & inibidores , Interleucina-8/sangue , Contagem de Leucócitos , Elastase de Leucócito/antagonistas & inibidores , Elastase de Leucócito/sangue , Contagem de Linfócitos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/imunologia , Síndrome de Resposta Inflamatória Sistêmica/imunologia
7.
Ann Thorac Surg ; 71(6): 1931-8, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11426771

RESUMO

BACKGROUND: To evaluate the effects of colforsin daropate hydrochloride (colforsin), a water-soluble forskolin derivative, on hemodynamics and systemic inflammatory response after cardiopulmonary bypass, we conducted a prospective randomized study. METHODS: Twenty-nine patients undergoing coronary artery bypass grafting were randomized to receive either colforsin treatment (colforsin; n = 14) or no colforsin treatment (control; n = 15). Administration of colforsin (0.5 microg.kg(-1).min(-1)) was started after induction of anesthesia and was continued for 6 hours. Perioperative cytokine and cyclic adenosine monophosphate levels, hemodynamics, and respiratory function were measured serially. RESULTS: Marked positive inotropic and vasodilatory effects were observed in patients receiving colforsin. Interleukin 1beta, interleukin 6, and interleukin 8 levels after cardiopulmonary bypass were significantly (p < 0.05) lower in the colforsin group. Plasma levels of cyclic adenosine monophosphate increased significantly (p < 0.05) in the colforsin group, and the levels correlated inversely (r = -0.56, p = 0.002) with the respiratory index after cardiopulmonary bypass. CONCLUSIONS: Intraoperative administration of colforsin daropate hydrochloride had potent inotropic and vasodilatory activity and attenuated cytokine production and respiratory dysfunction after cardiopulmonary bypass. The results indicate that the technique can be a novel therapeutic strategy for the systemic inflammatory response associated with cardiopulmonary bypass.


Assuntos
Cardiotônicos/administração & dosagem , Colforsina/análogos & derivados , Colforsina/administração & dosagem , Ponte de Artéria Coronária , Complicações Pós-Operatórias/tratamento farmacológico , Pré-Medicação , Síndrome de Resposta Inflamatória Sistêmica/tratamento farmacológico , Idoso , Ponte Cardiopulmonar , Cardiotônicos/efeitos adversos , Colforsina/efeitos adversos , Feminino , Humanos , Interleucina-1/sangue , Interleucina-6/sangue , Interleucina-8/sangue , Masculino , Pessoa de Meia-Idade , Contração Miocárdica/efeitos dos fármacos , Complicações Pós-Operatórias/imunologia , Estudos Prospectivos , Síndrome de Resposta Inflamatória Sistêmica/imunologia , Vasodilatação/efeitos dos fármacos
8.
J Heart Valve Dis ; 10(3): 367-70, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11380100

RESUMO

BACKGROUND AND AIM OF THE STUDY: Aortic prosthetic valve endocarditis (PVE) with annular destruction presents a challenge that requires techniques to eradicate the infection and correct the hemodynamic abnormality. METHODS: Between July 1, 1996 and March 31, 2000, six patients with native or PVE of the aortic valve and aortic annular destruction underwent surgical treatment. Of these patients, three (two men, one woman; mean age 71.0 years) had circumferential annular destruction of the aortic annulus, and formed the basis of this study. The microorganisms responsible for the infection were Streptococcus spp. in two patients and Staphylococcus aureus in one patient. In addition to aggressive debridement of the infected tissue, repair was achieved by reconstruction of the left ventricular outflow tract with a xenopericardial conduit and fixation of the new prosthetic valve to the conduit. RESULTS: One patient with ventricular septal perforation, multiple systemic embolism and sepsis died of low cardiac output syndrome soon after surgery. Two operative survivors were followed up for 9 and 51 months, with no late deaths. No patient has experienced recurrent infection, pericardial patch aneurysm, or prosthetic valve detachment. CONCLUSION: These operative procedures provide easy and secure fixation of the pericardial patch to the healthy tissue under excellent operative view, as well as a sturdy structure for the fixation of the new prosthesis, and complete exclusion of the abscess cavity from the blood stream.


Assuntos
Doenças da Aorta/etiologia , Doenças da Aorta/cirurgia , Valva Aórtica/cirurgia , Endocardite/etiologia , Endocardite/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Pericárdio/transplante , Infecções Relacionadas à Prótese/cirurgia , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/cirurgia , Idoso , Anastomose Cirúrgica , Doenças da Aorta/fisiopatologia , Valva Aórtica/fisiopatologia , Endocardite/fisiopatologia , Feminino , Humanos , Masculino , Infecções Relacionadas à Prótese/fisiopatologia , Transplante Heterólogo , Disfunção Ventricular Esquerda/fisiopatologia
9.
J Heart Valve Dis ; 9(3): 408-14, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10888099

RESUMO

BACKGROUND AND AIM OF THE STUDY: We have reported clinical findings that normally functioning open pivot ATS valves did not open completely. In order to analyze features of the ATS valve motion more precisely, in vitro tests were conducted. METHODS: Opening angles and pressure gradients of the ATS valve were measured and compared with those of the St. Jude Medical (SJM) valve under steady flow, but with various outlet configurations. Second, opening angles of the two valves were measured under pulsatile conditions in two different outflow configurations: (i) a 'straight outlet' where the leaflets did not extend into the tapering outflow chamber, and (ii) an 'abrupt enlargement outlet' where the leaflets extended directly into the enlarged outflow space. Third, flow visualization studies were made under steady flow conditions in the straight and abrupt enlargement outlet conduits, respectively. RESULTS: Under steady flow conditions, opening of the ATS valve was restricted in most outflow configurations; only when the outlet angle was 0 degrees did the valve open fully. The SJM valve opened completely in all downstream configurations. Despite restricted opening in the ATS valve, the pressure gradient was similar in both valves. Under pulsatile conditions, both valves opened fully in the straight outlet; however, in the abrupt enlargement outlet the ATS valve opened incompletely and the SJM valve completely. Substantial turbulent flow was observed at the outside of the leaflet and corners of the conduit, notably with the ATS valve. CONCLUSION: This study showed that the ATS valve did not open fully except when the outflow was straight, and the leaflet did not extend into an enlarged downstream chamber. Structural features of the ATS, such as its axis being located close to the straight edge and its leaflets extending further downstream from the ring orifice, may cause this unique valve behavior.


Assuntos
Próteses Valvulares Cardíacas , Humanos , Técnicas In Vitro , Movimento (Física) , Desenho de Prótese , Fluxo Pulsátil
10.
Eur J Cardiothorac Surg ; 18(5): 565-9, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11053818

RESUMO

OBJECTIVE: The choice of the valve substitute in the tricuspid position remains controversial. A St. Jude Medical valve is a choice of valve substitute and its lower thrombogenicity and excellent hemodynamic performance have been reported even in the tricuspid position. However, little is known of the long-term durability of the St. Jude Medical valve in the tricuspid position. Our long-term experience of tricuspid valve replacement showed the higher thrombogenicity than we had expected, therefore, this study was done to reconsider our strategy for valve choice. METHODS: This study reviewed 23 patient who underwent 25 tricuspid valve replacements with the St. Jude Medical valves from 1980 to 1997. The mean age was 40 years. Eleven patients (48%) were men. There were four in-hospital deaths (17%). The remaining 19 patients were all alive and followed from 2.2 to 19.0 years (mean 11.8 years). RESULTS: The overall survival, including hospital mortality, was 83%, 10 and 15 years after surgery. Valve thrombosis occurred in six patients. Freedom from valve thrombosis was 78 and 70%, 10 and 15 years after surgery, respectively. The linearized rate of the valve thrombosis was 2.9%/patient-years. Six patients required reoperation. The mean interval to reoperation was 9.5 years. Freedom from reoperation was 83% and 75%, 10 and 15 years after surgery, respectively. The linearized rate of the reoperation was 2.8%/patient-years. No structural valve deterioration was found. Echocardiographic study showed that the function of the St. Jude Medical valve without valve-related complications was well maintained. CONCLUSIONS: The higher thrombogenicity of the St. Jude Medical valve in the tricuspid position altered our choice of valve substitutes from the St. Jude Medical valve to a bioprosthesis which is lack of need for anticoagulant therapy except for juvenile patients who are able to maintain potent anticoagulant therapy.


Assuntos
Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Insuficiência da Valva Tricúspide/cirurgia , Estenose da Valva Tricúspide/cirurgia , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Ecocardiografia , Feminino , Seguimentos , Cardiopatias/etiologia , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Mortalidade Hospitalar , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Reoperação , Análise de Sobrevida , Trombose/etiologia , Resultado do Tratamento , Insuficiência da Valva Tricúspide/classificação , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/mortalidade , Insuficiência da Valva Tricúspide/fisiopatologia , Estenose da Valva Tricúspide/classificação , Estenose da Valva Tricúspide/diagnóstico , Estenose da Valva Tricúspide/mortalidade , Estenose da Valva Tricúspide/fisiopatologia
11.
J Cardiovasc Surg (Torino) ; 43(5): 581-7, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12386567

RESUMO

BACKGROUND: We reviewed our clinical experience with primary cardiac tumors, attempting to clarify the surgical management of these rare entities. METHODS: Between October 1978 and November 1999, we experienced 60 surgical cases of primary cardiac tumors. There were 23 male and 37 female patients (age range, 7 months to 84 years). Tumors included the following 3 groups: myxomas (n=49), nonmyxoma benign tumors (n=3), and malignant tumors (n=8). We reviewed the presenting symptoms, diagnostic data, anatomical findings, and surgical techniques, and evaluated the surgical RESULTS. Late follow-up was 95% complete (mean follow-up, 7.7+/-7.1 years). RESULTS: Tumors produced obstructive, embolic, and/or constitutional symptoms in most cases. Generally, echocardiography alone gave sufficient information for operation. Full-thickness excision was performed in 42 patients with myxoma. Complete excision was achieved in all of the nonmyxoma benign tumors and in none of the malignancies. Early mortalities in the 3 groups were 8.2% (4/49), 0% (0/3), and 12.5% (1/8), respectively. Late mortalities were 9.5% (4/42), 0% (0/3), and 100% (7/7), respectively. One patient with myxoma had recurrence, the cause of which was likely to be inadequate resection. The late deaths in patients with malignancies were due to metastasis or local recurrence. CONCLUSIONS: Benign tumors are generally curable if surgically excised. Preoperative refractory cardiac dysfunction or embolism should be avoided by the accurate evaluation on echocardiography. The prognosis of malignant tumors is poor if they are only debulked. However, aggressive surgery that can palliate obstruction and allow time for adjuvant therapy should be carried out.


Assuntos
Neoplasias Cardíacas/cirurgia , Mixoma/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos , Feminino , Neoplasias Cardíacas/diagnóstico por imagem , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Mixoma/diagnóstico por imagem , Estudos Retrospectivos , Rabdomiossarcoma/diagnóstico por imagem , Rabdomiossarcoma/cirurgia , Resultado do Tratamento , Ultrassonografia
12.
J Cardiovasc Surg (Torino) ; 42(6): 735-40, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11698938

RESUMO

BACKGROUND: Serum heart fatty acid-binding protein (H-FABP) has been reported to be a sensitive and early indicator of myocardial damage. However, circulating H-FABP may be cleared considerably from kidney, similar to that found for myoglobin. Therefore, the possibility exists that any change in renal function affects serum H-FABP concentration, and thus leads to erroneous interpretation. To evaluate the influence of renal function on H-FABP levels, we conducted a prospective study. METHODS: Nineteen patients undergoing isolated primary coronary artery bypass grafting were enrolled in this study. The patients were classified by the preoperative creatinine clearance into two groups: the control group (n=12); patients with creatinine clearance of 40 mL/min or greater, and the renal dysfunction group (n=7); patients with creatinine clearance of less than 40 mL/min. Serum H-FABP, CK-MB, troponin-T and urinary H-FABP levels were measured perioperatively. RESULTS: None of the patients had perioperative myocardial infarction. No significant differences were found in CK-MB and troponin-T levels between the groups. The renal dysfunction group resulted in significantly (p<0.05) higher serum H-FABP levels and lower urinary H-FABP levels than those in the control group, postoperatively. The creatinine clearance correlated inversely with the peak levels of serum H-FABP (r=-0.75, p=0.0001) and correlated with the peak levels of urinary H-FABP (r=0.64, p=0.003). CONCLUSIONS: The results indicate that the kidneys play an important role in the clearance of serum H-FABP. Thus, caution must be taken in interpreting this marker for myocardial damage during cardiac surgery in patients with renal dysfunction.


Assuntos
Proteínas de Transporte/sangue , Proteínas de Transporte/urina , Ponte de Artéria Coronária , Ácidos Graxos/sangue , Ácidos Graxos/urina , Nefropatias/fisiopatologia , Proteínas de Neoplasias , Proteínas Supressoras de Tumor , Idoso , Biomarcadores/sangue , Biomarcadores/urina , Estudos de Casos e Controles , Creatina Quinase/sangue , Creatina Quinase Forma MB , Creatinina/sangue , Proteína 7 de Ligação a Ácidos Graxos , Proteínas de Ligação a Ácido Graxo , Feminino , Humanos , Cuidados Intraoperatórios , Isoenzimas/sangue , Nefropatias/sangue , Nefropatias/urina , Testes de Função Renal , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Troponina T/sangue
13.
ASAIO J ; 43(5): M706-10, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9360138

RESUMO

Platelet adhesion on an oxygenator membrane is associated with thrombocytopenia or thrombus formation during extracorporeal circulation. The authors evaluated protein adsorption and platelet adhesion on three oxygenator hollow fiber membranes fabricated with polypropylene, silicone, and double layer polyolefin. Adsorbed proteins were analyzed by bicinchoninic acid protein assay, sodium dodecyl sulfate polyacrylamide gel electrophoresis, and Western blot. Platelet adhesion was assessed with enzyme immunoassays using monoclonal antibodies directed against CD42b and CD61. After 3 hr of incubation at 37 degrees C in whole blood, the amount of adsorbed protein was the least on silicone and increased from silicone < double polyolefin < polypropylene. The adsorbed protein pattern was similar; however, silicone showed less adsorption for all protein bands, and the gamma chain of fibrinogen was not detected. In contrast, double polyolefin showed the highest fibrinogen adsorption. The optical density at a wavelength of 450 nm for CD42b was 1.47 +/- 0.35 in polypropylene, 1.16 +/- 0.38 in silicone, and 1.85 +/- 0.19 in double polyolefin (p < 0.01 vs silicone) and for CD61 0.98 +/- 0.39 in polypropylene, 0.91 +/- 0.22 in silicone, and 1.69 +/- 0.25 in double polyolefin (p < 0.01 vs silicone and polypropylene). These data suggest that silicone is advantageous for long term extracorporeal respiratory support in terms of less platelet adhesion and no plasma leakage through the pores.


Assuntos
Proteínas Sanguíneas/farmacocinética , Oxigenadores de Membrana/efeitos adversos , Adesividade Plaquetária , Adsorção , Estudos de Avaliação como Assunto , Fibrinogênio/farmacocinética , Fibronectinas/farmacocinética , Humanos , Técnicas In Vitro , Membranas Artificiais , Ativação Plaquetária , Polienos , Polipropilenos , Albumina Sérica/farmacocinética , Silicones , Propriedades de Superfície , Fator de von Willebrand/farmacocinética
14.
ASAIO J ; 44(3): 207-11, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-9617953

RESUMO

A totally implantable centrifugal artificial heart has been developed using a miniaturized pivot bearing supported centrifugal pump (Gyro PI pump). The authors report current progress in its development. The Gyro PI-601 has a priming volume of 20 ml, weighs 100 g, has a height of 60 mm, and has a diameter of 65 mm. This pump can provide 8 L/min against 150 mmHg at 2,250 rpm. It is driven by an miniaturized DC brushless motor with the coils fixed in a plastic mold that is waterproof and made of titanium (weight, 204 g; height, 18 mm; diameter, 65 mm). In this centrifugal artificial heart, two Gyro PI pumps are implanted independently to replace cardiac function without resecting the native heart. Its anatomic and surgical feasibility were confirmed experimentally. The Gyro PI-601 was implanted as a right or left ventricular assist device in the preperitoneal space of five calves. All five tests proceeded without any thromboembolic symptoms. One of five tests was extended more than 1 month to confirm the long-term feasibility of the Gyro PI-601 pump system. Based on the satisfactory results of the in vivo tests, the material conversion of the Gyro PI from polycarbonate to titanium alloy (Ti-6A1-4V) was undertaken to improve its biocompatibility for long-term implantation.


Assuntos
Centrifugação/instrumentação , Coração Artificial/tendências , Tromboembolia/prevenção & controle , Ligas , Animais , Materiais Biocompatíveis , Velocidade do Fluxo Sanguíneo , Bovinos , Estudos de Viabilidade , Coração Auxiliar , Humanos , Titânio
15.
Ann Thorac Cardiovasc Surg ; 4(2): 87-90, 1998 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9577004

RESUMO

A 63-year-old woman with a prosthetic mitral valve who developed valve thrombosis after abdominal surgical procedures is reported. She had undergone mitral valve replacement with a Sorin-Bicarbon valve 3 years previously, and was referred for an operation due to rectal cancer with anal bleeding. On admission, the patient was on oral anticoagulant therapy with warfarin, and the intensity of anticoagulation was around 40% of Thrombotest. Doppler echocardiography showed that the prosthetic mitral valve function was normal. Low anterior resection of the rectum was uneventful. Management of the perioperative anticoagulation was peformed with heparin, however, the postoperative anticoagulation using intravenous infusion of heparin was imperfectly achieved. Consequently, thrombosis of the prosthetic mitral valve occurred 8 days after the operation. Replacement of the thrombosed prosthetic valve was performed with successful results. The imperfect postoperative anticoagulation with heparin may have been the cause of the valve thrombosis. The management of perioperative anticoagulation during noncardiac operations is discussed.


Assuntos
Abdome/cirurgia , Próteses Valvulares Cardíacas , Falha de Prótese , Tromboembolia/etiologia , Anticoagulantes/uso terapêutico , Ecocardiografia Doppler em Cores , Feminino , Seguimentos , Doenças das Valvas Cardíacas/cirurgia , Humanos , Pessoa de Meia-Idade , Valva Mitral , Neoplasias Retais/cirurgia , Reoperação , Tromboembolia/diagnóstico por imagem , Tromboembolia/terapia , Terapia Trombolítica
16.
Ann Thorac Cardiovasc Surg ; 6(2): 130-3, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10870010

RESUMO

A case of a 65-year-old woman who had a quadricuspid aortic valve associated with aortic regurgitation is reported. The patient had severe aortic regurgitation and four equally divided aortic cusps. The valve abnormality was detected by a transesophageal echo and an aortography. The incomplete aortic valve was excised and replaced by a St. Jude Medical prosthesis. Although this case had no coronary abnormality, a coronary displacement is often reported in quadricuspid aortic valve cases. In order to perform an operation safely, accurate information which is obtained by a non-invasive examination of the transesoph-ageal echo is quite valuable as it can indicate the need for further preoperative examinations of the coronary arteries.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Implante de Prótese de Valva Cardíaca , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/congênito , Insuficiência da Valva Aórtica/diagnóstico , Aortografia , Angiografia Coronária , Diagnóstico Diferencial , Ecocardiografia Transesofagiana , Feminino , Humanos
17.
Ann Thorac Cardiovasc Surg ; 6(1): 27-33, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10748356

RESUMO

OBJECTIVES: Effects of supplemental L-arginine, nitric oxide precursor, during warm blood cardioplegia were assessed in the blood perfused isolated rat heart. METHODS: The isolated hearts were perfused with blood at 37 degrees C from a support rat. After 20 minutes of aerobic perfusion, the hearts were arrested for 60 minutes with warm blood cardioplegia given at 20-minute intervals. This was followed by 60 minutes of reperfusion. The hearts were divided into the following three groups according to the supplemental drugs added to the cardioplegic solution. The control group (n = 10) received standard warm blood cardioplegia. The L-ARG group (n = 10) received warm blood cardioplegia supplemented with L-arginine (3 mmol/l). The L-NAME group (n = 10) received warm blood cardioplegia supplemented with L-arginine (3 mmol/l) and L-nitro-arginine methyl ester, a competitive inhibitor of nitric oxide synthase (1 mmol/l). After 60 minutes of cardioplegic arrest, cardiac function, myocardial metabolism and myocardial release of circulating adhesion molecules were measured during reperfusion. RESULTS: Left ventricular end-diastolic pressure was significantly lower (p<0.05) in the L-ARG group than in the control group and the L-NAME group during reperfusion. Isovolumic left ventricular developed pressure, dp/dt and coronary blood flow were significantly greater (p< 0.05) in the L-ARG group during reperfusion. The L-ARG group resulted in early recovery of lactate metabolism during reperfusion. Myocardial release of circulating intercellular adhesion molecule-1 (ICAM-1) and E-selectin were significantly less (p<0.05) in the L-ARG group at 15 minutes of reperfusion. CONCLUSIONS: The results suggest that augmented nitric oxide by adding L-arginine to warm blood cardioplegia can preserve left ventricular function and ameliorate endothelial inflammation. The technique can be a novel cardioprotective strategy in patients undergoing cardiac surgery.


Assuntos
Arginina , Soluções Cardioplégicas , Parada Cardíaca Induzida , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Animais , Sangue , Creatina Quinase/metabolismo , Selectina E/metabolismo , Inibidores Enzimáticos , Molécula 1 de Adesão Intercelular/metabolismo , Isoenzimas , Ácido Láctico/metabolismo , Reperfusão Miocárdica , Miocárdio/metabolismo , NG-Nitroarginina Metil Éster , Óxido Nítrico , Perfusão , Ratos , Ratos Wistar , Fatores de Tempo , Função Ventricular Esquerda/fisiologia
18.
Kurume Med J ; 47(1): 91-4, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10812895

RESUMO

A 33-year-old male with sick sinus syndrome, who had received a pacemaker implant 18 years earlier, was complicated with a generator infection. Although the infected generator was removed, he was suffered from the recurrent local infection associated with a retained pacemaker lead. After a new pacemaker system implantation from the other side of the subclavian vein, we attempted to remove the lead utilizing a pacemaker removal kit. However, this intervention procedure was unsuccessful, because fibrous adhesions had developed around the lead, accompanied by calcification along its course. As a last resort, we opened the heart under extracorporeal circulation and removed the lead under direct vision. The post-operative course was uneventful. In order to remove a long-term implanted pacemaker lead, the direct surgical procedure with extracorporeal circulation is a favorable mean alternative to conventional intervention techniques.


Assuntos
Infecções Bacterianas/terapia , Marca-Passo Artificial/efeitos adversos , Adulto , Procedimentos Cirúrgicos Cardíacos , Circulação Extracorpórea , Humanos , Masculino
19.
Jpn J Thorac Cardiovasc Surg ; 49(1): 47-52, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11233242

RESUMO

OBJECTIVE: Aging of the population is a current phenomenon in Japan, and life expectancy at 80 years old is getting longer. So we reviewed cardio-aortic operations on octogenarians at our institution. SUBJECTS AND METHODS: Thirty-three consecutive octogenarian patients who had undergone cardio-aortic operations from 1992 to 1998 were studied. There were 14 men and 19 women. The mean age was 81.9 years. Of the 33, 19 patients (58%) were in New York Heart Association class IV, and 21 patients (64%) were operated on urgently or in emergency. The procedures undergone were operation for coronary artery disease in 17 patients, operation for valvular disease in 7 patients, operation for thoracic-aorta in 7 patients, and others in 2 patients. RESULTS: The hospital mortality rate was 27% (9 patients). However, 89% of patients experiencing hospital death were in New York Heart Association class IV preoperatively and had required an emergency/urgent operation. On the other hand, there was only one hospital death (1/12, 8.3%) among the elective patients. The statistically significant risk factors for hospital death were renal insufficiency, shock, New York Heart Association class IV, intra-aortic balloon pumping, and longer cardiopulmonary bypass time. The one-, three-, and five-year-survival rate was 73%, 68%, and 55%, respectively. Of the survivors, 77% were in class I or II. CONCLUSION: Although octogenarians' hospital mortality was still very high, the mid-term results were acceptable and the survivors' quality of life was satisfactory. These data suggested that we should operate on cardio-aortic patients before they reach a very serious state, especially in octogenarians.


Assuntos
Cardiopatias/cirurgia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Feminino , Cardiopatias/mortalidade , Mortalidade Hospitalar , Humanos , Japão , Masculino , Qualidade de Vida , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento
20.
Kyobu Geka ; 46(3): 263-5, 1993 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-8468844

RESUMO

A seventeen-year-old male with Bland-White-Garland syndrome underwent direct implantation of the left coronary artery to the ascending aorta. Under cardiopulmonary bypass, the main pulmonary artery was completely transected and the left coronary artery (LCA) was excised with a cuff of the pulmonary artery wall. Then the proximal end of LCA was directly anastomosed to the ascending aorta. The postoperative course was excellent. It appears that this surgical procedure might be the most ideal repair both anatomically and hemodynamically to reconstruct the left coronary artery in Bland-White-Garland syndrome.


Assuntos
Ponte de Artéria Coronária/métodos , Anomalias dos Vasos Coronários/cirurgia , Artéria Pulmonar/anormalidades , Adolescente , Aorta/cirurgia , Ponte Cardiopulmonar , Humanos , Masculino , Artéria Pulmonar/cirurgia , Síndrome
SELEÇÃO DE REFERÊNCIAS