Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Evol Biol ; 37(8): 960-966, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38766701

RESUMO

Intraspecific variation in vertebrate eye size is well known. Ecological factors such as light availability are often correlated with shifts in relative eye size. However, experimental tests of selection on eye size are lacking. Trinidadian killifish (Anablepsoides hartii) are found in sites that differ in predation intensity. Sites that lack predators are characterized by lower light, high killifish densities, low resource availability, and intense competition for food. We previously found that killifish in sites that lack predators have evolved a larger "relative" eye size (eye size corrected for body size) than fish from sites with predators. Here, we used transplant experiments to test how selection operates on eye size when fish that are adapted to sites with predators are translocated into sites where predators are absent. We observed a significant "population × relative eye size" interaction; the relationship between relative eye size and a proxy for fitness (rates of individual growth) was positive in the transplanted fish. The trend was the opposite for resident fish. Such results provide experimental support that larger eyes enhance fitness and are favoured in environments characterized by low light and high competition.


Assuntos
Olho , Peixes Listrados , Animais , Comportamento Competitivo , Olho/anatomia & histologia , Peixes Listrados/fisiologia , Luz , Tamanho do Órgão , Comportamento Predatório , Seleção Genética
2.
Cureus ; 16(3): e56408, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38638790

RESUMO

Introduction Residual neuromuscular block, defined as a quantitatively measured train-of-four ratio (TOFr) <0.9, is common postoperatively. Using a pragmatic trial design, we hypothesized that qualitative and/or clinical assessment of neuromuscular block would inadequately detect residual block following antagonism with neostigmine or sugammadex. Method After IRB approval and written informed consent, 74 children (aged 2-17 years), undergoing elective surgery and receiving rocuronium, were prospectively enrolled in the study at Children's Hospital Colorado and Children's Healthcare of Atlanta. Routine clinical practice at both institutions consisted of clinical signs and/or qualitative assessment with peripheral nerve stimulators. Children at the Colorado hospital routinely received sugammadex antagonism; whereas children at the Atlanta hospital received neostigmine. Residual neuromuscular block was assessed postoperatively using quantitative electromyography. If TOFr was <0.9, patients received sugammadex until TOFr ≥0.9. Result Qualitative and clinical assessment failed to detect residual block in 29.7% of patients in the neostigmine reversal cohort (adjusted odds ratio (aOR) 29.8, 95% confidence interval (CI): 2.7 to 5,559.5, p-value = 0.002). No residual block was detected in the sugammadex reversal cohort. A correlation between increasing patient weight and incidence of postoperative residual block was observed in the neostigmine cohort (aOR 1.05, 95% CI: 1.02 to 1.10, p-value = 0.002). Conclusion Qualitative and/or clinical assessment of neuromuscular block inadequately detects residual block following neostigmine antagonism.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA