Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Dig Endosc ; 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39162053

RESUMO

In recent years, the usefulness of endoscopic ultrasound (EUS) has been recognized in children. A dedicated pediatric EUS scope has not been developed; in our experience, however, an adult EUS scope can be used. The American Society for Gastrointestinal Endoscopy Technical Committee status assessment report on pediatric endoscopy equipment provides some guidance on the feasibility of EUS according to body size. Careful monitoring is required, keeping in mind potential adverse events such as cervical esophageal perforation and unstable breathing due to tracheal compression. Most devices designed for interventional pancreatobiliary endoscopy are also available for children. Sedation or intubated general anesthesia (GA) is mandatory when performing interventional EUS (I-EUS). I-EUS for children is generally performed using GA in the operating room, but sedation in the endoscopy room is also possible under appropriate monitoring by pediatricians. I-EUS in the operating room is sometimes difficult for endoscopists to perform because of the unsuitable fluoroscopic imaging and the lack of familiar equipment and staff. Compared to GA, sedation in the endoscopy room facilitates easier and quicker repetition of procedures when necessary. Adult pancreatobiliary endoscopists perform most I-EUS procedures in the pediatric population because most pediatric endoscopists have few opportunities to perform EUS-related procedures and thus have difficulty maintaining their skills. To popularize I-EUS techniques for children, it will be necessary to establish a training program for developing pediatric endoscopists.

5.
J Clin Med ; 13(10)2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38792381

RESUMO

Background/Objective: Interventional endoscopic ultrasound (I-EUS) is technically difficult and has risks of severe adverse events due to the scarcity of dedicated endoscopes and tools. A new EUS scope was developed for I-EUS and was modified to increase the puncture range, reduce the blind area, and overcome guidewire difficulties. We evaluated the usefulness and safety of a new EUS scope compared to a conventional EUS scope. Methods: All I-EUS procedures were performed at Juntendo University Hospital from April 2020 to April 2022. The primary outcomes included the procedure time and fluoroscopy time. The secondary outcomes included the technical success rate and the rates of procedure-related adverse events. Clinical data were retrospectively reviewed and statistically analyzed between the new and conventional EUS scopes. Results: In total, 143 procedures in 120 patients were analyzed. The procedure time was significantly shorter with the new EUS scope, but the fluoroscopy time was not different. Among the patients only undergoing EUS-guided biliary drainage (EUS-BD), 79 procedures in 74 patients were analyzed. Both the procedure time and fluoroscopy time were significantly shorter with the new EUS scope. Multivariate analysis revealed that a new EUS scope and use of covered metal stents could reduce the fluoroscopy time. The technical success rate and the adverse event rate were not significantly different between the total I-EUS and the EUS-BD only groups. However, the conventional scope showed stent deviation during stent placement, which did not happen with the new scope. Conclusions: The new EUS scope reduced procedure time for total I-EUS and fluoroscopy time for EUS-BD compared to a conventional EUS scope because of the improvement suitable for I-EUS.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38854708

RESUMO

Endoscopic ultrasound (EUS)-guided pancreatic duct drainage includes two procedures: EUS-guided drainage/anastomosis (EUS-D/A) and trans-papillary drainage with EUS-assisted pancreatic rendezvous. EUS-guided pancreatogastrostomy is the most common EUS-D/A procedure and is recommended as a salvage procedure in cases in which endoscopic retrograde cholangiopancreatography fails or is difficult. However, initial EUS-D/A is performed in patients with surgically altered anatomy at our institution. It is one of the most difficult interventional EUS procedures and has a high incidence of adverse events. The technical difficulties differ according to etiology, and the incidence of adverse events varies between initial EUS-D/A and subsequent trans-endosonographically/EUS-guided created route procedures. Hence, it is important to meticulously prepare a procedure based on the patient's condition and the available devices. The technical difficulties in EUS-D/A include: (1) determination of the puncture point, (2) selection of a puncture needle and guidewire, (3) guidewire manipulation, and (4) dilation of the puncture route and stenting. Proper technical procedures are important to increase the success rate and reduce the incidence and severity of adverse events. The complexity of EUS-D/A is also contingent on the severity of pancreatic fibrosis and stricture. In post-pancreatectomy cases, determination of the puncture site is important for success because of the remnant pancreas. Trans-endosonographically/EUS-guided created route procedures following initial EUS-D/A are also important for achieving the treatment goal. This article focuses on effective strategies for initial EUS-D/A, based on the etiology and condition of the pancreas. We mainly discuss EUS-D/A, including its indications, techniques, and success-enhancing strategies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA