Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Magn Reson Med ; 91(4): 1598-1607, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38156827

RESUMO

PURPOSE: To show that B 0 $$ {\mathrm{B}}_0 $$ variations through slice and slice profile effects are two major confounders affecting 2D dual angle B 1 + $$ {\mathrm{B}}_1^{+} $$ maps using gradient-echo signals and thus need to be corrected to obtain accurate B 1 + $$ {\mathrm{B}}_1^{+} $$ maps. METHODS: The 2D gradient-echo transverse complex signal was Bloch-simulated and integrated across the slice dimension including nonlinear variations in B 0 $$ {\mathrm{B}}_0 $$ inhomogeneities through slice. A nonlinear least squares fit was used to find the B 1 + $$ {\mathrm{B}}_1^{+} $$ factor corresponding to the best match between the two gradient-echo signals experimental ratio and the Bloch-simulated ratio. The correction was validated in phantom and in vivo at 3T. RESULTS: For our RF excitation pulse, the error in the B 1 + $$ {\mathrm{B}}_1^{+} $$ factor scales by approximately 3.8% for every 10 Hz/cm variation in B 0 $$ {\mathrm{B}}_0 $$ along the slice direction. Higher accuracy phantom B 1 + $$ {\mathrm{B}}_1^{+} $$ maps were obtained after applying the proposed correction; the root mean square B 1 + $$ {\mathrm{B}}_1^{+} $$ error relative to the gold standard B 1 + $$ {\mathrm{B}}_1^{+} $$ decreased from 6.4% to 2.6%. In vivo whole-liver T 1 $$ {\mathrm{T}}_1 $$ maps using the corrected B 1 + $$ {\mathrm{B}}_1^{+} $$ map registered a significant decrease in T 1 $$ {\mathrm{T}}_1 $$ gradient through slice. CONCLUSION: B 0 $$ {\mathrm{B}}_0 $$ inhomogeneities varying through slice were seen to have an impact on the accuracy of 2D double angle B 1 + $$ {\mathrm{B}}_1^{+} $$ maps using gradient-echo sequences. Consideration of this confounder is crucial for research relying on accurate knowledge of the true excitation flip angles, as is the case of T 1 $$ {\mathrm{T}}_1 $$ mapping using a spoiled gradient recalled echo sequence.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Análise dos Mínimos Quadrados , Frequência Cardíaca
2.
Int J Cardiol ; : 132415, 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39127146

RESUMO

BACKGROUND: The role of ECG in ruling out myocardial complications on cardiac magnetic resonance (CMR) is unclear. We examined the clinical utility of ECG in screening for cardiac abnormalities on CMR among post-hospitalised COVID-19 patients. METHODS: Post-hospitalised patients (n = 212) and age, sex and comorbidity-matched controls (n = 38) underwent CMR and 12­lead ECG in a prospective multicenter follow-up study. Participants were screened for routinely reported ECG abnormalities, including arrhythmia, conduction and R wave abnormalities and ST-T changes (excluding repolarisation intervals). Quantitative repolarisation analyses included corrected QT (QTc), corrected QT dispersion (QTc disp), corrected JT (JTc) and corrected T peak-end (cTPe) intervals. RESULTS: At a median of 5.6 months, patients had a higher burden of ECG abnormalities (72.2% vs controls 42.1%, p = 0.001) and lower LVEF but a comparable cumulative burden of CMR abnormalities than controls. Patients with CMR abnormalities had more ECG abnormalities and longer repolarisation intervals than those with normal CMR and controls (82% vs 69% vs 42%, p < 0.001). Routinely reported ECG abnormalities had poor discriminative ability (area-under-the-receiver-operating curve: AUROC) for abnormal CMR, AUROC 0.56 (95% CI 0.47-0.65), p = 0.185; worse among female than male patients. Adding JTc and QTc disp improved the AUROC to 0.64 (95% CI 0.55-0.74), p = 0.002, the sensitivity of the ECG increased from 81.6% to 98.0%, negative predictive value from 84.7% to 96.3%, negative likelihood ratio from 0.60 to 0.13, and reduced sex-dependence variabilities of ECG diagnostic parameters. CONCLUSION: Post-hospitalised COVID-19 patients have more ECG abnormalities than controls. Normal ECGs, including normal repolarisation intervals, reliably exclude CMR abnormalities in male and female patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA