1.
Artigo em Inglês | MEDLINE | ID: mdl-27572179

RESUMO

AIMS: Strict left bundle branch block (LBBB) criteria were recently proposed to identify LBBB patients to benefit most from cardiac resynchronization therapy (CRT). The aim of our study was to automate identification of strict LBBB in order to facilitate its broader application. METHODS: We developed a series of algorithms to automatically detect and measure parameters required for strict LBBB criteria and proposed a definition of QRS notch detection. The algorithms were developed using training (n = 20) and validation (n = 592) sets consisting of signal-averaged 12-lead ECGs (1,000 Hz sampling) recorded from 612 LBBB patients from Multicenter Automatic Defibrillator Implantation Trial-CRT. Four trained clinicians independently performed adjudication on 148 different ECGs for comparing automatic and manually adjudicated results, in addition to 13 ECGs for evaluation of intraobserver variability and 32 ECGs for interobserver variability. We assessed the performance of the automated algorithms using manually adjudicated ECGs as references. RESULTS: Overall sensitivity and specificity for detecting strict LBBB were 95% and 86%, respectively. The mean absolute deviation (MAD) of QRS duration and notch/slur locations for the automated method versus the manual method was below 1 ms, and MAD values were lower than 2 ms for interobserver and intraobserver variability. Sensitivity and specificity for detecting notch and slur locations were 87% and 96% for notches and 78% and 90% for slurs using the automatic method. In addition 95% and 93% agreements for notches and 90% and 88% agreements for slurs were reached for intra- and interobserver. CONCLUSION: The proposed algorithms automatically measure QRS features for the diagnosis of strict LBBB. Our study shows good performance in reference to manual results.


Assuntos
Bloqueio de Ramo/diagnóstico , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
2.
Europace ; 14(10): 1475-82, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22447958

RESUMO

AIMS: Previous studies indicate that ventricular pacing may precipitate heart failure (HF). We investigated occurrence of HF during long-term follow-up among patients with sick sinus syndrome (SSS) randomized to AAIR or DDDR pacing. Furthermore, we investigated effects of percentage of ventricular pacing (%VP) and pacing site in the ventricle. METHODS AND RESULTS: We analysed data from 1415 patients randomized to AAIR (n = 707) or DDDR pacing (n = 708). Ventricular pacing leads were recorded as located in either an apical or a non-apical position. The %VP and HF hospitalizations were recorded during follow-up. Patients were classified with new HF, if in New York Heart Association (NYHA) functional class IV or if presence of ≥2 of: oedema; dyspnoea; NYHA functional class III. Mean follow-up was 5.4 ± 2.4 years. Heart failure hospitalizations did not differ between groups. In the AAIR group, 170 of the 707 (26%) patients developed HF vs. 169 of the 708 (26%) patients in the DDDR group, hazard rate ratio (HR) 1.00, 95% confidence interval (CI) 0.79-1.22, P = 0.87. In DDDR patients, 146 of the 512 patients (29%) with ventricular leads in an apical position developed HF vs. 28 of the 161 patients (17%) with the leads in a non-apical position, HR 0.67, CI 0.45-1.00, P = 0.05. After adjustments this difference was non-significant. The incidence of HF was not associated with %VP (P = 0.57). CONCLUSION: In patients with SSS, HF was not associated with pacing mode, %VP, or ventricular lead localization. This suggests that DDDR pacing is safe in patients with SSS without precipitating HF.


Assuntos
Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Insuficiência Cardíaca/etiologia , Síndrome do Nó Sinusal/terapia , Idoso , Idoso de 80 Anos ou mais , Dispneia/diagnóstico , Edema/diagnóstico , Feminino , Seguimentos , Insuficiência Cardíaca/epidemiologia , Hospitalização/estatística & dados numéricos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Ensaios Clínicos Controlados Aleatórios como Assunto , Índice de Gravidade de Doença , Resultado do Tratamento
3.
Europace ; 14(5): 682-9, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22106360

RESUMO

AIMS: In the recently published DANPACE trial, incidence of atrial fibrillation (AF) was significantly higher with single-lead atrial (AAIR) pacing than with dual-chamber (DDDR) pacing. The present analysis aimed to evaluate the importance of baseline PQ-interval and percentage of ventricular pacing (VP) on AF. METHODS AND RESULTS: We analysed data on AF during follow-up in 1415 patients included in the DANPACE trial. In a subgroup of 650 patients with DDDR pacemaker, we studied whether %VP, baseline PQ-interval, and programmed atrio-ventricular interval (AVI) was associated with AF burden measured as time in mode-switch (MS) detected by the pacemaker. In the entire DANPACE study population, the incidence of AF was significantly higher in patients with baseline PQ-interval >180 ms (P< 0.001). Among 650 patients with DDDR pacemaker, telemetry data were available for 1.337 ± 786 days, %VP was 66 ± 33%, AF was detected at planned follow-up in 160 patients (24.6%), MS occurred in 422 patients (64.9%), and AF burden was marginally higher with baseline PQ-interval >180 ms (P= 0.028). No significant association was detected between %VP and %MS (Spearman's ρ 0.056, P= 0.154). %MS was not different between minimal-paced programmed AVI ≤ 100 and >100 ms (median value), respectively (P= 0.60). CONCLUSIONS: The present study indicates that a longer baseline PQ-interval is associated with an increased risk of AF in patients with sick sinus syndrome. Atrial fibrillation burden is not associated with the percentage of VP or the length of the programmed AVI.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial/métodos , Estimulação Cardíaca Artificial/estatística & dados numéricos , Síndrome do Nó Sinusal/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Fibrilação Atrial/diagnóstico , Bradicardia/diagnóstico , Bradicardia/epidemiologia , Bradicardia/terapia , Eletrocardiografia , Feminino , Seguimentos , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Sensibilidade e Especificidade , Síndrome do Nó Sinusal/diagnóstico , Telemetria/estatística & dados numéricos
4.
Eur Heart J ; 32(6): 686-96, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21300730

RESUMO

AIMS: In patients with sick sinus syndrome, bradycardia can be treated with a single-lead pacemaker or a dual-chamber pacemaker. Previous trials have revealed that pacing modes preserving atrio-ventricular synchrony are superior to single-lead ventricular pacing, but it remains unclear if there is any difference between single-lead atrial pacing (AAIR) and dual-chamber pacing (DDDR). METHODS AND RESULTS: We randomly assigned 1415 patients referred for first pacemaker implantation to AAIR (n = 707) or DDDR (n = 708) pacing and followed them for a mean of 5.4 ± 2.6 years. The primary outcome was death from any cause. Secondary outcomes included paroxysmal and chronic atrial fibrillation, stroke, heart failure, and need for pacemaker reoperation. In the AAIR group, 209 patients (29.6%) died during follow-up vs. 193 patients (27.3%) in the DDDR group, hazard ratio (HR) 1.06, 95% confidence interval (CI) 0.88-1.29, P = 0.53. Paroxysmal atrial fibrillation was observed in 201 patients (28.4%) in the AAIR group vs. 163 patients (23.0%) in the DDDR group, HR 1.27, 95% CI 1.03-1.56, P = 0.024. A total of 240 patients underwent one or more pacemaker reoperations during follow-up, 156 (22.1%) in the AAIR group vs. 84 (11.9%) in the DDDR group (HR 1.99, 95% CI 1.53-2.59, P < 0.001). The incidence of chronic atrial fibrillation, stroke, and heart failure did not differ between treatment groups. CONCLUSION: In patients with sick sinus syndrome, there is no statistically significant difference in death from any cause between AAIR pacing and DDDR pacing. AAIR pacing is associated with a higher incidence of paroxysmal atrial fibrillation and a two-fold increased risk of pacemaker reoperation. These findings support the routine use of DDDR pacing in these patients. CLINICAL TRIAL REGISTRATION: URL http://www.clinicaltrials.gov. Unique identifier: NCT00236158.


Assuntos
Estimulação Cardíaca Artificial/métodos , Marca-Passo Artificial , Síndrome do Nó Sinusal/terapia , Adolescente , Adulto , Idoso , Fibrilação Atrial/etiologia , Fibrilação Atrial/mortalidade , Cardiotônicos/uso terapêutico , Causas de Morte , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação/estatística & dados numéricos , Síndrome do Nó Sinusal/mortalidade , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Resultado do Tratamento , Adulto Jovem