Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 390(15): 1382-1393, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38587239

RESUMO

BACKGROUND: The effects of temporary mechanical circulatory support with a microaxial flow pump on mortality among patients with ST-segment elevation myocardial infarction (STEMI) complicated by cardiogenic shock remains unclear. METHODS: In an international, multicenter, randomized trial, we assigned patients with STEMI and cardiogenic shock to receive a microaxial flow pump (Impella CP) plus standard care or standard care alone. The primary end point was death from any cause at 180 days. A composite safety end point was severe bleeding, limb ischemia, hemolysis, device failure, or worsening aortic regurgitation. RESULTS: A total of 360 patients underwent randomization, of whom 355 were included in the final analysis (179 in the microaxial-flow-pump group and 176 in the standard-care group). The median age of the patients was 67 years, and 79.2% were men. Death from any cause occurred in 82 of 179 patients (45.8%) in the microaxial-flow-pump group and in 103 of 176 patients (58.5%) in the standard-care group (hazard ratio, 0.74; 95% confidence interval [CI], 0.55 to 0.99; P = 0.04). A composite safety end-point event occurred in 43 patients (24.0%) in the microaxial-flow-pump group and in 11 (6.2%) in the standard-care group (relative risk, 4.74; 95% CI, 2.36 to 9.55). Renal-replacement therapy was administered to 75 patients (41.9%) in the microaxial-flow-pump group and to 47 patients (26.7%) in the standard-care group (relative risk, 1.98; 95% CI, 1.27 to 3.09). CONCLUSIONS: The routine use of a microaxial flow pump with standard care in the treatment of patients with STEMI-related cardiogenic shock led to a lower risk of death from any cause at 180 days than standard care alone. The incidence of a composite of adverse events was higher with the use of the microaxial flow pump. (Funded by the Danish Heart Foundation and Abiomed; DanGer Shock ClinicalTrials.gov number, NCT01633502.).


Assuntos
Coração Auxiliar , Infarto do Miocárdio com Supradesnível do Segmento ST , Choque Cardiogênico , Idoso , Feminino , Humanos , Masculino , Coração Auxiliar/efeitos adversos , Incidência , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Choque Cardiogênico/cirurgia , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Resultado do Tratamento , Circulação Assistida/efeitos adversos , Circulação Assistida/instrumentação , Circulação Assistida/métodos
2.
N Engl J Med ; 382(2): 130-139, 2020 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-31733182

RESUMO

BACKGROUND: Subclinical leaflet thickening and reduced leaflet motion of bioprosthetic aortic valves have been documented by four-dimensional computed tomography (CT). Whether anticoagulation can reduce these phenomena after transcatheter aortic-valve replacement (TAVR) is not known. METHODS: In a substudy of a large randomized trial, we randomly assigned patients who had undergone successful TAVR and who did not have an indication for long-term anticoagulation to a rivaroxaban-based antithrombotic strategy (rivaroxaban [10 mg] plus aspirin [75 to 100 mg] once daily) or an antiplatelet-based strategy (clopidogrel [75 mg] plus aspirin [75 to 100 mg] once daily). Patients underwent evaluation by four-dimensional CT at a mean (±SD) of 90±15 days after randomization. The primary end point was the percentage of patients with at least one prosthetic valve leaflet with grade 3 or higher motion reduction (i.e., involving >50% of the leaflet). Leaflet thickening was also assessed. RESULTS: A total of 231 patients were enrolled. At least one prosthetic valve leaflet with grade 3 or higher motion reduction was found in 2 of 97 patients (2.1%) who had scans that could be evaluated in the rivaroxaban group, as compared with 11 of 101 (10.9%) in the antiplatelet group (difference, -8.8 percentage points; 95% confidence interval [CI], -16.5 to -1.9; P = 0.01). Thickening of at least one leaflet was observed in 12 of 97 patients (12.4%) in the rivaroxaban group and in 33 of 102 (32.4%) in the antiplatelet group (difference, -20.0 percentage points; 95% CI, -30.9 to -8.5). In the main trial, the risk of death or thromboembolic events and the risk of life-threatening, disabling, or major bleeding were higher with rivaroxaban (hazard ratios of 1.35 and 1.50, respectively). CONCLUSIONS: In a substudy of a trial involving patients without an indication for long-term anticoagulation who had undergone successful TAVR, a rivaroxaban-based antithrombotic strategy was more effective than an antiplatelet-based strategy in preventing subclinical leaflet-motion abnormalities. However, in the main trial, the rivaroxaban-based strategy was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than the antiplatelet-based strategy. (Funded by Bayer; GALILEO-4D ClinicalTrials.gov number, NCT02833948.).


Assuntos
Valva Aórtica/fisiopatologia , Aspirina/farmacologia , Clopidogrel/farmacologia , Inibidores do Fator Xa/farmacologia , Próteses Valvulares Cardíacas , Inibidores da Agregação Plaquetária/farmacologia , Rivaroxabana/farmacologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/efeitos dos fármacos , Valva Aórtica/patologia , Aspirina/efeitos adversos , Aspirina/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Doenças Cardiovasculares/mortalidade , Clopidogrel/efeitos adversos , Clopidogrel/uso terapêutico , Quimioterapia Combinada , Inibidores do Fator Xa/efeitos adversos , Inibidores do Fator Xa/uso terapêutico , Feminino , Tomografia Computadorizada Quadridimensional , Hemorragia/induzido quimicamente , Humanos , Análise de Intenção de Tratamento , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Rivaroxabana/efeitos adversos , Rivaroxabana/uso terapêutico , Tromboembolia/etiologia , Tromboembolia/mortalidade
3.
Catheter Cardiovasc Interv ; 101(4): 787-797, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36740229

RESUMO

AIMS: Early healing after drug-eluting stent (DES) implantation may reduce the risk of stent thrombosis. The aim of this study was to compare patterns of early healing after implantation of the thin strut everolimus-eluting Synergy DES (Boston Scientific) or the biolimus-eluting Biomatix Neoflex DES (Biosensors). METHODS AND RESULTS: A total of 160 patients with the chronic or acute coronary syndrome were randomized 1:1 to Synergy or Biomatrix DES. Optical coherence tomography (OCT) was performed at baseline and at either 1- or 3-month follow-up. The primary endpoint was a coronary stent healing index (CSHI), a weighted index of strut coverage, neointimal hyperplasia, malapposition, and extrastent lumen. A total of 133 cases had OCT follow-up and 119 qualified for matched OCT analysis. The median CSHI score did neither differ significantly between the groups at 1 month: Synergy 8.0 (interquartile range [IQR]: 3.0; 14.0) versus Biomatrix 8.5 (IQR: 4.0; 15.0) (p = 0.47) nor at 3 months: Synergy 6.5 (IQR: 2.0; 13.0) versus Biomatrix 6.0 (IQR: 4.0; 11.0) (p = 0.83). Strut coverage was 84.6% (IQR: 72.0; 97.9) for Synergy versus 77.6% (IQR: 70.1; 90.3) for Biomatrix (p = 0.15) at 1 month and 90.3% (IQR 79.0; 98.8) (Synergy) versus 83.9% (IQR: 77.5; 92.6) (Biomatrix) (p = 0.068) at 3 months. Pooled 1- and 3-month coverage was 88.6% (IQR: 74.4; 98.4) for Synergy compared with 80.7% (IQR: 73.2; 90.8) for Biomatrix (p = 0.02). CONCLUSIONS: The early healing response after treatment with the Synergy or Biomatrix DES did not differ significantly as determined by a healing index. The Synergy DES showed overall better early stent strut coverage.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Everolimo , Doença da Artéria Coronariana/terapia , Polímeros , Implantes Absorvíveis , Resultado do Tratamento , Desenho de Prótese , Tomografia de Coerência Óptica
4.
Catheter Cardiovasc Interv ; 101(1): 13-21, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378691

RESUMO

OBJECTIVES: To compare the efficacy and safety of the dual-therapy CD34 antibody-covered sirolimus-eluting Combo stent (DTS) and the sirolimus-eluting Orsiro stent (O-SES) in patients with and without acute coronary syndrome (ACS) included in the SORT OUT X study. BACKGROUND: The incidence of target lesion failure (TLF) after treatment with modern drug-eluting stents has been reported to be significantly higher in patients with ACS when compared to patients without ACS. Whether the results from the SORT OUT X study apply to patients with and without ACS remains unknown. METHODS: In total, 3146 patients were randomized to stent implantation with DTS (n = 1578; ACS: n = 856) or O-SES (n = 1568; ACS: n = 854). The primary end point, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 1 year. RESULTS: At 1 year, the rate of TLF was higher in the DTS group compared to the O-SES group, both among patients with ACS (6.7% vs. 4.1%; incidence rate ratio: 1.65 [95% confidence interval, CI: 1.08-2.52]) and without ACS (6.0% vs. 3.2%; incidence rate ratio: 1.88 [95% CI: 1.13-3.14]). The differences were mainly explained by higher rates of TLR, whereas rates of cardiac death and target lesion MI did not differ significantly between the two stent groups in patients with or without ACS CONCLUSION: Compared to the O-SES, the DTS was associated with a higher risk of TLF at 12 months in patients with and without ACS. The differences were mainly explained by higher rates of TLR.


Assuntos
Síndrome Coronariana Aguda , Fármacos Cardiovasculares , Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Sirolimo/efeitos adversos , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/terapia , Síndrome Coronariana Aguda/complicações , Doença da Artéria Coronariana/terapia , Fatores de Risco , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Implantes Absorvíveis , Fármacos Cardiovasculares/efeitos adversos , Fatores de Tempo , Desenho de Prótese , Infarto do Miocárdio/etiologia , Stents Farmacológicos/efeitos adversos
5.
Circulation ; 143(22): 2155-2165, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33823606

RESUMO

BACKGROUND: Target lesion failure remains an issue with contemporary drug-eluting stents. Thus, the dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo stent (DTS) was designed to further improve early healing. This study aimed to investigate whether the DTS is noninferior to the sirolimus-eluting Orsiro stent (SES) in an all-comers patient population. METHODS: The SORT OUT X (Combo Stent Versus Orsiro Stent) trial, was a large-scale, randomized, multicenter, single-blind, 2-arm, noninferiority trial with registry-based follow-up. The primary end point target lesion failure was a composite of cardiac death, myocardial infarction, or target lesion revascularization within 12 months, analyzed using intention-to-treat. The trial was powered for assessing target lesion failure noninferiority of the DTS compared with the SES with a predetermined noninferiority margin of 0.021. RESULTS: A total of 3146 patients were randomized to treatment with the DTS (1578 patients; 2008 lesions) or SES (1568 patients; 1982 lesions). At 12 months, intention-to-treat analysis showed that 100 patients (6.3%) assigned the DTS and 58 patients (3.7%) assigned the SES met the primary end point (absolute risk difference, 2.6% [upper limit of 1-sided 95% CI, 4.1%]; P (noninferiority)=0.76). The SES was superior to the DTS (incidence rate ratios for target lesion failure, 1.74 [95% CI, 1.26-2.41]; P=0.00086). The difference was explained mainly by a higher incidence of target lesion revascularization in the DTS group compared with the SES group (53 [3.4%] vs. 24 [1.5%]; incidence rate ratio, 2.22 [95% CI, 1.37-3.61]; P=0.0012). CONCLUSIONS: The DTS did not confirm noninferiority to the SES for target lesion failure at 12 months in an all-comer population. The SES was superior to the DTS mainly because the DTS was associated with an increased risk of target lesion revascularization. However, rates of death, cardiac death, and myocardial infarction at 12 months did not differ significantly between the 2 stent groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03216733.


Assuntos
Antibacterianos/uso terapêutico , Antígenos CD34/metabolismo , Stents Farmacológicos/normas , Intervenção Coronária Percutânea/métodos , Sirolimo/uso terapêutico , Idoso , Antibacterianos/farmacologia , Feminino , Humanos , Masculino , Sirolimo/farmacologia , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 99(7): 1965-1975, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35384254

RESUMO

OBJECTIVES: To compare the efficacy and safety of the dual therapy CD34 antibody-covered sirolimus-eluting Combo stent (DTS) and the sirolimus-eluting Orsiro stent (SES) in patients with and without diabetes mellitus (DM) included in the Scandinavian Organization for Randomized Trials with Clinical Outcome (SORT OUT) X study. BACKGROUND: The incidence of target lesion failure (TLF) after treatment with modern drug-eluting stents has been reported to be significantly higher in patients with DM when compared to patients without DM. Thus, whether the results from the SORT OUT X study apply to patients with and without DM remains unknown. METHODS: In total 3146 patients were randomized to stent implantation with DTS (n = 1578; DM: n = 279) or SES (n = 1568; DM: n = 271). The primary end point, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 1 year. RESULTS: At 1 year, the rate of TLF was increased in the DTS group compared to the SES group, both among patients with DM (9.3% vs. 4.8%; risk difference: 4.5%; incidence rate ratio: 1.99, 95% confidence interval [CI]: 1.02-3.90) and without DM (5.7% vs. 3.5%; incidence rate ratio: 1.67, 95% CI: 1.15-2.42). The differences were mainly explained by higher rates of TLR. CONCLUSION: Compared to the SES, the DTS was associated with an increased risk of TLF at 12 months in patients with and without DM. The differences were mainly explained by higher rates of TLR, whereas rates of cardiac death and target lesion MI did not differ significantly between the two stent groups in patients with or without DM.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Infarto do Miocárdio , Intervenção Coronária Percutânea , Implantes Absorvíveis , Antígenos CD34/imunologia , Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/terapia , Morte , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Humanos , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Sirolimo/efeitos adversos , Stents , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 97(6): 1270-1278, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33347739

RESUMO

OBJECTIVES: To study safety and performance of the MANTA Vascular closure device (VCD) under real world conditions in 10 centers. BACKGROUND: The MANTA is a novel plug-based device for large bore arteriotomy closure. METHODS: We included all eligible patients who underwent transfemoral large bore percutaneous procedures. Exclusion criteria were per operator's discretion and included severe calcification or marked tortuosity of the access vessel, presence of marked obesity/cachexia or a systolic blood pressure above 180 mmHg. The primary performance endpoint was time to hemostasis. Primary and secondary safety endpoints were major and minor access site related vascular complications up to 30 days, respectively. Vascular complications were adjudicated by an independent clinical event committee according to VARC-2 criteria. We performed multivariable logistic regression to estimate the effect of baseline and procedural characteristics on any and major vascular complications. RESULTS: Between February 2018 and July 2019 500 patients were enrolled undergoing Transcatheter aortic valve replacement (TAVR, N = 496), Balloon aortic valvuloplasty (BAV, N = 2), Mechanical circulatory support (MCS, N = 1) or Endovascular aneurysm repair (EVAR, N = 1). Mean age was 80.8 ± 6.6 years with a median STS-score of 2.7 [IQR 2.0-4.3] %. MANTA access site complications were major in 20 (4%) and minor in 28 patients (5.6%). Median time to hemostasis was 50 [IQR 20-120] sec. Severe femoral artery calcification, scar presence in groin, longer procedure duration, female gender and history of hypertension were independent predictors for vascular complications. CONCLUSION: In this study, MANTA appeared to be a safe and effective device for large bore access closure under real-world conditions.


Assuntos
Aneurisma da Aorta Abdominal , Estenose da Valva Aórtica , Implante de Prótese Vascular , Cateterismo Periférico , Procedimentos Endovasculares , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Cateterismo Periférico/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Humanos , Sistema de Registros , Resultado do Tratamento
8.
Acta Anaesthesiol Scand ; 65(7): 936-943, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33728635

RESUMO

BACKGROUND: Veno-arterial extracorporeal membrane oxygenation (V-A ECMO) is commonly used to provide haemodynamic support for patients with severe cardiac failure. However, timing ECMO weaning remains challenging. We aimed to examine if an integrative weaning approach based on predefined haemodynamic, respiratory and echocardiographic criteria is associated with successful weaning. METHODS: All patients weaned from ECMO between April 2017 and April 2019 at Aarhus University Hospital, Denmark, were consecutively enrolled. Predefined haemodynamic, respiratory and echocardiographic criteria were assessed before and during ECMO flow reduction. A weaning attempt was commenced in haemodynamic stable patients and patients remaining stable at minimal flow were weaned from ECMO. Comparisons were made between patients who met the criteria for weaning at first attempt and patients who did not meet these criteria. Patients completing a full weaning attempt with no further need for mechanical support within 24 h were defined as successfully weaned. RESULTS: A total of 38 patients were included in the study, of whom 26 (68%) patients met the criteria for weaning. Among these patients, 25 (96%) could be successfully weaned. Successfully weaned patients were younger and had less need for inotropic support and ECMO duration was shorter. Fulfilling the weaning criteria was associated with successful weaning and both favourable 30-d survival and survival to discharge. CONCLUSION: An integrative weaning approach based on haemodynamic, respiratory and echocardiographic criteria may strengthen the clinical decision process in predicting successful weaning in patients receiving ECMO for refractory cardiac failure.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Ecocardiografia , Insuficiência Cardíaca/terapia , Hemodinâmica , Humanos , Estudos Retrospectivos
9.
Am Heart J ; 202: 49-53, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29807307

RESUMO

BACKGROUND: The Combo stent (OrbusNeich, Hoevelaken, the Netherlands) combining an abluminal, bioabsorbable polymer eluting sirolimus with a luminal CD34+ antibody to capture endothelial progenitor cells has been developed to further improve safety and efficacy of coronary interventions. We have designed a large-scale registry-based randomized clinical trial to compare the Combo stent to the Orsiro stent (Biotronik, Bülach, Switzerland) in patients undergoing percutaneous coronary intervention. METHODS: The SORT OUT X study will randomly assign 3,140 patients to treatment with Combo or Orsiro stents at 3 sites in Western Denmark. Patients are eligible if they are ≥18 years old, have chronic stable coronary artery disease or acute coronary syndromes, and have ≥1 coronary lesion with >50% diameter stenosis requiring treatment with a drug-eluting stent. The primary end point target lesion failure is a composite of cardiac death, myocardial infarction (not related to other than index lesion), or target lesion revascularization within 12 months. Clinically driven event detection will be derived from validated Danish registries. An event rate of 4.2% is assumed in each stent group. With a sample size of 1,570 patients in each treatment arm, a 2-group large-sample normal approximation test of proportions with a 1-sided 5% significance level will have 90% power to detect noninferiority of the Combo stent compared with the Orsiro stent with a predetermined noninferiority margin of 2.1%. CONCLUSION: The SORT OUT X trial will determine whether the dual-therapy Combo stent is noninferior to the Orsiro stent with respect to clinically driven events (ClinicalTrials.govNCT03216733).


Assuntos
Síndrome Coronariana Aguda/terapia , Antígenos CD34/imunologia , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea , Sirolimo/administração & dosagem , Adulto , Anticorpos , Materiais Revestidos Biocompatíveis , Feminino , Humanos , Masculino , Desenho de Prótese , Sistema de Registros , Projetos de Pesquisa , Método Simples-Cego
10.
Lancet ; 387(10034): 2199-206, 2016 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-27053444

RESUMO

BACKGROUND: Despite successful treatment of the culprit artery lesion by primary percutaneous coronary intervention (PCI) with stent implantation, thrombotic embolisation occurs in some cases, which impairs the prognosis of patients with ST-segment elevation myocardial infarction (STEMI). We aimed to assess the clinical outcomes of deferred stent implantation versus standard PCI in patients with STEMI. METHODS: We did this open-label, randomised controlled trial at four primary PCI centres in Denmark. Eligible patients (aged >18 years) had acute onset symptoms lasting 12 h or less, and ST-segment elevation of 0·1 mV or more in at least two or more contiguous electrocardiographic leads or newly developed left bundle branch block. Patients were randomly assigned (1:1), via an electronic web-based system with permuted block sizes of two to six, to receive either standard primary PCI with immediate stent implantation or deferred stent implantation 48 h after the index procedure if a stabilised flow could be obtained in the infarct-related artery. The primary endpoint was a composite of all-cause mortality, hospital admission for heart failure, recurrent infarction, and any unplanned revascularisation of the target vessel within 2 years' follow-up. Patients, investigators, and treating clinicians were not masked to treatment allocation. We did analysis by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT01435408. FINDINGS: Between March 1, 2011, and Feb 28, 2014, we randomly assigned 1215 patients to receive either standard PCI (n=612) or deferred stent implantation (n=603). Median follow-up time was 42 months (IQR 33-49). Events comprising the primary endpoint occurred in 109 (18%) patients who had standard PCI and in 105 (17%) patients who had deferred stent implantation (hazard ratio 0·99, 95% CI 0·76-1·29; p=0·92). Procedure-related myocardial infarction, bleeding requiring transfusion or surgery, contrast-induced nephopathy, or stroke occurred in 28 (5%) patients in the conventional PCI group versus 27 (4%) patients in the deferred stent implantation group, with no significant differences between groups. INTERPRETATION: In patients with STEMI, routine deferred stent implantation did not reduce the occurrence of death, heart failure, myocardial infarction, or repeat revascularisation compared with conventional PCI. Results from ongoing randomised trials might shed further light on the concept of deferred stenting in this patient population. FUNDING: Danish Agency for Science, Technology and Innovation, and Danish Council for Strategic Research.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/métodos , Antagonistas Adrenérgicos beta/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Bloqueadores dos Canais de Cálcio/administração & dosagem , Feminino , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/administração & dosagem , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/administração & dosagem
11.
Biomarkers ; 22(3-4): 351-360, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27903076

RESUMO

PURPOSE: In patients with a suspected acute myocardial infarction (AMI), to evaluate the potential for early triage based on measurement of high-sensitivity cardiac troponin T (hs-cTnT) and copeptin in blood samples collected in the prehospital phase. MATERIALS AND METHODS: In this retrospective study, we measured hs-cTnT and copeptin in blood samples collected in the ambulance form 962 patients with suspected AMI. The diagnostic accuracy was estimated by receiver-operating characteristic (ROC) curve area under the curve (AUC) for both biomarkers and a combined model. Multivariable Cox regression modelling was used to estimate the predictive value of both biomarkers. RESULTS: In total, 178 (19%) cases had AMI. The AUC for hs-cTnT was 0.81. Adding copeptin increased the AUC to 0.85 (p = 0.004) and the combined model allowed a prehospital rule-out of 45% of cases without AMI (negative predictive value, NPV 98%). Both biomarkers are highly predictive of outcome. CONCLUSIONS: A future application of hs-cTnT and copeptin measurement, performed already in the prehospital phase, could potentially improve the prehospital diagnostic and prognostic classification of patients with a suspected AMI.


Assuntos
Glicopeptídeos/sangue , Infarto do Miocárdio/diagnóstico , Troponina T/sangue , Idoso , Área Sob a Curva , Biomarcadores/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Resultado do Tratamento
12.
Ann Emerg Med ; 70(3): 366-373.e3, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28347554

RESUMO

STUDY OBJECTIVE: Emergency medical services (EMS) provides out-of-hospital care to patients with life-threatening conditions, but the long-term outcomes of EMS patients are unknown. We seek to determine the long-term mortality of EMS patients in Denmark. METHODS: We analyzed linked EMS, hospital, and vital status data from 3 of 5 geographic regions in Denmark. We included events from July 1, 2011, to December 31, 2012. We classified EMS events according to primary dispatch category (unconsciousness/cardiac arrest, accidents/trauma, chest pain, dyspnea, neurologic symptoms, and other EMS patients). The primary outcome was 1-year mortality adjusted for age, sex, and Charlson comorbidity index. RESULTS: Among 142,125 EMS events, primary dispatch categories were unconsciousness or cardiac arrest 5,563 (3.9%), accidents or trauma 40,784 (28.7%), chest pain 20,945 (14.7%), dyspnea 9,607 (6.8%), neurologic symptoms 17,804 (12.5%), and other EMS patients 47,422 (33.4%). One-year mortality rates were unconscious or cardiac arrest 54.7% (95% confidence interval [CI] 53.4% to 56.1%), accidents or trauma 7.8 (95% CI 7.5% to 8.1%), chest pain 8.5% (95% CI 8.1% to 9.0%), dyspnea 27.7% (95% CI 26.7% to 28.7%), neurologic symptoms 14.1% (95% CI 13.6% to 14.7%), and other EMS patients 11.1% (95% CI 10.8% to 11.4%). Compared with other EMS conditions, adjusted 1-year mortality was higher in unconsciousness or cardiac arrest (risk ratio [RR] 2.6; 95% CI 2.5 to 2.7), dyspnea (RR 1.5; 95% CI 1.4 to 1.5), and in neurologic symptoms (RR 1.1; 95% CI 1.0 to 1.1), but lower in chest pain (RR 0.6; 95% CI 0.6 to 0.7) and accidents or trauma (RR 0.8; 95% CI 0.8 to 0.8). CONCLUSION: EMS patients with unconsciousness or cardiac arrest, dyspnea, and neurologic symptoms are at highest risk of long-term mortality. Our results suggest a potential for outcome improvement in these patients.


Assuntos
Reanimação Cardiopulmonar/mortalidade , Dispneia/mortalidade , Serviços Médicos de Emergência/organização & administração , Doenças do Sistema Nervoso/mortalidade , Parada Cardíaca Extra-Hospitalar/mortalidade , Programas Médicos Regionais/organização & administração , Inconsciência/mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Dinamarca/epidemiologia , Serviços Médicos de Emergência/estatística & dados numéricos , Feminino , Pesquisas sobre Atenção à Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Programas Médicos Regionais/estatística & dados numéricos , Fatores de Tempo , Resultado do Tratamento
13.
J Electrocardiol ; 47(4): 540-5, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24878032

RESUMO

In patients with ST-elevation myocardial infarction (STEMI) the amount of myocardial area at risk (MaR) indicates the maximal potential loss of myocardium if the coronary artery remains occluded. During the time course of infarct evolution ischemic MaR is replaced by necrosis, which results in a decrease in ST segment elevation and QRS complex distortion. Recently it has been shown that combining the electrocardiographic (ECG) Aldrich ST and Selvester QRS scores result in a more accurate estimate of MaR than using either method alone. Therefore, we hypothesized that the combined Aldrich and Selvester score, indicating MaR, is stable until myocardial reperfusion therapy. In a retrospective analysis of a study population of 114 patients, 33 patients were included. The combined Aldrich and Selvester score was determined in ECGs recorded in the ambulance (ECG1) and in the hospital before reperfusion (ECG2). The combined Aldrich and Selvester score was considered stable if the difference between ECG1 and ECG2 was <4.5-percentage point. Stability of the combined Aldrich and Selvester score was observed in 12/33 patients (36.4%), and in regards to anterior and inferior ST elevation in 4/14 patients (28.6%) and 8/19 patients (42.1%), respectively. The median time between the recording of ECG1 and ECG2 was 75 minutes, however the changes in ECG scores were independent of the time between ECG recordings. Patients not meeting the stability criterion either had a decrease (9 patients) or increase (12 patients) of the combined Aldrich and Selvester score. In conclusion, the ECG estimated MaR was stable between the earliest recording time and initiation of reperfusion treatment only in a subgroup of the patients with STEMI. The findings of this study may suggest heterogeneity in regards to the development of the MaR and could indicate a potential need for differentiation in the acute treatment.


Assuntos
Eletrocardiografia/métodos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Miocárdio Atordoado/diagnóstico , Miocárdio Atordoado/etiologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco/métodos , Sensibilidade e Especificidade
14.
Am J Cardiol ; 211: 299-306, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37984636

RESUMO

With increased use of transcatheter aortic valve implantation (TAVI) in treatment of aortic stenosis, it is important to evaluate real life data trends in outcomes. This nationwide register-based study aimed to present an outlook on temporal trends in characteristics and outcomes, including mortality. First-time consecutive Danish patients who underwent TAVI from 2010 to 2019 were included in this study. The chi-square and Kruskal-Wallis tests were performed to assess the differences in the characteristics over time and Cochrane-Armitage trend tests were used to examine changes in complications and mortality. Between 2010 and 2019, 4,847 patients (54.6% men, median age 82 [quartile 1 to quartile 3: 77 to 85] years) underwent first-time TAVI. A statistically significant decrease over time was observed for preprocedural hypertension, ischemic heart disease, and heart failure, whereas preexisting chronic obstructive lung disease and preprocedural pacemaker remained stable. We observed a significant decrease in 30- and 90-day postoperative preprocedural pacemaker implantation from 2011 to 2017, with 15.1% and 15.9% in 2011 and 8.6% and 8.9% in 2017, respectively. The incidence of for 30- and 90-day heart failure significantly decreased from 19.3% and 20.3% to 8.5% and 9.1%, respectively. We observed significant changes for 30-day atrial fibrillation, whereas the changes over time for 90-day atrial fibrillation and 30- and 90-day stroke/transient ischemic attack remained insignificant. The all-cause mortality within 30- and 90 days significantly decreased over time from 6.7% and 9.2% in 2011 to 1.5% and 2.7% in 2019 and 2016, respectively. In conclusion, this national study provides general insight on the trends of complications and mortality of TAVI, demonstrating significant reductions over time.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/cirurgia , Fibrilação Atrial/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Estenose da Valva Aórtica/cirurgia , Insuficiência Cardíaca/cirurgia , Resultado do Tratamento , Fatores de Risco
15.
J Electrocardiol ; 46(3): 215-20, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23561836

RESUMO

BACKGROUND: The myocardial area at risk (MaR) has been estimated in patients with acute myocardial infarction (AMI) by using ST segment based ECG methods. However, as the process from ischemia to infarction progresses, the ST segment deviation is typically replaced by QRS abnormalities, causing a falsely low estimation of the total MaR if determined by using ST segment based methods. A previous study showed the value of the consideration of the abnormalities in the QRS complex, in addition to those in the ST segment estimating the total MaR for patients with anterior AMI. The purpose of this study was to investigate the same method for patients with inferior AMI. METHODS: Thirty-two patients with acute inferior ST elevation myocardial infarction received (99m)Tc-Sestamibi before percutaneous coronary intervention. SPECT was performed within 2 hours after treatment and was used as a gold standard for the estimation of the total MaR. The ECG recorded at admission in the hospital was used for the ECG estimates of the total MaR. This included a ST segment estimation of the ischemic component of the total MaR (Aldrich score) and an estimation of the infarcted component of the total MaR in the acute phase of AMI by QRS abnormalities (Selvester score). These scores were added for the combined ECG score. RESULTS: The ischemic component of the total MaR estimated by the Aldrich score alone no statistically significant correlation with SPECT (r=0.17, p=0.36). The infarcted component of the total MaR estimated by the Selvester score showed a significant correlation with SPECT (r=0.55, p=0.001). When the Aldrich and Selvester scores were combined, the correlation with SPECT improved (r=0.58, p<0.001). Both the Aldrich and Selvester score alone underestimated the mean MaR measured by SPECT (respectively p=0.007 and p<0.0001). There was no statistically significant difference between the mean MaR estimated by the sum of Aldrich and Selvester and the MaR measured by SPECT (p=0.636). CONCLUSION: The estimation of the total MaR was more accurate by taking both ST deviation and QRS abnormalities in account than by using either method alone. A new ECG method to determine the total MaR during acute coronary occlusion should consider both its ischemic and infarcted components.


Assuntos
Algoritmos , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Infarto do Miocárdio/diagnóstico , Reconhecimento Automatizado de Padrão/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade
16.
EuroIntervention ; 19(8): 676-683, 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37584207

RESUMO

BACKGROUND: Target lesion failure (TLF) remains an issue with contemporary drug-eluting stents. The dual-therapy sirolimus-eluting and CD34 antibody-coated COMBO stent (DTS) was designed to improve early healing. AIMS: We aimed to compare the 3-year outcomes of the DTS and the sirolimus-eluting Orsiro stent (SES) in all-comer patients treated with percutaneous coronary intervention. METHODS: The SORT OUT X trial is a prospective multicentre randomised clinical trial with a registry-based follow-up comparing DTS and SES. The primary endpoint, TLF, is a composite of cardiac death, myocardial infarction or target lesion revascularisation (TLR). RESULTS: A total of 3,146 patients were randomised to treatment with the DTS (1,578 patients) or the SES (1,568 patients). At 3 years, an intention-to-treat analysis showed that 155 patients (9.8%) who were assigned the DTS and 118 patients (7.5%) who were assigned the SES met the primary endpoint (incidence rate ratio for TLF=1.33, 95% confidence interval: 1.04-1.70; p=0.02). This difference was caused by a significantly higher TLF rate in the DTS group compared to the SES group within the first year, which was mainly explained by a higher incidence of TLR in the DTS group compared to the SES group. Of note, the TLF rates were almost identical from 1 year to 3 years in both stent groups. CONCLUSIONS: At 3 years, the SES was superior to the DTS, mainly because the DTS was associated with an increased risk of TLF within the first year but not from 1 to 3 years. CLINICALTRIALS: gov: NCT03216733.

17.
Eur Heart J Qual Care Clin Outcomes ; 9(5): 529-536, 2023 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-36195332

RESUMO

AIMS: Standardized data definitions are necessary for the quantification of quality of care and patient outcomes in observational studies and randomised controlled trials (RCTs). The European Unified Registries for Heart Care Evaluation and Randomised Trials (EuroHeart) project of the European Society of Cardiology (ESC) aims to create pan-European data standards for cardiovascular diseases and interventions, including transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: We followed the EuroHeart methodology for cardiovascular data standard development. A Working Group of 29 members representing 12 countries was established and included a patient representative, as well as experts in the management of valvular heart disease from the European Association of Percutaneous Cardiovascular Interventions (EAPCI), the European Association of Cardiovascular Imaging (EACVI) and the Working Group on Cardiovascular Surgery. We conducted a systematic review of the literature and used a modified Delphi method to reach consensus on a final set of variables. For each variable, the Working Group provided a definition, permissible values, and categorized the variable as mandatory (Level 1) or additional (Level 2) based on its clinical importance and feasibility. In total, 93 Level 1 and 113 Level 2 variables were selected, with the level 1 variables providing the dataset for registration of patients undergoing TAVI on the EuroHeart IT platform. CONCLUSION: This document provides details of the EuroHeart data standards for TAVI processes of care and in-hospital outcomes. In the context of EuroHeart, this will facilitate quality improvement, observational research, registry-based RCTs and post-marketing surveillance of devices, and pharmacotherapies. ONE-SENTENCE SUMMARY: The EuroHeart data standards for transcatheter aortic valve implantation (TAVI) are a set of internationally agreed data variables and definitions that once implemented will facilitate improvement of quality of care and outcomes for patients receiving TAVI.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Sistema de Registros , Ensaios Clínicos Controlados Aleatórios como Assunto
18.
Front Cardiovasc Med ; 10: 1161779, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37529710

RESUMO

Paravalvular leak (PVL) is a shortcoming that can erode the clinical benefits of transcatheter valve replacement (TAVR) and therefore a readily applicable method (aortography) to quantitate PVL objectively and accurately in the interventional suite is appealing to all operators. The ratio between the areas of the time-density curves in the aorta and left ventricular outflow tract (LVOT-AR) defines the regurgitation fraction (RF). This technique has been validated in a mock circulation; a single injection in diastole was further tested in porcine and ovine models. In the clinical setting, LVOT-AR was compared with trans-thoracic and trans-oesophageal echocardiography and cardiac magnetic resonance imaging. LVOT-AR > 17% discriminates mild from moderate aortic regurgitation on echocardiography and confers a poor prognosis in multiple registries, and justifies balloon post-dilatation. The LVOT-AR differentiates the individual performances of many old and novel devices and is being used in ongoing randomized trials and registries.

19.
Front Cardiovasc Med ; 9: 1045280, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36505358

RESUMO

Transcatheter aortic valve replacement (TAVR) is a recommended intervention for selected population with severe aortic stenosis (AS). Bicuspid aortic valve (BAV) anatomy has been categorized as an unfavorable anatomy for TAVR due to multiple considerations as exclusion from randomized trials in addition to the challenging and unpredictable anatomy. The anatomical constraints of BAV include the large anatomy of the annulus, sinus of Valsalva, and aorta (aortopathy), in addition to significant calcifications of the device landing zone. Most commercial transcatheter heart valves (THV) have upper dimension limits of the annulus and area in which the device can be implanted safely without significant oversizing. Myval-XL THVs (Meril Life Sciences Pvt. Ltd., India) are balloon-expandable valves (BEV) that have been developed with two new sizes, 30.5 and 32 mm, aiming to treat patients with large annulus dimensions and that exceed the upper limit of an ordinary device's sizing matrix. This case series report describes TAVR using the XL-Myval 32 mm THV in three European patients with symptomatic severe bicuspid aortic stenosis with significant calcifications and large annular dimensions exceeding the limits of the other THVs.

20.
Coron Artery Dis ; 33(3): 196-205, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-34985003

RESUMO

OBJECTIVE: To evaluate the difference in early vascular healing between the ultrathin-strut biodegradable-polymer sirolimus-eluting Orsiro stent (O-SES) and the polymer-free biolimus-A9-eluting BioFreedom stent (BF-BES), assessed with optical coherence tomography (OCT) after primary percutaneous coronary intervention (PCI) in patients with ST-segment elevation myocardial infarctions (STEMIs). METHODS: Eighty patients with STEMI who underwent primary PCI were randomly allocated 1:1 to treatment with BF-BES or O-SES. OCT was acquired after PCI and at 1-month follow-up. The primary endpoint was 1-month OCT-assessed vascular healing index based on the presence of uncovered and malapposed stent struts and intraluminal filling defects where low vascular healing index indicated favorable vascular healing. RESULTS: At 1-month, the vascular healing index was similar in O-SES 11.5 [interquartile range (IQR) 9.5-17.5], compared to BF-BES 11.5 (IQR 7.1-12.5; P = 0.14). Percentage of uncovered struts [O-SES 31.5% (IQR 20.7-41.9), P = 0.43] vs. BF-BES 27.8% (IQR 19.4-41.9; P = 0.44), and median volume of neointimal hyperplasia [O-SES 4.9 mm3 (IQR 1.4-13.1) vs. BF-BES 7.1 mm3 (IQR 2.8-17.0), P = 0.18] did not differ significantly between the two stent groups. Complete coverage was not observed in any of the stents. The percentages of stents with malapposition did not differ significantly (O-SES 87.1% vs. BF-BES 71.4%, P = 0.14) whereas percentage of malapposed struts [O-SES 3.5% (IQR 0.8-5.5) vs. BF-BES 0.8% (IQR 0.0-1.8), P = 0.003] was lower in the BF-BES group. CONCLUSION: In patients with STEMI, the drug-coated BF-BES and the thin strut O-SES had similar vascular healing index at 1-month. However, the thin O-SES struts were more often malapposed.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Implantes Absorvíveis , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Polímeros , Desenho de Prótese , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Sirolimo , Stents , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA