Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Heart J Case Rep ; 8(7): ytae344, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39045526

RESUMO

Background: Bioresorbable scaffolds (BRS) have been proposed as an alternative to drug-eluting stents (DES), offering radial support during the early phases of healing, while potentially reducing the risk of long-term complications. A magnesium-based BRS (MgBRS) has shown promising results after implantation. However, there is a lack of knowledge regarding the long-term outcomes. Case summary: A 62-year-old man with hypertension, dyslipidaemia, family history of ischaemic heart disease, and previous myocardial infarction, presented with non-ST-elevation myocardial infarction (NSTEMI). Six years prior, he also had a NSTEMI and a mid-left anterior descending artery (LAD) lesion was treated with a 3.0/25 mm MgBRS. Post-implantation optical coherence tomography (OCT) revealed proximal edge dissection, and a second MgBRS 3.0/15 mm was implanted. Optical coherence tomography of the scaffold-treated segment was performed after 6 and 12 months with no sign of restenosis. The current angiogram showed a restenosis in the previously MgBRS-treated segment in LAD. Optical coherence tomography showed a plaque rupture in a thin cap fibro-atheroma and scaffold remnants. The lesion was pre-dilated and stented with a 3.0/20 mm DES and post-dilated with a 3.5 mm non-compliant balloon. Discussion: Most cases of late scaffold failure showed acquired mal-apposition, which also can be related to the degrading process, or uncovered struts, none of which were seen in our case at 6 or 12 months. This case represents an insight into the vascular healing and potential mechanisms for failure of the MgBRS, with serial OCT recording at implantation, and after 6 months, 12 months, and 6 years.

2.
Contemp Clin Trials Commun ; 38: 101260, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38384894

RESUMO

Introduction: Percutaneous coronary intervention with implantation of a bioresorbable scaffold (BRS) provide the vessel support for a limited period allowing the vessel to restore normal vasomotion after degradation of the BRS, opposed to treatment with drug-eluting stents where the metal persist in the vessel wall. Late lumen loss and reduction in lumen area after implantation have been reported. The purpose of this study was to investigate whether intense pre-dilatation before BRS implantation resulted in less reduction of minimal lumen area at 6- and 12-month follow-up after implantation of a Magmaris BRS (MgBRS). Coronary imaging with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) was assessed to track changes in lumen and vessel dimensions. Methods: The prospective Optimal lesion PreparaTion before Implantation of the Magmaris bioresorbable scaffold In patients with coronary artery Stenosis (OPTIMIS) study randomly assigned eighty-two patients with chronic coronary syndrome to two pre-dilatation treatment strategies. Patients were randomized in a 1:1 ratio to pre-dilatation with either a non-compliant scoring balloon or a standard non-compliant balloon prior to implantation of a MgBRS. The treated segment was evaluated with OCT and IVUS at baseline, after 6 and 12 months to assess changes in lumen and vessel dimensions. The hypothesis was that more intense pre-dilatation with a non-compliant scoring balloon before MgBRS implantation can reduce the risk of late lumen reduction compared to standard pre-dilatation. The power calculation used expected MLA after 6 months (6.22 mm2 for the scoring balloon and 5.01 mm2 for the standard non-compliant balloon), power of 80 %, significance level of 0.05 and expected drop-out rate of 15 %, requiring 82 patients to be enrolled. Results: Eighty-two patients were included in the study. Enrollment was from December 2020 to September 2023. Conclusion: The hypothesis was that more intense pre-dilatation with a non-compliant scoring balloon before MgBRS implantation can reduce the risk of late lumen reduction compared to standard pre-dilatation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA