Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Cureus ; 16(5): e60581, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38894773

RESUMO

A 37-year-old woman was admitted to our hospital due to a loss of consciousness. She had been taking 2 mg of tizanidine for two months to manage shoulder muscle pain at night. On admission, an electrocardiogram showed sinus bradycardia with a heart rate of 30 bpm and QT prolongation (QTc 495 msec). She had a temporary pacemaker inserted in the catheterization room, after which an improvement in her level of consciousness was observed. There were no apparent endocrine disorders or structural heart diseases. The administration was discontinued after admission, and 12 hours after admission, her heart rate normalized to a sinus rhythm of 70-100 bpm, and QTc improved to 431 msec. Therefore, she was diagnosed with tizanidine-induced bradycardia. Although reports of tizanidine-induced bradycardia are rare, tizanidine's central α2 agonistic effects can cause bradycardia, necessitating caution.

2.
J Cardiol Cases ; 29(2): 89-92, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38362579

RESUMO

Insertable cardiac monitors (ICMs) are small electrocardiographs implanted subcutaneously to automatically record electrocardiograms when arrhythmia is detected in patients with syncope. If the ICM misses a significant arrhythmia, it may delay the diagnosis of arrhythmogenic syncope and put the patient at risk. Herein, we describe a case of undetected cardiac arrest in a patient with ICM. An 87-year-old man with syncope was admitted to the hospital. After 8 days of monitoring, the cause could not be determined, and an ICM was implanted. Nine hours after implantation, the patient experienced cardiopulmonary arrest. Despite a body surface electrocardiogram showing ventricular flatline and fibrillation, the ICM failed to record. The cause of failure to record was considered to be the fluctuation in the R-wave amplitude of the ICM and noise oversensing. In conclusion, albeit infrequently, ICMs might overlook life-threatening arrhythmias. Even in cases where the ICM fails to detect an arrhythmia matching the symptoms, it may not be feasible to entirely rule out the presence of arrhythmias. Learning objective: Insertable cardiac monitors (ICMs) are used to diagnose arrhythmogenic syncope. However, extremely infrequently, ICM may fail to record life-threatening arrhythmias. Failure to capture arrhythmias can happen due to an unfortunate combination of factors such as a low amplitude of the recorded R wave and noise. Even in cases where the ICM does not detect an arrhythmia that matches the symptoms, it may not be feasible to completely exclude the presence of arrhythmias.

3.
Acta Biomater ; 183: 111-129, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38801868

RESUMO

The development of high-throughput anticancer drug screening methods using patient-derived cancer cell (PDC) lines that maintain their original characteristics in an in vitro three-dimensional (3D) culture system poses a significant challenge to achieving personalized cancer medicine. Because stromal tissue plays a critical role in the composition and maintenance of the cancer microenvironment, in vitro 3D-culture using reconstructed stromal tissues has attracted considerable attention. Here, a simple and unique in vitro 3D-culture method using heparin and collagen together with fibroblasts and endothelial cells to fabricate vascularized 3D-stromal tissues for in vitro culture of PDCs is reported. Whereas co-treatment with bevacizumab, a monoclonal antibody against vascular endothelial growth factor, and 5-fluorouracil significantly reduced the survival rate of 3D-cultured PDCs to 30%, separate addition of each drug did not induce comparable strong cytotoxicity, suggesting the possibility of evaluating the combined effect of anticancer drugs and angiogenesis inhibitors. Surprisingly, drug evaluation using eight PDC lines with the 3D-culture method resulted in a drug efficacy concordance rate of 75% with clinical outcomes. The model is expected to be applicable to in vitro throughput drug screening for the development of personalized cancer medicine. STATEMENT OF SIGNIFICANCE: To replicate the cancer microenvironment, we constructed a cancer-stromal tissue model in which cancer cells are placed above and inside stromal tissue with vascular network structures derived from vascular endothelial cells in fibroblast tissue using CAViTs method. Using this method, we were able to reproduce the invasion and metastasis processes of cancer cells observed in vivo. Using patient-derived cancer cells, we assessed the possibility of evaluating the combined effect with an angiogenesis inhibitor. Further, primary cancer cells also grew on the stromal tissues with the normal medium. These data suggest that the model may be useful for new in vitro drug screening and personalized cancer medicine.


Assuntos
Antineoplásicos , Ensaios de Seleção de Medicamentos Antitumorais , Humanos , Antineoplásicos/farmacologia , Ensaios de Seleção de Medicamentos Antitumorais/métodos , Linhagem Celular Tumoral , Células Estromais/efeitos dos fármacos , Células Estromais/citologia , Células Estromais/metabolismo , Técnicas de Cultura de Células em Três Dimensões/métodos , Ensaios de Triagem em Larga Escala/métodos , Microambiente Tumoral/efeitos dos fármacos , Células Endoteliais da Veia Umbilical Humana/metabolismo , Células Endoteliais da Veia Umbilical Humana/efeitos dos fármacos , Feminino , Fibroblastos/efeitos dos fármacos , Fibroblastos/metabolismo , Fibroblastos/citologia , Técnicas de Cocultura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA