Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Br J Neurosurg ; 37(3): 296-297, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31835919

RESUMO

A 48-year-old man hospitalized for subarachnoid hemorrhage harbored a ruptured aneurysm arising from an anomalous hyperplastic anterior choroidal artery. Endovascular treatment was performed and the aneurysm was successfully embolized with neck remnant. The anterior choroidal artery is a very important artery supplying critical brain structures in the treatment of intracranial vascular disease. Anomalous hyperplastic anterior choroidal artery is rare, so the embryological perspective is important for its recognition in surgical procedures.


Assuntos
Aneurisma Roto , Aneurisma Intracraniano , Hemorragia Subaracnóidea , Masculino , Humanos , Pessoa de Meia-Idade , Aneurisma Intracraniano/complicações , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Artéria Carótida Interna/cirurgia , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/etiologia , Hemorragia Subaracnóidea/cirurgia , Artérias Cerebrais , Aneurisma Roto/complicações , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Hiperplasia/patologia
2.
J Stroke Cerebrovasc Dis ; 25(3): e33-7, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26738813

RESUMO

BACKGROUND: Infectious intracranial aneurysms (IIAs) are rare but can cause substantial morbidity and mortality. We aimed to re-evaluate the role of endovascular therapy for the treatment of IIAs. METHODS: This study is a retrospective review of patients diagnosed with IIAs and treated by endovascular therapy in our institutions over the past 13 years. RESULTS: Four patients were diagnosed with infectious endocarditis with a total of 5 IIAs. Three of the 4 patients had ruptured IIAs. Two presented with intracerebral hemorrhage, one with subarachnoid hemorrhage, and one with cerebral infarction. The distal middle cerebral artery (MCA) was the most common site, followed by the distal segment of the posterior cerebral artery. Three patients were treated by parent artery occlusion and one by direct aneurysm obliteration. There were no periprocedural complications. One IIA treated by direct aneurysm occlusion was recanalized within 1 year and required a second embolization. Outcomes were measured by the modified Rankin Scale on discharge: 2 patients scored 0, 1 patient scored 1, and 1 patient scored 3. CONCLUSION: IIAs located deep in the brain or on the peripheral MCA can be safely treated with endovascular therapy even when they are lying in the eloquent cortex.


Assuntos
Procedimentos Endovasculares/métodos , Infecções/complicações , Aneurisma Intracraniano/etiologia , Aneurisma Intracraniano/terapia , Adulto , Angiografia Cerebral , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomógrafos Computadorizados , Resultado do Tratamento , Adulto Jovem
3.
Geriatrics (Basel) ; 9(1)2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38247988

RESUMO

This study investigated prognostic factors in elderly patients (80 years and older) undergoing mechanical thrombectomy (MT) for anterior circulation large vessel occlusion (LVO) in acute stroke treatment. Of 59 cases, 47.5% achieved a favorable outcome (mRS ≤ 3) at three months, with a mortality rate of 20.3%. Factors associated with better outcomes included younger age, lower admission National Institute of Health Stroke Scale (NIHSS) scores, lower N-terminal pro-brain natriuretic peptide (NT-proBNP) and D-dimer levels, the presence of the first pass effect (FPE), and successful recanalization. However, logistic regression showed that only lower admission NIHSS scores were significantly correlated with favorable outcomes. In addition, this study suggests that lower admission NT-proBNP and D-dimer levels could potentially serve as prognostic indicators for elderly LVO patients undergoing MT.

4.
Neuroradiol J ; 37(1): 54-59, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37902468

RESUMO

PURPOSE: Recently, a novel device, the Woven Endo Bridge (WEB), was developed for wide-neck bifurcation intracranial aneurysms (WNBAs). The aim of this study is to investigate factors that contribute to adequate occlusion (AO) after the operation using detailed radiological images. METHODS: The subjects were 29 patients with 29 aneurysms who received WEB implantation for WNBAs between December 2020 and April 2022. We assessed the contributing factors to AO by retrospectively comparing the AO group and non-AO group. RESULTS: The mean age was 64.6 ± 13.1 years, and 18 were female (62.1%). The mean aneurysm dome width, aneurysm height, and aneurysm neck diameter were 4.8 ± 0.6 mm, 5.1 ± 0.6 mm, and 3.7 ± 0.6 mm, respectively. After about 6 months, 22 of 29 patients (75.9%) had AO. Complications were observed in 2 patients (6.9%), renal artery injury in one, and minor cerebral infarction in another, but the modified Rankin scale scores of both patients remained unchanged. Multivariate analysis extracted only WEB shape modification (WSM) as a contributing factor to AO (odds ratio: 0.912, p = 0.0287). CONCLUSION: WEB implantation for WNBAs was a treatment modality with acceptable efficacy and safety. WSM was the only significant factor contributing to non-AO after the treatment. We should clarify the mechanisms or causes of WSM to achieve AO after WEB implantation in future.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Resultado do Tratamento , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Estudos Retrospectivos , Embolização Terapêutica/métodos
5.
Asian J Neurosurg ; 19(2): 168-173, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38974449

RESUMO

Objective With the expansion of indications of flow diverter (FD) for cerebral aneurysms, FD placement for posterior communicating artery (Pcom) aneurysms has been approved. However, it is controversial whether Pcom aneurysms should be treated with FD or not. In this study, we report the outcome of FD treatment for Pcom aneurysms in Japan. Materials and Methods We retrospectively analyzed 36 patients with 38 aneurysms treated with FD placement for Pcom aneurysms between 2015 and 2021 in our hospital. We divided our cases into complete occlusion (CO) and non-CO groups. And we extracted contributing factors to CO using multivariate analysis. We also compared the complications rate among the three types of FDs. Results CO was obtained in 29 cases (79.3%), and complications were observed in 3 cases (7.9%). Multivariate analysis revealed that the type of Pcom branch from the aneurysmal dome was a significant factor contributing to CO (odds ratio: 0.0052, 95% confidence interval 0.000048-0.584, p = 0.029). In terms of complications, complication rate was significantly higher in the Flow-Redirection Endoluminal Device (FRED) group ( p = 0.0491). Conclusion The outcome for Pcom aneurysms treated by FD was acceptable. When treating, we must pay attention to where Pcom originates. Achieving CO with FD is difficult for aneurysms where the Pcom branches from the dome. Furthermore, when treating Pcom aneurysms with FRED, it is necessary to be careful about thromboembolic complications.

6.
J Neuroendovasc Ther ; 18(3): 65-74, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38559453

RESUMO

Treatment for wide-neck bifurcation cerebral aneurysms (WNBAs) is widely performed by endovascular treatment as well as open surgical clipping. However, due to factors such as the shape and size of the aneurysms, as well as the anatomical features of surrounding branch vessels, there are some cases in which simple coiling or conventional adjunctive techniques, such as balloon-assisted or neck bridge stent-assisted coiling, are not sufficient to achieve a satisfactory cure. Against this backdrop, the device known as the Woven EndoBridge (WEB) (MicroVention, Aliso Viejo, CA, USA) was developed and can be deployed directly into the aneurysm for treatment. Over a decade has passed since its development, and it is now used in many countries worldwide. This review provides insights into the evolution of the WEB device from its development to the date of this writing, highlighting the unique features of the device and its treatment indications. Additionally, it discusses the posttreatment course, perspectives on recurrence and retreatment, imaging assessments, and potential off-label use based on numerous studies primarily conducted in Europe and the USA.

7.
Oper Neurosurg (Hagerstown) ; 26(2): 180-187, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37819087

RESUMO

BACKGROUND AND OBJECTIVES: Planning/guidance software became important tools for physicians' presurgical optimal decision-making. However, there are no intracranial stent products with specifically associated simulation software. We report the "premarket" clinical trial of a new braided stent with a customized simulation software. METHODS: A stent system with 3 mesh density types (16, 24, and 32 wire mesh) was designed based on computational flow dynamics technology, and a simulation software (virtual stent planner [VSP]) was developed for the optimal stent deployment planning. Stents were selected after simulation on preoperative 3D-processed angioimages, and accuracy of the VSP was evaluated. RESULTS: Thirty-three unruptured intracranial aneurysms were successfully treated with VSP guidance. Twenty aneurysms (61%) were anterior circulation aneurysms, and 13 (39%) were posterior circulation aneurysms. The average aneurysm size was 7.1 mm, and the mean follow-up period was 19.2 months (11-39.0). There was no major recurrence or retreatment during follow-up, 2 morbidity cases, and no mortality. VSP planning presented slightly smaller stent dimensions compared with postdeployment: 24.2 vs 25.5 mm average, error -1.3 mm, and difference rate-5.46%. CONCLUSION: Based on this result, the new stents and software guidance system were approved by the Ministry of Health and Welfare as a combined medical device. VSP provided precise deployment with minimal error compared with actual stent and can contribute to better stent deployment even for less experienced physicians.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Embolização Terapêutica/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Estudos Prospectivos , Software , Stents
8.
Surg Neurol Int ; 14: 92, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37025526

RESUMO

Background: The pipeline embolization device (PED) is the most common flow diverter device in the world. To date, there have been no reports of treatment outcomes specific to intradural internal carotid artery (ICA) aneurysms. The safety and efficacy of the PED treatments for intradural ICA aneurysms are reported. Methods: 131 patients with 133 aneurysms underwent PED treatments for intradural ICA aneurysms. The mean aneurysm dome size and neck length were 12.7 ± 4.3 mm and 6.1 ± 2.2 mm, respectively. We used adjunctive endosaccular coil embolization for 88 aneurysms (66.2%). A total of 113 aneurysms (85%) were angiographically followed up 6 months following the procedure, and 93 aneurysms (69.9%) were followed up for 1 year. Results: The angiographic outcome at 6 months showed that 94 (83.2%) aneurysms had O'Kelly-Marotta (OKM) grade D, 6 (5.3%) had C, 10 (8.8%) had B, and 3 (2.7%) had A. At 1 year, 82 (88.2%) aneurysms had OKM grade D, 6 (6.5%) had C, 3 (3.2%) had B, and 2 (2.2%) had A. Multivariate analysis showed that aneurysm neck size and adjunctive coiling were statistically significant in aneurysm occlusion status. Major morbidity modified Rankin Scale >2 and mortality rates related to procedures were 3.0% and 0%, respectively. Delayed aneurysm ruptures were not observed. Conclusion: These results reveal that PED treatment of intradural ICA aneurysms is safe and efficacious. The combined use of adjunctive coil embolization not only prevents delayed aneurysm ruptures but also contributes to an increase in the rate of complete occlusion.

9.
Neuroradiol J ; 36(5): 601-609, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37106524

RESUMO

BACKGROUND: Contrast-associated acute kidney injury (CA-AKI) can develop after intravascular administration of iodinated contrast media. Neutrophil gelatinase-associated lipocalin (NGAL) is an early marker for AKI that helps to detect subclinical CA-AKI. We investigated the incidence of and risk factors for clinical and subclinical CA-AKI in patients who underwent neuroendovascular surgery. METHODS: We retrospectively investigated 228 patients who underwent neuroendovascular surgery in 2020. Changes in serum creatinine and urine output were used to detect clinical CA-AKI. Urine NGAL concentration was used to detect subclinical CA-AKI in 67 out of 228 patients. RESULTS: In 228 patients, serum creatinine, hemoglobin, hematocrit, total protein, and blood urea nitrogen (BUN) decreased significantly (p < 0.001) after surgery. However, serum creatinine decreased less significantly (p < 0.05) than hemoglobin, hematocrit, total protein, and BUN on postoperative Day 3. Two patients out of 228 developed clinical CA-AKI, and seven patients out of 67 with urine NGAL measurements developed subclinical CA-AKI. Multivariate regression analysis revealed that diabetes mellitus and carotid artery stenosis were significantly (p < 0.05) associated with the development of clinical and/or subclinical CA-AKI. CONCLUSION: There was a large difference between the incidences of clinical CA-AKI (0.88%) and subclinical CA-AKI (10.4%). The difference might have primarily resulted from the different sensitivities between serum creatinine and urine NGAL and possibly from underestimation of the incidence of clinical AKI due to a postoperative decrease in serum creatinine caused by hemodilution. In addition to diabetes mellitus, carotid artery stenosis could also be a risk factor for CA-AKI.

10.
Neurol Med Chir (Tokyo) ; 63(2): 58-64, 2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36543205

RESUMO

The flow diverter has been shown to be a safe and effective device for large cerebral aneurysms in the proximal internal carotid artery (ICA). Recently, its indication has been expanded to small- and medium-sized cerebral aneurysms in the distal segment of the ICA. In this study, we report a single-center, retrospective investigation of the safety and efficacy of the Pipeline Flex device to treat these aneurysms. Of the patients who underwent Pipeline implantation for small- and medium-sized ICA aneurysms (≤12 mm) at our hospital between July 2013 and October 2021, 102 patients with 104 aneurysms were included in this study. The mean age of the patients was 57.7 ± 12.1 years, and 94 (90.4%) were female. The mean aneurysmal dome diameter was 9.2 ± 2.3 mm, the mean neck diameter was 5.3 ± 1.6 mm, and the mean dome-to-neck ratio was 1.8 ± 0.5. Twenty-five patients (24.0%) had incorporated vessels from the aneurysm. Complete occlusion of the aneurysms was obtained in 96 patients (92.3%). There were no cases of parent artery stenosis or major stroke after the procedure. Absence of incorporated vessel from the aneurysm dome and adjunctive coil embolization are statistically significant factors indicating complete occlusion in multivariate analysis. The time to complete occlusion was determined earlier with the use of the Pipeline Shield (p = 0.0386) and with adjunctive coils (p = 0.0025). We showed that Pipeline implantation for small- and medium-sized aneurysms was safe and highly effective.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Estudos Prospectivos , Stents , Angiografia Cerebral/métodos
11.
Neurochem Res ; 37(4): 680-8, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22139482

RESUMO

This report entails in vivo and in vitro studies concerned with free radical species involved in brain ischemia. The participation of reactive oxygen species (ROS) and reactive nitrogen species (RNS) in the early manifestation of cerebral ischemia/reperfusion was investigated in gerbils exposed to transient global ischemia using 4-OH-2,2,6,6-tetramethylpiperidine-1-oxyl (TPL), a well-known antioxidant. TPL treatment reversed cerebral postischemic hypoperfusion and tissue edema in these animals. The findings are consistent with ROS/RNS participation in tissue injury and the reduction of cerebromicrovascular blood flow (CBF) during postischemic recirculation. The activation/deactivation of signal transduction pathway by oxidation/antioxidation [i.e., using hydrogen peroxide (H2O2)/TPL] was evaluated in cultured human brain endothelial cells (HBEC) to assess the involvement of endothelial-dependent mechanisms. The data showed that H2O2 activates various "stress" kinases and vasodilalator-stimulated phosphoprotein (VASP); activation of this pathway was reduced by inhibitors of Rho- or IP-3 kinases, as well as TPL. H2O2 also induced cytoskeleton (actin) rearrangements in HBEC; this effect was prevented by inhibitors of Rho/IP3 kinase or TPL. The observed activation/deactivation of H2O2-induced "stress" kinase is in agreement with the reported capacity of ROS/RNS to stimulate the oxidative signal transduction pathway. The noted TPL reduction of H2O2-induced phosphorylation of kinase strongly suggests that the beneficial effect of TPL implicates the stress signal transduction pathway. This may represent a mechanism for the cerebral postischemic manifestations observed by in vivo experiments.


Assuntos
Antioxidantes/uso terapêutico , Isquemia Encefálica/metabolismo , Óxidos N-Cíclicos/farmacologia , Óxidos N-Cíclicos/uso terapêutico , Endotélio Vascular/fisiologia , Transdução de Sinais/fisiologia , Animais , Antioxidantes/farmacologia , Isquemia Encefálica/tratamento farmacológico , Células Cultivadas , Endotélio Vascular/efeitos dos fármacos , Gerbillinae , Humanos , Estresse Oxidativo/efeitos dos fármacos , Estresse Oxidativo/fisiologia , Espécies Reativas de Oxigênio/metabolismo , Transdução de Sinais/efeitos dos fármacos , Marcadores de Spin
12.
Artigo em Inglês | MEDLINE | ID: mdl-21806503

RESUMO

In a previous dose escalation study our group found that combining 90µg/kg rFVIIa with HBOC-201 reduced blood loss and improved physiologic parameters compared to HBOC alone. In this follow-up study in a swine liver injury model, we found that while there were no adverse hematology effects and trends observed in the previous study were confirmed, statistical significance could not be reached. Additional pre-clinical studies are indicated to identify optimal components of a multifunctional blood substitute for clinical use in trauma.


Assuntos
Fator VIIa/farmacologia , Hidratação/métodos , Hemoglobinas/farmacologia , Hospitais , Proteínas Recombinantes/farmacologia , Choque Hemorrágico/tratamento farmacológico , Suínos , Animais , Substitutos Sanguíneos/farmacologia , Volume Sanguíneo/efeitos dos fármacos , Interações Medicamentosas , Fator VIIa/uso terapêutico , Feminino , Hemoglobinas/uso terapêutico , Masculino , Oxigênio/metabolismo , Proteínas Recombinantes/uso terapêutico , Choque Hemorrágico/metabolismo , Choque Hemorrágico/patologia , Choque Hemorrágico/fisiopatologia , Análise de Sobrevida
13.
Clin Neurol Neurosurg ; 217: 107275, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35525104

RESUMO

OBJECTIVE: Y-stent-assisted coil embolization is indicated for the treatment of complex intracranial bifurcation aneurysms. However, the long-term outcomes associated with this technique remain unclear. The purpose of this study was to evaluate the long-term outcomes of Y-stent-assisted coil embolization using the Low-profile Visualized Intraluminal Support Junior (LVIS Jr) device. METHODS: We retrospectively reviewed our databases to identify patients treated with Y-stent-assisted coiling using LVIS Jr. Digital subtraction angiography, silent magnetic resonance angiography (MRA), and time-of-flight MRA were performed at 1 year after the procedure. Patients also received an annual follow-up using MRA. Aneurysm occlusion status was classified into complete occlusion (CO), neck remnant (NR), and body filling (BF). Clinical outcomes were assessed using the modified Rankin Scale. RESULTS: Twenty-one patients (22 aneurysms) were included in this study. All procedures were performed successfully. Immediate postprocedural angiograms showed CO in 13 aneurysms (59.1%), NR in two aneurysms (9.1%), and BF in seven aneurysms (31.8%). One-year follow-up angiograms revealed CO in 86.4% of patients. Only one patient had a major recurrence and required retreatment. The mean follow-up duration was 43.5 months. The last angiographic studies demonstrated CO in 18 aneurysms (81.8%), NR in three aneurysms (13.6%), and BF in one aneurysm (4.5%). Periprocedural and delayed complications occurred in two patients and one patient, respectively. There was no permanent morbidity or death. The modified Rankin Scale scores at last clinical follow-up were equal to those before the procedures in all patients. CONCLUSION: Y-stent-assisted coil embolization using LVIS Jr for intracranial bifurcation aneurysms has favorable long-term angiographic and clinical outcomes.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Angiografia Cerebral/métodos , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Estudos Retrospectivos , Stents , Resultado do Tratamento
14.
Neurol Med Chir (Tokyo) ; 62(1): 19-27, 2022 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-34707069

RESUMO

Flow diverter (FD) therapy using Pipeline embolization device (PED) has become an important alternative to treat internal carotid artery (ICA) aneurysms. Herein, we report the long-term outcome for 3 years after FD therapy using PED for ICA aneurysms in Japan. The patients who underwent angiographical and/or clinical follow-up for 3 years after the FD therapy using PED of large or giant unruptured ICA aneurysms from December 2012 at our university hospital are the subjects of this study. We retrospectively reviewed the in- and outpatients' medical charts, and written operative and radiological records. There were 84 patients with 90 aneurysms who could be clinically and/or angiographically followed up for 3 years. Of these, 7 aneurysms were only available for clinical follow-up. Of the remaining 83 aneurysms, 6 aneurysms had vessel occlusion due to stent thrombosis or parent artery occlusion, and 60 of the remaining 77 (77.9%) had complete occlusion. In multivariate analysis, older age (>70 years), wide neck, and non-adjunctive coiling contributed statistically significantly to incomplete occlusion. Of the 84 patients, 2 patients (2.4%) had delayed complications between 6 months and 3 years after the initial FD placement. Three patients (3.6%) had poor outcome due to postoperative major stroke complications, 2 of which were acute complications. The long-term results after FD therapy are good both angiographically and clinically. Endothelialization of the aneurysmal neck and intra-aneurysmal thrombosis contribute to complete occlusion. The primary reason for the somewhat low complete occlusion in Japan may be the patients are generally older.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Idoso , Artéria Carótida Interna/diagnóstico por imagem , Embolização Terapêutica/efeitos adversos , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Japão , Estudos Retrospectivos , Stents , Resultado do Tratamento
15.
Neuroradiol J ; 35(1): 77-85, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34187225

RESUMO

PURPOSE: Among all stents available for neuroendovascular therapy, the low-profile visible intraluminal support stent bears the highest metal coverage ratio. We deployed a low-profile visible intraluminal support stent with a delivery wire or/and microcatheter system push action to shorten the low-profile visible intraluminal support stent and thus achieve a flow diversion effect. We report our single-institution experience with the use of low-profile visible intraluminal support stents for intentionally shortened deployment (shortening group) and non-shortened deployment (non-shortening group) for unruptured intracranial aneurysms. METHODS: We retrospectively reviewed the medical records of 130 patients with 131 intracranial aneurysms who were treated with low-profile visible intraluminal support stent-assisted coil embolization from February 2016-January 2019. All perioperative complications were noted. Every 6 months, we re-examined the patients with cerebral angiography or magnetic resonance angiography. The outcomes of aneurysm occlusion were evaluated by the modified Raymond-Roy occlusion classification. We used the finite element method and computational fluid dynamics to investigate the hemodynamics after shortened low-profile visible intraluminal support stent deployment. RESULTS: Immediately after treatment, the modified Raymond-Roy occlusion classification was significantly better in the shortening group than in the non-shortening group (p<0.05). The latest angiographic outcomes showed the same tendency. Hemodynamic analysis by computational fluid dynamics suggested an adequate flow diversion effect with the use of our intentional shortening method. CONCLUSIONS: Stent-assisted coil embolization using this technique showed good results of a high complete occlusion rate and low complication rate. These findings suggest that shortened low-profile visible intraluminal support stent deployment yields a flow diversion effect and may lead to early intra-aneurysmal thrombus formation.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Prótese Vascular , Angiografia Cerebral , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Estudos Retrospectivos , Stents , Resultado do Tratamento
16.
J Surg Res ; 169(1): 92-8, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20070980

RESUMO

BACKGROUND: Fabric-like hemostatic dressings offer promise for hemorrhage control in noncompressible areas, especially given their similarity in form to standard gauze currently in use. Recently, two such products, Combat Gauze (CBG) and TraumaStat (TMS), were introduced. Their performance is evaluated in two vascular injury models. MATERIALS AND METHODS: The dressings were evaluated in anesthetized Yorkshire pigs, hemorrhaged by full transection of the femoral vasculature with 2 min free bleeding period (CBG = 6, TMS = 6) or by 4 mm femoral arterial puncture with 45 s free bleeding period (CBG = 8, TMS = 8). After injury, dressings were applied, followed by 5 min of manual compression and then 500 mL resuscitation fluid infused over 30 min. Vital signs, blood pressure, and blood loss were recorded throughout the 3-h experiment. Bleeding control was the primary outcome. RESULTS: All animals had similar pretreatment mean arterial pressure (MAP) (∼ 36.5 mmHg); pretreatment blood loss following injury was similar for both dressing groups in the two models [24% ± 8% estimated blood volume (EBV) 2 min after transection and 17% ± 4% EBV 45 s after puncture. Incidence of post-treatment bleeding, primarily occurring after release of manual compression or restoration of blood pressure, was more frequent in the puncture model (17% with both CBG and TMS) than the transection model (57% with CBG versus 75% with TMS). Post-treatment blood loss not controlled by the dressing was 19% ± 22% and 31% ± 17% EBV, for CBG and TMS, respectively. Survival rate was 100% for both dressings in the transection model, and was 88% for CBG and 50% for TMS in the puncture model. CONCLUSIONS: These findings indicated that CBG and TMS were similarly effective in improving hemostasis. These two fabric-like dressings showed easy application and removal, leaving a clean wound for surgical repair.


Assuntos
Bandagens , Virilha/lesões , Hemorragia/terapia , Hemostáticos/uso terapêutico , Animais , Pressão Sanguínea/fisiologia , Artéria Femoral/lesões , Artéria Femoral/cirurgia , Hemorragia/mortalidade , Hemorragia/fisiopatologia , Técnicas Hemostáticas , Modelos Animais , Taxa de Sobrevida , Suínos
17.
Neuroradiol J ; 33(6): 465-470, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33283673

RESUMO

PURPOSE: There have been many reports on the risks of enlargement and rupture of residual aneurysms and de novo aneurysm formation in the contralateral internal carotid artery after parent artery occlusion (PAO). In the present study, we investigated the efficacy of flow diverter device placement (FDDP) for the treatment of contralateral internal carotid artery aneurysms after PAO. METHODS: After 11 patients, who had bilateral large or giant internal carotid aneurysms, were treated for either side with PAO or FDDP, they underwent FDDP for residual lesions in our hospital between October 2015 and June 2018. The patients were divided into two groups, depending on the prior procedure: PAO or FDDP. The embolic state after subsequent FDDP was evaluated by angiography. The embolic state was graded using the O'Kelly Marotta scale. Patients' characteristics and the embolic state of intracranial aneurysms after FDDP were compared between the two groups. RESULTS: Comparing patients' characteristics between the PAO group and FDDP group, statistically significant differences were observed in laterality of the lesions and the interval between prior treatment and FDDP for residual aneurysms (p < 0.05). The embolic state at the one-year follow-up revealed that there could be significantly sufficient embolisation in the FDDP group (p < 0.05). CONCLUSION: When FDDP is performed for the contralateral lesion after PAO treatment, it is difficult to attain sufficient embolisation of intracranial aneurysms because haemodynamic load in this procedure is large compared to that in a regular FDDP.


Assuntos
Doenças das Artérias Carótidas/terapia , Artéria Carótida Interna/patologia , Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças das Artérias Carótidas/diagnóstico por imagem , Angiografia Cerebral , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Retratamento
18.
Interv Neuroradiol ; 26(5): 532-538, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32727310

RESUMO

PURPOSE: Antiplatelet therapy initiated before flow diverter placement is effective for the prevention of ischemic complications. However, the effectiveness of oral anticoagulant treatment is unclear. This retrospective study evaluated the complications and obliteration rates after flow diverter placement in patients taking anticoagulants. METHODS: A total of 155 cases were treated by Pipeline Flex placement for unruptured large and giant cerebral aneurysms in our hospital between October 2015 and June 2019. The groups of 8 patients taking anticoagulants before operation and 147 patients not taking anticoagulants were compared. RESULTS: Clopidogrel oral dose (P = 0.002) was significantly lower in the anticoagulant group. Delayed aneurysm rupture (P = 0.002) and additional treatment (P = 0.009) rates were significantly higher and complete obliteration rate (P = 0.011) was lower in the anticoagulant group. CONCLUSIONS: Additional oral anticoagulant administration before flow diverter placement does not reduce ischemic complications compared to dual antiplatelet therapy, but does increase hemorrhagic complications, especially delayed aneurysm rupture. Complete obliteration of the cerebral aneurysm is difficult to achieve in patients taking anticoagulants.


Assuntos
Clopidogrel/uso terapêutico , Inibidores do Fator Xa/uso terapêutico , Aneurisma Intracraniano/terapia , Inibidores da Agregação Plaquetária/uso terapêutico , Stents , Idoso , Quimioterapia Combinada , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos
19.
J Clin Neurosci ; 80: 87-91, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33099374

RESUMO

Authors reported the anatomical and clinical results of the stent assisted coiling (SAC) of unruptured middle cerebral artery (MCA) aneurysms using Low-profile Visualized Intraluminal Support Junior (LVIS Jr.). Forty-seven MCA aneurysms in 46 patients were the subjects of this study. The mean aneurysm size, neck width were 4.5 ± 1.8 mm, 3.0 ± 1.0 mm, respectively. Immediate anatomical outcomes were class Ⅰ in 31 (65.0%), class Ⅱ in 5 (10.6%) and class III in 11 (23.4%) patients according to Raymond-Roy classification. The latest anatomical outcomes were class Ⅰ in 33 (86.8%), class Ⅱ in 2 (5.3%) and class III in 3 (7.9%) patients. The change of aneurysm obliteration status were unchanged in 27 (71.0%), improved in 9 (23.7%) and worsen in 2 (5.3%). There were no recurrence necessitating additional treatment. Two patients suffered from angiographically evident in-stent thrombosis, but their clinical outcomes remain good. The modified Rankin scale at discharge were 0 in 45 patients, 1 in 1 patient. No patient showed clinical worsening during the clinical follow-up period at outpatient clinic (mean, 27.4 months). SAC of unruptured MCA aneurysms using LVIS Jr. provide safe and durable effect with high complete obliteration rate recurrence rate.


Assuntos
Embolização Terapêutica/instrumentação , Procedimentos Endovasculares/instrumentação , Aneurisma Intracraniano/terapia , Stents , Adulto , Idoso , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
20.
NMC Case Rep J ; 7(1): 5-10, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31938675

RESUMO

There have recently been reports of patients who developed postprocedural symptoms or alterations due to delayed foreign body embolisms observed in imaging findings. Polymer coating of devices have been described as a possible cause of foreign body embolisms, manifesting in delayed granulomatous responses and exhibiting characteristic imaging findings. In four of 4,025 patients who underwent coil embolization in our hospital or its affiliated facilities, similar findings were observed. Delayed lesions appeared between 1 month and 1 year after the procedures. There was extensive edema in the perfusion area of the treated vessels. In two cases examined by contrast-enhanced magnetic resonance imaging, multiple solid enhancing lesions within vasogenic edema were observed. Biopsy revealed a membranous foreign body in a blood vessel with surrounding foreign body granuloma formation in 1 case. Because these findings are similar to those of cases reported previously, they were considered as a foreign body embolism due to coating separations from the devices. Polymer coating separation occurs most frequently from guidewires. Especially if a metal introducer is used, the risk of separation increases. Surgeons should carefully follow the manufacturers' instructions when they use these devices and should acknowledge and report any events that may occur. Although these complications are extremely rare, further studies are warranted of similar cases; and we should prepare and share information on these intravascular devices for wide-scale dissemination in the industry.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA