Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Int J Mol Sci ; 25(11)2024 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-38891965

RESUMO

Cardioembolic stroke accounts for over 20% of ischemic strokes and is associated with worse outcomes than other types of strokes. Atrial fibrillation (AF) is the most common risk factor for cardioembolic stroke. In this narrative review, we present an update about cardioembolic stroke mainly related to AF and atrial cardiopathy. Direct oral anticoagulants (DOACs) have revolutionized stroke prevention in patients with AF; however, their efficacy in preventing recurrent embolic stroke of unknown source remains uncertain. Various cardiac monitoring methods are used to detect AF, which is crucial for preventing stroke recurrence. DOACs are preferred over warfarin for AF-related stroke prevention; however, the timing of initiation after acute ischemic stroke is debated. Resuming anticoagulation after intracerebral hemorrhage in AF patients requires careful assessment of the risks. While catheter ablation may reduce the incidence of cardiovascular events, its effect on stroke prevention is unclear, especially in heart failure patients. Atrial cardiopathy is the emerging cause of embolic stroke of unknown source, which indicates atrial structural and functional disorders that can precede AF. Future research should focus on refining stroke risk prediction models, optimizing AF detection, understanding the roles of ablation and anticoagulation in stroke prevention, and establishing atrial cardiopathy as a therapeutic target, which could significantly reduce the burden of stroke.


Assuntos
Anticoagulantes , Fibrilação Atrial , AVC Embólico , Humanos , AVC Embólico/etiologia , Fibrilação Atrial/complicações , Anticoagulantes/uso terapêutico , Fatores de Risco
2.
J Cardiovasc Electrophysiol ; 34(1): 71-81, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378816

RESUMO

INTRODUCTION: Local impedance (LI) parameters of IntellaNav STABLEPOINT for successful pulmonary vein isolation (PVI) of atrial fibrillation (AF) remain unclear. The purpose of this study was to seek LI data achieving successful PVI. METHODS: Consecutive AF patients who underwent catheter ablation with STABLEPOINT were prospectively enrolled in two centers. PVI was performed under a constant 35-or 40-watt power, 20-s duration, and >5-g contact force. The operators were blinded to the LI data. The characteristics of all ablation points with/without conduction gaps (Unsuccess or Success tags) after the first-attempt PVI were evaluated for the right/left PVs and anterior/posterior wall (RPV/LPV and AW/PW, respectively), and cutoff values of LI data were calculated for successful lesion formation. RESULTS: A total of 5257 ablation points in 102 patients (65 [58-72] years old, 65.7% male) were evaluated. The LI drop values were higher in the Success tags than Unsuccess tags on the LPV-AW and RPV-AW/PW (p < .001), except for the LPV-PW (p = .105). The %LI drop values (LI drop/initial LI) were higher for the Success tags in all areas (15.8 [12.2%-19.6%] vs. 11.6 [9.7%-15.6%] in LPV-AW: p < .001, 15.0 [11.5%-19.3%] vs. 11.4 [8.7%-17.3%] in LPV-PW: p = .035, 15.3 [11.5%-19.4%] vs. 9.9 [8.1%-13.7%] in RPV-AW: p < .001, and 13.3 [10.1%-17.4%] vs. 8.1 [6.3%-9.5%] in RPV-PW, p < .001). The LI drop and %LI drop cutoff values were 20.0 ohms and 11.6%, respectively. CONCLUSIONS: An insufficient LI drop with STABLEPOINT was associated with a gap formation during PVI, and the best cutoff values for the LI drop and %LI drop were 20.0 ohms and 11.6%, respectively.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Impedância Elétrica , Resultado do Tratamento , Frequência Cardíaca , Ablação por Cateter/efeitos adversos , Recidiva
3.
Artigo em Inglês | MEDLINE | ID: mdl-37561371

RESUMO

The subclavian vein is typically used in cardiovascular implantable electronic device (CIED) implantations. External stress on the subclavian vein can lead to lead-related complications. There are several causes of this stress, such as frequent upper extremity movements or external injury. Venous thoracic outlet syndrome (TOS) can also become the cause of external lead stress. However, the diagnosis of venous TOS can be challenging because subclavian venography can appear normal at first glance. We present a unique case of a device infection in a patient with venous TOS. A careful observation of the imaging studies is vital for diagnosing venous TOS and a leadless pacemaker implantation could be an alternative therapeutic option.

4.
Heart Vessels ; 38(2): 216-227, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36173447

RESUMO

Sub-optimal atrioventricular delay (AVD) is one of the main causes of non-responder for cardiac resynchronization therapy (CRT). Recently, device-based algorithms (DBAs) that provide optimal AVD based on intracardiac electrograms, have been developed. However, their long-term effectiveness is still unknown. This study aims to investigate the effect of optimizing AVD using DBAs over a long period, on the prognosis of patients undergoing CRT. A total of 118 patients who underwent CRT at our hospital between April 2008 and March 2018, were retrospectively reviewed; 61 of them with optimizing AVD using DBAs were classified into the treated group (group 1), and the remaining 57 were classified into the control group (group 2). The median follow-up period was 46.0 months. The responder and survival rate in group 1 were significantly better than those in group 2 (group 1 vs. group 2: responder rate = 64% vs. 46%, p = 0.046; survival rate: 85.2% vs. 64.9%, p = 0.02). Moreover, investigating only the non-responder population showed that group 1 had an improved survival rate compared to group 2 (group 1 vs. group 2 = 72.7% vs. 45.1%, p = 0.02). Optimizing AVD using DBAs was a significant contributor to the improved survival rate in CRT non-responders in multivariate analysis (HR 3.6, p = 0.01). In conclusion, the long-term optimizing AVD using DBAs improved the survival rate in CRT and the prognosis of CRT non-responders, as well.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Estudos Retrospectivos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Prognóstico , Algoritmos , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 33(6): 1336-1340, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35347781

RESUMO

INTRODUCTION: Whether diagnostic computed tomography (CT) scans to cardiac implantable electronic devices (CIED) is safe in recent models remains unknown. METHODS: A two-centers observational study. Over 14 years, consecutive 2362 chest CT scans (1666 pacemakers [PMs], 145 cardiac resynchronization therapy PM, 316 implantable cardioverter-defibrillator, and 233 cardiac resynchronization therapy defibrillator) were interrogated and monitored upon imaging. RESULTS: Electromagnetic interference occurred only in a few old models: InSync 8040 (n = 14), InSync III Marquis (n = 1), and Kappa (n = 4), which resulted no adverse events. CONCLUSION: CIEDs, especially recent ones, are confirmed safe on chest CT.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Marca-Passo Artificial , Computadores , Desfibriladores Implantáveis/efeitos adversos , Humanos , Marca-Passo Artificial/efeitos adversos , Tomografia
6.
Pacing Clin Electrophysiol ; 45(12): 1390-1400, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36222300

RESUMO

BACKGROUND: A novel irrigation catheter (QDOT MICRO™) has been introduced, which enables a surface temperature-controlled ablation combined with tip cooling. However, the detailed description of its complex behavior and effect on the incidence of pops and lesion formation remains elusive. This study aimed to systematically investigate the ablation characteristics, feedback behavior, and incidence of steam pops in a simplified ex vivo swine model. METHODS: Using swine ventricular tissue perfused with saline at 37°C, we systematically created lesions with 4×3 combinations of the wattage (20, 30, 40, and 50 W) and contact force (CF, 10, 30, and 50 g). Ablation was continued for either 120 s or until a steam pop occurred and repeated 10 times with each setting. The lesion geometry, ablation index, feedback dynamics, and conditions underlying the steam pops were measured and analyzed. RESULTS: Steam pops occurred particularly frequently in combinations of a low CF and high power (10 g vs. 30 g+50 g [p < .0001]; 40 W+50 W vs. 20 W+30 W [p < .0001]). Failure to activate a feedback process was associated with a 5.1 times higher incidence of steam pops (21/109 vs.11/11, [95% CI 3.499-7.716], p < .0001). The wattage feedback was particularly evident with a high CF (30 and 50 g) and high initial wattage (40 and 50 W). The average delivered wattage at 27 W predicted the occurrence of steam pops. CONCLUSION: The temperature-controlled ablation with the QDOT MICRO™ demonstrated a complex feedback behavior, which contributed to a reduced incidence of steam pops and prolonged lead time to the pops.


Assuntos
Modelos Teóricos , Vapor , Animais , Suínos
7.
Int Heart J ; 63(5): 953-956, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36184554

RESUMO

The Senning operation used to be widely performed for an intracardiac repair in a complete transposition of the great arteries. During the long-term follow-up, supraventricular tachycardia (SVT) is often observed because of the complex suture lines. The typical mechanism of a Senning-related SVT is cavo-tricuspid isthmus-dependent atrial flutter. On rare occasions, complex SVTs (e.g., biatrial tachycardia (BiAT)) whose diagnosis and treatment are challenging, may occur. We report a rare case of a BiAT following a Senning operation that was successfully ablated from the superior vena cava, and the local activation time histogram module (CARTO3 V7 module [Biosense Webster, Irvine, CA, USA]) was crucial for analyzing the complex circuit.


Assuntos
Transposição das Grandes Artérias , Ablação por Cateter , Situs Inversus , Taquicardia Supraventricular , Transposição dos Grandes Vasos , Transposição das Grandes Artérias/efeitos adversos , Artérias , Ablação por Cateter/efeitos adversos , Humanos , Situs Inversus/complicações , Taquicardia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/cirurgia , Transposição dos Grandes Vasos/complicações , Transposição dos Grandes Vasos/cirurgia , Veia Cava Superior/cirurgia
8.
J Cardiovasc Electrophysiol ; 32(12): 3187-3194, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34559441

RESUMO

BACKGROUND: Local impedance (LI) has emerged as a new technology that informs on electrical catheter-tissue coupling during radiofrequency (RF) ablation. Recently, IntellaNav StablePoint, a novel LI-enabled catheter that equips contact force (CF) sensing, has been introduced. Although StablePoint and its predecessor IntellaNav MiFi OI share the common technology that reports LI, distinct mechanics for LI sensing between the two products raise a concern that the LI-RF lesion formation relationship may differ. METHODS: In an ex vivo swine cardiac tissue model, we investigated the initial level and range of a reduction in LI during a 60-s RF ablation and the resultant lesion characteristics at nine combinations of three energy power (30, 40, and 50 W) and CF (10, 30, and 50 g) steps. Correlations and interactions between CF, LI, wattage, and formed lesions were analyzed. Incidence of achieving LI drop plateau and that of a steam pop were also determined. RESULTS: Positive correlations existed between CF and initial LI, CF and absolute/relative LI drop, CF and lesion volume, and LI drop and lesion volume. At the same LI drop, wattage-dependent gain in lesion volume was observed. Steam pops occurred in all CF steps and the prevalence was highest at 50 W. LI drop predicted a steam pop with a cutoff value at 89Ω. CONCLUSION: In StablePoint, wattage crucially affects LI drop and lesion volume. Because 30 W ablation may by underpowered for intramural lesion formation and 50 W often resulted in a steam pop, 40 W appears to achieve the balance between the safety and efficacy.


Assuntos
Ablação por Cateter , Animais , Ablação por Cateter/métodos , Catéteres , Impedância Elétrica , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Ventrículos do Coração/cirurgia , Vapor , Suínos
9.
J Cardiovasc Electrophysiol ; 32(8): 2069-2076, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34185348

RESUMO

BACKGROUND: The local impedance (LI) reflects the electrical catheter-tissue coupling and correlates with the local tissue temperature. However, there have been few clinical studies showing the recommended method for LI monitoring catheters. This study aimed to investigate the optimal ablation setting for this catheter in an in vitro experimental model. METHODS: LI monitoring catheters were used in an excised swine heart experimental model. The tissue contact force (CF) was directly monitored from an external weight scale. Radiofrequency ablation was performed with a combination of various energy power settings (30, 40, and 50 W), and various CFs (10, 30, and 50 g) for 60 s. The correlation between the LI-related indexes, power, and CF with the lesion formation was statistically analyzed. RESULTS: A positive correlation between the LI or lesion formation and CF was observed under all powers. Although the LI drop always correlated with the maximum lesion depth, lesion diameter, and lesion volume, the coefficient of the correlation value was lower under a high CF (lesion depth, diameter, and volume; 10 g, r = 0.8064, r = 0.8389, r = 0.8477; 30 g, r = 0.7590, r = 0.8063, r = 0.8060; 50 g r = 0.5555, r = 0.5701, and r = 0.5678, respectively). Steam pops occurred only under a 50 W ablation and the LI drop cutoff value for steam pops was 46 Ω. CONCLUSION: The same LI drop did not always lead to the same lesion size when the CF differed. Monitoring the LI and not exceeding 46 Ω would be useful for a safe ablation.


Assuntos
Ablação por Cateter , Animais , Catéteres , Impedância Elétrica , Modelos Teóricos , Vapor , Suínos
10.
J Cardiovasc Electrophysiol ; 32(7): 1877-1883, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33955099

RESUMO

INTRODUCTION: Detailed three-dimensional (3D) mapping has been useful for effective radiofrequency catheter ablation. The Rhythmia system can create atrio-ventricular dual-chamber mapping, which reveals the atrial and ventricular potentials all at once in the same map. The aim of this study was to investigate the utility of mapping the atrium and ventricle simultaneously with a high-density 3D mapping system for the ablation of accessory pathways (AP). METHODS: From July 2015 to August 2020, 111 patients underwent ablation of APs. Dual-chamber maps were created in 50 patients (median age 15 [10-54], 32 male [64.0%]), while 61 patients underwent radiofrequency (RF) ablation with conventional single-chamber 3D maps. The background characteristics and procedural details were compared between the dual-chamber mapping group and the conventional single-chamber mapping group. RESULTS: The number of RF applications (median [IQR]; 1.0 [1.0-3.0] vs. 3.0 [1.0-6.0], p = .0023), RF time (median [IQR], s; 9.2 [2.0-95.7] vs. 95.6 [4.1-248.7], p = .0107), and RF energy (median [IQR], J; 248.4 [58.7-3328.2] vs. 2867.6 [134.2-7728.4], p = .0115) were significantly lower in the dual-chamber group. The fluoroscopy time (median [IQR], min; 19.9 [14.2-26.1] vs. 26.5 [17.7-43.4], p = .0025) and fluoroscopy dose (median [IQR], mGy; 52.5 [31.3-146.0] vs. 119.0 [43.7-213.5], p = .0249) were also significantly lower in the dual-chamber than single-chamber mapping group. CONCLUSION: The dual-chamber mapping was useful for ablating accessory pathways and reducing the number of RF applications, total RF energy, and radiation exposure as compared with traditional mapping techniques.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Exposição à Radiação , Feixe Acessório Atrioventricular/diagnóstico por imagem , Feixe Acessório Atrioventricular/cirurgia , Adolescente , Fluoroscopia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino
11.
Pacing Clin Electrophysiol ; 44(3): 481-489, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33393087

RESUMO

BACKGROUND: After the reports of recalled leads, several technological improvements have been introduced and the durability of implantable cardioverter defibrillator (ICD) leads has improved. The incidence of lead failures is now less than in the previous studies. However, there are few reports that have shown the long-term durability of ICD leads as compared to pacemaker (PM) leads. This study analyzed the medium to long-term performance of transvenous ICD leads as compared to PM leads. METHODS: We retrospectively studied 1227 cases from April 2007 to December 2017 who underwent an initial transvenous ICD or PM implantation. The number of lead failures and patient background characteristics were analyzed. RESULTS: During a median 3-3.5 years follow up period, 1 (0.3%) ICD lead and 18 (2.4%) PM leads failed. The incidence of lead failures was significantly higher in the PM group than ICD group (p = .019). Males were associated with a higher incidence of lead failures in the PM group. CONCLUSION: Since the era of recalled ICD leads, the durability of ICD leads has remarkably improved and the incidence of lead failures with non-recalled ICD leads has been less than that for PM leads.


Assuntos
Desfibriladores Implantáveis , Eletrodos Implantados , Marca-Passo Artificial , Idoso , Remoção de Dispositivo , Análise de Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores Sexuais
12.
Int Heart J ; 61(5): 913-921, 2020 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-32921668

RESUMO

Previous study has identified marked differences in patient characteristics and causes of inappropriate shock (IAS) between Japan and the Western societies in terms of subcutaneous implantable cardioverter-defibrillator (S-ICD). However, evidence of IAS in Asian populations including Japan has been limited to one observational study.Thus, we conducted a single-center registry study that tracks the postoperative course of 61 consecutive patients who received S-ICD from February 2016 to January 2020. Our findings showed that IAS occurred in 9.8% of the study population (6/61), which is comparable to the previously reported incidence. Remarkably, T-wave oversensing did not result in an IAS (0/6). Instead, myopotential oversensing was determined to have caused the most IAS events (4/6), while atrial fibrillation ranked second (2/6). A provocation maneuver (e.g., abdominal clench, push-ups, lifting a heavy item) reproduced myopotential noise disguised as R-waves, which should potentially trigger an IAS if uninterrupted. R-wave amplitude of the IAS group appeared relatively low compared to that of the non-IAS group although this finding was not tested significant. Furthermore, no temporal changes were noted in R-wave amplitude between the time of implantation and IAS events, suggesting that it is neither constantly low nor acutely dropped R-wave amplitude but a relatively high noise level that drives IAS. All the myopotential-IAS patients were found to be male. Right-sided lead implantation was associated with a higher incidence of IAS.This study highlights the fact that IAS continues to occur due to myopotential noise oversensing instead of T-wave oversensing. To minimize the risk of IAS, it is desirable to search and secure high R-wave voltage.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/estatística & dados numéricos , Músculo Esquelético/fisiologia , Taquicardia Ventricular/diagnóstico , Fibrilação Ventricular/diagnóstico , Adolescente , Adulto , Idoso , Criança , Erros de Diagnóstico , Falha de Equipamento , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Adulto Jovem
13.
Int Heart J ; 61(1): 54-59, 2020 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-31956147

RESUMO

Right ventricular (RV) lead perforations are relatively rare but a potentially life-threatening complication of surgical implantations of cardiac implantable electronic devices (CIEDs). The result of percutaneous simple lead traction after lead perforations in the Japanese population has not been well clarified.We retrospectively studied 1359 patients (pacemakers [PMs], 973 patients; implantable cardioverter defibrillators [ICD], 386 patients) from April 2007 to December 2018 who underwent initial CIED implantation. Fifteen patients (1.1%) were diagnosed with RV lead perforations. The clinical data were evaluated in those patients, and the baseline characteristics and echocardiographic data were compared between the lead perforation group and the non-perforation group. The success and complication rates of the simple traction and repositioning of the RV lead were also assessed.The number of perforated RV leads was seven ICD leads (1.8%) and eight PM leads (0.82%). They were diagnosed on a median seven days (5.5-36.0) after the CIED implantation. Twelve patients were asymptomatic but were detected by an increased capture threshold. Three patients had pericarditis and stimulation of the diaphragm. Only one patient in the ICD lead group who took anticoagulants had a cardiac tamponade and needed an urgent pericardiocentesis (0.07%). No one required a thoracotomy or other devices related to complications after repositioning the RV lead. There was no significant difference in the baseline characteristics and echocardiographic parameters between the groups.RV lead perforations were relatively rare complications of CIED implantations. Percutaneous simple lead traction and repositioning the perforated lead was feasible and effective if the patients did not receive anticoagulants.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Traumatismos Cardíacos/terapia , Chumbo/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Traumatismos Cardíacos/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Estudos Retrospectivos
14.
Am J Physiol Heart Circ Physiol ; 314(3): H403-H414, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28916636

RESUMO

Cardiac pacemaker cells, including cells of the sinoatrial node, are heterogeneous in size, morphology, and electrophysiological characteristics. The exact extent to which these cells differ electrophysiologically is unclear yet is critical to understanding their functioning. We examined major ionic currents in individual intercaval pacemaker cells (IPCs) sampled from the paracristal, intercaval region (including the sinoatrial node) that were spontaneously beating after enzymatic isolation from rabbit hearts. The beating rate was measured at baseline and after inhibition of the Ca2+ pump with cyclopiazonic acid. Thereafter, in each cell, we consecutively measured the density of funny current ( If), delayed rectifier K+ current ( IK) (a surrogate of repolarization capacity), and L-type Ca2+ current ( ICa,L) using whole cell patch clamp. The ionic current densities varied to a greater extent than previously appreciated, with some IPCs demonstrating very small or zero If . The density of none of the currents was correlated with cell size, while ICa,L and If densities were related to baseline beating rates. If density was correlated with IK density but not with that of ICa,L. Inhibition of Ca2+ cycling had a greater beating rate slowing effect in IPCs with lower If densities. Our numerical model simulation indicated that 1) IPCs with small (or zero) If or small ICa,L can operate via a major contribution of Ca2+ clock, 2) If-Ca2+-clock interplay could be important for robust pacemaking function, and 3) coupled If- IK function could regulate maximum diastolic potential. Thus, we have demonstrated marked electrophysiological heterogeneity of IPCs. This heterogeneity is manifested in basal beating rate and response to interference of Ca2+ cycling, which is linked to If. NEW & NOTEWORTHY In the present study, a hitherto unrecognized range of heterogeneity of ion currents in pacemaker cells from the intercaval region is demonstrated. Relationships between basal beating rate and L-type Ca2+ current and funny current ( If) density are uncovered, along with a positive relationship between If and delayed rectifier K+ current. Links are shown between the response to Ca2+ cycling blockade and If density.


Assuntos
Relógios Biológicos , Canais de Cálcio Tipo L/metabolismo , Sinalização do Cálcio , Canais de Potássio de Retificação Tardia/metabolismo , Frequência Cardíaca , Potássio/metabolismo , Nó Sinoatrial/metabolismo , Potenciais de Ação , Animais , Masculino , Potenciais da Membrana , Fenótipo , Coelhos , Nó Sinoatrial/citologia , Fatores de Tempo
15.
Int Heart J ; 56(5): 555-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26346519

RESUMO

Electrical storm (ES) was observed in an 82-year-old man with recent myocardial infarction. Conventional therapy, including amiodarone, could not suppress the ES. After more than 100 electrical defibrillations, we were finally able to control the ES with the administration of landiolol. It is known that landiolol can inhibit ES. However, we hesitate to use landiolol in patients with low cardiac output. We would like to emphasize that careful use of landiolol should be considered in patients with refractory ES after myocardial infarction, although cardiac output is severely reduced.


Assuntos
Cardioversão Elétrica/métodos , Morfolinas/administração & dosagem , Infarto do Miocárdio , Ureia/análogos & derivados , Antagonistas Adrenérgicos beta/administração & dosagem , Idoso de 80 Anos ou mais , Angiografia Coronária/métodos , Eletrocardiografia , Humanos , Masculino , Infarto do Miocárdio/complicações , Infarto do Miocárdio/fisiopatologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento , Ureia/administração & dosagem
16.
Artigo em Inglês | MEDLINE | ID: mdl-38787663

RESUMO

INTRODUCTION: Deep learning models for detecting episodes of atrial fibrillation (AF) using rhythm information in long-term ambulatory ECG recordings have shown high performance. However, the rhythm-based approach does not take advantage of the morphological information conveyed by the different ECG waveforms, particularly the f-waves. As a result, the performance of such models may be inherently limited. METHODS: To address this limitation, we have developed a deep learning model, named RawECGNet, to detect episodes of AF and atrial flutter (AFl) using the raw, single-lead ECG. We compare the generalization performance of RawECGNet on two external data sets that account for distribution shifts in geography, ethnicity, and lead position. RawECGNet is further benchmarked against a state-of-the-art deep learning model, named ArNet2, which utilizes rhythm information as input. RESULTS: Using RawECGNet, the results for the different leads in the external test sets in terms of the F1 score were 0.91-0.94 in RBDB and 0.93 in SHDB, compared to 0.89-0.91 in RBDB and 0.91 in SHDB for ArNet2. The results highlight RawECGNet as a high-performance, generalizable algorithm for detection of AF and AFl episodes, exploiting information on both rhythm and morphology.

17.
J Interv Card Electrophysiol ; 67(3): 589-597, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37691083

RESUMO

BACKGROUND: Lesion formation during catheter ablation is influenced by the power, contact force (CF), time, and catheter stability. However, the influence of the irrigation effects on lesion formation remains unknown. METHODS: An ex vivo experiment using conductive gel was performed. Using three different catheter designs (TactiFlex ™ SE [TF], IntellaNav MiFi ™ OI [MiFi], QDOT MICRO™ [QDOT]), a cross-sectional analysis of the lesion size and surface lesion type of 10g/40W lesions with a combination of various ablation times was performed in protocol 1. A longitudinal analysis (combination of various powers [30, 40, and 50W] and various ablation times with a 10g setting) was performed to investigate the influence of the auto-regulated irrigation system (QDOT) on lesion formation in protocol 2. RESULTS: The lesion formation with the QDOT catheter tended to create larger ablation lesions, while that with the TF catheter created smaller lesions than the other catheters. The lesion surface characteristics were divided into two patterns: ring (MiFi catheter and QDOT) and crescent (TF) patterns. The auto-regulated irrigation system did not influence the lesion formation, and the relationship between the lesion formation and RF energy exhibited similar changes regardless of the ablation power setting. CONCLUSION: The lesion formation and lesion surface characteristics differed among the different irrigation tip designs. An auto-regulated irrigation system did not affect the lesion creation or surface lesion characteristics. Care should be given to the inter-product differences in the lesion characteristics during RF catheter ablation, partly due to the irrigation flow control and tip design.


Assuntos
Ablação por Cateter , Irrigação Terapêutica , Humanos , Estudos Transversais , Irrigação Terapêutica/métodos , Catéteres , Ablação por Cateter/métodos , Impedância Elétrica , Desenho de Equipamento
18.
J Interv Card Electrophysiol ; 67(1): 147-155, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37311981

RESUMO

BACKGROUND: The lesion index (LSI) helps predict the lesion size and is widely used in ablation of various types of arrhythmias. However, the influence of the ablation settings on the lesion formation and incidence of steam pops under the same LSI value remains unclear. METHODS: Using a contact force (CF) sensing catheter (TactiCath™) in an ex vivo swine left ventricle model, RF lesions were created with a combination of various power steps (30 W, 40 W, 50 W) and CFs (10 g, 20 g, 30 g, 40 g, 50 g) under the same LSI values (5.2 and 7.0). The correlation between the lesion formation and ablation parameters was evaluated. RESULTS: Ninety RF lesions were created under a target LSI value of 5.2, and eighty-four were developed under a target LSI value of 7.0. In the LSI 5.2 group, the resultant lesion size widely varied according to the ablation power, and a multiple regression analysis indicated that the ablation energy delivered was the best predictor of the lesion formation. To create a lesion depth > 4 mm, an ablation energy of 393 J is the best cutoff value, suggesting a possibility that ablation energy may be used as a supplemental marker that better monitors the progress of the lesion formation in an LSI 5.2 ablation. In contrast, such inconsistency was not obvious in the LSI 7.0 group. Compared with 30 W, the 50-W ablation exhibited a higher incidence of steam pops in both the LSI 5.2 and 7.0 groups. CONCLUSIONS: The LSI-lesion size relationship was not necessarily consistent, especially for an LSI of 5.2. To avoid any unintentional, weak ablation, the ablation energy may be a useful supportive parameter (393 J as a cutoff value for a 4-mm depth) during ablation with an LSI around 5.2. Thanks to a prolonged ablation time, the LSI-lesion size relationship is consistent for an LSI of 7.0. However, it is accompanied by a high incidence of steam pops. Care should be given to the ablation settings even when the same LSI value is used.


Assuntos
Ablação por Cateter , Suínos , Animais , Vapor , Ventrículos do Coração/cirurgia , Arritmias Cardíacas/cirurgia
19.
J Arrhythm ; 40(2): 349-355, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38586843

RESUMO

Objective: Postoperative pain is a major issue with subcutaneous implantable cardioverter defibrillators (S-ICD). In 2020, we introduced intravenous patient-controlled analgesia (IV-PCA) in addition to the conventional, request-based analgesia for postoperative pain control in S-ICD. To determine the effect and safety, we quantitatively assessed the effect of IV-PCA after S-ICD surgery over conventional methods. Methods: During the study period, a total of 113 consecutive patients (age, 50.1 ± 15.5 years: males, 101) underwent a de novo S-ICD implantation under general anesthesia. While the postoperative pain was addressed with either request-based analgesia (by nonsteroid anti-inflammatory drugs, N = 68, dubbed as "PCA absent") or fentanyl-based IV-PCA in addition to the standard care (N = 45, dubbed as "PCA present"). The degree of postoperative pain from immediately after surgery to 1 week were retrospectively investigated by the numerical rating scale (NRS) divided into four groups at rest and during activity (0: no pain, 1-3: mild pain, 4-6: moderate pain, 7-10: severe pain). Results: Although IV-PCA was removed on Day 1, it was associated with continued better pain control compared to PCA absent group. At rest, the proportion of patients expressing pain (mild or more) was significantly lower in the PCA present group from Day 0 to Day 4. In contrast to at rest, a better pain control continued through the entire study period of 7 days. No serious adverse events were observed. A few patients experienced nausea in both groups and the inter-group difference was not found significant. Conclusion: IV-PCA suppresses postoperative pain in S-ICD without major safety concerns.

20.
Geriatrics (Basel) ; 9(1)2024 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-38392108

RESUMO

BACKGROUND: The second demonstration experiment of supporting elderly people going out with the Choisoko system was conducted. The first study showed that for women, friends, shopping, convenience, and events are factors that have the potential to be effective motivational factors for encouraging these women to go out. On the other hand, these factors did not lead to any behavioral change in men. Since there are approximately 15 million men over the age of 65 in Japan, behavioral changes in the entire elderly population will not occur without guidance for elderly men to go out. METHODS: Sixteen elderly men and forty-seven elderly women participated. Interestingly, men are far more passionate about games than women. Therefore, we hypothesized that a preference for games could be a hint as to how we might encourage older men to go out. Then, a second demonstration experiment was conducted, and we analyzed the relationship between six game preferences and the frequency of going out. RESULTS: Among gaming preferences, men with gaming preferences such as Philanthropists, Achievers, and Free Spirits showed a tendency to go out. CONCLUSIONS: These stimuli may have the potential to be factors that may encourage elderly men to go out.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA