Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 98
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 25(3): 863-872, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36576323

RESUMO

AIMS: There is rising healthcare utilization related to the increasing incidence and prevalence of atrial fibrillation (AF) worldwide. Simplifying therapy and reducing hospital episodes would be a valuable development. The efficacy of a streamlined AF ablation approach was compared to drug therapy and a conventional catheter ablation technique for symptom control in paroxysmal AF. METHODS AND RESULTS: We recruited 321 patients with symptomatic paroxysmal AF to a prospective randomized, multi-centre, open label trial at 13 UK hospitals. Patients were randomized 1:1:1 to cryo-balloon ablation without electrical mapping with patients discharged same day [Ablation Versus Anti-arrhythmic Therapy for Reducing All Hospital Episodes from Recurrent (AVATAR) protocol]; optimization of drug therapy; or cryo-balloon ablation with confirmation of pulmonary vein isolation and overnight hospitalization. The primary endpoint was time to any hospital episode related to treatment for atrial arrhythmia. Secondary endpoints included complications of treatment and quality-of-life measures. The hazard ratio (HR) for a primary endpoint event occurring when comparing AVATAR protocol arm to drug therapy was 0.156 (95% CI, 0.097-0.250; P < 0.0001 by Cox regression). Twenty-three patients (21%) recorded an endpoint event in the AVATAR arm compared to 76 patients (74%) within the drug therapy arm. Comparing AVATAR and conventional ablation arms resulted in a non-significant HR of 1.173 (95% CI, 0.639-2.154; P = 0.61 by Cox regression) with 23 patients (21%) and 19 patients (18%), respectively, recording primary endpoint events (P = 0.61 by log-rank test). CONCLUSION: The AVATAR protocol was superior to drug therapy for avoiding hospital episodes related to AF treatment, but conventional cryoablation was not superior to the AVATAR protocol. This could have wide-ranging implications on how demand for AF symptom control is met. TRIAL REGISTRATION: Clinical Trials Registration: NCT02459574.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Antiarrítmicos/efeitos adversos , Resultado do Tratamento , Estudos Prospectivos , Hospitais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
2.
Indian Pacing Electrophysiol J ; 22(1): 54-57, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34775047

RESUMO

Anti-tachycardia pacing (ATP) is frequently used to terminate ventricular tachycardia (VT), however it is not always successful and may accelerate VT requiring defibrillation. REVRAMP is a novel concept of ATP that involves delivering pacing at a faster rate than VT, but instead of abruptly terminating pacing after eight beats, pacing is gradually slowed until VT continues or normal rhythm is restored. In a pilot study we show that REVRAMP can restore normal rhythm, and that if REVRAMP is unsuccessful, VT is not accelerated.

3.
Postgrad Med J ; 97(1149): 452-458, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33122341

RESUMO

Many drug therapies are associated with prolongation of the QT interval. This may increase the risk of Torsades de Pointes (TdP), a potentially life-threatening cardiac arrhythmia. As the QT interval varies with a change in heart rate, various formulae can adjust for this, producing a 'corrected QT' (QTc) value. Normal QTc intervals are typically <450 ms for men and <460 ms for women. For every 10 ms increase, there is a ~5% increase in the risk of arrhythmic events. When prescribing drugs associated with QT prolongation, three key factors should be considered: patient-related risk factors (eg, female sex, age >65 years, uncorrected electrolyte disturbances); the potential risk and degree of QT prolongation associated with the proposed drug; and co-prescribed medicines that could increase the risk of QT prolongation. To support clinicians, who are likely to prescribe such medicines in their daily practice, we developed a simple algorithm to help guide clinical management in patients who are at risk of QT prolongation/TdP, those exposed to QT-prolonging medication or have QT prolongation.


Assuntos
Síndrome do QT Longo , Administração dos Cuidados ao Paciente/métodos , Risco Ajustado/métodos , Torsades de Pointes/prevenção & controle , Humanos , Síndrome do QT Longo/induzido quimicamente , Síndrome do QT Longo/terapia , Padrões de Prática Médica
4.
J Cardiovasc Magn Reson ; 22(1): 13, 2020 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-32036784

RESUMO

BACKGROUND: Using cardiovascular magnetic resonance imaging (CMR), it is possible to detect diffuse fibrosis of the left ventricle (LV) in patients with atrial fibrillation (AF), which may be independently associated with recurrence of AF after ablation. By conducting CMR, clinical, electrophysiology and biomarker assessment we planned to investigate LV myocardial fibrosis in patients undergoing AF ablation. METHODS: LV fibrosis was assessed by T1 mapping in 31 patients undergoing percutaneous ablation for AF. Galectin-3, coronary sinus type I collagen C terminal telopeptide (ICTP), and type III procollagen N terminal peptide were measured with ELISA. Comparison was made between groups above and below the median for LV extracellular volume fraction (ECV), followed by regression analysis. RESULTS: On linear regression analysis LV ECV had significant associations with invasive left atrial pressure (Beta 0.49, P = 0.008) and coronary sinus ICTP (Beta 0.75, P < 0.001), which remained significant on multivariable regression. CONCLUSION: LV fibrosis in patients with AF is associated with left atrial pressure and invasively measured levels of ICTP turnover biomarker.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Função Ventricular Esquerda , Remodelação Ventricular , Adulto , Idoso , Fibrilação Atrial/sangue , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Pressão Atrial , Biomarcadores/sangue , Proteínas Sanguíneas , Ablação por Cateter , Colágeno Tipo I/sangue , Técnicas Eletrofisiológicas Cardíacas , Feminino , Fibrose , Galectina 3/sangue , Galectinas , Ventrículos do Coração/metabolismo , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Fragmentos de Peptídeos/sangue , Peptídeos/sangue , Valor Preditivo dos Testes , Pró-Colágeno/sangue
5.
Europace ; 22(3): 375-381, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31808520

RESUMO

AIMS: Although cryoballoon pulmonary vein isolation is a well-established treatment for paroxysmal atrial fibrillation (AF), it's role in persistent AF is unclear. We examined procedural success and long-term outcomes of cryoablation in persistent and longstanding persistent AF. METHODS AND RESULTS: International multicentre registry from three UK and eight European centres. Consecutive patients undergoing cryoablation for persistent AF included. Procedural data, complications, and follow-up were prospectively recorded. Patients were followed-up at 3, 6, and 12 months with an electrocardiogram with open access to arrhythmia nurses thereafter. Ambulatory monitoring was dictated by symptoms. Success was defined as freedom from AF or atrial tachycardia lasting >30 s off antiarrhythmic drugs (AADs). Six hundred and nine consecutive cryoablation procedures. Mean procedure and fluoroscopy times were 95 ± 65 and 13 ± 10 min. Single procedure success rates were 368/602 (61%) off AADs over a median of 2.4 (1.0-4.0) years. Arrhythmia-free survival off AADs was 64% and 57% for persistent and longstanding persistent AF at 24 months of follow-up (P = 0.02). Rate of repeat ablations was 20% in persistent and 32% in longstanding persistent AF (P = 0.006). Cox regression analyses showed a significant association between duration of AF and left atrial diameter and arrhythmia recurrence [hazard ratio (HR) 1.05, P-value 0.01 and HR 1.02, P-value 0.004]. CONCLUSION: Cryoablation for persistent AF is safe, fast and has good outcomes at long-term follow-up. Cryoablation is reasonable as a first line option for these patients. Short procedure times may help increase capacity of cardiac units to meet the rising demand for AF ablation. Randomised control trials are needed to compare outcomes with different techniques.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Resultado do Tratamento
6.
Am Heart J ; 214: 36-45, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31152874

RESUMO

Atrial Fibrillation (AF) ablation using the cryoballoon is effective at reducing symptomatic AF episodes. The prevalence of AF is increasing with the aging population and access to such treatment would be enhanced by reducing the resource requirements. Relinquishing electrical mapping of the pulmonary veins (PV) removes the need for PV catheters, electrical recording equipment and staff trained in using this equipment. Moreover, the majority of complications are peri-procedural so overnight hospitalization maybe unnecessary. We tested this streamlined approach to AF ablation against medical therapy using the endpoint of time to all hospital episodes. METHODS: The AVATAR-AF study is a prospective, multicenter, randomized controlled trial testing the primary hypothesis that AF ablation done without PV mapping or overnight hospitalization is more effective than anti-arrhythmic drugs at reducing all hospital episodes related to recurrent atrial arrhythmias. We included a third arm to test a secondary hypothesis that confirming PV entrance block as per consensus guidelines can improve outcomes. Three hundred twenty-one patients with documented paroxysmal AF will be randomized in a 1:1:1 manner to one of three investigation arms: (1) AVATAR protocol cryoballoon ablation without assessment of acute PV isolation or overnight hospitalization; (2) medical therapy with anti-arrhythmic drugs; or (3) conventional cryoballoon ablation with assessment of acute PV isolation. The primary endpoint is defined as the time to all hospital episodes (including outpatient consultation) related to treatment for atrial arrhythmia. CONCLUSION: The AVATAR-AF study will determine whether the resource utilization for AF ablation can be reduced whilst maintaining superiority over medical therapy.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial , Ablação por Cateter/métodos , Criocirurgia/métodos , Hospitalização , Veias Pulmonares/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto , Procedimentos Cirúrgicos Ambulatórios/métodos , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Estudos Cross-Over , Fenômenos Eletrofisiológicos , Humanos , Estudos Multicêntricos como Assunto , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Avaliação de Sintomas , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 29(12): 1624-1634, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30168232

RESUMO

INTRODUCTION: The ganglionated plexuses (GPs) of the intrinsic cardiac autonomic system are implicated in arrhythmogenesis. GP localization by stimulation of the epicardial fat pads to produce atrioventricular dissociating (AVD) effects is well described. We determined the anatomical distribution of the left atrial GPs that influence atrioventricular (AV) dissociation. METHODS AND RESULTS: High frequency stimulation was delivered through a Smart-Touch catheter in the left atrium of patients undergoing atrial fibrillation (AF) ablation. Three dimensional locations of points tested throughout the entire chamber were recorded on the CARTO™ system. Impact on the AV conduction was categorized as ventricular asystole, bradycardia, or no effect. CARTO maps were exported, registered, and transformed onto a reference left atrial geometry using a custom software, enabling data from multiple patients to be overlaid. In 28 patients, 2108 locations were tested and 283 sites (13%) demonstrated (AVD-GP) effects. There were 10 AVD-GPs (interquartile range, 11.5) per patient. Eighty percent (226) produced asystole and 20% (57) showed bradycardia. The distribution of the two groups was very similar. Highest probability of AVD-GPs (>20%) was identified in: inferoseptal portion (41%) and right inferior pulmonary vein base (30%) of the posterior wall, right superior pulmonary vein antrum (31%). CONCLUSION: It is feasible to map the entire left atrium for AVD-GPs before AF ablation. Aggregated data from multiple patients, producing a distribution probability atlas of AVD-GPs, identified three regions with a higher likelihood for finding AVD-GPs and these matched the histological descriptions. This approach could be used to better characterize the autonomic network.


Assuntos
Atlas como Assunto , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Gânglios Autônomos/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Imageamento Tridimensional/métodos , Idoso , Ablação por Cateter/métodos , Feminino , Gânglios Autônomos/anatomia & histologia , Átrios do Coração/anatomia & histologia , Humanos , Masculino , Pessoa de Meia-Idade , Probabilidade
8.
Catheter Cardiovasc Interv ; 92(2): 269-273, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29044976

RESUMO

BACKGROUND: The assessment of myocardial viability is crucial before percutaneous coronary intervention (PCI) is carried out to ensure that the patient will gain benefit. Trans-coronary pacing (TCP) has previously been used to pace myocardium but may also provide information on myocardial viability. METHODS: Patients with a single, significant coronary stenosis requiring PCI were recruited. They underwent a cardiac MRI to assess myocardial viability. Prior to PCI, a coronary guidewire was used to measure pacing threshold, impedance, and R-wave amplitude in different myocardial segments to determine any association between the electrical parameters and myocardial viability. RESULTS: Eight patients were recruited and six patients underwent intervention. Pacing sensitivity did not demonstrate statistically significant differences between normal and scarred myocardium. Impedance demonstrated a mean of 304.8 ± 74.0 Ω in normal myocardium (NM), 244.1 ± 66.6 Ω in <50% myocardial scar (MS), and 222.3 ± 33.8 Ω in ≥50% MS. Pacing threshold demonstrated a mean of 1.960 ± 1.226 V in NM, 5.009 ± 2.773 V in <50% MS, and 3.950 ± 0.883 V in ≥50% MS. For both impedance and threshold, there was a significant difference among the groups (P = 0.12 and P = 0.002, respectively), and post hoc Tukey's pairwise comparison demonstrated significant differences between NM and scarred myocardium. No significant differences were found between <50% MS and ≥50% MS. CONCLUSIONS: Impedance and pacing threshold, measured during TCP, can be used to differentiate between normal myocardium and scarred myocardium. Further research is needed to determine whether TCP can discriminate between viable and nonviable myocardium.


Assuntos
Estimulação Cardíaca Artificial , Doença da Artéria Coronariana/diagnóstico , Estenose Coronária/diagnóstico , Técnicas Eletrofisiológicas Cardíacas , Miocárdio/patologia , Adulto , Idoso , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia , Estenose Coronária/patologia , Estenose Coronária/cirurgia , Impedância Elétrica , Estudos de Viabilidade , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Sobrevivência de Tecidos
9.
Europace ; 20(FI1): f13-f19, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29016773

RESUMO

Aims: The identification of arrhythmogenic right ventricular dysplasia (ARVD) from 12-channel standard electrocardiogram (ECG) is challenging. High density ECG data may identify lead locations and criteria with a higher sensitivity. Methods and results: Eighty-channel ECG recording from patients diagnosed with ARVD and controls were quantified by magnitude and integral measures of QRS and T waves and by a measure (the average silhouette width) of differences in the shapes of the normalized ECG cycles. The channels with the best separability between ARVD patients and controls were near the right ventricular wall, at the third intercostal space. These channels showed pronounced differences in P waves compared to controls as well as the expected differences in QRS and T waves. Conclusion: Multichannel recordings, as in body surface mapping, add little to the reliability of diagnosing ARVD from ECGs. However, repositioning ECG electrodes to a high anterior position can improve the identification of ECG variations in ARVD. Additionally, increased P wave amplitude appears to be associated with ARVD.


Assuntos
Potenciais de Ação , Displasia Arritmogênica Ventricular Direita/diagnóstico , Eletrocardiografia , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Adulto , Idoso , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Estudos de Casos e Controles , Eletrocardiografia/instrumentação , Feminino , Ventrículos do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico
10.
Pacing Clin Electrophysiol ; 41(12): 1600-1605, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30267542

RESUMO

BACKGROUND: South Asians have a lower prevalence of atrial fibrillation (AF) compared with Caucasians despite higher rates of conventional risk factors and a higher incidence of stroke. It is not clear whether South Asians truly experience less AF or whether this is due to underdetection of the arrhythmia. Therefore, we aimed to determine whether South Asian patients with pacemakers have a lower incidence of device-detected subclinical episodes of AF compared with Caucasian controls. METHODS: We performed a retrospective cohort study of South Asian and Caucasian patients who underwent pacemaker implantation between 2006 and 2016. Subclinical AF episodes, detected during subsequent device clinic follow-up visits, were identified and the occurrence of clinical AF, cerebrovascular events, and all-cause mortality was recorded. RESULTS: A total of 5 648 patients underwent pacemaker implantation at the Yorkshire Heart Centre, UK, during the study period. Of these, 169 were South Asian and 72 met the eligibility criteria. The cumulative incidence of subclinical AF was significantly lower in South Asians compared with Caucasians (logrank P  =  0.002) with an annual event rate of 6.9% versus 13.9%, and South Asian ethnicity was an independent predictor of a lower incidence of subclinical AF (odds ratio =  0.43; 95% confidence interval  =  1.01-5.38). CONCLUSIONS: South Asians with an implanted pacemaker have a lower rate of subclinical AF compared with Caucasians.


Assuntos
Fibrilação Atrial/etnologia , Fibrilação Atrial/epidemiologia , Idoso , Sudeste Asiático/etnologia , Fibrilação Atrial/terapia , Inglaterra , Feminino , Humanos , Incidência , Masculino , Marca-Passo Artificial , Estudos Retrospectivos
11.
Europace ; 19(3): 356-363, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26941337

RESUMO

AIMS: Previous studies indicate that South Asians (SAs) may have a reduced risk of developing atrial fibrillation (AF) despite having a higher prevalence of traditional cardiovascular risk factors. This observational study was designed to explore the relative differences between SAs and Whites in a well-defined, multi-ethnic population with careful consideration of traditional cardiovascular risk factors that are thought to contribute to the development of AF. METHODS AND RESULTS: Anonymized data from 417 575 adults were sourced from primary care records within Bradford Metropolitan District, UK. Atrial fibrillation diagnosis was indicated by the presence on the AF Quality Outcomes Framework register. Self-reported ethnicity was mapped to census ethnic codes. The age-standardized prevalence rates of AF were calculated for comparison between the White and SA populations; our study sample presented relative proportions of 2.39 and 0.4%. Multivariable logistic regression analysis was performed to estimate the odds of developing AF given SA ethnicity. Adjustment for age, sex, and established risk factors found a 71% reduction in odds of AF in SAs when compared with Whites [odds ratio (OR): 0.29, 95% confidence interval (CI): 0.26-0.32]. When stratified by ethnicity, analyses revealed significantly different odds of AF for patients with diabetes; diabetes was not associated with the development of AF in the SA population (0.81, 95% CI: 0.63-1.05). CONCLUSION: This study, in a multi-ethnic population, presents ethnicity as a predictor of AF in which prevalence is significantly lower in SAs when compared with Whites. This is despite SAs having a higher frequency of established risk factors for the development of AF, such as ischaemic heart disease, heart failure, hypertension, and type 2 diabetes. These findings are consistent with previous literature and add weight to the need for further investigation, although this is the first study to investigate the differential associations of individual risk factors with development of AF.


Assuntos
Povo Asiático , Fibrilação Atrial/etnologia , Disparidades nos Níveis de Saúde , Saúde da População Urbana , População Branca , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/prevenção & controle , Comorbidade , Inglaterra/epidemiologia , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Prevalência , Fatores de Proteção , Medição de Risco , Fatores de Risco , Adulto Jovem
12.
Europace ; 19(12): 1944-1950, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28339804

RESUMO

AIMS: Measurement of circulating biomarkers of fibrosis may have a role in selecting patients and treatment strategy for catheter ablation. Pro-collagen type III N-terminal pro-peptide (PIIINP), C-telopeptide of type I collagen (ICTP), fibroblast growth factor 23 (FGF-23), and galectin 3 (gal-3) have all been suggested as possible biomarkers for this indication, but studies assessing whether peripheral levels reflect intra-cardiac levels are scarce. METHODS AND RESULTS: We studied 93 patients undergoing ablation for paroxysmal atrial fibrillation (AF) (n = 63) or non-paroxysmal AF (n = 30). Femoral venous, left and right atrial, and coronary sinus blood were analysed using ELISA to determine biomarker levels. Levels were compared with control patients (n = 36) and baseline characteristics, including left atrial voltage mapping data. C-telopeptide of type I collagen levels were higher in AF than in non-AF patients (P = 0.007). Peripheral ICTP levels were higher than all intra-cardiac levels (P < 0.001). Peripheral gal-3 levels were higher than left atrial levels (P = 0.001). Peripheral levels of FGF-23 and PIIINP were not significantly different from intra-cardiac levels. CS levels of ICTP were higher than right and left atrial levels (P < 0.001). gal-3 was higher in women vs. men (P ≤ 0.001) and with higher body mass index (P ≤ 0.001). ICTP levels increased with reducing ejection fraction (P ≤ 0.012). CONCLUSIONS: Atrial fibrillation patients have higher levels of circulating ICTP than matched non-AF controls. In AF ablation patients, intra-cardiac sampling of FGF-23 or PIIINP gives no further information over peripheral sampling. For gal-3 and ICTP, intra-cardiac sampling may be necessary to assess their association with intra-cardiac processes. None of the biomarkers is related to fibrosis assessed by left atrial voltage.


Assuntos
Fibrilação Atrial/sangue , Fibrilação Atrial/cirurgia , Remodelamento Atrial , Ablação por Cateter , Colágeno Tipo I/sangue , Fatores de Crescimento de Fibroblastos/sangue , Galectina 3/sangue , Átrios do Coração/metabolismo , Fragmentos de Peptídeos/sangue , Peptídeos/sangue , Pró-Colágeno/sangue , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Biomarcadores/sangue , Proteínas Sanguíneas , Estudos de Casos e Controles , Tomada de Decisão Clínica , Técnicas Eletrofisiológicas Cardíacas , Ensaio de Imunoadsorção Enzimática , Feminino , Fator de Crescimento de Fibroblastos 23 , Fibrose , Galectinas , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Valor Preditivo dos Testes , Resultado do Tratamento , Função Ventricular Esquerda
15.
J Antimicrob Chemother ; 70(2): 325-59, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25355810

RESUMO

Infections related to implantable cardiac electronic devices (ICEDs), including pacemakers, implantable cardiac defibrillators and cardiac resynchronization therapy devices, are increasing in incidence in the USA and are likely to increase in the UK, because more devices are being implanted. These devices have both intravascular and extravascular components and infection can involve the generator, device leads and native cardiac structures or various combinations. ICED infections can be life-threatening, particularly when associated with endocardial infection, and all-cause mortality of up to 35% has been reported. Like infective endocarditis, ICED infections can be difficult to diagnose and manage. This guideline aims to (i) improve the quality of care provided to patients with ICEDs, (ii) provide an educational resource for all relevant healthcare professionals, (iii) encourage a multidisciplinary approach to ICED infection management, (iv) promote a standardized approach to the diagnosis, management, surveillance and prevention of ICED infection through pragmatic evidence-rated recommendations, and (v) advise on future research projects/audit. The guideline is intended to assist in the clinical care of patients with suspected or confirmed ICED infection in the UK, to inform local infection prevention and treatment policies and guidelines and to be used in the development of educational and training material by the relevant professional societies. The questions covered by the guideline are presented at the beginning of each section.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/prevenção & controle , Gerenciamento Clínico , Humanos
16.
J Cardiovasc Electrophysiol ; 26(12): 1307-14, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26727045

RESUMO

INTRODUCTION: Catheter ablation of paroxysmal AF using the Cryoballoon (CRYO) has yielded similar success rates to conventional wide encirclement using radiofrequency catheter ablation (RFCA), but randomized data are lacking. Pilot data suggested a high success rate with a combined approach (COMBINED) using wide encirclement with RFCA followed by 2 CRYO applications to each vein. We compared these 3 strategies in a randomized controlled trial. METHODS AND RESULTS: Patients undergoing first time paroxysmal AF ablation were randomized to RFCA, CRYO, or COMBINED. Patients were followed up at 3, 6, and 12 months with 7 days of ambulatory ECG monitoring. Success was defined as freedom from arrhythmia without antiarrhythmic drugs after a single procedure. A total of 237 patients were randomized. Success at 1 year was achieved in 47% in the RFCA group, 67% in the CRYO group, and 76% in the COMBINED group (P < 0.001 for RFCA vs. CRYO, P<0.001 for RFCA vs. COMBINED, and P = 0.220 for CRYO vs. COMBINED). Procedure time was 211 (IQR 174-256) minutes for RFCA compared to 167 (136-202) minutes for CRYO and 278 (243-327) minutes for COMBINED (P < 0.001 for RFCA vs. COMBINED, RFCA vs. CRYO, and CRYO vs. COMBINED groups). CONCLUSIONS: Pulmonary vein isolation for paroxysmal AF is faster with CRYO and results in a higher single procedure success rate than conventional point by point RFCA. The COMBINED approach was not superior to CRYO alone.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Criocirurgia/métodos , Veias Pulmonares , Idoso , Antiarrítmicos/uso terapêutico , Ablação por Cateter/efeitos adversos , Terapia Combinada , Criocirurgia/efeitos adversos , Intervalo Livre de Doença , Eletrocardiografia Ambulatorial , Determinação de Ponto Final , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
17.
Pharmacoecon Open ; 8(3): 417-429, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38244143

RESUMO

BACKGROUND AND AIMS: Symptom control for atrial fibrillation can be achieved by catheter ablation or drug therapy. We assessed the cost effectiveness of a novel streamlined atrial fibrillation cryoballoon ablation protocol (AVATAR) compared with optimised antiarrhythmic drug (AAD) therapy and a conventional catheter ablation protocol, from a UK National Health Service (NHS) perspective. METHODS: Data from the AVATAR study were assessed to determine the cost effectiveness of the three protocols in a two-step process. In the first stage, statistical analysis of clinical efficacy outcomes was conducted considering either a three-way comparison (AVATAR vs. conventional ablation vs. optimised AAD therapies) or a two-way comparison (pooled ablation protocol data vs. optimised AAD therapies). In the second stage, models assessed the cost effectiveness of the protocols. Costs and some of the clinical inputs in the models were derived from within-trial cost analysis and published literature. The remaining inputs were derived from clinical experts. RESULTS: No significant differences between the ablation protocols were found for any of the clinical outcomes used in the model. Results of a within-trial cost analysis show that AVATAR is cost-saving (£1279 per patient) compared with the conventional ablation protocol. When compared with optimised AAD therapies, AVATAR (pooled conventional and AVATAR ablation protocols efficacy) was found to be more costly while offering improved clinical benefits. Over a lifetime time horizon, the incremental cost-effectiveness ratio of AVATAR was estimated as £21,046 per quality-adjusted life-year gained (95% credible interval £7086-£71,718). CONCLUSIONS: The AVATAR streamlined protocol is likely to be a cost-effective option versus both conventional ablation and optimised AAD therapy in the UK NHS healthcare setting.

18.
Artigo em Inglês | MEDLINE | ID: mdl-38478165

RESUMO

BACKGROUND: CRAFT was an international, multicentre, randomised controlled trial across 11 sites in the United UK and Switzerland. Given the evidence that pulmonary vein triggers may be responsible for atrial flutter (AFL) as well as atrial fibrillation (AF), we hypothesised that cryoballoon pulmonary vein isolation (PVI) would provide greater symptomatic arrhythmia reduction than cavotricuspid isthmus (CTI) ablation, whilst also reducing the subsequent burden of AF. Twelve-month outcomes were previously reported. In this study, we report the extended outcomes of the CRAFT study to 36 months. METHODS: Patients with typical AFL and no evidence of AF were randomised 1:1 to cryoballoon PVI or radiofrequency CTI. All patients received an implantable loop recorder (ILR) for continuous cardiac rhythm monitoring. The primary outcome was time-to-symptomatic arrhythmia recurrence > 30 s. Secondary outcomes included time-to-first-AF episode ≥ 2 min. The composite safety outcome included death, stroke and procedural complications. RESULTS: A total of 113 patients were randomised to cryoballoon PVI (n = 54) or radiofrequency CTI ablation (n = 59). Ninety-one patients reconsented for extended follow-up beyond 12 months. There was no difference in the primary outcome between arms, with the primary outcome occurring in 12 PVI vs 11 CTI patients (HR 0.97; 95% CI 0.43-2.20; p = 0.994). AF ≥ 2 min was significantly less frequent in the PVI arm, affecting 26 PVI vs 36 CTI patients (HR 0.48; 95% CI 0.29-0.79; p = 0.004). The composite safety outcome occurred in 5 PVI and 6 CTI patients (p = 0.755). CONCLUSION: Cryoballoon PVI shows similar efficacy to radiofrequency CTI ablation in reducing symptomatic arrhythmia recurrence in patients presenting with isolated typical AFL but significantly reduces the occurrence of subsequent AF.

19.
J Clin Med ; 12(22)2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-38002591

RESUMO

Intracoronary guidewires used in percutaneous coronary intervention can also be configured to provide temporary ventricular pacing. Trans coronary electrophysiological parameters recorded by employing coronary guidewires may have a potential role in assessing myocardial viability and could provide a means to make an immediate on-table decision about revascularisation. To date, some small studies have demonstrated the safety of this technique in temporary cardiac pacing, but further research is required to refine this approach and establish its clinical utility in myocardial viability assessment. In this review we discuss the potential role of trans coronary electrophysiology in the assessment of myocardial viability.

20.
BJPsych Bull ; 47(1): 11-16, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34823623

RESUMO

AIMS AND METHOD: People diagnosed with dementia are often started on acetylcholinesterase inhibitors (AChEIs). As AChEIs can be associated with cardiac side-effects, an electrocardiogram (ECG) is sometimes requested before treatment. Previous work has suggested there is little consensus as to when or how ECGs should be obtained. This can create inconsistent practice, with patient safety, economic and practical repercussions. We surveyed 305 UK memory clinic practitioners about prescribing practice. RESULTS: More than 84% of respondents completed a pulse and cardiac history before prescribing AChEIs. Opinion was divided as to who should fund and conduct ECGs. It was believed that obtaining an ECG causes patients inconvenience and delays treatment. Despite regularly interpreting ECGs, 76% of respondents did not update this clinical skill regularly. CLINICAL IMPLICATIONS: The variation in practice observed has service-level and patient implications and raises potential patient safety concerns. Implementing national guidelines or seeking novel ways of conducting cardiac monitoring could help standardise practice.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA